1.
Curr Med Imaging ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37691206

RESUMO

OBJECTIVE: Compared thyroid volumes measured by 2-D and 3-D US with those of resected specimens and proposed new models to improve measurement accuracy. METHODS: This study included 80 patients who underwent total thyroidectomy. One 2D_model and one 3D_model were developed using piecewise linear regression analysis. The accuracy of these models was compared using an ellipsoid model (2-D_US value × 0.5), 3-D_US value, and Ying's model [1.76 + (2-D_US value × 0.38)]. RESULTS: The new 2D_model was: V=2.66 + (0.71 * X1) - (1.51 * X2). In this model, if 2-D_US value <= 228.39, X1 = 2-D_US value and X2 = 0; otherwise, X1 = 2-D_US value and X2 = 2-D_US value - 228.39. The 3D_model was: V= 2.90 + (1.08 * X1) + (2.43 * X2). In this model, if 3-D_US value <= 102.06, X1 = 3-D_US value and X2 = 0; otherwise, X1 = 3-D_US value and X2 = 3-D_US value - 102.06. The accuracy of the new models was higher than that of the 3-D_US value, the ellipsoid model, and Ying's model (P<0.05). CONCLUSION: The models established are more accurate than the traditional ones and can accurately measure thyroid volume.

2.
BMC Musculoskelet Disord ; 22(1): 112, 2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-33499842

RESUMO

BACKGROUND: Carpal tunnel syndrome (CTS) is the most common entrapment symptom in the peripheral nerves. High-frequency ultrasound (HFUS) is widely used in the diagnosis of CTS. Virtual Touch Tissue Imaging and Quantification (VTIQ), which provides more information about the hardness of organization, is used to diagnose CTS. However, the data of diagnostic value of them in various degrees of CTS are limited. Whether the combination of HFUS and VTIQ can improve the diagnostic efficiency also remains unknown. The study aimed to explore the diagnostic value of HFUS and VTIQ in various degrees of CTS and whether combination of HFUS and VTIQ could improve the diagnostic efficiency of CTS. METHODS: A collection and analysis of 133 CTS patients and 35 volunteers from January 2016 to January 2019 were performed. We compared the clinical characteristics, cross-sectional area (CSA) value and shear wave velocity SWVmean value of CTS group with volunteer group. RESULTS: The CSA value and SWVmean value of CTS cohort were significantly higher than volunteer group (10.79 ± 2.88 vs. 8.06 ± 1.39, p < 0.001, 4.36 ± 0.95 vs. 3.38 ± 1.09, p < 0.001, respectively). The area under the curve (AUC) of receiver operating characteristic (ROC) curve of CSA value and SWVmean value were 0.794 and 0.757, respectively. Hierarchical analysis of CSA value and SWVmean value showed that the AUC in the moderate and severe CTS group were higher than in mild CTS group. Furthermore, the CSA value combined with SWVmean value used to diagnose mild CTS was 0.758, which was higher than that of single CSA value or single SWVmean value. CONCLUSIONS: Both HFUS and VTIQ technology were feasible to evaluate CTS. HFUS was suitable for use in diagnosis of moderate and severe CTS. For mild CTS, combination of HFUS and VTIQ was relevant to improve the diagnostic efficiency of CTS.


Assuntos
Síndrome do Túnel Carpal , Área Sob a Curva , Síndrome do Túnel Carpal/diagnóstico por imagem , Testes Diagnósticos de Rotina , Humanos , Nervo Mediano/diagnóstico por imagem , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia
3.
Scand J Gastroenterol ; 52(4): 403-408, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28079407

RESUMO

OBJECTIVE: The objective of this study is to evaluate the gastric emptying in patients with systemic lupus erythematosus (SLE) with gastrointestinal involvement using three-dimensional (3D) ultrasonography. METHODS: The gastric emptying times at 25% (T1), 50% (T2), and 75% (T3) of SLE patients with gastrointestinal involvement (n = 40) and healthy controls (n = 80) were evaluated and compared. In addition, the correlations among the gastric wall thickness, SLE disease activity index (SLEDAI), and upper gastrointestinal symptoms were calculated. RESULTS: The gastric wall thickness was correlated with the SLEDAI (r = 0.928, p < 0.001) and the upper gastrointestinal symptom index (r = 0.848, p < 0.001). The emptying times T1, T2, and T3 of the SLE patients were 17.08 ± 2.65 min (mean ± standard deviation), 39.85 ± 6.54 min, and 83.58 ± 7.12 min, respectively. For healthy controls, they were 19.65 ± 5.39 min, 41.08 ± 7.51 min, and 70.34 ± 8.03 min. The T1 of the SLE patients was shorter (p < 0.01), while the T3 was longer (p < 0.001). Moreover, T3 in the SLE group had the best correlation with the upper gastrointestinal symptom index (r = 0.553, p < 0.001). T1 in the SLE group was anti-correlated with early satiety (r = -0.366, p < 0.05). CONCLUSIONS: Combining the emptying times T1 and T3, as well as the gastric wall thickness, the SLEDAI and the upper gastrointestinal symptoms index can provide accurate clinical diagnosis of SLE with gastric involvement.


Assuntos
Esvaziamento Gástrico , Lúpus Eritematoso Sistêmico/fisiopatologia , Estômago/diagnóstico por imagem , Estômago/patologia , Ultrassonografia , Adulto , Estudos de Casos e Controles , China , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
4.
Br J Radiol ; 89(1068): 20160366, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27759430

RESUMO

OBJECTIVE: Improvement in regional blood flow has been shown to ameliorate diabetic gastroparesis. We compared the gastric blood supply in patients with diabetes with gastroparesis with that in healthy subjects, by using contrast-enhanced ultrasound (CEUS). METHODS: 30 healthy subjects and 40 patients with diabetic gastroparesis were enrolled. The CEUS parameters of greater curvatures of the antrum (GCOA) and lesser curvatures of the antrum (LCOA), including peak intensity (PI) and the area under the curve (AUC), were compared between the two groups. RESULTS: Intraclass correlation coefficient (ICC) for PI in healthy subjects measured on CEUS were 0.831-0.857 and 0.803-0.823, respectively. Intra-ICC and inter-ICC values for AUC were 0.805-0.823 and 0.813-0.815, respectively. In both groups, no significant difference was observed in PI and AUC values of GCOA and LCOA (p > 0.05). The PI and AUC of GCOA and LCOA in the diabetes group were less than those in the normal group (p < 0.05). CONCLUSION: CEUS can assess stomach wall vascularity with a high reproducibility. Microcirculation in the antrum of patients with diabetic gastroparesis is poorer than that of normal group, which is consistent with the mechanisms of diabetic neuropathy. CEUS can be used for evaluation of microvascular perfusion in patients with stomach wall disease. Advances in knowledge: This was the first study to use CEUS for assessment of blood supply of the gastric wall and to compare microvascular perfusion between healthy individuals and patients with diabetes with gastroparesis.


Assuntos
Meios de Contraste , Complicações do Diabetes/diagnóstico por imagem , Gastroparesia/diagnóstico por imagem , Estômago/irrigação sanguínea , Estômago/diagnóstico por imagem , Ultrassonografia , Adulto , Área Sob a Curva , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
5.
Int J Clin Exp Med ; 8(11): 20056-64, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26884917

RESUMO

OBJECTIVE: To investigate diagnostic value of ultrasonography scores (US) and contrast-enhanced ultrasonography (CEUS) in evaluating rheumatoid arthritis (RA) activity. METHODS: 39 patients with RA were included and the metacarpophalangeal, proximal interphalangeal, wrist, elbow and knee joints of them were examined by high frequency ultrasound. The severe joints and the related indexes (synovial thickness, synovial blood flow, joint effusion and bone erosion) were exposed. Then scores (0~3) were obtained and the sum was calculated. For 12 patients of the 39, 2.4 ml SonoVue was intravenously injected with observation of synovial enhancing. ROIs time-intensity curve (TIC) was obtained and the parameters including area under curve (AUC), peak intensity (PI) and time to peak (TTP) were analyzed. For 39 patients, the relationships among each parameters, ultrasonography scores, DAS28 scores and biochemical examinations (ESR, CRP, RF, anti-CCP) were analyzed. RESULTS: The US were significantly correlated with DAS28 Scores (r=0.823, P<0.01=. The correlation between US and CRP was better than that between DAS28 scores and CRP (rUS =0.692, rDAS28=0.526, P<0.01). The synovial thickness in US were correlated with DAS28 Scores and biochemical examinations (ESR, CRP) (rDAS28=0.852, rESR=0.779, rCRP=0.587, P<0.01. The AUC and PI in CEUS were significantly correlated with US (rAUC=0.832, rPI=0.809, P<0.01=. The correlations among AUC, PI and ESR were better than that between US and ESR (rAUC=0.907, rPI=0.851, rUS=0.836, P<0.01=. The correlations among AUC, PI and CRP were better than that between US and CRP (rAUC=0.855, rPI=0.854, rUS=0.692, P<0.01. CONCLUSIONS: US was almost identical with DAS28 Scores and biochemical examinations (ESR, CRP) in diagnosis of RA activity, while CEUS was almost identical with DAS28 Scores and biochemical examinations (ESR, CRP). In diagnosis of RA, US may be better than DAS28 Scores, while CEUS better than US. Both of them were useful for evaluation of RA activity.

6.
Ultrasound Med Biol ; 40(9): 1998-2003, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25023116

RESUMO

In order to explore the accuracy of ultrasonic whole stomach cylinder measurement (UWSCM) in the evaluation of gastric emptying, we measured the gastric emptying times (ET) at 25% (T1), 50% (T2) and 75% (T3) of healthy subjects and patients with diabetic gastropathy by UWSCM and scintigraphy. The ET of patients were compared with their clinical symptom scores. We found that the ET measured by UWSCM showed no significant difference with scintigraphy (p > 0.05). The correlation between them was good, and the correlation coefficient of T3 reached 0.744 (p < 0.05). All emptying times in the diabetic patients were longer than those in the healthy subjects (p < 0.05). The T3 in the diabetic group measured by UWSCM had the best correlation with the symptom index (r = 0.469, p < 0.05). We conclude that ET measured by UWSCM is accurate and T3 combining the symptoms index provides an accurate clinical basis for gastropathy.


Assuntos
Diabetes Mellitus/fisiopatologia , Esvaziamento Gástrico/fisiologia , Estômago/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Reprodutibilidade dos Testes , Fatores de Tempo , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS