Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 231, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822280

RESUMO

BACKGROUND: The main purpose of this paper is to introduce a method that can accurately locate the posterior capsule of the lens to facilitate a relatively complete resection of the anterior vitreous body. METHODS: A total of 51 patients in the experimental group and control group were enrolled in this study. Phacoemulsification combined with vitrectomy was performed in all cases. After the cataract procedure was completed in the control group, the surgeon performed a conventional anterior vitrectomy with the operative eye. In the experimental group, anterior vitrectomy was performed according to the threadiness corrugation of the posterior capsule of the lens. During the operation, with the help of triamcinolone, two surgeons confirmed the resection of the anterior vitreous cortex; the best corrected visual acuity and intraocular pressure of all patients were recorded at 1 week, 1 month and 3 months after surgery. RESULTS: Fifty patients underwent phacoemulsification combined with vitrectomy, except one patient in the experimental group who was lost to follow-up. After surgery, no significant complications were observed in all patients except two patients in the control group with temporary increases in intraocular pressure. There was no significant difference in preoperative visual acuity between the two groups (t = 0.83, P = 0.25). Both groups had varying degrees of improvement in best corrected visual acuity at 1 week, 1 month and 3 months after surgery. Moreover, there was no significant difference in BCVA between the two groups at the three follow-up time points (t=-1.15, -1.65, -1.09, P = 0.53, 0.21, 0.23). After surgery, no significant complications were observed in all patients except two patients in the control group with temporary increases in intraocular pressure. Incomplete resection of the anterior vitreous cortex was observed in 2 patients in each group, but there was no significant difference (χ2 = 7.81, P > 0.05). CONCLUSION: In the process of cataract surgery combined with vitrectomy, thready corrugation appears in the posterior capsule of the lens and is an important sign of its localization. Anterior vitrectomy can be accomplished safely and effectively with the help of thread-like corrugation, and the surgical effect is almost the same as that of traditional surgery. Especially suitable for beginners in vitreous surgery.


Assuntos
Pressão Intraocular , Facoemulsificação , Acuidade Visual , Vitrectomia , Corpo Vítreo , Humanos , Vitrectomia/métodos , Facoemulsificação/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Corpo Vítreo/cirurgia , Pressão Intraocular/fisiologia , Cápsula Posterior do Cristalino/cirurgia , Idoso de 80 Anos ou mais
2.
J Obstet Gynaecol ; 42(5): 877-882, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34569426

RESUMO

The aim of our study was to compare the efficacy of two dosages of hepatitis B immunoglobulin (HBIG) combined with HBV vaccine (HBVac) to prevent mother-to-child transmission (MTCT) of hepatitis B in HBsAg- and HBeAg-positive mother. We enrolled 331 mother-infant pairs with HBsAg- and HBeAg-positive maternal state from the Women's Hospital School of Medicine of Zhejiang University. Newborns were randomly distributed into two groups according to the dosages of HBIG injection: 100 IU and 200 IU. Newborns from both groups were injected with HBVac in the same doses. We compared the immune outcomes between the two groups and explore the influencing factors of immune outcomes through regression analysis. There was no statistically significant relationship between HBsAg serological transmission of newborns and dosages of HBIG in HBsAg- and HBeAg-positive mother (p > .05). The Logistic regression showed that high DNA load is a risk factor for passive-active immunoprophylaxis failure for both 100 IU and 200 IU group, but higher-dosage HBIG is not necessary for higher-viral-load pregnant women with HBsAg- and HBeAg-positive. In conclusion, combined application of HBVac and a single dose of 100 IU HBIG can achieve the ideal MTCT interruption results for HBsAg- and HBeAg-positive pregnant women.IMPACT STATEMENTWhat is already known on this subject? Passive-active immunoprophylaxis is proved to be effective in preventing mother-to-child transmission of hepatitis B. Hepatitis B vaccine combined with 100 IU or 200 IU immunoglobulin is mostly recommended in China.What do the results of this study add? At present, there is still a lack scientific basis for improving existing strategies and measures to prevent mother-to-child transmission of hepatitis B in China.What are the implications of these findings for clinical practice and/or further research? 100 IU and 200 IU immunoglobulin show equivalent blocking effect, and combined use of hepatitis B vaccine and 100 IU immunoglobulin is more cost-effective.


Assuntos
Hepatite B Crônica , Hepatite B , Complicações Infecciosas na Gravidez , Feminino , Hepatite B/prevenção & controle , Antígenos de Superfície da Hepatite B/uso terapêutico , Vacinas contra Hepatite B/uso terapêutico , Antígenos E da Hepatite B/uso terapêutico , Vírus da Hepatite B/genética , Hepatite B Crônica/tratamento farmacológico , Hepatite B Crônica/prevenção & controle , Humanos , Imunoglobulinas/uso terapêutico , Lactente , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Mães , Gravidez , Complicações Infecciosas na Gravidez/tratamento farmacológico , Complicações Infecciosas na Gravidez/prevenção & controle
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(12): 3177-80, 2009 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-20210126

RESUMO

The flame temperature was measured by the double line of atomic emission spectroscopy according to the spectra of K (766.5 and 769.9 nm) whose relative intensity was obtained by fiber spectrometer. The principles, methods and experiment system were described. The temperature measured by the double line of atomic emission spectroscopy was compared to the results measured by thermal couple under the condition of thermal equilibrium of blackbody furnace. The comparison indicated a good coherence between these two measurement methods. The method was demonstrated on coal powder and timber, and the temperature measured corresponded to reality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...