Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plants (Basel) ; 12(9)2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37176946

RESUMO

The rhizosphere microbiota plays a critical and crucial role in plant health and growth, assisting plants in resisting adverse stresses, including soil salinity. Plastic film mulching is an important method to adjust soil properties and improve crop yield, especially in saline-alkali soil. However, it remains unclear whether and to what extent the association between these improvements and rhizosphere microbiota exists. Here, from a field survey and a greenhouse mesocosm experiment, we found that mulching plastic films on saline-alkali soil can promote the growth of soybeans in the field. Results of the greenhouse experiment showed that soybeans grew better in unsterilized saline-alkali soil than in sterilized saline-alkali soil under plastic film mulching. By detecting the variations in soil properties and analyzing the high-throughput sequencing data, we found that with the effect of film mulching, soil moisture content was effectively maintained, soil salinity was obviously reduced, and rhizosphere bacterial and fungal communities were significantly changed. Ulteriorly, correlation analysis methods were applied. The optimization of soil properties ameliorated the survival conditions of soil microbes and promoted the increase in relative abundance of potential beneficial microorganisms, contributing to the growth of soybeans. Furthermore, the classification of potential key rhizosphere microbial OTUs were identified. In summary, our study suggests the important influence of soil properties as drivers on the alteration of rhizosphere microbial communities and indicates the important role of rhizosphere microbiota in promoting plant performance in saline-alkali soil under plastic film mulching.

2.
Acta Biomater ; 142: 402-412, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35085798

RESUMO

The existing biodegradable magnesium alloy stent (BMgS) structure is prone to problems, such as insufficient support capacity and early fracture at areas of concentrated stress. Herein, a stent structural design, which reduced the cross section of the traditional sin-wave stent by nearly 30% and introduces a regular arc structure in the middle of the support ring. The influence of the dual-parameter design of bending radius (r) and ring length (L) on plastic deformation, expansion and compression resistance performances are discussed. The non-dominated sorting genetic algorithm II (NSGA-II) was used to search for the optimal solution. It was found that the introduction of parameter r effectively improved the plastic deformation and expansion performance, and the reduction of L improved stent compression resistance. Finally, an optimized stent configuration was obtained. In vitro mechanical tests, including balloon inflation, radial strength and flexibility, verified the simulation results. The radial strength for the optimised stent increases by approximately 40% compared with that for the sinusoidal stent. Microarea X-ray diffraction result shows that the circumferential residual stress for the optimised stent decreases by half compared with that for the sinusoidal stent, thus effectively reducing the stress concentration phenomenon. STATEMENT OF SIGNIFICANCE: Despite current progress in BMgS research, the optimal design of the structure is limited. We present a new type of structurally designed stent. The performance of this stent was analysed by a finite element method and experimentally verified. The structural design positively influenced stent performance.


Assuntos
Ligas , Magnésio , Ligas/química , Ligas/farmacologia , Análise de Elementos Finitos , Magnésio/química , Magnésio/farmacologia , Plásticos , Desenho de Prótese , Stents , Estresse Mecânico
3.
Acta Biomater ; 121: 713-723, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33321221

RESUMO

Zn-0.8 wt.% Li-0.1 wt.% Mn wire with the diameter of 0.3 mm was fabricated and further processed into gastrointestinal staple, and its in vitro and in vivo biodegradation behavior and biocompatibility were studied systematically. The experimental Zn-Li-Mn alloy staple could deform from the original U-shape to B-shape without fracture, indicating its good mechanical property. Due to the residual stress concentration caused by anastomosis deformation, the feet and leg arc part of the staple were more prone to degradation. The Zn-Li-Mn alloy staple sustained integrity after immersion in Hanks' solution and simulated gastric fluid (SGF) for 28 days, and the degradation rate in SGF was about 4 times of that in Hanks' solution. Furthermore, Zn-Li-Mn alloy staples were utilized for gastrointestinal anastomosis in pig models, with clinically-used titanium alloy staples as a comparison. No anastomotic leakage and severe inflammation were observed after operation. The Zn-Li-Mn alloy staple maintained mechanical integrity within 8 weeks' implantation. The gastrointestinal tissue healed after 12 weeks, and no obvious side effects were detected during the whole implantation period, demonstrating the good biocompatibility of Zn-Li-Mn alloy staple. Thus, Zn-Li-Mn alloy staple fabricated in this work displayed the promising potential in the gastrointestinal anastomosis.


Assuntos
Ligas , Magnésio , Implantes Absorvíveis , Anastomose Cirúrgica , Animais , Teste de Materiais , Suínos , Zinco
4.
Acta Biomater ; 97: 671-680, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31394294

RESUMO

Biodegradable magnesium alloys have attracted research interest as matrix materials for next-generation absorbable metallic coronary stents. Subject to cyclic stresses, magnesium alloy stents (MAS) are prone to premature failures caused by corrosion fatigue damage. This work aimed to develop a numerical continuum damage mechanics model, implemented with the finite element method, which can account for the corrosion fatigue of Mg alloys and the applications in coronary stents. The parameters in the resulting phenomenological model were calibrated using our previous experimental data of HP-Mg and WE43 alloy and then applied in assessing the performance of the MAS. The results indicated that it was valid to predict the degradation rate, the damage-induced reduction of the radial stiffness, and the critical location of the MAS. Furthermore, this model and the numerical procedure can be easily adapted for other biodegradable alloy systems, for instance, Fe and Zn, and used to achieve the optimal degradation rate while improving fatigue endurance. STATEMENT OF SIGNIFICANCE: Subject to cyclic stresses, magnesium alloy stents are prone to premature failures caused by corrosion fatigue damage. This work aimed to develop a numerical continuum damage mechanics model, implemented with the finite element method, which can account for the corrosion fatigue of Mg alloys and the applications in coronary stents. The results indicated that it was valid to predict the degradation rate, damage-induced reduction of the radial stiffness, and the critical location of the Mg alloy stent; therefore, these stents can be easily adapted to other biodegradable alloy systems such as Fe and Zn.


Assuntos
Implantes Absorvíveis , Ligas , Modelos Cardiovasculares , Stents , Estresse Mecânico , Animais , Análise de Elementos Finitos , Humanos
5.
Acta Biomater ; 98: 50-66, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-30853611

RESUMO

Proper alloying magnesium with element scandium (Sc) could transform its microstructure from α phase with hexagonal closed-packed (hcp) structure into ß phase with body-cubic centered (bcc) structure. In the present work, the Mg-30 wt% Sc alloy with single α phase, dual phases (α + ß) or ß phase microstructure were developed by altering the heat-treatment routines and their suitability for usage within bone was comprehensively investigated. The ß phased Mg-30 wt% Sc alloy showed the best mechanical performance with ultimate compressive strength of 603 ±â€¯39 MPa and compressive strain of 31 ±â€¯3%. In vitro degradation test showed that element scandium could effectively incorporate into the surface corrosion product layer, form a double-layered structure, and further protect the alloy matrix. No cytotoxic effect was observed for both single α phased and ß phased Mg-30 wt% Sc alloys on MC3T3 cell line. Moreover, the ß phased Mg-30 wt%Sc alloy displayed acceptable corrosion resistance in vivo (0.06 mm y-1) and maintained mechanical integrity up to 24 weeks. The degradation process did not significantly influence the hematology indexes of inflammation, hepatic or renal functions. The bone-implant contact ratio of 75 ±â€¯10% after 24 weeks implied satisfactory integration between ß phased Mg-30 wt%Sc alloy and the surrounding bone. These findings indicate a potential usage of the bcc-structured Mg-Sc alloy within bone and might provide a new strategy for future biomedical magnesium alloy design. STATEMENT OF SIGNIFICANCE: Scandium is the only rare earth element that can transform the matrix of magnesium alloy into bcc structure, and Mg-30 wt%Sc alloy had been recently reported to exhibit shape memory effect. The aim of the present work is to study the feasibility of Mg-30 wt%Sc alloy with different constitutional phases (single α phase, single ß phase or dual phases (α + ß)) as biodegradable orthopedic implant by in vitro and in vivo testings. Our findings showed that ß phased Mg-30 wt%Sc alloy which is of bcc structure exhibited improved strength and superior in vivo degradation performance (0.06 mm y-1). No cytotoxicity and systematic toxicity were shown for ß phased Mg-30 wt%Sc alloy on MC3T3 cell model and rat organisms. Moreover, good osseointegration, limited hydrogen gas release and maintained mechanical integrity were observed after 24 weeks' implantation into the rat femur bone.


Assuntos
Ligas/química , Osso e Ossos/fisiologia , Magnésio/química , Escândio/química , Implantes Absorvíveis , Animais , Densidade Óssea , Varredura Diferencial de Calorimetria , Morte Celular , Corrosão , Eletroquímica , Hemólise , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Hidrogênio/análise , Concentração de Íons de Hidrogênio , Magnésio/sangue , Fenômenos Mecânicos , Camundongos , Adesividade Plaquetária , Ratos Sprague-Dawley , Propriedades de Superfície , Termogravimetria , Distribuição Tecidual , Difração de Raios X , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...