J Appl Clin Med Phys ; 22(3): 216-223, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33666339

RESUMO

PURPOSE: To assess the implementation, accuracy, and validity of the dosimetric leaf gap correction (DLGC) in Mobius3D VMAT plan calculations. METHODS: The optimal Mobius3D DLGC was determined for both a TrueBeam with a Millennium multi-leaf collimator and a TrueBeamSTx with a high-definition multi-leaf collimator. By analyzing a broad series of seven VMAT plans and comparing the calculated to the measured dose delivered to a cylindrical phantom, optimal DLGC values were determined by minimizing the dose difference for both the collection of all plans, as well as for each plan individually. The effects of plan removal from the optimization of the collective DLGC value, as well as plan-specific DLGC values, were explored to determine the impact of plan suite design on the final DLGC determination. RESULTS: Optimal collective DLGC values across all energies were between -0.71 and 0.89 mm for the TrueBeam, and between 0.35 and 1.85 mm for the TrueBeamSTx. The dose differences ranged between -6.1% and 2.6% across all plans when the optimal collective DLGC values were used. On a per-plan basis, the plan-specific optimal DLGC values ranged from -4.36 to 2.35 mm for the TrueBeam, and between -1.83 and 2.62 mm for the TrueBeamSTx. Comparing the plan-specific optimal DLGC to the average absolute leaf position from the central axis for each plan, a negative correlation was observed. CONCLUSIONS: The optimal DLGC determination depends on the plans investigated, making it essential for users to utilize a suite of test plans that encompasses the full range of expected clinical plans when determining the optimal DLGC value. Validation of the secondary dose calculation should always be based on measurements, and not a comparison with the primary TPS. Varying disagreement with measurements across plans for a single DLGC value indicates potential limitations in the Mobius3D MLC model.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radiometria , Dosagem Radioterapêutica , Software
2.
J Appl Clin Med Phys ; 21(12): 54-61, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33119933

RESUMO

PURPOSE: Dark current radiation produced during linac beam-hold has the potential to lead to unplanned dose delivered to the patient. With the increased usage of motion management and step-and-shoot IMRT deliveries for MR-guided systems leading to increased beam-hold time, it is necessary to consider the impact of dark current radiation on patient treatments. METHODS: The relative dose rate due to dark current for the ViewRay MRIdian linac was measured longitudinally over 15 months (June 2018-August 2019). Ion chamber measurements were acquired with the linac in the beam-hold state and the beam-on state, with the ratio representing the relative dark current dose rate. The potential contribution of the dark current dose to the overall prescription was retrospectively analyzed for 972 fractions from 83 patients over the same time period. The amount of time spent in the beam-hold state was combined with the monthly measured relative dark current dose rate to estimate the dark current dose contribution. RESULTS: The relative dark current dose rate compared to the beam-on dose rate was 0.12% ± 0.027%. In a near worst-case estimation, the dark current dose contribution accounted for 0.90% ± 0.67% of the prescription dose across all fractions (3.61% maximum). Gantry and MLC motion between segments accounted for 87% of the dark current contribution, with the remaining 13% attributable to gating during segment delivery. The largest dark current contributions were associated with plans delivering a small dose per treatment segment. CONCLUSIONS: The dark current associated with new clinical treatment units should be considered prior to treatment delivery to ensure it will not lead to dosimetric inaccuracies. For the MRIdian linac system investigated in this work, the contribution from dark current remained relatively low, though users should be cognizant of the larger potential dosimetric contribution for plans with small doses per segment.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Estudos Retrospectivos
3.
J Appl Clin Med Phys ; 21(8): 183-190, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32533758

RESUMO

Intrafraction imaging-based motion management systems for external beam radiotherapy can rely on internal surrogate structures when the target is not easily visualized. This work evaluated the validity of using liver vessels as internal surrogates for the estimation of liver tumor motion. Vessel and tumor motion were assessed using ten two-dimensional sagittal MR cine datasets collected on the ViewRay MRIdian. For each case, a liver tumor and at least one vessel were tracked for 175 s. A tracking approach utilizing block matching and multiple simultaneous templates was applied. Accuracy of the tracked motion was calculated from the error between the tracked centroid position and manually defined ground truth annotations. The patient's abdomen surface and diaphragm were manually annotated in all frames. The Pearson correlation coefficient (CC) was used to compare the motion of the features and tumor in the anterior-posterior (AP) and superior-inferior (SI) directions. The distance between the centroids of the features and the tumors was calculated to assess if feature proximity affects relative correlation, and the tumor range of motion was determined. Intra- and interfraction motion amplitude variabilities were evaluated to further assess the relationship between tumor and feature motion. The mean CC between the motion of the vessel and the tumor were 0.85 ± 0.11 (AP) and 0.92 ± 0.04 (SI), 0.83 ± 0.11 (AP) and -0.89 ± 0.06 (SI) for the surface and tumor, and 0.80 ± 0.17 (AP) and 0.94 ± 0.03 (SI) for the diaphragm and tumor. For intrafraction analysis, the average amplitude variability was 2.47 ± 0.77 mm (AP) and 3.14 ± 1.49 mm (SI) for the vessels, 2.70 ± 1.08 mm (AP) and 3.43 ± 1.73 mm (SI) for the surface, and 2.76 ± 1.41 mm (AP) and 2.91 ± 1.38 mm (SI) for the diaphragm. No relationship between distance and motion correlation was observed. The motion of liver tumors and liver vessels was well correlated, making vessels a suitable surrogate for tumor motion in the liver.


Assuntos
Neoplasias Hepáticas , Respiração , Diafragma/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Movimento (Física) , Movimento
4.
Med Phys ; 45(11): 4816-4821, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30220085

RESUMO

PURPOSE: Latencies for motion management systems have previously been presented as guidelines for system development and implementation. These guidelines consider the overall system latency, including data acquisition, algorithm processing, and linac triggering time. However, during system development, the triggering latency of the clinical linear accelerator is often considered fixed. This paper presents a method to decouple the linac-only triggering latency from the total system latency such that latency can be considered in terms of only the linac-independent aspects of the system. METHODS: The linac-only latency was investigated by considering the time at which a linac response was observed relative to the time at which a beam-on/off triggering signal was sent to the linac. The relative time between the two signals was analyzed using a multichannel oscilloscope with input signals from a custom gating box to manually trigger the beam state as well as a diode positioned at beam isocenter to monitor the linac response. The beam-on/off latency was measured at multiple energies (6/18 MV) and repetition rates (100-600 MU/min) to investigate beam setting dependencies. RESULTS: The measured latency was observed to be dependent on the accelerator settings for repetition rate and energy, with beam-on latencies decreasing with increasing repetition rate and decreasing energy. In contrast, the opposite trend was present for the observed beam-off latency. At 600 MU/min, beam-on/off latencies were observed to be 3.37/1.45 ms for a 6 MV beam and 6.02/0.73 ms for an 18 MV beam. Negative latencies were possible for beam-off measurements due to the mechanical latency being less than the pulse separation at given repetition rates. CONCLUSIONS: The linac latency associated with triggering the beam-on/off was determined to have a minor contribution to the total allowable system latency; thus, the majority of the total system latency can be attributed to linac-independent factors.


Assuntos
Movimento , Aceleradores de Partículas , Radioterapia/instrumentação
5.
Med Phys ; 44(11): 5889-5900, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28898419

RESUMO

PURPOSE: The implementation of motion management techniques in radiation therapy can aid in mitigating uncertainties and reducing margins. For motion management to be effective, it is necessary to track key structures both accurately and at a real-time speed. Therefore, the focus of this work was to develop a 2D algorithm for the real-time tracking of ultrasound features to aid in radiation therapy motion management. MATERIALS AND METHODS: The developed algorithm utilized a similarity measure-based block matching algorithm incorporating training methods and multiple simultaneous templates. The algorithm is broken down into three primary components, all of which use normalized cross-correlation (NCC) as a similarity metric. First, a global feature shift to account for gross displacements from the previous frame is determined using large block sizes which encompass the entirety of the feature. Second, the most similar reference frame is chosen from a series of training images that are accumulated during the first K frames of tracking to aid in contour consistency and provide a starting point for the localized template initialization. Finally, localized block matching is performed through the simultaneous use of both a training frame and the previous frame. The localized block matching utilizes a series of templates positioned at the boundary points of the training and previous contours. The weighted final boundary points from both the previous and the training frame are ultimately combined and used to determine an affine transformation from the previous frame to the current frame. RESULTS: A mean tracking error of 0.72 ± 1.25 mm was observed for 85 point-landmarks across 39 ultrasound sequences relative to manual ground truth annotations. The image processing speed per landmark with the GPU implementation was between 41 and 165 frames per second (fps) during the training set accumulation, and between 73 and 234 fps after training set accumulation. Relative to a comparable multithreaded CPU approach using OpenMP, the GPU implementation resulted in speedups between -30% and 355% during training set accumulation, and between -37% and 639% postaccumulation. CONCLUSIONS: Initial implementations indicated an accuracy that was comparable to or exceeding those achieved by alternative 2D tracking methods, with a computational speed that is more than sufficient for real-time applications in a radiation therapy environment. While the overall performance reached levels suitable for implementation in radiation therapy, the observed increase in failures for smaller features, as well as the algorithm's inability to be applied to nonconvex features warrants additional investigation to address the shortcomings observed.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Algoritmos , Humanos , Movimento , Radioterapia Guiada por Imagem , Fatores de Tempo , Ultrassonografia
6.
J Radiosurg SBRT ; 4(3): 225-234, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29296447

RESUMO

PURPOSE: To develop a fundamentally new stereotactic radiosurgery (SRS) collimator design which utilizes initially off-axis Compton scattered photons to increase the dose rate at isocenter for small field treatments. MATERIALS AND METHODS: The proposed design added a set of conical slits to a standard cylindrical collimator to allow for scattered photons within the collimator to still contribute to the overall target dose. The design optimization was broken down into two regions: a solid interaction plate and a Compton slit region. The interaction plate geometry was developed to facilitate Compton scattering towards the target, and the Compton slit geometry was optimized to allow for Compton scattered photons to travel unattenuated towards the target. A series of sensitivity studies were performed using Monte Carlo N-Particle (MCNP6) Transport Code to optimize the geometry of the collimator focusing on the material, thickness, cone size, number of slits and slit width. RESULTS: An optimized collimator design incorporating 6 slits for a 4 mm target allowed for an increase in the dose rate of 3.5% while limiting off axis increases between 1 and 5 cm to an average of less than 1% relative to standard collimator designs. CONCLUSION: Preliminary designs present a proof of concept and suggest the potential for increases in dose rate for linac-based SRS systems. These designs have been able to achieve increases while maintaining a relatively low dose rate outside of the target. Further exploration into non-linear optimization of the slits and interaction plate geometry may lead to further increases than presently demonstrated.This concept warrants further study with actual measurement and to be tested for its practicality in clinical use.

SELEÇÃO DE REFERÊNCIAS