Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JPEN J Parenter Enteral Nutr ; 27(6): 419-22, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14621123

RESUMO

BACKGROUND: N-acetyl-L-tyrosine (NAT) is commonly used in place of tyrosine in parenteral nutrition, but human studies carried out to date indicate considerable amounts of it are excreted unchanged in the urine. NAT retention has not been well studied in parenterally fed adults. METHODS: NAT retention was measured in 13 adults receiving continuous parenteral nutrition with Aminosyn II 15% (Abbott Laboratories, Abbott Park, IL). RESULTS: Approximately 35% of administered NAT was excreted unchanged in the urine, with no important effect of infusion rate, N balance, or level of renal function on this value. Sufficient NAT was retained that the prescription of 1 g total amino acids/kg x day(-1) using this product exceeded the combined recommended dietary allowance for aromatic amino acids CONCLUSION: As used in the clinical setting, the phenylalanine and NAT composition of Aminosyn II is sufficient to meet the combined aromatic amino acid needs of adults with normal phenylalanine hydroxylase activity.


Assuntos
Nutrição Parenteral , Tirosina/análogos & derivados , Tirosina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Biomarcadores/urina , Glicemia/metabolismo , Creatinina/urina , Feminino , Humanos , Infusões Parenterais , Rim/metabolismo , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Resultado do Tratamento , Tirosina/urina , Ureia/urina
2.
J Opt Soc Am A Opt Image Sci Vis ; 20(1): 11-7, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12542313

RESUMO

Traditionally, contour interaction has been investigated at the visual acuity limit using a Landolt C and flanking bars, performance being quantified in terms of a percent correct measure. More recently, it has been shown that the properties of the contour interaction are different when larger stimuli are used: Contour interaction is not polarity specific, and spatial frequency tuning for an unflanked C is broader. Here we quantify contour interaction for stimuli 5x larger than the resolution limit in terms of contrast thresholds. We show that polarity of bars has little effect on unfiltered stimuli but does show very different effects on the spatial-frequency-tuning curves for discrimination of the Landolt C. This explains the polarity dependence of crowding at the visual acuity limit and its independence for larger unfiltered targets. Thus the underlying filtering function is composed of more than one mechanism, affected differently depending on the relative polarity of the test and flank contours.


Assuntos
Fóvea Central/fisiologia , Modelos Biológicos , Limiar Sensorial/fisiologia , Visão Ocular/fisiologia , Sensibilidades de Contraste/fisiologia , Discriminação Psicológica/fisiologia , Humanos , Testes Visuais , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...