Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Emerg Infect Dis ; 27(10): 2662-2665, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34399086

RESUMO

We used the BinaxNOW COVID-19 Ag Card to screen 1,540 asymptomatic college students for severe acute respiratory syndrome coronavirus 2 in a low-prevalence setting. Compared with reverse transcription PCR, BinaxNOW showed 20% overall sensitivity; among participants with culturable virus, sensitivity was 60%. BinaxNOW provides point-of-care screening but misses many infections.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Estudantes
2.
Clin Infect Dis ; 73(6): e1348-e1355, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-33846714

RESUMO

BACKGROUND: Real-time reverse transcription polymerase chain reaction (rRT-PCR) and antigen tests are important diagnostics for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Sensitivity of antigen tests has been shown to be lower than that of rRT-PCR; however, data to evaluate epidemiologic characteristics that affect test performance are limited. METHODS: Paired mid-turbinate nasal swabs were collected from university students and staff and tested for SARS-CoV-2 using both Quidel Sofia SARS Antigen Fluorescent Immunoassay (FIA) and rRT-PCR assay. Specimens positive by either rRT-PCR or antigen FIA were placed in viral culture and tested for subgenomic RNA (sgRNA). Logistic regression models were used to evaluate characteristics associated with antigen results, rRT-PCR cycle threshold (Ct) values, sgRNA, and viral culture. RESULTS: Antigen FIA sensitivity was 78.9% and 43.8% among symptomatic and asymptomatic participants, respectively. Among rRT-PCR positive participants, negative antigen results were more likely among asymptomatic participants (odds ratio [OR] 4.6, 95% confidence interval [CI]: 1.3-15.4) and less likely among participants reporting nasal congestion (OR 0.1, 95% CI: .03-.8). rRT-PCR-positive specimens with higher Ct values (OR 0.5, 95% CI: .4-.8) were less likely, and specimens positive for sgRNA (OR 10.2, 95% CI: 1.6-65.0) more likely, to yield positive virus isolation. Antigen testing was >90% positive in specimens with Ct values < 29. Positive predictive value of antigen test for positive viral culture (57.7%) was similar to that of rRT-PCR (59.3%). CONCLUSIONS: SARS-CoV-2 antigen test advantages include low cost, wide availability and rapid turnaround time, making them important screening tests. The performance of antigen tests may vary with patient characteristics, so performance characteristics should be accounted for when designing testing strategies and interpreting results.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Humanos , RNA , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Reversa , Sensibilidade e Especificidade , Universidades
3.
Ann Intern Med ; 174(7): 945-951, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33900791

RESUMO

BACKGROUND: To address high COVID-19 burden in U.S. nursing homes, rapid SARS-CoV-2 antigen tests have been widely distributed in those facilities. However, performance data are lacking, especially in asymptomatic people. OBJECTIVE: To evaluate the performance of SARS-CoV-2 antigen testing when used for facility-wide testing during a nursing home outbreak. DESIGN: A prospective evaluation involving 3 facility-wide rounds of testing where paired respiratory specimens were collected to evaluate the performance of the BinaxNOW antigen test compared with virus culture and real-time reverse transcription polymerase chain reaction (RT-PCR). Early and late infection were defined using changes in RT-PCR cycle threshold values and prior test results. SETTING: A nursing home with an ongoing SARS-CoV-2 outbreak. PARTICIPANTS: 532 paired specimens collected from 234 available residents and staff. MEASUREMENTS: Percentage of positive agreement (PPA) and percentage of negative agreement (PNA) for BinaxNOW compared with RT-PCR and virus culture. RESULTS: BinaxNOW PPA with virus culture, used for detection of replication-competent virus, was 95%. However, the overall PPA of antigen testing with RT-PCR was 69%, and PNA was 98%. When only the first positive test result was analyzed for each participant, PPA of antigen testing with RT-PCR was 82% among 45 symptomatic people and 52% among 343 asymptomatic people. Compared with RT-PCR and virus culture, the BinaxNOW test performed well in early infection (86% and 95%, respectively) and poorly in late infection (51% and no recovered virus, respectively). LIMITATION: Accurate symptom ascertainment was challenging in nursing home residents; test performance may not be representative of testing done by nonlaboratory staff. CONCLUSION: Despite lower positive agreement compared with RT-PCR, antigen test positivity had higher agreement with shedding of replication-competent virus. These results suggest that antigen testing could be a useful tool to rapidly identify contagious people at risk for transmitting SARS-CoV-2 during nascent outbreaks and help reduce COVID-19 burden in nursing homes. PRIMARY FUNDING SOURCE: None.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Casas de Saúde , Pandemias , SARS-CoV-2/imunologia , COVID-19/epidemiologia , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Estados Unidos/epidemiologia
4.
MMWR Morb Mortal Wkly Rep ; 70(3): 100-105, 2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33476316

RESUMO

Rapid antigen tests, such as the Abbott BinaxNOW COVID-19 Ag Card (BinaxNOW), offer results more rapidly (approximately 15-30 minutes) and at a lower cost than do highly sensitive nucleic acid amplification tests (NAATs) (1). Rapid antigen tests have received Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for use in symptomatic persons (2), but data are lacking on test performance in asymptomatic persons to inform expanded screening testing to rapidly identify and isolate infected persons (3). To evaluate the performance of the BinaxNOW rapid antigen test, it was used along with real-time reverse transcription-polymerase chain reaction (RT-PCR) testing to analyze 3,419 paired specimens collected from persons aged ≥10 years at two community testing sites in Pima County, Arizona, during November 3-17, 2020. Viral culture was performed on 274 of 303 residual real-time RT-PCR specimens with positive results by either test (29 were not available for culture). Compared with real-time RT-PCR testing, the BinaxNOW antigen test had a sensitivity of 64.2% for specimens from symptomatic persons and 35.8% for specimens from asymptomatic persons, with near 100% specificity in specimens from both groups. Virus was cultured from 96 of 274 (35.0%) specimens, including 85 (57.8%) of 147 with concordant antigen and real-time RT-PCR positive results, 11 (8.9%) of 124 with false-negative antigen test results, and none of three with false-positive antigen test results. Among specimens positive for viral culture, sensitivity was 92.6% for symptomatic and 78.6% for asymptomatic individuals. When the pretest probability for receiving positive test results for SARS-CoV-2 is elevated (e.g., in symptomatic persons or in persons with a known COVID-19 exposure), a negative antigen test result should be confirmed by NAAT (1). Despite a lower sensitivity to detect infection, rapid antigen tests can be an important tool for screening because of their quick turnaround time, lower costs and resource needs, high specificity, and high positive predictive value (PPV) in settings of high pretest probability. The faster turnaround time of the antigen test can help limit transmission by more rapidly identifying infectious persons for isolation, particularly when used as a component of serial testing strategies.


Assuntos
Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Serviços de Saúde Comunitária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arizona/epidemiologia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
5.
Int J Syst Evol Microbiol ; 69(8): 2268-2276, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31125302

RESUMO

Two unusual catalase-negative, Gram-stain-positive, Vagococcus-like isolates that were referred to the CDC Streptococcus Laboratory for identification are described. Strain SS1994T was isolated from ground beef and strain SS1995T was isolated from a human foot wound. Comparative 16S rRNA gene sequence analysis of isolates SS1994T and SS1995T against Vagococcus type strain sequences supported their inclusion in the genus Vagococcus. Strain SS1994T showed high sequence similarity (>97.0 %) to the two most recently proposed species, Vagococcus martis (99.2 %) and Vagococcus teuberi (99.0 %) followed by Vagococcus penaei (98.8 %), strain SS1995T (98.6 %), Vagococcus carniphilus (98.0 %), Vagococcus acidifermentans (98.0 %) and Vagococcus fluvialis (97.9 %). The 16S rRNA gene sequence of strain SS1995T was most similar to V. penaei (99.1 %), followed by SS1994T (98.6 %), V. martis (98.4 %), V. teuberi (98.1 %), V. acidifermentans (97.8 %), and both V. carniphilus and V. fluvialis (97.5 %). A polyphasic taxonomic study using conventional biochemical and the rapid ID 32 STREP system, MALDI-TOF MS, cell fatty acid analysis, pairwise sequence comparisons of the 16S rRNA, rpoA, rpoB, pheS and groL genes, and comparative core and whole genome sequence analyses revealed that strains SS1994T and SS1995T were two novel Vagococcus species. The novel taxonomic status of the two isolates was confirmed with core genome phylogeny, average nucleotide identity <84 % and in silico DNA-DNA hybridization <28 % to any other Vagococcus species. The names Vagococcusbubulae SS1994T=(CCUG 70831T=LMG 30164T) and Vagococcusvulneris SS1995T=(CCUG 70832T=LMG 30165T) are proposed.


Assuntos
Enterococcaceae/classificação , Pé/microbiologia , Filogenia , Carne Vermelha/microbiologia , Ferimentos e Lesões/microbiologia , Animais , Técnicas de Tipagem Bacteriana , Composição de Bases , Bovinos , DNA Bacteriano/genética , Enterococcaceae/isolamento & purificação , Ácidos Graxos/química , Genes Bacterianos , Humanos , Masculino , Hibridização de Ácido Nucleico , RNA Ribossômico 16S/genética , Análise de Sequência de DNA
6.
Genome Announc ; 4(6)2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27979941

RESUMO

The inclusion of molecular methods in the characterization of the novel species Enterococcus horridus necessitated the sequencing and assembly of the genomes of the closely related Enterococcus rotai and Enterococcus silesiacus Sequencing using Illumina technology in combination with optical mapping led to the generation of closed genomes for both isolates.

7.
mBio ; 5(4): e01386-14, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-25053786

RESUMO

Three vancomycin-resistant streptococcal strains carrying vanG elements (two invasive Streptococcus agalactiae isolates [GBS-NY and GBS-NM, both serotype II and multilocus sequence type 22] and one Streptococcus anginosus [Sa]) were examined. The 45,585-bp elements found within Sa and GBS-NY were nearly identical (together designated vanG-1) and shared near-identity over an ~15-kb overlap with a previously described vanG element from Enterococcus faecalis. Unexpectedly, vanG-1 shared much less homology with the 49,321-bp vanG-2 element from GBS-NM, with widely different levels (50% to 99%) of sequence identity shared among 44 related open reading frames. Immediately adjacent to both vanG-1 and vanG-2 were 44,670-bp and 44,680-bp integrative conjugative element (ICE)-like sequences, designated ICE-r, that were nearly identical in the two group B streptococcal (GBS) strains. The dual vanG and ICE-r elements from both GBS strains were inserted at the same position, between bases 1328 and 1329, within the identical RNA methyltransferase (rumA) genes. A GenBank search revealed that although most GBS strains contained insertions within this specific site, only sequence type 22 (ST22) GBS strains contained highly related ICE-r derivatives. The vanG-1 element in Sa was also inserted within this position corresponding to its rumA homolog adjacent to an ICE-r derivative. vanG-1 insertions were previously reported within the same relative position in the E. faecalis rumA homolog. An ICE-r sequence perfectly conserved with respect to its counterpart in GBS-NY was apparent within the same site of the rumA homolog of a Streptococcus dysgalactiae subsp. equisimilis strain. Additionally, homologous vanG-like elements within the conserved rumA target site were evident in Roseburia intestinalis. Importance: These three streptococcal strains represent the first known vancomycin-resistant strains of their species. The collective observations made from these strains reveal a specific hot spot for insertional elements that is conserved between streptococci and different Gram-positive species. The two GBS strains potentially represent a GBS lineage that is predisposed to insertion of vanG elements.


Assuntos
Proteínas de Bactérias/metabolismo , Cromossomos Bacterianos/genética , Streptococcus agalactiae/efeitos dos fármacos , Streptococcus agalactiae/genética , Streptococcus anginosus/efeitos dos fármacos , Streptococcus anginosus/genética , Proteínas de Bactérias/genética , Dados de Sequência Molecular , Resistência a Vancomicina/genética , Resistência a Vancomicina/fisiologia
8.
J Clin Microbiol ; 50(12): 4131-3, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23052307

RESUMO

Pulsed-field gel electrophoresis (PFGE) was used to type 128 Streptococcus infantarius subsp. coli isolates from sea otters and mussels. Six SmaI PFGE groups were detected, with one predominant group representing 57% of the isolates collected over a wide geographic region. Several sea otter and mussel isolates were highly related, suggesting that an environmental infection source is possible.


Assuntos
Endocardite/veterinária , Lontras/microbiologia , Sepse/veterinária , Infecções Estreptocócicas/veterinária , Streptococcus/classificação , Streptococcus/isolamento & purificação , Animais , Bivalves/microbiologia , Análise por Conglomerados , Eletroforese em Gel de Campo Pulsado , Endocardite/microbiologia , Genótipo , Epidemiologia Molecular , Tipagem Molecular , Sepse/microbiologia , Infecções Estreptocócicas/microbiologia , Streptococcus/genética
9.
PLoS One ; 7(2): e32169, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22384169

RESUMO

We recently investigated three cases of bacterial meningitis that were reported from a midwestern radiology clinic where facemasks were not worn during spinal injection of contrast agent during myelography procedures. Using pulsed field gel electrophoresis we linked a case strain of S. salivarius to an oral specimen of a radiology physician assistant (RPA). We also used a real-time PCR assay to detect S. salivarius DNA within a culture-negative cerebrospinal fluid (CSF) specimen. Here we extend this investigation through using a nested PCR/sequencing strategy to link the culture-negative CSF specimen to the case strain. We also provide validation of the real-time PCR assay used, demonstrating that it is not solely specific for Streptococcus salivarius, but is also highly sensitive for detection of the closely related oral species Streptococcus vestibularis. Through using multilocus sequence typing and 16S rDNA sequencing we further strengthen the link between the CSF case isolate and the RPA carriage isolate. We also demonstrate that the newly characterized strains from this study are distinct from previously characterized S. salivarius strains associated with carriage and meningitis.


Assuntos
Infecção Hospitalar/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Controle de Infecções/organização & administração , Transmissão de Doença Infecciosa do Profissional para o Paciente/prevenção & controle , Meningite/microbiologia , Reação em Cadeia da Polimerase/métodos , Streptococcus/metabolismo , Alelos , Líquido Cefalorraquidiano/microbiologia , Infecção Hospitalar/prevenção & controle , DNA Bacteriano/genética , Surtos de Doenças/prevenção & controle , Genótipo , Humanos , Assistentes Médicos , Radiologia , Recursos Humanos
10.
J Am Coll Radiol ; 9(3): 185-90, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22386165

RESUMO

PURPOSE: To investigate an outbreak of bacterial meningitis at an outpatient radiology clinic (clinic A) and to determine the source and implement measures to prevent additional infections. METHODS: A case was defined as bacterial meningitis in a patient undergoing myelography at clinic A from October 11 to 25, 2010. Patients who underwent myelography and other procedures at clinic A during that period were interviewed, medical records were reviewed, and infection prevention practices were assessed. Case-patient cerebrospinal fluid (CSF) specimens, oral specimens from health care personnel (HCP), and opened iohexol vials were tested for bacteria. Bacterial isolates were compared using pulsed-field gel electrophoresis. A culture-negative CSF specimen was tested using a real-time polymerase chain reaction assay. RESULTS: Three cases were identified among 35 clinic A patients who underwent procedures from October 11 to 25, 2010. All case-patients required hospitalization, 2 in an intensive care unit. Case-patients had myelography performed by the same radiology physician assistant and technician on October 25; all patients who underwent myelography on October 25 were affected. HCP did not wear facemasks and reused single-dose iohexol vials for multiple patients. Streptococcus salivarius (a bacteria commonly found in oral flora) was detected in the CSF of 2 case-patients (1 by culture, 1 using real-time polymerase chain reaction) and in HCP oral specimens; 1 opened iohexol vial contained Staphylococcus epidermidis. Pulsed-field gel electrophoresis profiles from the case-patient S salivarius and the radiology physician assistant were indistinguishable. CONCLUSIONS: Bacterial meningitis likely occurred because HCP performing myelography did not wear facemasks; lapses in injection practices may have contributed to transmission. Targeted education regarding mask use and safe injection practices is needed among radiology HCP.


Assuntos
Infecção Hospitalar/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Controle de Infecções/organização & administração , Transmissão de Doença Infecciosa do Profissional para o Paciente/prevenção & controle , Meningites Bacterianas/epidemiologia , Mielografia/efeitos adversos , Assistência Ambulatorial/métodos , Infecção Hospitalar/prevenção & controle , Surtos de Doenças/prevenção & controle , Feminino , Seguimentos , Humanos , Incidência , Masculino , Meningites Bacterianas/etiologia , Mielografia/métodos , Estudos Retrospectivos , Medição de Risco , Estados Unidos
11.
J Clin Microbiol ; 48(7): 2589-91, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20504987

RESUMO

Two women in labor received intrapartum spinal anesthesia from the same anesthesiologist approximately 1 h apart. Within 15 h, both patients developed Streptococcus salivarius meningitis and one patient died. Blood and cerebrospinal fluid (CSF) samples from both patients and tongue swab specimens from the anesthesiologist yielded isolates of an indistinguishable S. salivarius strain.


Assuntos
Raquianestesia , Técnicas de Tipagem Bacteriana/métodos , Transmissão de Doença Infecciosa do Profissional para o Paciente , Meningites Bacterianas , Streptococcus/isolamento & purificação , Língua/microbiologia , Meios de Cultura , DNA Bacteriano/análise , Eletroforese em Gel de Campo Pulsado , Evolução Fatal , Feminino , Genes Bacterianos/genética , Humanos , Corpo Clínico Hospitalar , Meningites Bacterianas/etiologia , Meningites Bacterianas/microbiologia , Gravidez , Streptococcus/genética , Streptococcus/crescimento & desenvolvimento
12.
Transfusion ; 48(10): 2177-83, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18564393

RESUMO

BACKGROUND: An elderly man with chronic myelomonocytic leukemia developed respiratory distress and died less than 48 hours after transfusion of a pool of eight whole blood-derived platelets (PLTs). Blood cultures from the recipient and cultures of remnants from the pooled PLT bag grew group C streptococci (GCS). An investigation was conducted to identify both the infection's source and the reasons for the false-negative screening result. STUDY DESIGN AND METHODS: Red blood cell (RBC) units (cocomponent from the eight donations) were traced, quarantined, and cultured. Specimens from the implicated donor were obtained. Isolates were identified and typed by 16S rRNA and pulsed-field gel electrophoresis (PFGE). The blood center screening method was reviewed. RESULTS: beta-Hemolytic GCS, cultured from 1 of 8 RBC units, linked the fatal case to a single donor. The donor's throat swab collected 20 days after donation was positive for the presence of GCS, identified as Streptococcus dysgalactiae subsp. equisimilis. Isolates from the recipient, RBC unit, residual PLTs, and donor's throat swab were indistinguishable by PFGE. The donor denied any symptoms of infection before or after donation. PLT bacterial screening at the blood center was performed using a commercially available bacterial detection system (BacT/ALERT, bioMérieux) with a threshold of 15 colony-forming units per bag. CONCLUSION: An asymptomatic donor was implicated as the source of GCS-contaminated PLTs. Current screening methods for PLTs are not sufficient to detect all bacterial contamination. Pooled PLTs are a particular challenge because the small volume of individual units places limits on culturing strategies. Improved detection of bacterial contamination of PLTs is needed.


Assuntos
Plaquetas/microbiologia , Transfusão de Plaquetas/efeitos adversos , Infecções Estreptocócicas/transmissão , Streptococcus/isolamento & purificação , Idoso , Doadores de Sangue , Evolução Fatal , Humanos , Masculino , Técnicas Microbiológicas , Streptococcus/classificação
13.
FEMS Microbiol Lett ; 229(2): 259-64, 2003 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-14680708

RESUMO

Group C and G Streptococcus dysgalactiae subspecies equisimilis (GCSE and GGSE) cause a substantial percentage of invasive disease caused by beta-hemolytic streptococci. To determine whether Streptococcus pyogenes superantigen (SAg) genes commonly exist within these organisms, 20 recent invasive GCSE and GGSE human isolates and one group G Streptococcus canis human isolate were tested for the presence of SAg genes speH, speJ, speL, speM, ssa and smeZ by polymerase chain reaction (PCR). Prior to this work, sequence-based evidence of the speM, ssa, and smeZ genes in GCSE, GGSE, and S. canis had not been documented. Eleven of the 21 isolates were PCR-positive for the presence of one to two of the SAgs speM, ssa, or smeZ, with four of these isolates carrying ssa+speM or ssa+smeZ. No isolate was positive for speH, speJ and speL. All six ssa-positive GGSE strains harbored the ssa3 allele, previously only found among S. pyogenes strains. All three smeZ-positive GGSE isolates carried one of two smeZ alleles previously only found within S. pyogenes, however the single S. canis isolate carried a new smeZ allele. All five GCSE and GGSE speM-positive isolates harbored a newly discovered speM allele. The identification of these SAgs within S. dysgalactiae subsp. equisimilis and S. canis with identical or near-identical sequences to their counterparts in S. pyogenes suggests frequent interspecies gene exchange between the three beta-hemolytic streptococcal species.


Assuntos
Antígenos de Bactérias/genética , Toxinas Bacterianas/genética , Exotoxinas/genética , Infecções Estreptocócicas/microbiologia , Streptococcus pyogenes/genética , Superantígenos/genética , Proteínas de Bactérias/genética , Humanos , Dados de Sequência Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...