Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 89(Pt 1): 453-460, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-27151437

RESUMO

In this study, a novel sandwiched electrochemiluminescence (ECL) immunosensor for the detection of carcinoembryonic antigen (CEA) was developed. The nanocomposite of polydopamine and Ag nanoparticles (PDA-AgNPs) was prepared by the redox reaction between Ag+ and dopamine. This nanocomposite not only provided an effective matrix for the immobilization of primary antibody (Ab1) but also enhanced the conductivity of the electrode. Carbon quantum dots (CQDs) were immobilized on the poly(ethylenimine) functionalized graphene oxide (PEI-GO) through amido-bond. Then Au nanoparticles were decorated on the CQDs modified PEI-GO matrix, and the resulted complex AuNPs/CQDs-PEI-GO was introduced to link secondary antibody (Ab2). The CQDs can be connected to the electrode surface through the combination of CEA with Ab1 and Ab2, and then the amplified electrochemiluminescence signal of CQDs was obtained with the synergistic effect of AgNPs, polydopamine, AuNPs and PEI-GO. Under the optimal conditions, the ECL intensity was proportional to the logarithm value of CEA concentration in the linear range from 5pgmL-1 to 500ngmL-1 with a detection limit of 1.67pgmL-1 for CEA detection. The immunosensor was applied for the CEA detection in real samples with satisfactory results. The proposed ECL immunosensor showed good performance with high sensitivity, specificity, reproducibility, stability and will be potential in clinical detection.


Assuntos
Anticorpos Imobilizados/química , Carbono/química , Antígeno Carcinoembrionário/sangue , Técnicas Eletroquímicas/métodos , Indóis/química , Nanocompostos/química , Polímeros/química , Pontos Quânticos/química , Técnicas Biossensoriais/métodos , Ouro/química , Grafite/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Medições Luminescentes/métodos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/ultraestrutura , Polietilenoimina/química , Reprodutibilidade dos Testes , Prata/química
2.
Naunyn Schmiedebergs Arch Pharmacol ; 380(2): 143-51, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19424681

RESUMO

We studied the effects of isoquinoline alkaloid neferine (Nef) extracted from the seed embryo of Nelumbo nucifera Gaertn on Human ether-à-go-go-related gene (HERG) channels stably expressed in human embryonic kidney (HEK293) cells using whole-cell patch clamp technique, western blot analysis and immunofluorescence experiment. Nef induced a concentration-dependent decrease in current amplitude according to the voltage steps and tail currents of HERG with an IC(50) of 7.419 microM (n(H) -0.5563). Nef shifted the activation curve in a significantly negative direction and accelerated recovery from inactivation and onset of inactivation, however, slowed deactivation. In addition, it had no significant influence on steady-state inactivation curve. Western blot and immunofluorescence results suggested Nef had no significant effect on the expression of HERG protein. In summary, Nef can block HERG K(+) channels that functions by changing the channel activation and inactivation kinetics. Nef has no effect on the generation and trafficking of HERG protein. A blocked-off HERG channel was one mechanism of the anti-arrhythmic effects by Nef.


Assuntos
Benzilisoquinolinas/farmacologia , Canais de Potássio Éter-A-Go-Go/antagonistas & inibidores , Nelumbo/química , Benzilisoquinolinas/administração & dosagem , Benzilisoquinolinas/isolamento & purificação , Western Blotting , Linhagem Celular , Relação Dose-Resposta a Droga , Canal de Potássio ERG1 , Canais de Potássio Éter-A-Go-Go/metabolismo , Imunofluorescência , Humanos , Concentração Inibidora 50 , Técnicas de Patch-Clamp , Sementes , Transfecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA