Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(8): 083705, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050074

RESUMO

Photoluminescence (PL) spectra from diamond nanoparticles containing negative nitrogen vacancy centers were measured by using a single multimode fiber endoscope combined with a high-sensitivity spectroscopy system. A laser light spot was produced at the distal end of the endoscope and the PL spectra from a temperature-controlled ensemble of diamond nanoparticles were measured. After calibrating the sensitivity and wavelength of the spectroscopy system, the temperature dependence of the zero-phonon line peak wavelength similar to those previously reported was obtained.

2.
Sci Rep ; 12(1): 15567, 2022 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-36151115

RESUMO

For plasma spectroscopy, Stokes spectropolarimetry is used as a method to spatially invert the viewing-chord-integrated spectrum on the basis of the correspondence between the given magnetic field profile along the viewing chord and the Zeeman effect appearing on the spectrum. Its application to fusion-related toroidal plasmas is, however, limited owing to the low spatial resolution as a result of the difficulty in distinguishing between the Zeeman and Doppler effects. To resolve this issue, we increased the relative magnitude of the Zeeman effect by observing a near-infrared emission line on the basis of the greater wavelength dependence of the Zeeman effect than of the Doppler effect. By utilizing the increased Zeeman effect, we are able to invert the measured spectrum with a high spatial resolution by Monte Carlo particle transport simulation and by reproducing the measured spectra with the semiempirical adjustment of the recycling condition at the first walls. The inversion result revealed that when the momentum exchange collisions of atoms are negligible, the velocity distribution of core-fueling atoms is mainly determined by the initial distribution at the time of recycling. The inversion result was compared with that obtained using a two-point emission model used in previous studies. The latter approximately reflects the parameters of atoms near the emissivity peak.

3.
Rev Sci Instrum ; 87(10): 103507, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27802719

RESUMO

A system to measure linear polarization in the HeI 21P-31D emission line (667.8 nm) was developed for application to plasma polarization spectroscopy. To verify the system performance, the normalized Stokes parameters were evaluated. A measurement error of less than 1% with a time resolution of 1 ms was achieved for monochromatic light in the state of complete linear polarization.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA