RESUMO
This report describes the development of a direct and rapid detection method for the pathogenic protozoan, Cryptosporidium parvum, from environmental water samples using fluorescence in situ hybridization (FISH) on a membrane filter. The hydrophilic polytetrafluoroethylene (PTFE) membrane filter with FISH-stained oocysts yielded the highest signal to noise (S/N) ratio of the different membrane filters tested. PTFE membranes retained 98.8+/-0.4% of the concentrated oocysts after washing, simultaneous permeabilization and fixation with a hot ethanol solution, and hybridization with a fluorescently labeled oligonucleotide probe. This procedure eliminates subsequent time-consuming recovery steps that often result in a loss of the actual oocysts in a given environmental water sample. Furthermore, C. parvum was successfully distinguished from Cryptosporidium muris and other species in environmental water samples with the addition of formamide into the hybridization solution. In tap water samples, the S/N ratio was heightened by washing the membrane filter prior to FISH with a 1 M HCl solution in order to reduce the large amounts of impurities and background fluorescence from the non-specific adsorption of the fluorescently labeled oligonucleotide probe.
Assuntos
Cryptosporidium parvum/isolamento & purificação , Hibridização in Situ Fluorescente/métodos , Água/parasitologia , Animais , Carbocianinas/química , Cryptosporidium parvum/genética , Sondas de DNA/genética , Corantes Fluorescentes/química , Humanos , Membranas Artificiais , Microscopia de Fluorescência , Microscopia de Interferência , OocistosRESUMO
An on-line biosensor consisting of immobilized Thiobacillus ferrooxidans and an oxygen electrode was developed for automated monitoring of acute toxicity in water samples. T. ferrooxidans is an obligatory acidophilic, autotrophic bacterium and derives its energy by the oxidation of ferrous ion, elemental sulfur, and reduced sulfur compounds including metal sulfides. The assay is based on the monitoring of a current increase by addition of toxicoids, which is caused by the inhibition of bacterial respiration and decrease in oxygen consumption. Optimum cell number on the membrane was 5.0 x 10(8) cells. The steady-state current was obtained when concentration of FeSO4 was above 3.6 mM at pH 3. The sensor response of T. ferrooxidans immobilized membrane for 5.0 microM KCN was within an error of 10% for 30 membranes. A linear relationship was obtained at KCN concentration in the range of 0.5-3.0 microM in a flow-type monitoring system. Minimum detectable concentrations of KCN, Na2S, and NaN3 were 0.5, 1.2, and 0.07 microM, respectively. The monitoring system contained two biosensors and these sensors were cleaned with sulfuric acid (pH 1.5) twice a day. This treatment could remove fouling on microbial immobilized membrane by natural water and ferrous precipitation in the flow cell. This flow-type monitoring sensor was operated continuously for 5 months. Also, T. ferrooxidans immobilized membrane can be stored for one month at 4 degrees C when preserved with wet absorbent cotton under argon gas.