Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Facial Plast Surg Clin North Am ; 32(2): 291-302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38575287

RESUMO

Nasal reconstruction remains one of the most challenging surgeries for facial plastic and reconstructive surgeons. The addition of defects extending beyond the nose adds a layer of complexity to an already technically demanding surgery. This article will focus on the management of composite defects extending beyond the boundaries of the nose. Surgeons need to have a variety of techniques at their disposal. These complex defects often require multiple local flaps, multiple stages, and, in select cases, free tissue transfer.


Assuntos
Neoplasias Nasais , Procedimentos de Cirurgia Plástica , Rinoplastia , Humanos , Nariz/cirurgia , Retalhos Cirúrgicos , Face/cirurgia , Neoplasias Nasais/cirurgia , Rinoplastia/métodos , Testa/cirurgia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38597716

RESUMO

Background: The buccal fat pad (BFP) has previously been utilized for repair of various defects of the head and neck. Objectives: We explore the utility of a pedicled buccal fat advancement-transposition (BFAT) flap in various forms of midface reconstruction through a variety of surgical approaches and characterize its volume and axial reach in human anatomic specimens. Methods: Ten adult full-head human anatomic specimens were dissected, and a single surgical case demonstrating the use of a BFAT flap is described. Results: Nasolabial, subciliary, and deep plane facelift incisions all provided access to the BFP for use as a BFAT flap. The mean volume of mobilizable fat contained within a BFAT flap accessible through external incision was 7.1 cm3. Once fully mobilized, the externalized BFAT flap had a mean axial reach of 6.9 cm without tension. We also present a case illustrating the successful use of a BFAT flap for volumization of a large midface defect secondary to Mohs micrographic surgical resection of a cutaneous malignancy. Discussion: The BFAT flap, which exhibited substantial volume and reach in this study, can be harvested through multiple dissection windows or pre-existing defects and be used to reconstruct a variety of midface defects.

3.
Am J Otolaryngol ; 45(1): 104089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37944347

RESUMO

PURPOSE: Lower eyelid malposition can be a complication following orbital floor fracture surgeries. We present our incidence of lower eyelid malposition from a large case series of orbital floor fracture repairs using the 'swinging eyelid' approach and 'hang back' technique. METHODS: A retrospective review of all orbital fracture surgeries at our institution from November 2011 to March 2021 was performed. Primary outcomes included the incidence of lower eyelid malposition by category, the average time to presentation after primary surgery, and reoperation rates among cases with lower eyelid complications. RESULTS: A total of 438 cases that involved repair of the fractured orbital floor were identified. Six patients (1.37 %) developed lower eyelid malposition following primary orbital floor repair. Two patients (0.46 %) developed reverse ptosis of the lower eyelid. Two patients (0.46 %) returned with lower lid cicatricial ectropion. One patient (0.23 %) had postoperative lower eyelid retraction. One patient (0.23 %) had postoperative lower eyelid cicatricial entropion. No cases of lower lid flattening, lower eyelid fat flattening, or eyelid notch was noted. All patients with lower eyelid malposition underwent additional surgeries except one patient with reverse ptosis (83.3 %). The average time to the presentation of postoperative complications from the surgery date was 292.8 days (range = 49 days to 3.5 years). CONCLUSION: Lower eyelid malposition after orbital floor repair is a known complication that can be decreased by employing the 'swinging eyelid' with a preseptal approach and closure by the 'hang back' technique.


Assuntos
Ectrópio , Entrópio , Fraturas Orbitárias , Humanos , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Pálpebras/cirurgia , Ectrópio/etiologia , Ectrópio/cirurgia , Entrópio/complicações , Entrópio/cirurgia , Órbita/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/cirurgia
5.
Facial Plast Surg Aesthet Med ; 25(4): 332-337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36413026

RESUMO

Background: Injuries are common in mixed martial arts (MMA) competitions. However, the risk factors for facial injury have not been delineated. Objective: Identify the facial injuries and associated risk factors of professional MMA fights. Methods: The Nevada State Athletic Commission medical injury reports from all professional Ultimate Fighting Championship bouts from 2010 to 2020 was reviewed. Fighter characteristics, details of the competition, and injuries sustained were collected. Binary logistic regressions determined significant predictors of facial injury. Results: A total of 1462 fighters were included. Most participants were male (91.0%) with mean age of 29.5 ± 4.1 years. Most fights took place between 135 and 185 lbs., lasted ≥3 rounds (59.4%), and resulted in judges' decision (50.5%) or knockout (31.2%). The facial injury rate was 15.8%, which were predominantly lacerations (12.0%) and fractures (3.6%). Multivariate regression revealed being male (p = 0.026), heavier weight (p = 0.028), more rounds fought (p = 0.019), losing (p < 0.001), and nonsubmission outcome (p = 0.017) predicted facial injury. Conclusion: Facial injuries are common in MMA fighting. The risks should be iterated to participants in this sport.


Assuntos
Traumatismos em Atletas , Traumatismos Craniocerebrais , Traumatismos Faciais , Artes Marciais , Humanos , Masculino , Adulto , Feminino , Traumatismos Faciais/epidemiologia , Traumatismos Faciais/etiologia , Traumatismos em Atletas/epidemiologia , Traumatismos em Atletas/complicações , Artes Marciais/lesões , Fatores de Risco
6.
Am J Otolaryngol ; 43(1): 103229, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34537506

RESUMO

PURPOSE: There are a variety of implant materials available for orbital floor fracture repair. Implant selection is guided by surgeon experience, availability, and patient specific needs. The purpose of this study is to describe a "wraparound" technique for nylon foil implant placement for large, isolated floor fractures that provides excellent results with low incidence of enophthalmos or other complications. MATERIALS AND METHODS: A retrospective chart review from 2012 to 2020 was conducted in patients who underwent isolated orbital floor fracture repair with the use of the "wraparound" nylon foil implant. The surgical technique is described. Preoperative CT scans were assessed, and the patients were divided into groups based on the size of the floor fracture. Postoperative data was collected including Hertel measurements and complications related to the implant. RESULTS: There were eighty patients who underwent orbital floor fracture repair with the described technique and had adequate follow-up. There were 18 (22.5%) small-sized fractures, 32 (40%) medium-sized fractures, and 30 (37.5%) large-sized fractures in the study group. One patient (3.33%) in the large fracture group had clinically significant enophthalmos of 2 mm postoperatively. There were no other patients with clinically significant enophthalmos. There were no instances of any complications related to the implant, and no patients required implant removal. CONCLUSIONS: The "wraparound" technique for a nylon foil implant provides excellent results for isolated orbital floor fractures. It provides more support and stability than traditional nylon implants for larger fractures and has minimal complication rates.


Assuntos
Órbita/lesões , Fraturas Orbitárias/cirurgia , Implantes Orbitários , Procedimentos de Cirurgia Plástica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Enoftalmia/epidemiologia , Enoftalmia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nylons , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Procedimentos de Cirurgia Plástica/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
7.
Artigo em Inglês | MEDLINE | ID: mdl-34964656

RESUMO

Introduction: The coronavirus disease 2019 pandemic has led to concerns over transmission risk from head and neck operations including facial cosmetic surgeries. Objectives: To quantify droplet and aerosol generation from rhinoplasty techniques in a human anatomic specimen model using fluorescein staining and an optical particle sizer. Methods: Noses of human anatomic specimens were infiltrated using 0.1% fluorescein. Droplets and aerosols were measured during rhinoplasty techniques including opening the skin-soft tissue envelope, monopolar electrocautery, endonasal rasping, endonasal osteotomy, and percutaneous osteotomy. Results: No visible droplet contamination was observed for any rhinoplasty techniques investigated. Compared with the negative control of anterior rhinoscopy, total 0.300-10.000 µm aerosols were increased after monopolar electrocautery (p < 0.001) and endonasal rasp (p = 0.003). Opening the skin-soft tissue envelope, endonasal osteotomies, and percutaneous osteotomies did not generate a detectable increase in aerosols (p > 0.15). Discussion and Conclusions: In this investigation, droplets were not observed under ultraviolet light, and aerosol generation was noted only with cautery and endonasal rasping.

8.
Facial Plast Surg Clin North Am ; 29(3): 447-451, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34217448

RESUMO

Eyelid coupling using the modified tarsoconjunctival flap is an effective treatment for paralytic ectropion. Eyelid position and quality of life can be improved in patients with flaccid facial paralysis using these eyelid coupling procedures. The modified tarsoconjunctival flap can obscure the lateral visual field by coupling the eyelids, but without distortion of the canthal angle and eyelid margin. The procedure is often coupled with a lateral canthoplasty or canthopexy to address horizontal laxity of the lower eyelid. Collecting standardized outcome measures will help establish the ideal treatment paradigm of paralytic eyelid malposition.


Assuntos
Ectrópio , Paralisia Facial , Ectrópio/cirurgia , Pálpebras/cirurgia , Paralisia Facial/cirurgia , Humanos , Qualidade de Vida , Retalhos Cirúrgicos
9.
Am J Otolaryngol ; 42(4): 102970, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33667797

RESUMO

INTRODUCTION: The highly contagious COVID-19 has resulted in millions of deaths worldwide. Physicians performing orbital procedures may be at increased risk of occupational exposure to the virus due to exposure to secretions. The goal of this study is to measure the droplet and aerosol production during repair of the inferior orbital rim and trial a smoke-evacuating electrocautery handpiece as a mitigation device. MATERIAL AND METHODS: The inferior rim of 6 cadaveric orbits was approached transconjunctivally using either standard or smoke-evacuator electrocautery and plated using a high-speed drill. Following fluorescein inoculation, droplet generation was measured by counting under ultraviolet-A (UV-A) light against a blue background. Aerosol generation from 0.300-10.000 µm was measured using an optical particle sizer. Droplet and aerosol generation was compared against retraction of the orbital soft tissue as a negative control. RESULTS: No droplets were observed following the orbital approach using electrocautery. Visible droplets were observed after plating with a high-speed drill for 3 of 6 orbits. Total aerosol generation was significantly higher than negative control following the use of standard electrocautery. Use of smoke-evacuator electrocautery was associated with significantly lower aerosol generation in 2 of 3 size groups and in total. There was no significant increase in total aerosols associated with high-speed drilling. DISCUSSION AND CONCLUSIONS: Droplet generation for orbital repair was present only following plating with high-speed drill. Aerosol generation during standard electrocautery was significantly reduced using a smoke-evacuating electrocautery handpiece. Aerosols were not significantly increased by high-speed drilling.


Assuntos
COVID-19/transmissão , Eletrocoagulação/efeitos adversos , Transmissão de Doença Infecciosa do Paciente para o Profissional , Exposição Ocupacional/efeitos adversos , Órbita/cirurgia , SARS-CoV-2/patogenicidade , Aerossóis , COVID-19/prevenção & controle , Cadáver , Humanos , Medição de Risco
10.
Laryngoscope Investig Otolaryngol ; 6(1): 49-57, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33614929

RESUMO

OBJECTIVE: Cadaveric simulations have shown endonasal drilling and cautery generate aerosols, which is a significant concern for otolaryngologists during the COVID-19 era. This study quantifies aerosol generation during routine rhinologic surgeries and in-office procedures in live patients. METHODS: Aerosols ranging from 0.30 to 10.0 µm were measured in real-time using an optical particle sizer during surgeries and in-office procedures. Various mask conditions were tested during rigid nasal endoscopy (RNE) and postoperative debridement (POD). RESULTS: Higher aerosol concentrations (AC) ranging from 2.69 to 10.0 µm were measured during RNE (n = 9) with no mask vs two mask conditions (P = .002 and P = .017). Mean AC (0.30-10.0 µm) were significantly higher during POD (n = 9) for no mask vs a mask covering the patient's mouth condition (mean difference = 0.16 ± 0.03 particles/cm3, 95% CI 0.10-0.22, P < .001). There were no discernible spikes in aerosol levels during endoscopic septoplasty (n = 3). Aerosol spikes were measured in two of three functional endoscopic sinus surgeries (FESS) with microdebrider. Using suction mitigation, there were no discernible spikes during powered drilling in two anterior skull base surgeries (ASBS). CONCLUSION: Use of a surgical mask over the patient's mouth during in-office procedures or a mask with a slit for an endoscope during RNE significantly diminished aerosol generation. However, whether this reduction in aerosol generation is sufficient to prevent transmission of communicable diseases via aerosols was beyond the scope of this study. There were several spikes in aerosols during FESS and ASBS, though none were associated with endonasal drilling with the use of suction mitigation. LEVEL OF EVIDENCE: 4.

11.
Am J Otolaryngol ; 42(2): 102879, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33429179

RESUMO

PURPOSE: Diplopia and ocular motility restriction following orbital fracture repair are common complications. The reported rates in the literature differ greatly, in part due to varying definitions of diplopia and methods of measurement. The purpose of this study is to describe a practical and efficient in-office method for examining ocular motility and diplopia in orbital trauma patients and to report the outcomes in a series of patients who underwent orbital floor fracture repair. MATERIALS AND METHODS: A retrospective chart review from 2012 to 2019 was conducted in patients who underwent isolated orbital floor fracture repair within 3 weeks of trauma. All patients had examinations to assess extraocular motility and subjective diplopia using the described techniques. RESULTS: Ninety-three patients underwent orbital floor fracture repair and had adequate follow-up. Preoperatively, 71 (76%) patients had some restriction in motility and 59 (63%) patients complained of diplopia. Postoperatively, only 1 patient (1.09%) had clinically significant diplopia. Five (5.4%) additional patients demonstrated mild restriction in supraduction upon detailed ophthalmic examination that was not discovered upon subjective history. No patients had worsening of diplopia or motility after surgery. CONCLUSIONS: Diplopia and motility restriction following orbital fracture repair can be a persistent problem for some patients. It is important to perform a careful ophthalmic examination to detect motility deficits and diplopia that can be significant to the patient. The true rate of restriction and diplopia may be higher using detailed ophthalmic diagnostic techniques compared to subjective patient history.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Diplopia/diagnóstico , Diplopia/etiologia , Transtornos da Motilidade Ocular/diagnóstico , Transtornos da Motilidade Ocular/etiologia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Fraturas Orbitárias/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
12.
Otolaryngol Head Neck Surg ; 164(2): 433-442, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32779974

RESUMO

OBJECTIVE: After significant restrictions initially due to the COVID-19 pandemic, otolaryngologists have begun resuming normal clinical practice. However, the risk of SARS-CoV-2 transmission to health care workers through aerosolization and airborne transmission during rhinologic surgery remains incompletely characterized. The objective of this study was to quantify the number concentrations of aerosols generated during rhinologic surgery with and without interventions involving 3 passive suction devices. STUDY DESIGN: Cadaver simulation. SETTING: Dedicated surgical laboratory. SUBJECTS AND METHODS: In a simulation of rhinologic procedures with and without different passive suction interventions, the concentrations of generated aerosols in the particle size range of 0.30 to 10.0 µm were quantified with an optical particle sizer. RESULTS: Functional endoscopic sinus surgery with and without microdebrider, high-speed powered drilling, use of an ultrasonic aspirator, and electrocautery all produced statistically significant increases in concentrations of aerosols of various sizes (P < .05). Powered drilling, ultrasonic aspirator, and electrocautery generated the highest concentration of aerosols, predominantly submicroparticles <1 µm. All interventions with a suction device were effective in reducing aerosols, though the surgical smoke evacuation system was the most effective passive suction method in 2 of the 5 surgical conditions with statistical significance (P < .05). CONCLUSION: Significant aerosol concentrations were produced in the range of 0.30 to 10.0 µm during all rhinologic procedures in this cadaver simulation. Rhinologic surgery with a passive suction device results in significant mitigation of generated aerosols.


Assuntos
Aerossóis , COVID-19/transmissão , Procedimentos Cirúrgicos Nasais/efeitos adversos , COVID-19/prevenção & controle , Cadáver , Humanos , Modelos Biológicos
13.
Am J Otolaryngol ; 42(1): 102829, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33186853

RESUMO

PURPOSE: The COVID-19 pandemic has led to concerns over transmission risk from healthcare procedures, especially when operating in the head and neck such as during surgical repair of facial fractures. This study aims to quantify aerosol and droplet generation from mandibular and midface open fixation and measure mitigation of airborne particles by a smoke evacuating electrocautery hand piece. MATERIALS AND METHODS: The soft tissue of the bilateral mandible and midface of two fresh frozen cadaveric specimens was infiltrated using a 0.1% fluorescein solution. Surgical fixation via oral vestibular approach was performed on each of these sites. Droplet splatter on the surgeon's chest, facemask, and up to 198.12 cm (6.5 ft) away from each surgical site was measured against a blue background under ultraviolet-A (UV-A) light. Aerosol generation was measured using an optical particle sizer. RESULTS: No visible droplet contamination was observed for any trials of mandible or midface fixation. Total aerosolized particle counts from 0.300-10.000 µm were increased compared to baseline following each use of standard electrocautery (n = 4, p < 0.001) but not with use of a suction evacuating electrocautery hand piece (n = 4, p = 0.103). Total particle counts were also increased during use of the powered drill (n = 8, p < 0.001). CONCLUSIONS: Risk from visible droplets during mandible and midface fixation is low. However, significant increases in aerosolized particles were measured after electrocautery use and during powered drilling. Aerosol dispersion is significantly decreased with the use of a smoke evacuating electrocautery hand piece.


Assuntos
Aerossóis/efeitos adversos , COVID-19/transmissão , Transmissão de Doença Infecciosa/estatística & dados numéricos , Período Intraoperatório , Pandemias , SARS-CoV-2 , COVID-19/epidemiologia , Humanos , Mandíbula , Estados Unidos/epidemiologia
14.
Laryngoscope Investig Otolaryngol ; 5(5): 846-852, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33134531

RESUMO

OBJECTIVE: To evaluate the association of weather, seasons, months and holidays on the frequency and pattern of pediatric facial fractures. METHODS: Retrospective review of pediatric patients treated for facial fractures at two Level I trauma centers in a midsize Midwestern US city over a 5-year period. Patients were included only if presentation was within 3 hours of inciting trauma, transfers from other facilities were excluded. Demographic characteristics, fracture patterns, operative interventions, weather data, and local public school schedules were acquired and associations were analyzed with unpaired t tests, χ2, multivariate and binomial regression model analyses. RESULTS: Two hundred and sixty patients were included. The average age (SD) was 11.8 (5.0) years, with 173 males and 87 females. The highest distribution of presentations occurred in the summer season (35.0%), on weekends and holidays (58.1%), and when the weather was described as clear (48.5%). The most common mechanisms of injury were motor vehicle collisions (25.8%), followed by sports-(21.5%) and assault-(16.5%) related injuries. Mechanisms were significantly associated with certain fracture patterns. Older age was associated with fewer orbital fractures (P < .01). Seventy-five patients (28.8%) required operative intervention. Age was found to impact the likelihood of operative intervention (Exp(ß) = 1.081, P = .03) while weather, temperature, and mechanism did not. CONCLUSION: Pediatric facial fractures are linked to warmer weather with clear skies and warmer season. Age predicts some fracture patterns and need for operative intervention. These results can be used to inform public health interventions, policymaking, and trauma staffing.Level of Evidence: Level 2b (retrospective cohort).

15.
Otolaryngol Head Neck Surg ; 163(6): 1137-1139, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32600099

RESUMO

As the coronavirus disease 2019 (COVID-19) pandemic continues to evolve through the United States and other countries, differing rates of progression and decline are occurring based on varied population densities. While some health systems are reaching a steady state of new patient cases, others are seeing a leveling off or decline, allowing for restoration of normal practices. This "reverse-surge" planning and implementation process is a colossal undertaking for health systems trying to reacquire patient access and financial stability while preserving necessary resources and maintaining precautions for another potential surge. For the otolaryngologist, reverse-surge planning involves additional workflow adjustments in the outpatient and operating room settings given the abundance of COVID-19 virus in the upper aerodigestive tract. As the reverse-surge best practices are still under development, open communication between otolaryngology colleagues and health system leadership is paramount to optimize efficiency and maintain an adequate measure of safety for patients and our health care teams.


Assuntos
COVID-19/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Controle de Infecções/métodos , Otolaringologia/métodos , Pandemias , COVID-19/diagnóstico , COVID-19/transmissão , Teste para COVID-19 , Pessoal de Saúde , Humanos , Comunicação Interdisciplinar , Otorrinolaringologistas , Equipamento de Proteção Individual , Estados Unidos
16.
Otolaryngol Head Neck Surg ; 163(4): 712-713, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32515682

RESUMO

On March 11, 2020, the World Health Organization declared coronavirus disease 2019 a global pandemic. In addition to massive social disruption, this pandemic affected the traditional fellowship interview season for otolaryngology subspecialties, including head and neck surgical oncology, facial plastic and reconstructive surgery, laryngology, rhinology, neurotology, and pediatric otolaryngology. The impact on the fellowship interview process, from the standpoint of the institution and the applicant, necessitated the use of alternative interview processes. This change may alter the future of how interviews and the match proceed for years to come, with nontraditional methods of interviewing becoming a mainstay. While the impact this pandemic has on the fellowship match process is not yet fully realized, this commentary aims to discuss the challenges faced on both sides of the equation and to offer solutions during these unprecedented times.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Transmissão de Doença Infecciosa/prevenção & controle , Educação de Pós-Graduação em Medicina/organização & administração , Internato e Residência/métodos , Otolaringologia/educação , Pandemias , Pneumonia Viral/epidemiologia , COVID-19 , Infecções por Coronavirus/transmissão , Humanos , Pneumonia Viral/transmissão , SARS-CoV-2
17.
Laryngoscope Investig Otolaryngol ; 5(3): 552-559, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32596500

RESUMO

OBJECTIVES: To determine whether functional and anatomical outcomes following suture neurorrhaphy are improved by the addition of electrical stimulation with or without the addition of polyethylene glycol (PEG). METHODS: In a rat model of facial nerve injury, complete facial nerve transection and repair was performed via (a) suture neurorrhaphy alone, (b) neurorrhaphy with the addition of brief (30 minutes) intraoperative electrical stimulation, or (c) neurorrhaphy with the addition electrical stimulation and PEG. Functional recovery was assessed weekly for 16 weeks. At 16 weeks postoperatively, motoneuron survival, amount of regrowth, and specificity of regrowth were assessed by branch labeling and tissue analysis. RESULTS: The addition of brief intraoperative electrical stimulation improved all functional outcomes compared to suturing alone. The addition of PEG to electrical stimulation impaired this benefit. Motoneuron survival, amount of regrowth, and specificity of regrowth were unaltered at 16 weeks postoperative in all treatment groups. CONCLUSION: The addition of brief intraoperative electrical stimulation to neurorrhaphy in this rodent model shows promising neurological benefit in the surgical repair of facial nerve injury. LEVEL OF EVIDENCE: Animal study.

18.
Nature ; 582(7812): 399-404, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32494013

RESUMO

The skin is a multilayered organ, equipped with appendages (that is, follicles and glands), that is critical for regulating body temperature and the retention of bodily fluids, guarding against external stresses and mediating the sensation of touch and pain1,2. Reconstructing appendage-bearing skin in cultures and in bioengineered grafts is a biomedical challenge that has yet to be met3-9. Here we report an organoid culture system that generates complex skin from human pluripotent stem cells. We use stepwise modulation of the transforming growth factor ß (TGFß) and fibroblast growth factor (FGF) signalling pathways to co-induce cranial epithelial cells and neural crest cells within a spherical cell aggregate. During an incubation period of 4-5 months, we observe the emergence of a cyst-like skin organoid composed of stratified epidermis, fat-rich dermis and pigmented hair follicles that are equipped with sebaceous glands. A network of sensory neurons and Schwann cells form nerve-like bundles that target Merkel cells in organoid hair follicles, mimicking the neural circuitry associated with human touch. Single-cell RNA sequencing and direct comparison to fetal specimens suggest that the skin organoids are equivalent to the facial skin of human fetuses in the second trimester of development. Moreover, we show that skin organoids form planar hair-bearing skin when grafted onto nude mice. Together, our results demonstrate that nearly complete skin can self-assemble in vitro and be used to reconstitute skin in vivo. We anticipate that our skin organoids will provide a foundation for future studies of human skin development, disease modelling and reconstructive surgery.


Assuntos
Cabelo/citologia , Cabelo/crescimento & desenvolvimento , Organoides/citologia , Células-Tronco Pluripotentes/citologia , Pele/citologia , Animais , Ectoderma/citologia , Feminino , Cabelo/transplante , Cor de Cabelo , Folículo Piloso/citologia , Folículo Piloso/crescimento & desenvolvimento , Folículo Piloso/inervação , Folículo Piloso/transplante , Cabeça , Xenoenxertos , Humanos , Camundongos , Camundongos Nus , Organoides/crescimento & desenvolvimento , Organoides/inervação , Organoides/transplante , RNA-Seq , Análise de Célula Única , Pele/crescimento & desenvolvimento , Pele/inervação , Transplante de Pele
19.
Otolaryngol Head Neck Surg ; 163(1): 145-150, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32423283

RESUMO

OBJECTIVE: The primary mode of viral transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is thought to occur through the spread of respiratory droplets. The objective of this study was to investigate droplet and splatter patterns resulting from common endoscopic endonasal procedures. STUDY DESIGN: Cadaver simulation series. SETTING: Dedicated surgical laboratory. SUBJECTS AND METHODS: After instilling cadaver head specimens (n = 2) with fluorescein solution, endoscopic endonasal procedures were systematically performed to evaluate the quantity, size, and distance of droplets and splatter following each experimental condition. RESULTS: There were no observable fluorescein droplets or splatter noted in the measured surgical field in any direction after nasal endoscopy, septoplasty with microdebrider-assisted turbinoplasty, cold-steel functional endoscopic sinus surgery (FESS), and all experimental conditions using an ultrasonic aspirator. Limited droplet spread was noted with microdebrider FESS (2 droplets, <1 mm in size, within 10 cm), drilling of the sphenoid rostrum with a diamond burr (8, <1 mm, 12 cm), and drilling of the frontal beak with a cutting burr (5, <1 mm, 9 cm); however, the use of concurrent suction while drilling resulted in no droplets or splatter. The control condition of external activation of the drill resulted in gross contamination (11, 2 cm, 13 cm). CONCLUSION: Our results indicate that there is very little droplet generation from routine rhinologic procedures. The droplet generation from drilling was mitigated with the use of concurrent suction. Extreme caution should be used to avoid activating powered instrumentation outside of the nasal cavity, which was found to cause droplet contamination.


Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Transmissão de Doença Infecciosa/prevenção & controle , Endoscopia/métodos , Doenças Nasais/cirurgia , Pneumonia Viral/complicações , Rinoplastia/métodos , Treinamento por Simulação/métodos , COVID-19 , Cadáver , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Humanos , Doenças Nasais/complicações , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , SARS-CoV-2 , Resultado do Tratamento
20.
Otolaryngol Head Neck Surg ; 163(1): 112-113, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32423323

RESUMO

The utilization of telemedicine has seen a relatively slow progression over the past 50 years in the US health care system. Technological challenges limiting the ease of use of robust video platforms have been a major factor. Additionally, the perception by many health care providers that telehealth is reserved for only the rural population or that it provides limited value due to the inability to perform in-depth physical examinations contributes to the slow adoption. The COVID-19 pandemic, with its massive disruption in social interaction by way of "stay at home" orders, is serving as a catalyst for improving telehealth. Large health systems are investing millions of dollars and increasing telehealth visit numbers 100-fold to access patients. The "telehealth movement" is here to stay and will undoubtedly be incorporated into providers' daily lives years after the COVID-19 pandemic. By embracing virtual access to health care, otolaryngologists will be able to influence improvements to these systems and broaden access options for patient care well into the future.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Transmissão de Doença Infecciosa/prevenção & controle , Otorrinolaringologistas/normas , Otorrinolaringopatias/complicações , Pandemias , Pneumonia Viral/epidemiologia , Telemedicina/tendências , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/transmissão , Humanos , Otorrinolaringopatias/terapia , Pneumonia Viral/complicações , Pneumonia Viral/transmissão , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...