Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Prostate Cancer Prostatic Dis ; 26(3): 543-551, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36209237

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is used to detect the prostate index lesion before targeted biopsy. However, the number of biopsy cores that should be obtained from the index lesion is unclear. The aim of this study is to analyze how many MRI-targeted biopsy cores are needed to establish the most relevant histopathologic diagnosis of the index lesion and to build a prediction model. METHODS: We retrospectively included 451 patients who underwent 10-core systematic prostate biopsy and MRI-targeted biopsy with sampling of at least three cores from the index lesion. A total of 1587 biopsy cores were analyzed. The core sampling sequence was recorded, and the first biopsy core detecting the most relevant histopathologic diagnosis was identified. In a subgroup of 261 patients in whom exactly three MRI-targeted biopsy cores were obtained from the index lesion, we generated a prediction model. A nonparametric Bayes classifier was trained using the PI-RADS score, prostate-specific antigen (PSA) density, lesion size, zone, and location as covariates. RESULTS: The most relevant histopathologic diagnosis of the index lesion was detected by the first biopsy core in 331 cases (73%), by the second in 66 cases (15%), and by the third in 39 cases (9%), by the fourth in 13 cases (3%), and by the fifth in two cases (<1%). The Bayes classifier correctly predicted which biopsy core yielded the most relevant histopathologic diagnosis in 79% of the subjects. PI-RADS score, PSA density, lesion size, zone, and location did not independently influence the prediction model. CONCLUSION: The most relevant histopathologic diagnosis of the index lesion was made on the basis of three MRI-targeted biopsy cores in 97% of patients. Our classifier can help in predicting the first MRI-targeted biopsy core revealing the most relevant histopathologic diagnosis; however, at least three MRI-targeted biopsy cores should be obtained regardless of the preinterventionally assessed covariates.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Antígeno Prostático Específico , Estudos Retrospectivos , Teorema de Bayes , Biópsia Guiada por Imagem/métodos
2.
Rofo ; 195(2): 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36063835

RESUMO

PURPOSE: Preprocedural computed tomography (CT) imaging before transcatheter aortic valve implantation/replacement (TAVI/TAVR) requires high diagnostic accuracy without motion artifacts. The aim of this retrospective study is to compare the image quality of a high-pitch non-electrocardiography (ECG)-gated CT protocol used in patients with atrial tachyarrhythmias with a prospectively ECG-gated CT protocol used in patients with sinus rhythm. MATERIALS AND METHODS: We retrospectively included 108 patients who underwent preprocedural CT imaging before TAVI/TAVR. 52 patients with sinus rhythm were imaged using a prospectively ECG-gated protocol (Group A), and 56 patients with atrial tachyarrhythmias were imaged using the high-pitch non-ECG-gated protocol (Group B). Image quality was rated subjectively by two experienced radiologists and assessed by objective parameters including radiation dose, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) at the levels of the aortic root and abdominal aorta. RESULTS: Subjective image quality was equally good with both CT protocols, and interrater agreement was substantial in both groups but tended to be higher in Group B at the level of the aortic root (Group A: κw = 0.644, Group B: κw = 0.741). With the high-pitch non-ECG-gated CT protocol, image noise was significantly increased (p = 0.001), whereas the SNR, CNR, and radiation dose were significantly decreased (p = 0.002, p = 0.003, and p < 0.001, respectively) at the level of the aortic root compared to the prospectively ECG-gated CT protocol. CONCLUSION: The high-pitch non-ECG-gated protocol yields images with similar subjective image quality compared with the prospectively ECG-gated CT protocol and allows motion-free assessment of the aortic root for accurate TAVI/TAVR planning. The high-pitch non-ECG-gated protocol may be used as an alternative for preprocedural CT imaging in patients with atrial tachyarrhythmias. KEY POINTS: · In patients with atrial tachyarrhythmias, a high-pitch non-ECG-gated CT protocol achieves similar subjective image quality compared to a prospective ECG-gated CT protocol.. · At the level of the aortic root, image noise is significantly increased, whereas SNR and CNR are significantly decreased using the high-pitch non-ECG-gated protocol.. · Radiation dose is reduced by 55 % using the high-pitch non-ECG-gated protocol.. CITATION FORMAT: · Shnayien S, Beetz N, Bressem KK et al. Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR. Fortschr Röntgenstr 2023; 195: 139 - 147.


Assuntos
Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Meios de Contraste , Estudos Retrospectivos , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
3.
Sci Rep ; 12(1): 15333, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36097197

RESUMO

Patients with Marfan syndrome and related disorders are at risk for aortic dissection and aortic rupture and therefore require appropriate monitoring. Computed tomography (CT) and transthoracic echocardiography (TTE) are routinely used for initial diagnosis and follow-up. The purpose of this study is to compare whole-heart CT and TTE aortic measurement for initial work-up, 2-year follow-up, and detection of progressive aortic enlargement. This retrospective study included 95 patients diagnosed with Marfan syndrome or a related disorder. All patients underwent initial work-up including aortic diameter measurement using both electrocardiography-triggered whole-heart CT and TTE. Forty-two of these patients did not undergo aortic repair after initial work-up and were monitored by follow-up imaging within 2 years. Differences between the two methods for measuring aortic diameters were compared using Bland-Altman plots. The acceptable clinical limit of agreement (acLOA) for initial work-up, follow-up, and progression within 2 years was predefined as < ± 2 mm. Bland-Altman analysis revealed a small bias of 0.2 mm with wide limits of agreement (LOA) from + 6.3 to - 5.9 mm for the aortic sinus and a relevant bias of - 1.6 mm with wide LOA from + 5.6 to - 8.9 mm for the ascending aorta. Follow-up imaging yielded a small bias of 0.5 mm with a wide LOA from + 6.7 to - 5.8 mm for the aortic sinus and a relevant bias of 1.1 mm with wide LOA from + 8.1 to - 10.2 mm for the ascending aorta. Progressive aortic enlargement at follow-up was detected in 57% of patients using CT and 40% of patients using TTE. Measurement differences outside the acLOA were most frequently observed for the ascending aorta. Whole-heart CT and TTE measurements show good correlation, but the frequency of measurement differences outside the acLOA is high. TTE systematically overestimates aortic diameters. Therefore, whole-heart CT may be preferred for aortic monitoring of patients with Marfan syndrome and related disorders. TTE remains an indispensable imaging tool that provides additional information not available with CT.


Assuntos
Síndrome de Marfan , Ecocardiografia/métodos , Seguimentos , Humanos , Síndrome de Marfan/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
J Clin Med ; 11(9)2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-35566483

RESUMO

Pancreatic cancer is the seventh leading cause of cancer death in both sexes. The aim of this study is to analyze baseline CT body composition using artificial intelligence to identify possible imaging predictors of survival. We retrospectively included 103 patients. First, the presence of surgical treatment and cut-off values for sarcopenia and obesity served as independent variates. Second, the presence of surgery, subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), and skeletal muscle index (SMI) served as independent variates. Cox regression analysis was performed for 1-year, 2-year, and 3-year survival. Possible differences between patients undergoing surgical versus nonsurgical treatment were analyzed. Presence of surgery significantly predicted 1-year, 2-year, and 3-year survival (p = 0.01, <0.001, and <0.001, respectively). Across the follow-up periods of 1-year, 2-year, and 3-year survival, the presence of sarcopenia became an equally important predictor of survival (p = 0.25, 0.07, and <0.001, respectively). Additionally, increased VAT predicted 2-year and 3-year survival (p = 0.02 and 0.04, respectively). The impact of sarcopenia on 3-year survival was higher in the surgical treatment group (p = 0.02 and odds ratio = 2.57) compared with the nonsurgical treatment group (p = 0.04 and odds ratio = 1.92). Fittingly, a lower SMI significantly affected 3-year survival only in patients who underwent surgery (p = 0.02). Especially if surgery is performed, AI-derived sarcopenia and reduced muscle mass are unfavorable imaging predictors.

5.
Rofo ; 194(8): 852-861, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35545106

RESUMO

PURPOSE: To analyze possible differences in the inter-reader variability between PI-RADS version 2 (v2) and version 2.1 (v2.1) for the classification of prostate lesions using multiparametric MRI (mpMRI) of the prostate. METHODS: In this retrospective and randomized study, 239 annotated and histopathologically correlated prostate lesions (104 positive and 135 negative for prostate cancer) were rated twice by three experienced uroradiologists using PI-RADS v2 and v2.1 with an interval of at least two months between readings. Results were tabulated across readers and reading timepoints and inter-reader variability was determined using Fleiss' kappa (κ). Thereafter, an additional analysis of the data was performed in which PI-RADS scores 1 and 2 were combined, as they have the same clinical consequences. RESULTS: PI-PI-RADS v2.1 showed better inter-reader agreement in the peripheral zone (PZ), but poorer inter-reader agreement in the transition zone (TZ) (PZ: κ = 0.63 vs. κ = 0.58; TZ: κ = 0.47 vs. κ = 0.57). When PI-RADS scores 1 and 2 were combined, the use of PI-RADS v2.1 resulted in almost perfect inter-reader agreement in the PZ and substantial agreement in the TZ (PZ: κ = 0.81; TZ: κ = 0.80). CONCLUSION: PI-RADS v2.1 improves inter-reader agreement in the PZ. New differences in inter-reader agreement were mainly the result of the assignment of PI-RADS v2.1 scores 1 and 2 to lesions in the TZ. Combining scores 1 and 2 improved inter-reader agreement both in the TZ and in the PZ, indicating that refined definitions may be warranted for these PI-RADS scores. KEY POINTS: · PI-RADSv2.1 improves inter-reader agreement in the PZ but not in the TZ.. · New differences derived from PI-RADSv2.1 scores 1 and 2 in the TZ.. · Combined PI-RADSv2.1 scores of 1 and 2 yielded better inter-reader agreement.. · PI-RADSv2.1 appears to provide more precise description of lesions in the PZ.. · Improved inter-reader agreement in the PZ stresses the importance of appropriate lexicon description.. CITATION FORMAT: · Beetz N, Haas M, Baur A et al. Inter-Reader Variability Using PI-RADS v2 Versus PI-RADS v2.1: Most New Disagreement Stems from Scores 1 and 2. Fortschr Röntgenstr 2022; 194: 852 - 861.


Assuntos
Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Biomedicines ; 10(3)2022 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-35327356

RESUMO

The Eurotransplant Senior Program allocates kidneys to elderly transplant patients. The aim of this retrospective study is to investigate the use of computed tomography (CT) body composition using artificial intelligence (AI)-based tissue segmentation to predict patient and kidney transplant survival. Body composition at the third lumbar vertebra level was analyzed in 42 kidney transplant recipients. Cox regression analysis of 1-year, 3-year and 5-year patient survival, 1-year, 3-year and 5-year censored kidney transplant survival, and 1-year, 3-year and 5-year uncensored kidney transplant survival was performed. First, the body mass index (BMI), psoas muscle index (PMI), skeletal muscle index (SMI), visceral adipose tissue (VAT), and subcutaneous adipose tissue (SAT) served as independent variates. Second, the cut-off values for sarcopenia and obesity served as independent variates. The 1-year uncensored and censored kidney transplant survival was influenced by reduced PMI (p = 0.02 and p = 0.03, respectively) and reduced SMI (p = 0.01 and p = 0.03, respectively); 3-year uncensored kidney transplant survival was influenced by increased VAT (p = 0.04); and 3-year censored kidney transplant survival was influenced by reduced SMI (p = 0.05). Additionally, sarcopenia influenced 1-year uncensored kidney transplant survival (p = 0.05), whereas obesity influenced 3-year and 5-year uncensored kidney transplant survival. In summary, AI-based body composition analysis may aid in predicting short- and long-term kidney transplant survival.

7.
Dentomaxillofac Radiol ; 51(1): 20210168, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34233509

RESUMO

OBJECTIVES: The Neck Imaging Reporting and Data System (NI-RADS) is an increasingly utilized risk stratification tool for imaging surveillance after treatment for head and neck cancer. This study aims to measure the impact of supervision by subspecialized radiologists on diagnostic accuracy of NI-RADS when initial reading is performed by residents. METHODS: 150 CT and MRI datasets were initially read by two trained residents, and then supervised by two subspecialized radiologists. Recurrence rates by NI-RADS category were calculated, and receiver operating characteristic (ROC) curves were plotted. After dichotomization of the NI-RADS system (category 1 vs categories 2 + 3+4 and categories 1 + 2 vs 3 + 4), sensitivity, specificity, positive and negative predictive value were calculated. RESULTS: 26% of the reports were modified by the supervising radiologists. Area under the curve of ROC plots values of the supervision session were higher than those of the initial reading session for both the primary site (0.89 vs 0.86) and the neck (0.94 vs 0.91), but the difference was not statistically significant. For dichotomized NI-RADS category assignments, differences between the initial reading and the supervision session were statistically significant regarding specificity and PPV for the primary site (1 + 2 vs 3 + 4 and 1 vs 2 + 3+4) or even for both sites combined (1 vs 2 + 3+4). CONCLUSION: NI-RADS enables trained resident radiologists to report surveillance imaging in patients with treated oral squamous cell carcinoma with high discriminatory power. Additional supervision by a subspecialized head and neck radiologist particularly improves specificity of radiological reports.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Neoplasias Bucais/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Carcinoma de Células Escamosas de Cabeça e Pescoço
8.
Cell Death Dis ; 12(12): 1162, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34911941

RESUMO

Resistance against radio(chemo)therapy-induced cell death is a major determinant of oncological treatment failure and remains a perpetual clinical challenge. The underlying mechanisms are manifold and demand for comprehensive, cancer entity- and subtype-specific examination. In the present study, resistance against radiotherapy was systematically assessed in a panel of human head-and-neck squamous cell carcinoma (HNSCC) cell lines and xenotransplants derived thereof with the overarching aim to extract master regulators and potential candidates for mechanism-based pharmacological targeting. Clonogenic survival data were integrated with molecular and functional data on DNA damage repair and different cell fate decisions. A positive correlation between radioresistance and early induction of HNSCC cell senescence accompanied by NF-κB-dependent production of distinct senescence-associated cytokines, particularly ligands of the CXCR2 chemokine receptor, was identified. Time-lapse microscopy and medium transfer experiments disclosed the non-cell autonomous, paracrine nature of these mechanisms, and pharmacological interference with senescence-associated cytokine production by the NF-κB inhibitor metformin significantly improved radiotherapeutic performance in vitro and in vivo. With regard to clinical relevance, retrospective analyses of TCGA HNSCC data and an in-house HNSCC cohort revealed that elevated expression of CXCR2 and/or its ligands are associated with impaired treatment outcome. Collectively, our study identifies radiation-induced tumor cell senescence and the NF-κB-dependent production of distinct senescence-associated cytokines as critical drivers of radioresistance in HNSCC whose therapeutic targeting in the context of multi-modality treatment approaches should be further examined and may be of particular interest for the subgroup of patients with elevated expression of the CXCR2/ligand axis.


Assuntos
Senescência Celular , Neoplasias de Cabeça e Pescoço , Tolerância a Radiação , Receptores de Interleucina-8B , Carcinoma de Células Escamosas de Cabeça e Pescoço , Linhagem Celular Tumoral , Citocinas , Regulação Neoplásica da Expressão Gênica , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Ligantes , NF-kappa B , Receptores de Interleucina-8B/metabolismo , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia
9.
Diagnostics (Basel) ; 11(11)2021 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-34829501

RESUMO

State-of-the-art technology in Computed Tomography (CT) includes iterative reconstruction algorithms (IR) and metal artefact reduction (MAR) techniques. The objective of the study is to show the benefits of this technology for the detection of primary and recurrent head and neck cancer. A total of 131 patients underwent contrast-enhanced CT for diagnosis of primary and recurrent Head and Neck cancer; 110 patients were included. All scans were reconstructed using iterative reconstruction, and metal artifact reduction was applied when indicated. Tumor detectability was evaluated dichotomously. Histopathological findings were used as a standard of reference. Data were analyzed retrospectively, statistics was performed through diagnostic test characteristics. State-of-the-art Head and Neck CT showed a sensitivity of 0.83 (95% CI; 0.61-0.95) with 0.93 specificity (95% CI; 0.84-0.98) for primary tumor detection. Recurrent tumors were identified with a 0.94 sensitivity (95% CI; 0.71-0.99) and 0.93 specificity (95% CI; 0.84-0.98) in this study. Conclusion: State-of-the-art reconstruction tools improve the diagnostic quality of Head and Neck CT, especially for recurrent tumor detection, compared with data published for standard CT. IR and MAR are easily implemented in routine clinical settings and improve image evaluation by reducing artifacts and image noise while lowering radiation exposure.

10.
J Cachexia Sarcopenia Muscle ; 12(4): 993-999, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34137512

RESUMO

BACKGROUND: Patients with Marfan syndrome are at risk for aortic enlargement and are routinely monitored by computed tomography (CT) imaging. The purpose of this study is to analyse body composition using artificial intelligence (AI)-based tissue segmentation in patients with Marfan syndrome in order to identify possible predictors of progressive aortic enlargement. METHODS: In this study, the body composition of 25 patients aged ≤50 years with Marfan syndrome and no prior aortic repair was analysed at the third lumbar vertebra (L3) level from a retrospective dataset using an AI-based software tool (Visage Imaging). All patients underwent electrocardiography-triggered CT of the aorta twice within 2 years for suspected progression of aortic disease, suspected dissection, and/or pre-operative evaluation. Progression of aortic enlargement was defined as an increase in diameter at the aortic sinus or the ascending aorta of at least 2 mm. Patients meeting this definition were assigned to the 'progressive aortic enlargement' group (proAE group) and patients with stable diameters to the 'stable aortic enlargement' group (staAE group). Statistical analysis was performed using the Mann-Whitney U test. Two possible body composition predictors of aortic enlargement-skeletal muscle density (SMD) and psoas muscle index (PMI)-were analysed further using multivariant logistic regression analysis. Aortic enlargement was defined as the dependent variant, whereas PMI, SMD, age, sex, body mass index (BMI), beta blocker medication, and time interval between CT scans were defined as independent variants. RESULTS: There were 13 patients in the proAE group and 12 patients in the staAE group. AI-based automated analysis of body composition at L3 revealed a significantly increased SMD measured in Hounsfield units (HUs) in patients with aortic enlargement (proAE group: 50.0 ± 8.6 HU vs. staAE group: 39.0 ± 15.0 HU; P = 0.03). PMI also trended towards higher values in the proAE group (proAE group: 6.8 ± 2.3 vs. staAE group: 5.6 ± 1.3; P = 0.19). Multivariate logistic regression revealed significant prediction of aortic enlargement for SMD (P = 0.05) and PMI (P = 0.04). CONCLUSIONS: Artificial intelligence-based analysis of body composition at L3 in Marfan patients is feasible and easily available from CT angiography. Analysis of body composition at L3 revealed significantly higher SMD in patients with progressive aortic enlargement. PMI and SMD significantly predicted aortic enlargement in these patients. Using body composition as a predictor of progressive aortic enlargement may contribute information for risk stratification regarding follow-up intervals and the need for aortic repair.


Assuntos
Síndrome de Marfan , Músculos Psoas , Aorta/diagnóstico por imagem , Inteligência Artificial , Composição Corporal , Humanos , Síndrome de Marfan/diagnóstico por imagem , Músculos Psoas/diagnóstico por imagem , Estudos Retrospectivos
11.
Clin Hemorheol Microcirc ; 78(1): 93-101, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33554889

RESUMO

BACKGROUND: Post-therapeutic tissue is bradytrophic and thus has low perfusion values in PCT. In contrast, malignant tissue is expected to show higher perfusion values as cancer growth partially depends on angiogenesis. OBJECTIVES: This prospective study investigates perfusion computed tomography (PCT) for the post-therapeutic detection of cancer in the head and neck region. METHODS: 85 patients underwent PCT for 1) initial work-up of head and neck cancer (HNC; n=22) or 2) for follow-up (n=63). Regions of interest (ROIs) were placed in confirmed tumour, a corresponding location of benign tissue, and reference tissue. Perfusion was calculated using a single input maximum slope algorithm. Statistical analysis was performed with the Mann-Whitney U-test. RESULTS: PCT allowed significant differentiation of malignant tissue from post-therapeutic tissue after treatment for HNC (p=0.018). Significance was even greater after normalization of perfusion values (p=0.007). PCT allowed highly significant differentiation of HNC from reference tissue (p<0.001). CONCLUSIONS: PCT provides significantly distinct perfusion values for malignant and benign as well as post-therapeutically altered tissue in the head and neck area, thus allowing differentiation of cancer from healthy tissue. Our results show that PCT in conjunction with a standard algorithm is a potentially powerful HNC diagnostic tool.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Diferenciação Celular , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
AJR Am J Roentgenol ; 217(1): 198-206, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32876497

RESUMO

BACKGROUND. Imaging surveillance is important for the early diagnosis of recurrence after definitive treatment of oral squamous cell carcinoma (OSCC). The Neck Imaging Reporting and Data System (NI-RADS) includes a standardized template for surveillance imaging and categorizes probability of recurrence at the primary site and in the neck (cervical lymph nodes) by assigning categories of 1 (no evidence of recurrence), 2 (low suspicion, subdivided into 2a and 2b for the primary site), 3 (high suspicion), and 4 (definite recurrence). OBJECTIVE. The aim of this study was to determine the rate of locoregional and nodal OSCC recurrence stratified by NI-RADS category among patients undergoing surveillance CT or MRI. METHODS. This retrospective study included 158 patients enrolled in an institutional surveillance program after resection of OSCC with curative intent. A total of 503 contrast-enhanced CT or MRI examinations performed during surveillance were evaluated. Each examination was randomly assigned to one of four radiologists with expertise in head and neck imaging, who provided NI-RADS categories for the primary site and the neck (1006 assigned NI-RADS categories). NI-RADS performance in identifying recurrence was assessed by ROC curve analysis. All four readers evaluated 50 randomly assigned cases to determine interreader agreement by use of the Kendall W statistic. RESULTS. Cancer recurrence was confirmed in 7.6% (38/503) of cases for the primary site and in 6.2% (31/503) for the neck. For the primary site, recurrence rates were 1.0% in NI-RADS category 1, 7.1% in category 2a, 5.6% in category 2b, 66.7% in category 3, and 100.0% in category 4. For the neck, recurrence rates were 0.5% in category 1, 7.0% in category 2, 80.0% in category 3, and 100.0% in category 4. NI-RADS had AUC values of 0.934 for the primary site and 0.959 for the neck. Interreader agreement was 0.67 for the primary site and 0.81 for the neck. CONCLUSION. NI-RADS offers excellent discriminatory power in detection of OSCC recurrence, both for the primary site and the neck. CLINICAL IMPACT. Radiologists and maxillofacial surgeons should implement NI-RADS in surveillance regimens for postoperative OSCC to help detect recurrences in an effective and standardized manner using imaging.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Bucais/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Sistemas de Informação em Radiologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca/diagnóstico por imagem , Boca/cirurgia , Neoplasias Bucais/cirurgia , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia
13.
Clin Hemorheol Microcirc ; 76(2): 171-177, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32925013

RESUMO

BACKGROUND: Detecting local tumor recurrence from post-treatment changes in head and neck cancer (HNC) remains a challenge. Based on the hypothesis that post-therapeutically altered tissue is bradytroph, lower perfusion values are expected in perfusion CT (PCT) while higher perfusion values are expected in recurrent malignant tissue. OBJECTIVES: This prospective study investigates PCT for post-treatment recurrent HNC detection with a maximum slope algorithm. METHODS: A total of 80 patients who received PCT of the head and neck for post-therapy follow-up, of which 63 had no tumor recurrence and 17 presented a histopathologically confirmed recurrence were examined. Regions of interest were placed in the location of the initial tumor, in reference ipsilateral nuchal muscle tissue and the corresponding internal carotid artery. Perfusion was calculated using a single-input maximum slope algorithm. RESULTS: With PCT, recurrent HNC can be differentiated from post-treatment tissue (p < 0.05). It further allows delineating recurrent tumor tissue from benign nuchal tissue of reference (p < 0.05). PCT data of patients with and without recurrent HNC are comparable as perfusion values of reference tissues in patients with and without HNC do not differ (p > 0.05). CONCLUSIONS: PCT in combination with a commercially available maximum slope algorithm offers radiologists a reliable imaging tool to detect recurrent head and neck cancer within post-therapeutically altered tissue.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Estudos Prospectivos
14.
Rofo ; 192(12): 1174-1182, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32299112

RESUMO

PURPOSE: To retrospectively investigate the effectiveness of a novel 3-phase protocol for computed tomography (CT) before transcatheter aortic valve implantation/transcatheter aortic valve replacement (TAVI/TAVR) in terms of radiation dose and image quality. MATERIALS AND METHODS: A total of 107 nonrandomized patients (81 ±â€Š7.4 years) scheduled for TAVI/TAVR underwent preprocedural CT on an 80-row CT scanner. 55 patients underwent a combined ECG-synchronized spiral scan of the chest and non-ECG-synchronized spiral scan of the abdomen/pelvis as recommended by the Society of Cardiovascular Computed Tomography (SCCT). 52 patients underwent an updated 3-phase variable helical pitch (vHP3) protocol combining a non-ECG-synchronized spiral scan of the upper thoracic aperture, followed by a prospective ECG-synchronized spiral scan of the heart, and a non-ECG-synchronized abdominal/pelvic spiral scan. The radiation dose was determined from an automatically generated protocol based on the CT dose index (CTDI). Objective image quality in terms of vessel attenuation and image noise was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was evaluated using a 4-point scale and compared for interrater agreement using Cohen's weighted kappa coefficient (κw). All data were compared and statistically analyzed. RESULTS: Use of the novel 3-phase vHP3 protocol reduced the dose-length product (DLP) from 1256.58 ±â€Š619.05 mGy*cm to 790.90 ±â€Š238.15 mGy*cm, reducing the effective dose (E) from 21.36 ±â€Š10.52 mSv to 13.44 ±â€Š4.05 mSv and size-specific dose estimates (SSDE) from 20.85 ±â€Š7.29 mGy to 13.84 ± 2.94 mGy (p < 0.001). There were no significant differences in objective and subjective image quality between the two protocols and between the two readers. CONCLUSION: The novel 3-phase vHP3 protocol significantly reduces the radiation dose of preprocedural TAVI/TAVR CT without a loss of image quality. KEY POINTS: · The use of a novel 3-phase protocol for preprocedural TAVI/TAVR CT reduces radiation dose by 37 % compared to a combined ECG-synchronized and non-ECG-synchronized spiral CT protocol.. · Objective image quality remains unaffected as image noise, SNR, and CNR did not differ significantly between the two protocols. The average attenuation of the aortic root and abdominal aorta exceeded 450 HU in both protocols.. · The average subjective image quality ratings were good to excellent for both protocols with almost perfect to substantial interrater agreement.. CITATION FORMAT: · Shnayien S, Bressem KK, Beetz NL et al. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. Fortschr Röntgenstr 2020; 192: 1174 - 1182.


Assuntos
Cuidados Pré-Operatórios/métodos , Radiometria/métodos , Tomografia Computadorizada Espiral/métodos , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Feminino , Humanos , Masculino
15.
Sci Rep ; 9(1): 18506, 2019 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811190

RESUMO

After hepatic microwave ablation, the differentiation between fully necrotic and persistent vital tissue through contrast enhanced CT remains a clinical challenge. Therefore, there is a need to evaluate new imaging modalities, such as CT perfusion (CTP) to improve the visualization of coagulation necrosis. MWA and CTP were prospectively performed in five healthy pigs. After the procedure, the pigs were euthanized, and the livers explanted. Orthogonal histological slices of the ablations were stained with a vital stain, digitalized and the necrotic core was segmented. CTP maps were calculated using a dual-input deconvolution algorithm. The segmented necrotic zones were overlaid on the DICOM images to calculate the accuracy of depiction by CECT/CTP compared to the histological reference standard. A receiver operating characteristic analysis was performed to determine the agreement/true positive rate and disagreement/false discovery rate between CECT/CTP and histology. Standard CECT showed a true positive rate of 81% and a false discovery rate of 52% for display of the coagulation necrosis. Using CTP, delineation of the coagulation necrosis could be improved significantly through the display of hepatic blood volume and hepatic arterial blood flow (p < 0.001). The ratios of true positive rate/false discovery rate were 89%/25% and 90%/50% respectively. Other parameter maps showed an inferior performance compared to CECT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Micro-Ondas , Necrose , Algoritmos , Animais , Modelos Animais de Doenças , Reações Falso-Positivas , Perfusão , Curva ROC , Suínos
16.
Int J Hyperthermia ; 36(1): 1098-1107, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31724443

RESUMO

Background: Accurate lesion visualization after microwave ablation (MWA) remains a challenge. Computed tomography perfusion (CTP) has been proposed to improve visualization, but it was shown that different perfusion-models delivered different results on the same data set.Purpose: Comparison of different perfusion algorithms and identification of the algorithm enables for the best imaging of lesion after hepatic MWA.Materials and methods: 10 MWA with consecutive CTP were performed in healthy pigs. Parameter-maps were generated using a single-input-dual-compartment-model with Patlak's algorithm (PM), a dual-input-maximum-slope-model (DIMS), a dual-input-one-compartment-model (DIOC), a single-(SIDC) and dual-input-deconvolution-model (DIDC). Parameter-maps for hepatic arterial (AF) and portal venous blood flow (PF), mean transit time, hepatic blood volume (HBV) and capillary permeability were compared regarding the values of the normal liver tissue (NLT), lesion, contrast- and signal-to-noise ratios (SNR, CNR) and inter- and intrarater-reliability using the intraclass correlation coefficient, Bland-Altman plots and linear regression.Results: Perfusion values differed between algorithms with especially large fluctuations for the DIOC. A reliable differentiation of lesion margin appears feasible with parameter-maps of PF and HBV for most algorithms, except for the DIOC due to large fluctuations in PF. All algorithms allowed for a demarcation of the central necrotic zone based on hepatic AF and HBV. The DIDC showed the highest CNR and the best inter- and intrarater reliability.Conclusion: The DIDC appears to be the most feasible model to visualize margins and necrosis zones after microwave ablation, but due to high computational demand, a single input deconvolution algorithm might be preferable in clinical practice.


Assuntos
Técnicas de Ablação/métodos , Tomografia Computadorizada Quadridimensional/métodos , Micro-Ondas/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Algoritmos , Animais , Modelos Animais de Doenças , Humanos , Suínos
17.
Comput Biol Med ; 103: 161-166, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30384174

RESUMO

BACKGROUND: To evaluate whether Canon's Single-Energy Metal Artifact Reduction (SEMAR) algorithm can significantly improve subjective and objective image quality of patients with nonremovable dental hardware undergoing CT imaging of the oral cavity and oropharynx. MATERIALS AND METHODS: SEMAR was reconstructed from routine Adaptive Iterative Dose Reduction (AIDR) images in 154 patients (46 females and 108 males; mean age 66.3 ±â€¯10.5 years). Subjective SEMAR and AIDR image quality of the mouth floor, sublingual glands, lymphatic ring and overall impression were evaluated by two independent radiologists on a 6-point scale (1 = very good image quality, 6 = poor image quality) and compared to ratings of an oral and maxillofacial surgeon. Interrater agreement was assessed using the intraclass correlation coefficient (ICC). Objective image analysis was performed by placing regions of interest (ROIs) on the mouth floor and measuring CT attenuation in Hounsfield units (HU) and standard deviation (SD). RESULTS: SEMAR significantly improved subjective image quality in all evaluated structures for all raters (p < 0.001). Furthermore, SEMAR significantly reduced objective metal artifacts and image noise (p < 0.001). CONCLUSION: SEMAR significantly improved diagnostic quality of CT images of the oral cavity and oropharynx by reducing artifacts caused by dental hardware.


Assuntos
Artefatos , Prótese Dentária , Processamento de Imagem Assistida por Computador/métodos , Metais/química , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...