Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 5292, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438495

RESUMO

To evaluate the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00) and a diffractive trifocal IOL with + 2.17 D and + 3.25 D near addition (AcrySof IQ PanOptix TFNT00), we investigated the 10-week postoperative parameters after cataract surgery in which ZMB00 or TFNT00 lenses were implanted bilaterally from 2011 to 2020 (with a 3-month interval between implantation of the right and left lenses). The study included 1448 eyes of 724 patients. The diffractive bifocal group comprised 1326 eyes of 663 patients (aged 67.0 ± 7.8 years; females/males, 518/145), and the diffractive trifocal group comprised 122 eyes of 61 patients (aged 66.6 ± 7.3 years; females/males, 35/26). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Uncorrected near visual acuity and higher-order aberrations (ocular/internal, scaled to a pupil size of 4 mm) (Wavefront_4mm_postoperative_Ocular/Internal_Spherical) were significantly better in the bifocal group (p < 0.00068, Wald test). Uncorrected intermediate visual acuity, contrast sensitivity (6.3/4.0/2.5/1.6/1.0/0.7 degrees), and contrast sensitivity with glare (4.0/1.6/1.0/0.7 degrees) were significantly better in the trifocal group (p < 0.00068, Wald test).


Assuntos
Cristalino , Lentes Intraoculares , Lentes , Feminino , Masculino , Humanos , Olho Artificial , Córnea
2.
Cureus ; 16(1): e51675, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313883

RESUMO

The duration of several types of glaucoma surgery and reimbursement amounts per minute of surgery remain unknown. This study compared the surgical duration of glaucoma procedures (ab interno trabeculotomy, PreserFlo, ab externo trabeculotomy, bleb revision, EXPRESS, trabeculectomy, Ahmed, and the Baerveldt implant) and their reimbursement amounts in Japan. We retrospectively analyzed 30 consecutive surgeries of each type of glaucoma surgery. The reimbursement amount per surgical hour was calculated by subtracting the implant cost from the total medical fees. Amounts were converted to dollars based on an exchange rate of 1 USD = 133 JPY. The average surgical time was as follows: ab interno trabeculotomy, 7.8 ± 2.1; PreserFlo, 13.5 ± 4.0; ab externo trabeculotomy, 15.2 ± 4.1; bleb revision, 15.6 ± 2.3; EXPRESS, 16.9 ± 2.7; trabeculectomy, 18.5 ± 3.1; Ahmed, 35.8 ± 8.2; and Baerveldt, 39.2 ± 6.2. The reimbursement amounts after implant deduction were as follows: ab interno trabeculotomy, $1,089; PreserFlo, $1,538; ab externo trabeculotomy, $1,430; bleb revision, $259; EXPRESS, $1,600; trabeculectomy, $1,774; Ahmed, $1,600; and Baerveldt, $1,765. Reimbursement amounts per minute varied, with the highest and lowest for ab interno trabeculotomy and bleb revision at $140 per minute and $17 per minute, respectively. Reimbursement amounts per minute of surgery for eight types of glaucoma surgery vary by up to eightfold.

3.
PLoS One ; 18(7): e0288602, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37440544

RESUMO

We compared the visual performance of a bifocal intraocular lens (IOL) (ZMB00) and an extended-depth-of-focus (EDOF) IOL (ZXR00V) by evaluating postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZMB00 or ZXR00V implantation between 2011 and 2020. The right and left lenses were implanted within 3 months of each other. The study enrolled 1536 eyes of 768 patients; the ZMB00 group comprised 1326 eyes of 663 patients (age: 67.0 ± 7.8 years; female/male, 518/145), and the ZXR00V group comprised 210 eyes of 105 patients (age: 67.8 ± 6.9 years; female/male, 39/66). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations and pupil diameter, ensured statistical validity. Uncorrected near visual acuity, corrected near visual acuity, and near spectacle independence were significantly better in the ZMB00 group (p<0.00068, Wald test) than in the ZXR00V group. Contrast sensitivity (visual angle of the test target: 4.0°/2.5°/1.6°/1.0°/0.7°) and contrast sensitivity with glare (4.0°/2.5°/1.6°/1.0°/0.7°) were significantly better in the ZXR00V group (p<0.00068, Wald test) than in the ZMB00 group. Uncorrected intermediate visual acuity, contrast sensitivity with glare (6.3°), and 25-item National Eye Institute Visual Function Questionnaire (VFQ-25) scores for General Vision were slightly but significantly better in the ZXR00V group than in the ZMB00 group (p<0.05, Wald test). At high-performance levels, the two IOL groups had different characteristics regarding various visual performance parameters.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Óculos , Acuidade Visual , Refração Ocular , Satisfação do Paciente , Desenho de Prótese
4.
Sci Rep ; 13(1): 11348, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443278

RESUMO

This retrospective study examined the effect of the size of training data on the accuracy of machine learning-assisted SRK/T power calculation. Clinical records of 4800 eyes of 4800 Japanese patients with intraocular lenses (IOLs) were reviewed. A support vector regressor (SVR) was used for refining the SRK/T formula, and dataset sizes for training and evaluation were reduced from full to 1/64. The prediction errors from the postoperative refractions were calculated, and the proportion within ± 0.25 D, ± 0.50 D, and ± 1.00 D of errors were compared with those using full data. The influence of the difference in A-constant was also evaluated. Prediction errors within ± 0.50 D in the use of full data were obtained with the dataset of ≥ 150 eyes (P = 0.016), whereas the datasets of ≥ 300 eyes were required for the error within ± 0.25 D (P < 0.030). The prediction errors did not alter with the A-constant values among IOLs with open-loop haptics, except for IOLs with plated haptics. In conclusion, the accuracy of SVR-assisted SRK/T could be achieved with the training dataset of ≥ 150 eyes for the Japanese population, and the calculation was versatile for any open-looped IOLs.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Refração Ocular , Implante de Lente Intraocular , Acuidade Visual , Estudos Retrospectivos , Biometria , Óptica e Fotônica
5.
Sci Rep ; 12(1): 19394, 2022 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-36371596

RESUMO

We compared the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00 [Johnson & Johnson Surgical Vision]) and a rotationally asymmetric refractive IOL with + 1.5 D near addition (LS-313 MF15 [Teleon Surgical BV]) 10 weeks after cataract patients' last surgery for bilateral ZMB00 or LS-313 MF15 implantation between 2011 and 2020, with the lenses of each eye implanted within 3 months of each other. The ZMB00 and LS-313 MF15 groups comprised 1326 eyes of 663 patients (age: 67.0 ± 7.8 years; females/males, 518/145) and 448 eyes of 224 patients (73.6 ± 7.0 years; females/males, 125/99), respectively. A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Compared to LS-313 MF15, ZMB00 achieved significantly superior uncorrected near visual acuity, reduced higher-order aberrations (ocular/internal, scaled to a 4-mm pupil; Wavefront_4_post_Ocular_Total Higher-Order Aberration/Third/Fourth/Trefoil/Coma/Tetrafoil/Spherical, Wavefront_4_post_Internal_Astigmatism/Total Higher-Order Aberration/Third/Trefoil/Coma/Tetrafoil/Spherical), and superior distance and near spectacle independence (p < 0.00068, Wald test). Contrast sensitivity, measured without (visual angle of the test target: 6.3°/4.0°/2.5°/1.6°/1.0°/0.7°) or with glare (4.0°/2.5°/1.6°/1.0°/0.7°), was significantly better in the LS-313 MF15 than the ZMB00 group (p < 0.00068, Wald test).


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Astigmatismo/cirurgia , Implante de Lente Intraocular , Óculos , Coma , Refração Ocular , Transtornos da Visão/cirurgia , Desenho de Prótese
6.
Sci Rep ; 10(1): 19565, 2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33154534

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

7.
Sci Rep ; 10(1): 15490, 2020 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-32968124

RESUMO

To compare the visual performance of a monofocal intraocular lens (IOL) (ZCB00) and a multifocal IOL (ZMB00) of the same material and basic design, we evaluated postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZCB00 or ZMB00 implantation from December 13, 2010, to July 29, 2019, with the right and left lenses implanted within 3 months of each other. The study enrolled 2,230 eyes of 1,115 patients. The monofocal group comprised 904 eyes of 452 patients (72.3 ± 6.8 years; females/males, 268/184), and the multifocal group comprised 1,326 eyes of 663 patients (67.0 ± 7.8 years; females/males, 518/145). Contrast sensitivity (4.0/2.5/1.6/1.0/0.7 degrees), contrast sensitivity with glare (1.6/1.0/0.7 degrees), and the VFQ-25 score for driving at night were significantly better in the monofocal group (p < 0.00068, Wald test). Uncorrected intermediate/near visual acuity and near spectacle independence were significantly better in the multifocal group (p < 0.00068, Wald test). The two IOL groups had different characteristics in terms of contrast sensitivity, night-time driving, uncorrected intermediate/near visual acuity and near spectacle independence.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Acuidade Visual , Idoso , Sensibilidades de Contraste , Feminino , Humanos , Implante de Lente Intraocular , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...