Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Ann Thorac Surg ; 117(2): 336-343, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769702

RESUMO

BACKGROUND: The safety and effectiveness of the RelayPro endograft (Terumo Aortic) was assessed for the treatment of acute, complicated type B aortic dissection (TBAD). METHODS: A prospective pivotal trial analyzed a primary end point of all-cause mortality at 30 days. Secondary end points included technical success, major adverse events (disabling stroke, renal failure, and paraplegia/paralysis), endoleaks, patency, rupture, device integrity, false lumen perfusion, reinterventions, aortic expansion, and migration evaluated to 5 years. RESULTS: The study involved 22 United States centers and enrolled 56 patients (mean age, 59.5 ± 11.4 years) from 2017 to 2021; of whom, 73.2% were men and 53.6% were African American. TBAD was complicated by malperfusion of the kidneys (51.8%), lower extremities (35.7%), and viscera (33.9%), and rupture (10.7%). Dissection extended proximally to zones 1/2 (14.3%) and zone 3 (78.6%) and distally to the iliac arteries (67.3%). Most procedures were percutaneous (85.5%). Technical success was 100%. Median hospitalization was 7 days (interquartile range, 5-12 days). All-cause mortality at 30 days was 1.8% (1 of 56; upper 95% CI, 8.2%; P < .0001). Seven major adverse events occurred in 6 patients (10.7%), consisting of paraplegia (n = 3), paraparesis (n = 2), disabling stroke (n = 1), and renal failure (n = 1). All paraplegia/paraparesis resolved with lumbar drainage. Kaplan-Meier analysis estimated a freedom from major adverse events of 89.1% at each interval from 30 days to 3 years. There was 1 endoleak (Type Ia), 2 retrograde dissections, and aortic diameter growth occurred in 2. There has been no rupture, fistula, component separation, patency loss, stenosis, kinking, twisting, bird beak, loss of device integrity, or fracture. CONCLUSIONS: RelayPro is safe and effective in acute, complicated TBAD. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal , Acidente Vascular Cerebral , Masculino , Humanos , Estados Unidos , Pessoa de Meia-Idade , Idoso , Feminino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estudos Prospectivos , Resultado do Tratamento , Stents/efeitos adversos , Dissecção Aórtica/cirurgia , Endoleak/etiologia , Paraplegia/etiologia , Estudos Retrospectivos , Insuficiência Renal/etiologia , Acidente Vascular Cerebral/etiologia , Paraparesia/complicações , Procedimentos Endovasculares/efeitos adversos
2.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550124

RESUMO

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese
3.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
5.
JACC Case Rep ; 18: 101915, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37545687

RESUMO

We present a case of post-myocardial infarction free-wall rupture in a critically ill patient presenting to the emergency department. Through our case we highlight the prompt evaluation, diagnosis, and management necessary to improve survival in a patient with this life-threatening condition. (Level of Difficulty: Beginner.).

6.
Circ Cardiovasc Interv ; 16(5): e012655, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37192308

RESUMO

BACKGROUND: The LRT trial (Low-Risk Transcatheter Aortic Valve Replacement [TAVR]) demonstrated the safety and feasibility of TAVR in low-risk patients, with excellent 1- and 2-year outcomes. The objective of the current study is to provide the overall clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration at 4 years. METHODS: The prospective, multicenter LRT trial was the first Food and Drug Administration-approved investigational device exemption study to evaluate feasibility and safety of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis. Clinical outcomes and valve hemodynamics were documented annually through 4 years. RESULTS: A total of 200 patients were enrolled, and follow-up was available on 177 patients at 4 years. The rates of all-cause mortality and cardiovascular death were 11.9% and 3.3%, respectively. The stroke rate rose from 0.5% at 30 days to 7.5% at 4 years, and permanent pacemaker implantation rose from 6.5% at 30 days to 11.7% at 4 years. Endocarditis was detected in 2.5% of the cohort, with no new cases reported between 2 and 4 years. Transcatheter heart valve hemodynamics remained excellent post-procedure and were maintained (mean gradient 12.56±5.54 mm Hg and aortic valve area 1.69±0.52 cm2) at 4 years. At 30 days, HALT was observed in 14% of subjects who received a balloon-expandable transcatheter heart valve. There was no difference in valve hemodynamics between patients with and without HALT (mean gradient 14.94±5.01 mm Hg versus 12.3±5.57 mm Hg; P=0.23) at 4 years. The overall rate of structural valve deterioration was 5.8%, and there was no impact of HALT on valve hemodynamics, endocarditis, or stroke at 4 years. CONCLUSIONS: TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis was found to be safe and durable at 4 years. Structural valve deterioration rates were low irrespective of the type of valve, and the presence of HALT at 30 days did not affect structural valve deterioration, transcatheter valve hemodynamics, and stroke rate at 4 years. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02628899.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fatores de Risco , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Hemodinâmica , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Trombose/etiologia
7.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858660

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Mortalidade Hospitalar , Resultado do Tratamento , Coração
8.
Am J Cardiol ; 193: 1-18, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36857839

RESUMO

Since the first transcatheter delivery of an aortic valve prosthesis was performed by Cribier et al in 2002, the picture of aortic stenosis (AS) therapeutics has changed dramatically. Initiated from an indication of inoperable to high surgical risk, extending to intermediate and low risk, transcatheter aortic valve replacement (TAVR) is now an approved treatment for patients with severe, symptomatic AS across all the risk categories. The current evidence supports TAVR as a frontline therapy for treating severe AS. The crucial question remains concerning the subset of patients who still are not ideal candidates for TAVR because of certain inherent anatomic, nonmodifiable, and procedure-specific factors. Therefore, in this study, we focus on these scenarios and reasons for referring selected patients for surgical aortic valve replacement in 2023.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
9.
Am J Cardiol ; 192: 45-50, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36736012

RESUMO

Surgical aortic valve replacement (SAVR) remains the standard of care for patients with chronic severe aortic regurgitation (AR). The introduction of a dedicated transcatheter heart valve for AR has fueled interest in using transcatheter aortic valve replacement to treat patients with isolated AR. We aimed to characterize the profile and outcomes of patients with symptomatic severe AR who underwent isolated SAVR. We conducted a retrospective, observational study of patients who underwent isolated SAVR for symptomatic severe AR at our institution. The primary outcome was in-hospital all-cause mortality. Patients were followed up with 30-day clinical and echocardiographic assessment. A total of 979 patients who underwent SAVR for severe AR between January 2015 and June 2021 were screened for eligibility, of whom 112 patients (11.4%) underwent isolated SAVR for symptomatic severe AR and were included in this analysis. Approximately 25% of patients were deemed to be at intermediate or high risk (n = 26 of 112). The primary outcome occurred in 2.7% of patients (n = 3 of 112). In-hospital stroke occurred in 2.7% of patients (n = 3 of 112), and new-onset atrial fibrillation occurred in 32.1% (n = 36 of 112). At 30-day follow-up, all-cause mortality occurred in 3.6% of patients (n = 4 of 112), and 0.8% (1 of 112) had >mild AR. In conclusion, in a tertiary referral center, the number of patients who underwent isolated SAVR for pure AR represented a small fraction of the overall SAVR patients. The vast majority were low risk and younger when compared with patients with severe aortic stenosis. SAVR yielded excellent short-term mortality and echocardiographic improvements.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
10.
Int J Cardiol ; 371: 305-311, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272571

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SLT) is characterized on computed tomography (CT) imaging as hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM). How antithrombotic regimen type impacts SLT remains poorly understood. We evaluated how antithrombotic regimen type impacts SLT in low-risk subjects following transcatheter aortic valve implantation (TAVI). METHODS: This substudy is a post hoc analysis of the LRT 1.0 and 2.0 trials to assess SLT in subjects who underwent CT or transoesophageal echocardiogram (TOE) imaging at 30 days, stratified by antithrombotic regimen received (single antiplatelet therapy [SAPT], dual antiplatelet therapy [DAPT], or oral anticoagulation). We also utilized univariable logistic regression modelling to identify echocardiographic predictors of HALT. RESULTS: Rates of HALT, RELM, and HAM were all significantly lower with oral anticoagulation compared to SAPT or DAPT at 30 days (HALT: 2.6% vs 14.3% vs 17.2%, respectively, with p < 0.001; RELM: 1.8% vs 9.6% vs 13.1%, respectively, with p = 0.004; and HAM: 0.9% vs 8.5% vs 9.8%, respectively, with p = 0.011). Additionally, short-term oral anticoagulation was not associated with higher bleeding rates compared to SAPT or DAPT (0.8% vs. 1.8% vs. 3.6%, p = 0.291). The presence of HALT did not significantly impact echocardiographic haemodynamic parameters at 30 days. CONCLUSION: This is the largest study to date that evaluated the impact of different antithrombotic regimens on SLT in low-risk TAVI patients. Oral anticoagulation was associated with significantly lower rates of SLT at 30 days compared to DAPT or SAPT, and there was no apparent benefit of DAPT over SAPT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fibrinolíticos/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia
11.
Heart Rhythm O2 ; 3(4): 396-404, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097459

RESUMO

Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (∼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.

12.
Catheter Cardiovasc Interv ; 100(3): 404-412, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35723247

RESUMO

OBJECTIVES: Evaluate transcatheter heart valve (THV) geometry according to left ventricular outflow tract (LVOT) calcium degree and its impact on hemodynamics and outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a contemporary self-expanding THV. BACKGROUND: LVOT calcium remains challenging for contemporary THVs. LVOT calcium location and degree may affect THV deployment and impact flow patterns and shear stress, accelerating THV degeneration. METHODS: EPROMPT (CoreValve Evolut Pro Prospective Registry; NCT03423459) is a prospective, investigator-initiated, multicenter registry of patients undergoing TAVR using CoreValve Evolut PRO/PRO + THVs. A total of 107 patients were enrolled in EPROMPT's computed tomography (CT) cohort between January 2018 and October 2021. These patients underwent follow-up CT scan 30 days post-TAVR. We analyzed THV geometry and its interaction with the aortic root following deployment using 30-day post-TAVR CT in patients with none/mild versus moderate/severe LVOT calcium. RESULTS: Thirty-day THV inflows were less eccentric in the short axis in patients with none/mild versus moderate/severe LVOT calcium (1.16 ± 0.09 vs. 1.21 ± 0.12; p = 0.007). THV became more circular and was similar between both cohorts at the THV waist (1.08 ± 0.06 vs. 1.09 ± 0.11; p = 0.551), leaflet tips (1.03 ± 0.04 vs. 1.05 ± 0.09; p = 0.299), and THV outflow (1.04 ± 2.2 vs. 1.03 ± 2.7; p = 0.143). Thirty-day > mild paravalvular leak was low in both cohorts (1.5% vs. 2.4%; p = 0.724); mean gradients were similar (7.7 ± 3.6 vs. 7.7 ± 3.4 mmHg; p = 0.955). CONCLUSIONS: Despite inflow deformities observed in patients with moderate/severe LVOT calcium, Evolut PRO/PRO + conforms to elliptical aortic annuli, maintaining circularity and proper function at the leaflets and outflow, even in patients with moderate/severe LVOT calcium.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Cálcio , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
13.
EuroIntervention ; 18(5): e407-e416, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35321859

RESUMO

BACKGROUND: Given enough time, transcatheter heart valves (THVs) will degenerate and may require reintervention. Redo transcatheter aortic valve implantation (TAVI) is an attractive strategy but carries a risk of coronary obstruction. AIMS: We sought to predict how many TAVIs patients could undergo in their lifetime using computed tomography (CT) simulation. METHODS: We analysed paired CT scans (baseline and 30 days post-TAVI) from patients in the LRT trial and EPROMPT registry. We implanted virtual THVs on baseline CTs, comparing predicted valve-to-coronary (VTC) distances to 30-day CT VTC distances to evaluate the accuracy of CT simulation. We then simulated implantation of a second virtual THV within the first to estimate the risk of coronary obstruction due to sinus sequestration and the need for leaflet modification. RESULTS: We included 213 patients with evaluable paired CTs. There was good agreement between virtual (baseline) and actual (30 days) CT measurements. CT simulation of TAVI followed by redo TAVI predicted low coronary obstruction risk in 25.4% of patients and high risk, likely necessitating leaflet modification, in 27.7%, regardless of THV type. The remaining 46.9% could undergo redo TAVI so long as the first THV was balloon-expandable but would likely require leaflet modification if the first THV was self-expanding. CONCLUSIONS: Using cardiac CT simulation, it is possible to predict whether a patient can undergo multiple TAVI procedures in their lifetime. Those who cannot may prefer to undergo surgery first. CT simulation could provide a personalised lifetime management strategy for younger patients with symptomatic severe aortic stenosis and inform decision-making. CLINICALTRIALS: gov: NCT02628899; ClinicalTrials.gov: NCT03557242; ClinicalTrials.gov: NCT03423459.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34505737

RESUMO

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Cardiovasc Revasc Med ; 33: 1-6, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34253474

RESUMO

BACKGROUND: Most pivotal transcatheter aortic valve replacement (TAVR) trials have excluded patients with bicuspid aortic stenosis (AS). This study compared TAVR in low-risk patients with bicuspid AS to those with tricuspid AS, incorporating data from prospective trials. METHODS: We selected prospective US low-risk TAVR trials containing a bicuspid arm for this meta-analysis, examining outcomes at 30 days. Study results were pooled using a hierarchical Bayesian random-effects model. RESULTS: Included were 3 Food and Drug Administration (FDA)-approved investigational device exemption (IDE) trials that enrolled a total of 1810 low-risk patients with symptomatic severe AS for TAVR. We compared 380 bicuspid patients with 1430 tricuspid patients. Event rates at 30 days overall were low, with similar mortality (odds ratio [OR], 0.38; 95% credible interval [CrI]: 0.08, 1.78; I2, 0%), non-disabling stroke (OR, 0.45; 95% CrI: 0.15, 1.07; I2, 9%), and permanent pacemaker implantation (OR, 0.86; 95% CrI: 0.41, 1.47; I2, 59%). There were statistically significant differences in disabling stroke (OR, 0.16; 95% CrI: 0.01, 0.90; I2, NA) and coronary obstruction (OR, 0.21; 95% CrI: 0.05, 0.91) that disappeared after sensitivity analysis by adding a single event to the tricuspid arm. Hemodynamics were similar at 30 days. CONCLUSIONS: Preliminary data from the FDA-approved IDE trials of low-risk patients with bicuspid AS undergoing TAVR demonstrated 30-day outcomes comparable to low-risk tricuspid patients, except for a trend toward higher stroke in bicuspid patients. Randomized trials are warranted to reassure the safety and long-term outcome of TAVR in patients with severe bicuspid AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Teorema de Bayes , Humanos , Estudos Prospectivos , Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Cardiovasc Revasc Med ; 33: 7-12, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34078581

RESUMO

BACKGROUND: Prospective bicuspid low-risk transcatheter aortic valve replacement (TAVR) registries' data demonstrated encouraging short-term results. Detailed data on transcatheter heart valve (THV) geometry after deployment using contemporary devices are lacking. This study sought to examine valve geometry after TAVR in patients with bicuspid aortic stenosis (AS). METHODS: The study population was patients from the LRT (Low Risk TAVR) trial who underwent TAVR using the SAPIEN 3 THV for bicuspid and tricuspid AS. THV geometry measured on 30-day computed tomography (CT) included valve height, angle, depth, and eccentricity. Additionally, THV hemodynamics and outcomes post-TAVR were compared among patients with bicuspid and tricuspid AS. RESULTS: A total of 107 patients from the LRT trial using the SAPIEN 3 THV were included in our analysis. On 30-day CT, the valve height ratio (1.07 vs. 1.07; p = 0.348), depths (right [5.6 mm vs. 6.2 mm; p = 0.223], left [5.3 mm vs. 4.4 mm; p = 0.082] and non [4.8 mm vs. 4.5 mm; p = 0.589] coronary cusps), eccentricities (1.08 vs. 1.07; p = 0.9550), and angles (except the right [3.9 degrees vs. 6.3 degrees; p = 0.003] and left [3.6 degrees vs. 6.0 degrees; p = 0.007]) were similar between bicuspid and tricuspid patients. Hemodynamics, stroke, and mortality were similar at 1 year. CONCLUSION: Despite challenging bicuspid anatomy of the aortic valve, our comprehensive CT analysis supports similar THV geometry between patients with bicuspid and tricuspid AS undergoing TAVR using the SAPIEN 3 THV in low-risk patients. This translated to excellent short-term clinical outcomes and THV hemodynamics in both aortic valve morphologies. TRIAL REGISTRY: NCT02628899, https://clinicaltrials.gov/ct2/show/NCT02628899.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Cardiovasc Revasc Med ; 29: 85-88, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33965334

RESUMO

BACKGROUND: Before its voluntary recall, the mechanically expandable LOTUS Edge transcatheter heart valve (THV) offered a number of unique features, notably sealing against paravalvular leak (PVL) and the ability to be fully deployed, re-captured, and re-deployed. METHODS: We performed a detailed review of all patients at our institution who underwent transcatheter aortic valve replacement (TAVR) using the LOTUS Edge THV from 2019 to 2020. We describe procedural and in-hospital outcomes. RESULTS: In brief, 59 patients underwent TAVR using the LOTUS Edge, of whom 18 were high-risk (most of whom had moderate or severe left ventricular outflow tract [LVOT] calcium), 36 were intermediate-risk enrolled in the REPRISE IV trial (one of whom had a bicuspid valve), and 5 were low-risk bicuspid patients enrolled in the LRT trial. Conduction disturbances were common (new left bundle branch block in 64.4%), with high rates of new permanent pacemaker (PPM) implantation across all risk groups (16.9%). Overall, stroke occurred in 11.9% of patients, and in 3/5 low-risk bicuspid patients, but occurred less frequently in patients with cerebral embolic protection. CONCLUSIONS: In our experience, in patients with heavy LVOT calcium burden and/or bicuspid valves, the LOTUS Edge THV offered excellent seal against PVL. However, the high rates of periprocedural stroke and new PPM implantation were a concern.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Ann Vasc Surg ; 74: 237-245, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33549798

RESUMO

BACKGROUND: Parallel grafting presents a viable method for treating patients with complex aortic aneurysms. The current literature is limited to mostly pararenal configurations. We examined our results in patients with SMA and/or Celiac artery involvement. METHODS: A retrospective analysis was performed for all patients undergoing parallel grafting during the period of 2014 to 2018 at a single institution. All patients had at least SMA with and/or without Celiac artery parallel grafting. RESULTS: Seventy-nine patients (65% male, median age 74) were treated with 208 parallel grafts. Median ASA score is 4. Forty-nine cases were elective, 22 urgent, and 8 emergent. Mean pre-operative aneurysm diameter was 7.1 cm (4.6-15 cm). Self-expanding covered stents were used for the renal arteries (mean 6.3mm), and balloon-expandable covered stents were used for the SMA and Celiac (mean SMA 8.6 mm, mean celiac 8.3 mm). Axillary exposure was the choice of access in 68 patients (86%). Technical success was achieved in all cases. We defined this as aneurysm sac exclusion with patent visceral stent grafts, and absent to mild gutter leaks. Mean aortic graft proximal seal achieved was 48mm. Coverage extended above the celiac artery in 75% (10% stented and 65% covered). Median contrast volume was 145ml, operative duration was 4 hours, fluoroscopy time was 56 min, and EBL was 250 ml. Perioperative mortality was 6.1%. 4.5%, and 25%, for the elective, urgent, and emergent groups, respectively. There was no incidence of spinal cord ischemia. Axillary access was complicated in 4 patients, requiring patch closure of the axillary artery. One patient developed postprocedural ESRD from a rupture and ATN despite patent renal stents. Of those patients with a patent GDA and celiac coverage, 2 required a cholecystectomy. Nine patients had a persistent gutter leak at the conclusion of the procedure. Median follow-up was 12 months. On follow-up imaging, all SMA and Celiac stents were patent. Six renal stents were occluded and 2 patients progressed to ESRD, both solitary renal periscope configurations at the index procedure. Only 4 patients had persistent gutter leaks with 2 requiring reintervention. Ninety-five percent of patients demonstrated sac regression or stabilization with a mean sac size of 6.5 cm. CONCLUSIONS: Parallel grafting presents a safe, efficacious and off the shelf alternative to conventional repair of complex aortic aneurysms involving the visceral aorta.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Artéria Celíaca/cirurgia , Procedimentos Endovasculares , Artéria Mesentérica Superior/cirurgia , Artéria Renal/cirurgia , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/fisiopatologia , Tomada de Decisão Clínica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/fisiopatologia , Complicações Pós-Operatórias/mortalidade , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Circulação Renal , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Circulação Esplâncnica , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
20.
Heart Rhythm ; 18(2): 303-312, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33045430

RESUMO

The absence of strategies to consistently and effectively address nonparoxysmal atrial fibrillation by nonpharmacological interventions has represented a long-standing treatment gap. A combined epicardial/endocardial ablation strategy, the hybrid Convergent procedure, was developed in response to this clinical need. A subxiphoid incision is used to access the pericardial space facilitating an epicardial ablation directed at isolation of the posterior wall of the left atrium. This is followed by an endocardial ablation to complete isolation of the pulmonary veins and for additional ablation as needed. Experience gained with the hybrid Convergent procedure during the last decade has led to the development and adoption of strategies to optimize the technique and mitigate risks. Additionally, a surgical and electrophysiology "team" approach including comprehensive training is believed critical to successfully develop the hybrid Convergent program. A recently completed randomized clinical trial indicated that this ablation strategy is superior to an endocardial-only approach for patients with persistent atrial fibrillation. In this review, we propose and describe best practice guidelines for hybrid Convergent ablation on the basis of a combination of published data, author consensus, and expert opinion. A summary of clinical outcomes, emerging evidence, and future perspectives is also given.


Assuntos
Fibrilação Atrial/cirurgia , Endocárdio/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Pericárdio/cirurgia , Guias de Prática Clínica como Assunto , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Humanos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...