Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Clin Exp Dent Res ; 10(2): e857, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433306

RESUMO

OBJECTIVES: Limited studies are available on the accuracy of intraoral scanners (IOSs) for full-arch implant and tooth models. This study aimed to assess the accuracy of maxillary full-arch digital impressions of tooth and implant models made by two IOSs. MATERIALS AND METHODS: This in vitro, experimental study was conducted on two maxillary dentiform models: one with six prepared natural teeth and the other with six implants at the site of canine, first premolar, and first molar teeth, bilaterally. A highly accurate industrial scanner was used for actual measurements on the models that served as the reference scan. TS (Trios3) and CO (CEREC Omnicam) IOSs were then used to scan each model 10 times according to the manufacturer's instructions. All scans were saved in STL format. The GOM Inspect software was used according to the best-fit algorithm to compare the accuracy of measurements in the groups with the reference scan. The trueness and precision were calculated. Statistical analyses were carried out using SPSS by one-way analysis of variance and t-test (α = .05). RESULTS: TS showed a significantly higher trueness than CO for both tooth and implant models (p < .05). TS also revealed significantly higher precision than CO for the tooth model; however, the difference in precision for the implant model was not significant between the two IOSs (p > .05). CONCLUSIONS: TS showed higher accuracy than CO in both tooth and implant models.


Assuntos
Implantes Dentários , Dente Molar , Modelos Dentários , Projetos de Pesquisa , Software
2.
Eur J Dent Educ ; 27(1): 167-173, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35233898

RESUMO

INTRODUCTION: The COVID-19 pandemic has a great impact on all aspects of higher education worldwide. In Iran, after several months of lockdown, all dental schools coped with the challenge of "reopening." School of Dentistry of Tehran University of Medical Sciences (TUMS) planned to facilitate the process of reopening using a "step-by-step" approach. The aim of this study was sharing our experiences of reopening of the school during the pandemic. METHODS: TUMS School of Dentistry planned a "step-by-step" approach of reopening of school to both provide infrastructure of online education for theoretical credits and reassure all staff and students about infection control for practical courses. Also, a two-section survey on students' satisfaction with a variety of aspects of reopening process and the clinical performance of students in different clinical courses was conducted. RESULTS: Findings showed 65.1% of the students, attended the survey, were satisfied with reopening of the school. Also, 86.4% were satisfied with the new online method of education for theoretical courses. Regarding personal protective equipment (PPE) provided for the students, 22.9% and 56.5% of them were satisfied and moderately satisfied, respectively. Additionally, 78.2% of the students were satisfied with the newly developed online assessment method. CONCLUSION: Although reopening of schools during COVID-19 pandemic seems enigmatic for all authorities and students, the "step-by-step" plan designed by TUMS School of dentistry including emotional and infrastructural prerequisites might be a reliable method for all people, who are in charge of management of dental school in uncertain crisis.


Assuntos
COVID-19 , Faculdades de Odontologia , Humanos , Odontologia , Educação em Odontologia , Irã (Geográfico) , Pandemias
3.
Artigo em Inglês | MEDLINE | ID: mdl-36141729

RESUMO

This study assessed the clinical variables influencing the success of three-unit implant-supported fixed dental prostheses (ISFDPs) fabricated using either fully digital or conventional workflows. The clinical trial evaluated 10 patients requiring three-unit ISFDPs in the posterior mandible. Maxillomandibular relation records, and digital and conventional impressions were obtained from each patient using an intraoral scanner (IoS) and polyvinylsiloxane (PVS), and the frameworks were fabricated using zirconia and cobalt-chromium, respectively. A 2 µm accuracy scanner scanned the conventional master casts and standard reference models. The stereolithography (STL) files of the digital and conventional impressions were superimposed on the standard model file, and the accuracy was calculated with the best-fit algorithm. The framework adaptation and passivity were assessed using the one-screw and screw resistance tests. The time required for occlusal adjustment of both types of reconstructions, including the duration of the whole treatment, was recorded. The aesthetic appearance of ISFDPs was rated by each patient and clinician using a self-administered visual analogue scale questionnaire and the FDI World Dental Federation aesthetic parameters, respectively. The sample size was based on the power calculation, and alpha was set at 0.05 for the statistical analyses. The impression accuracy, framework adaptation and passivity, and reconstructions aesthetics did not significantly differ between the digital and conventional approaches. The total fabrication time was significantly shorter using the digital workflow. Within the limitations of this clinical study, the fully digital workflow can be used for the fabrication of ISFDPs with a clinical outcome comparable to that of the conventional workflow.


Assuntos
Cobalto , Desenho Assistido por Computador , Cromo , Estudos Cross-Over , Humanos , Estudos Prospectivos , Fluxo de Trabalho
4.
J Prosthet Dent ; 127(4): 600.e1-600.e8, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35016795

RESUMO

STATEMENT OF PROBLEM: The influence of different restorative materials, the divergence angle, and the preparation design of the pulp chamber floor in endocrowns on stress distribution is unclear. PURPOSE: The purpose of this finite element analysis study was to evaluate the stress distribution and maximum von Mises stress values in endocrown restorations and remaining teeth. MATERIAL AND METHODS: An endodontically treated first mandibular molar was prepared with 2-mm occlusal reduction, a butt-joint margin, and a mesial box with a 4-mm buccolingual extension to receive an endocrown restoration. The model was then scanned, and the exported standard tessellation language file was designed according to the anatomic references by using a computer-aided design software program. The reference model was duplicated, and 27 variations were formed: restorations made of IPS e.max, Vitablocs MarkII, and Vita Enamic, as well as different divergence angles of 6, 12, and 16 degrees prepared with 3 variations of pulp chamber floor designs, keeping the natural form, adding a 1-mm glass ionomer pulp chamber base, and adding a 2-mm extension into the distal canal. Stress distribution under axial loading and maximum von Mises stress values were analyzed and calculated by using the Ansys software program. RESULTS: The endocrown restoration presented the lowest von Mises stress values when a 6-degree divergence angle was used with Vitablocs MarkII. However, in other layers such as enamel, resin cement, and pulpal floor, the lowest von Mises stress values were observed in IPS e.max restorative material when the divergence angle was increased to 16 degrees. No difference was found in the stress distribution pattern and maximum von Mises stress values in the alveolar bone or periodontal ligament. CONCLUSIONS: Endocrowns fabricated with lithium disilicate ceramics without intraradicular extension exhibited lower stresses on tooth structure. An increase in the divergence angle improved the stress distribution on tooth structure; however, sound dental tissue should not be removed to achieve better stress distribution.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Materiais Dentários/química , Porcelana Dentária/química , Análise do Estresse Dentário , Análise de Elementos Finitos , Teste de Materiais , Cimentos de Resina
5.
Front Dent ; 19: 33, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36873611

RESUMO

Objective: Dental educational curricula are under constant modification and improvement. However, designing a comprehensive, efficient, and flexible curriculum is still challenging for the authorities. An efficient curriculum should obviate the educational needs of students and promote their knowledge and expertise for future practice. Time planning of clinical rotations is highly important for optimization of the learning process. This study aimed to compare the efficacy of two different timing models of clinical rotations, namely four versus two rotations in each semester. Materials and Methods: A total of 74 dental students and 54 faculty members of Tehran University of Medical Science that experienced both rotation models for two consecutive years (2018 and 2019) participated in this study. A questionnaire was designed to assess different aspects of the two timing-models. Results: A one-sample t-test indicated that students' and faculty members' mean perception were significantly better regarding the two-rotation program. Conclusion: This study indicated that changing the time planning of educational rotations can affect different aspects of education.

6.
J Esthet Restor Dent ; 32(2): 236-243, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31565836

RESUMO

OBJECTIVE: This study compared digital and conventional impression techniques regarding impression time, frequency of adjustments, and adaptation of cobalt-chromium (Co-Cr) copings with supragingival and subgingival finish lines. MATERIALS AND METHODS: Thirty premolars prepared for single-unit metal-ceramic restorations with supragingival and subgingival finish lines (n = 15). Conventional impression and digital scan of prepared teeth were made. Using computer aided design/computer aided manufacturing (CAD/CAM) system the copings were produced by a milling machine from Co-Cr blocks and internal and marginal discrepancies were measured using silicone replica technique. Data were analyzed using repeated measures ANOVA and Mann-Whitney test (alpha = .05). RESULTS: The impression technique had a significant effect on the magnitude of gap (P < .001). The internal and marginal gaps in the digital technique (49.43 µ and 60.07 µ, respectively) were significantly lower than the values in the conventional method (91.88 µ and 96.96 µ, respectively-P < .001). Finish line positions had no significant effect on the fit and marginal gap of copings (P = .54 and .243, respectively). The mean impression time (19':27″ in conventional technique and 10':31″ in digital technique) was significantly shorter (P < .001) and the mean frequency of adjustments (2.2 times for conventional and 1.3 times for digital technique) was significantly lower in the digital technique (P < .001). The gingival biotype (thick or thin) had no significant effect on marginal and internal fit (P = .052 and .319, respectively). CONCLUSION: The digital technique was superior in terms of fit, impression time, and frequency of adjustments. Finish line positions had no significant effect on the fit of copings. CLINICAL SIGNIFICANCE: Using intraoral scanner promotes the fits of restorations in supragingival and subgingival finish lines.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Coroas , Técnica de Moldagem Odontológica
7.
Front Dent ; 16(3): 194-205, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31858085

RESUMO

OBJECTIVES: Internal fit of implant frameworks is an important factor determining the long-term success of dental implant restorations. This in-vitro study aimed to evaluate dimensional changes of implant-supported zirconia frameworks fabricated by two computer-aided design/computer-aided manufacturing (CAD/CAM) systems from scanning to sintering. MATERIALS AND METHODS: A master model of a three-unit fixed partial denture was fabricated with two implant abutments. In each CAD/CAM system (AmannGirrbach and Zirkonzahn), the master model was scanned 12 times, and data were saved as Standard Transformation Language files (scanning groups). Using semi-sintered zirconia, 12 real-size frameworks (milling groups) and 12 enlarged frameworks, were sintered (sintering groups) and made by each system. Dimensions of the master model and frameworks in each phase were measured. Dimensional changes (compared to the master model) were calculated. Data were analyzed using repeated measures analysis of variance, independent t-test, and paired sample t-test (α=0.05). RESULTS: Comparison of the two systems revealed that although dimensional changes were greater in the milling phase of Zirkonzahn, they were larger in the sintering phase of the AmannGirrbach system. Evaluation of fabrication phases revealed greater dimensional changes in the milling phase compared to the other phases in the Zirkonzahn system (P<0.05). However, in the AmannGirrbach system, the values were not significantly different between milling and sintering phases (P>0.05). CONCLUSION: Within the limitations of this study, the results showed that fabrication phases, CAD/CAM system type and abutment size had significant effects on dimensional changes.

8.
Front Dent ; 16(2): 153-157, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31777858

RESUMO

Dental implants are highly recommended to improve the retention, stability, and support of prostheses in edentulous patients with large surgical defects. Depending on the size of the defect, a bone graft procedure might be necessary. However, due to limitations of bone grafts, some complications might negatively affect the prosthetic rehabilitation of the patient. This case report presents some of these prosthetic problems following surgical resection and autogenous bone graft procedures.

9.
J Prosthet Dent ; 121(2): 364.e1-364.e6, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30598306

RESUMO

STATEMENT OF PROBLEM: Conventional cast metal posts and cores are fabricated using direct and indirect techniques, both of which need impression materials and considerable laboratory work. Digital techniques have the capacity to substitute for conventional methods in fabricating the posts and cores. However, the accuracy of restorations resulting from a digital workflow is unknown. PURPOSE: The purpose of this in vitro study was to compare the retention of posts and cores fabricated using full-digital, half-digital, and conventional techniques and to define the accuracy of each technique in terms of the apical gap. METHOD AND MATERIALS: Thirty newly extracted mandibular first and second premolar teeth were selected for this in vitro study. Impressions were made using direct acrylic resin patterns (conventional), indirect silicone impressions of the intracanal which scanned with a 3Shape laboratory scanner (half digital), and intracanal scan posts captured with an intraoral 3Shape scanner (full digital). Casting and milling were conducted for the conventional impression and digital scans. The obtained posts were cemented using zinc phosphate cement. A universal pullout test was used to measure retention at a crosshead speed of 0.5 mm/min. The apical gap of each post in the canals was defined with parallel digital radiography. The data were analyzed using the Kruskal-Wallis test (α=.05) and Mann-Whitney test at the adjusted α=.016. RESULTS: Significant differences were found among the conventional, full-digital, and half-digital techniques in terms of the apical gap (0.11, 0.29, and 0.66 mm; P<.001) and retention (171.6 ±1.9, 107.1 ±5.6 and 91.8 ±6.6 N; P<.001). The correlation between gap and retention in conventional (P=.43), full-digital (P=.09), and half-digital techniques (P=.06) was not statistically significantly different. CONCLUSIONS: The conventional technique was more accurate and resulted in higher retention than both the full- and half-digital techniques. However, the retention and gap of all the posts fell within clinical guidelines.


Assuntos
Planejamento de Prótese Dentária/métodos , Técnica para Retentor Intrarradicular , Dente Pré-Molar , Desenho Assistido por Computador , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Radiografia Dentária Digital , Silicones , Cimento de Fosfato de Zinco/química
10.
J Prosthodont ; 28(2): e661-e665, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29239053

RESUMO

PURPOSE: Improper seating of abutment on the implant is a common problem. This study investigated the effect of the type of implant/abutment interface on the complete seating of the abutments on the head of implants placed at different gingival depths. MATERIALS AND METHODS: Three implant systems with three different connections including straight external hexagon, butt-joint internal tri-lobed, and conical internal hexagon were used. Two gingival thicknesses (2 and 7 mm) were created using pink baseplate wax around the straight abutments seated on the implants. After placing the implants in acrylic blocks, the wax was replaced with the gingival mask material to simulate the gingival drape around the implant heads. Afterwards, 15 prosthodontists were asked to hand-tighten the straight abutments in the corresponding implant bodies relying only on their tactile sense. At the final stage, the gingival mask was removed, and the seating quality of the abutments on implant bodies was assessed visually. The effect of implant connection and depth on abutment seating accuracy was analyzed using Kruskal-Wallis and multiple-comparison tests. RESULTS: No significant difference was found regarding the effect of either depth or connection design on the accuracy of the abutment seating (p > 0.05); however, pairwise comparison of the combined effect of the depth and connection design was significant (p = 0.009). Accuracy of abutment seating on the Nobel Active implants at both 2 and 7 mm depths were significantly better than Replace system with 7 mm depth (p = 0.027). The same results were obtained in comparison between Nobel Active system at both 2 and 7 mm depths with Branemark system with 7 mm depth (p = 0.006). CONCLUSION: An increase in implant placement depth meant a decrease in accuracy of the abutment seating. The internal conical connection design showed the best result in abutment positioning in deep implants as compared with external and internal butt-joint connection designs.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Prótese Dentária Fixada por Implante , Resinas Acrílicas , Prótese Dentária Fixada por Implante/instrumentação , Prótese Dentária Fixada por Implante/métodos , Humanos
11.
J Dent (Tehran) ; 15(4): 259-265, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30405735

RESUMO

Typically, full arch reconstruction of edentulous ridges requires five to 10 dental implants; however, some patients demanding fixed implant-supported prostheses are not able to medically or economically afford complex bone grafts and/or a greater number of implants. These situations could pivot the treatment plan toward the All-on-4 protocol. Nevertheless, due to less implant support in this treatment option, mechanical and biological complications might arise. This article describes the treatment of a fully edentulous patient with two types of fixed implant-supported prostheses on four dental implants along with the following complications.

12.
Artigo em Inglês | MEDLINE | ID: mdl-30443303

RESUMO

Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups.

13.
J Clin Exp Dent ; 10(2): e151-e157, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29670733

RESUMO

BACKGROUND: Precision of implant impressions is a prerequisite for long-term success of implant supported prostheses. Impression materials and impression techniques are two important factors that impression precision relies on. MATERIAL AND METHODS: A model of edentulous maxilla containing four implants inserted by All-on-4 guide was constructed. Seventy two impressions using polyether (PE), polyvinyl siloxane (PVS), and vinyl siloxanether (VSE) materials with direct and indirect techniques were made (n=12). Coordinates of implants in casts were measured using coordinate measuring machine (CMM). Data were analyzed with ANOVA; t-test and Tukey test were used for post hoc. RESULTS: With two-way ANOVA, mean values of linear displacements of implants were significantly different among materials and techniques. One-way ANOVA and Tukey showed significant difference between PE and VSE (P=0.019), PE and PVS (P=0.002) in direct technique, and between PVS and PE (P<0.001), PVS and VSE (P<0.001) in indirect technique. One-way ANOVA and t-test showed significant difference between the two techniques in PVS groups (P<0.001) and in PE groups (P=0.02). Two-way ANOVA showed mean values of rotational displacement of implants were significantly different among materials. One-way ANOVA and Tukey test showed significant difference between PVS and PE (P=0.001) and between PVS and VSE (P=0.012) in indirect groups. CONCLUSIONS: On the basis of the results, when deciding on the material to make an impression of implants, PE is recommended for direct technique while PE and VSE are recommended for indirect technique. Recommended technique for VSE is either direct or indirect; and for PE and PVS is direct. Key words:Polyvinyl siloxane, polyether, vinyl siloxanether, direct technique, indirect technique, All-on-4, coordinate measuring machine.

14.
J Clin Exp Dent ; 10(11): e1096-e1102, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30607227

RESUMO

BACKGROUND: Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions using full-arch versus sectional tray and Vinyl Polysiloxane versus Vinyl Polyether Siloxane in angulated implants. MATERIAL AND METHODS: Four implants were placed in dental areas #19, #21, #28 and #30 of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty sectional and 20 full-arch open trays were made on the primary cast. Impressions were taken using Vinyl Polysiloxane and Vinyl Polyether Siloxane (n=10 in 4 groups); and were poured with type IV dental stone. The coordinate measuring machine was used to measure displacements in the X, Y and Z axes and rotational discrepancies of implants. The data were analyzed using SPSS 22 and two-way ANOVA. RESULTS: Type of tray had no significant effect on the dimensional and angular accuracy of impressions (p >0.05). Type of impression material significantly affected linear displacement (∆r) (P <0.05); but it did not significantly affect the rotational displacement (P >0.05). CONCLUSIONS: Vinyl Polysiloxane yielded more accurate impressions of angulated implants. Key words:Dental implant, impression material, impression tray, vinyl polysiloxane, vinyl polyether silicone, coordinate measuring machine.

15.
J Adv Prosthodont ; 9(4): 271-277, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28874994

RESUMO

PURPOSE: This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS: Two regular platform dental implants, one with external connection (Brånemark, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at α=0.05 of significance. RESULTS: There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION: Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

16.
J Prosthodont ; 26(4): 331-338, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26805651

RESUMO

Dental implants have become a popular treatment modality for replacing missing teeth. In this regard, the importance of restoring patients with function during the implant healing period has grown in recent decades. Esthetic concerns, especially in the anterior region of the maxilla, should also be considered until the definitive restoration is delivered. Another indication for such restorations is maintenance of the space required for esthetic and functional definitive restorations in cases where the implant site is surrounded by natural teeth. Numerous articles have described different types of interim prostheses and their fabrication techniques. This article aims to briefly discuss all types of implant-related interim prostheses by different classification including provisional timing (before implant placement, after implant placement in unloading and loading periods), materials, and techniques used for making the restorations, the type of interim prosthesis retention, and definitive restoration. Furthermore, the abutment torque for such restorations and methods for transferring the soft tissue from interim to definitive prostheses are addressed.


Assuntos
Restauração Dentária Temporária/métodos , Prótese Parcial Removível , Prótese Parcial Temporária , Dente Suporte , Implantes Dentários , Estética Dentária , Humanos
17.
Int J Prosthodont ; 29(3): 265-70, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27148987

RESUMO

PURPOSE: The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol. MATERIALS AND METHODS: An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with different techniques (open and closed tray) at abutment and implant levels and poured in type IV dental stone. A coordinate measuring machine was used to record the x, y, and z coordinates and angular displacement. The measurements were compared with those obtained from the reference model. Data were analyzed with analysis of variance and t test at α = .05. RESULTS: There was less linear and rotational displacement for the open-tray technique when compared with the closed-tray technique (P = .02 and P < .001, respectively). Impressions made at abutment level produced fewer linear and rotational displacements when compared with implant level impressions using the open-tray technique for straight and angulated implants (P = .04 and P < .001, respectively). However, less rotational dislocation was observed for impressions made with the closed-tray technique when compared with the open-tray technique at implant level (P < .001). CONCLUSION: Choice of impression technique affected the accuracy of impressions, and less displacement was observed with the open-tray method. Abutment-level impressions with an open-tray technique were more accurate, while implant-level impressions were more accurate when a closed-tray technique was used.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica/normas , Dente Suporte , Técnica de Moldagem Odontológica/instrumentação , Humanos , Arcada Edêntula/patologia , Teste de Materiais , Maxila/patologia , Modelos Anatômicos , Rotação , Propriedades de Superfície
18.
J Dent (Tehran) ; 13(3): 176-183, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28392814

RESUMO

OBJECTIVES: Microbial leakage through the implant-abutment (I-A) interface results in bacterial colonization in two-piece implants. The aim of this study was to compare microleakage rates in three types of Replace abutments namely Snappy, GoldAdapt, and customized ceramic using radiotracing. MATERIALS AND METHODS: Three groups, one for each abutment type, of five implants and one positive and one negative control were considered (a total of 17 regular body implants). A torque of 35 N/cm was applied to the abutments. The samples were immersed in thallium 201 radioisotope solution for 24 hours to let the radiotracers leak through the I-A interface. Then, gamma photons received from the radiotracers were counted using a gamma counter device. In the next phase, cyclic fatigue loading process was applied followed by the same steps of immersion in the radioactive solution and photon counting. RESULTS: Rate of microleakage significantly increased (P≤0.05) in all three types of abutments (i.e. Snappy, GoldAdapt, and ceramic) after cyclic loading. No statistically significant differences were observed between abutment types after cyclic loading. CONCLUSIONS: Microleakage significantly increases after cyclic loading in all three Replace abutments (GoldAdapt, Snappy, ceramic). Lowest microleakage before and after cyclic loading was observed in GoldAdapt followed by Snappy and ceramic.

19.
Eur J Prosthodont Restor Dent ; 24(4): 186-191, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28510372

RESUMO

PURPOSE: This study investigated the influence of placing implant-supported crowns on the torque loss of the abutment screw before and after loading. MATERIAL AND METHODS: Twenty implant-abutment assemblies were randomly assigned to two groups. The first group was consisted of abutments with abutment-level finishing line (abutment-level), and in the second group the crown margin was placed on the implant shoulder (implant-level). Initial torque loss was recorded for all specimens. After 500000 cyclic load of 75 N and frequency of 2 Hz, post loading torque loss was recorded. Finite element model of each group was also modeled and screw energy, and stress were analyzed and compared between two groups. RESULTS: ANOVA for repeated measurements showed that the torque loss did not change significantly after cyclic loading (P=0.73). Crown margin also had no significant effect on the torque loss (P=0.56). However, the energy and stress of screw in abutment-level model (4.49 mJ and 22.74 MPa) was higher than implant-level model (3.52 mJ and 20.81 MPa). CONCLUSIONS: Although embracing the implant with crown produced less stress and energy in the abutment-implant screw, it did not have any significant influence on the torque loss of the screw.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Retenção em Prótese Dentária , Análise do Estresse Dentário , Distribuição Aleatória , Torque
20.
J Dent (Tehran) ; 13(6): 415-422, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28243303

RESUMO

OBJECTIVES: The purpose of this study was to compare the outcomes of immediate and delayed rehabilitation of edentulous jaws by means of two straight and two tilted implants after one year of function. MATERIALS AND METHODS: Thirty consecutive patients (16 males, 14 females) were enrolled in this study. Two anterior straight and two posterior tilted implants were placed in each patient. According to the implant insertion torque and the need for bone grafting, implants were loaded immediately (at 72 hours) or delayed (after four months) using a fixed metal resin prosthesis. RESULTS: One axial implant failed in the delayed group after one year of loading, resulting in cumulative implant survival rate of 99.3%. The mean marginal bone loss was 0.84mm. No significant difference was found between axial and tilted implants in the two groups (P>0.05). CONCLUSIONS: Based on the results, immediate or delayed fabrication of final prosthesis on two tilted and two axial implants did not result in significant differences in survival rates or marginal bone loss.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...