Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 9(2): 101379, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38405312

RESUMO

Purpose: The PERYTON trial is a multicenter randomized controlled trial that will investigate whether the treatment outcome of salvage external beam radiation therapy (sEBRT) will be improved with hypofractionated radiation therapy. A pretrial quality assurance (QA) program was undertaken to ensure protocol compliance within the PERYTON trial and to assess variation in sEBRT treatment protocols between the participating centers. Methods and Materials: Completion of the QA program was mandatory for each participating center (N = 8) to start patient inclusion. The pretrial QA program included (1) a questionnaire on the center-specific sEBRT protocol, (2) a delineation exercise of the clinical target volume (CTV) and organs at risk, and (3) a treatment planning exercise. All contours were analyzed using the pairwise dice similarity coefficient (DSC) and the 50th and 95th percentile Hausdorff distance (HD50 and HD95, respectively). The submitted treatment plans were reviewed for protocol compliance. Results: The results of the questionnaire showed that high-quality, state-of-the-art radiation therapy techniques were used in the participating centers and identified variations of the sEBRT protocols used concerning the position verification and preparation techniques. The submitted CTVs showed significant variation, with a range in volume of 29 cm3 to 167 cm3, a mean pairwise DSC of 0.52, and a mean HD50 and HD95 of 2.3 mm and 24.4 mm, respectively. Only in 1 center the treatment plan required adaptation before meeting all constraints of the PERYTON protocol. Conclusions: The pretrial QA of the PERYTON trial demonstrated that high-quality, but variable, radiation techniques were used in the 8 participating centers. The treatment planning exercise confirmed that the dose constraints of the PERYTON protocol were feasible for all participating centers. The observed variation in CTV delineation led to agreement on a new (image-based) delineation guideline to be used by all participating centers within the PERYTON trial.

2.
Phys Imaging Radiat Oncol ; 28: 100489, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37822533

RESUMO

Background and Purpose: Diffusion weighted magnetic resonance imaging (DW-MRI) can be prognostic for response to neoadjuvant chemotherapy (nCRT) in patients with esophageal cancer. However, manual tumor delineation is labor intensive and subjective. Furthermore, noise in DW-MRI images will propagate into the corresponding apparent diffusion coefficient (ADC) signal. In this study a workflow is investigated that combines a denoising algorithm with semi-automatic segmentation for quantifying ADC changes. Materials and Methods: Twenty patients with esophageal cancer who underwent nCRT before esophagectomy were included. One baseline and five weekly DW-MRI scans were acquired for every patient during nCRT. A self-supervised learning denoising algorithm, Patch2Self, was used to denoise the DWI-MRI images. A semi-automatic delineation workflow (SADW) was next developed and compared with a manually adjusted workflow (MAW). The agreement between workflows was determined using the Dice coefficients and Brand Altman plots. The prognostic value of ADCmean increases (%/week) for pathologic complete response (pCR) was assessed using c-statistics. Results: The median Dice coefficient between the SADW and MAW was 0.64 (interquartile range 0.20). For the MAW, the c-statistic for predicting pCR was 0.80 (95% confidence interval (CI):0.56-1.00). The SADW showed a c-statistic of 0.84 (95%CI:0.63-1.00) after denoising. No statistically significant differences in c-statistics were observed between the workflows or after applying denoising. Conclusions: The SADW resulted in non-inferior prognostic value for pCR compared to the more laborious MAW, allowing broad scale applications. The effect of denoising on the prognostic value for pCR needs to be investigated in larger cohorts.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...