Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Expert Opin Drug Deliv ; 20(8): 1055-1070, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37385962

RESUMO

INTRODUCTION: Soft mist inhalers (SMIs) are propellant-free inhalers that utilize mechanical power to deliver single or multiple doses of inhalable drug aerosols in the form of a slow mist to patients. Compared to traditional inhalers, SMIs allow for a longer and slower release of aerosol with a smaller ballistic effect, leading to a limited loss in the oropharyngeal area, whilst requiring little coordination of actuation and inhalation by patients. Currently, the Respimat® is the only commercially available SMI, with several others in different stages of preclinical and clinical development. AREAS COVERED: The primary purpose of this review is to critically assess recent advances in SMIs for the delivery of inhaled therapeutics. EXPERT OPINION: Advanced particle formulations, such as nanoparticles which target specific areas of the lung, Biologics, such as vaccines, proteins, and antibodies (which are sensitive to aerosolization), are expected to be generally delivered by SMIs. Furthermore, repurposed drugs are expected to constitute a large share of future formulations to be delivered by SMIs. SMIs can also be employed for the delivery of formulations that target systemic diseases. Finally, digitalizing SMIs would improve patient adherence and provide clinicians with fundamental insights into patients' treatment progress.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Inaladores Dosimetrados , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Desenho de Equipamento , Aerossóis e Gotículas Respiratórios , Nebulizadores e Vaporizadores , Administração por Inalação
2.
Pharmaceutics ; 12(7)2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32659899

RESUMO

In recent years there has been increasing interest in the pulmonary delivery of high dose dry powder drugs, such as antibiotics. Drugs in this class need to be dosed in doses far over 2.5 mg, and the use of excipients should therefore be minimized. To our knowledge, the effect of the automatic filling of high dose drug formulations on the maximum dose that can be filled in powder inhalers, and on the dispersion behavior of the powder, have not been described so far. In this study, we aimed to investigate these effects after filling with an Omnidose, a vacuum drum filler. Furthermore, the precision and accuracy of the filling process were investigated. Two formulations were used-an isoniazid formulation we reported previously and an amikacin formulation. Both formulations could be precisely and accurately dosed in a vacuum pressure range of 200 to 600 mbar. No change in dispersion was seen after automatic filling. Retention was decreased, with an optimum vacuum pressure range found from 400 to 600 mbar. The nominal dose for amikacin was 57 mg, which resulted in a fine particle dose of 47.26 ± 1.72 mg. The nominal dose for isoniazid could be increased to 150 mg, resulting in a fine particle dose of 107.35 ± 13.52 mg. These findings may contribute to the understanding of the upscaling of high dose dry powder inhalation products.

3.
Pharmaceutics ; 12(1)2019 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-31881695

RESUMO

Tuberculosis is the leading cause of death from a single infectious pathogen worldwide. Lately, the targeted delivery of antibiotics to the lungs via inhalation has received increasing interest. In a previous article, we reported on the development of a spray-dried dry powder isoniazid formulation containing an L-leucine coating. It dispersed well but had poor physical stability. In this study, we aimed to improve the stability by improving the leucine coating. To this end, we optimized the spray-drying conditions, the excipient content, and the excipient itself. Using L-leucine, the tested excipient contents (up to 5%) did not result in a stable powder. Contrary to L-leucine, the stability attained with trileucine was satisfactory. Even when exposed to 75% relative humidity, the formulation was stable for at least three months. The optimal formulation contained 3% trileucine w/w. This formulation resulted in a maximum fine particle dose of 58.00 ± 2.56 mg when a nominal dose of 80 mg was dispersed from the Cyclops® dry powder inhaler. The improved moisture protection and dispersibility obtained with trileucine are explained by its amorphous nature and a higher surface enrichment during drying. Dispersion efficiency of the device decreases at higher nominal doses.

4.
Pharmaceutics ; 11(5)2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086107

RESUMO

Tuberculosis is a major health problem and remains one of the main causes of mortality. In recent years, there has been an increased interest in the pulmonary delivery of antibiotics to treat tuberculosis. Isoniazid is one of these antibiotics. In this study, we aimed to characterize isoniazid and formulate it into a dry powder for pulmonary administration with little or no excipient, and for use in the disposable Twincer® inhaler. Isoniazid was jet milled and spray dried with and without the excipient l-leucine. Physiochemical characterization showed that isoniazid has a low Tg of -3.99 ± 0.18 °C and starts to sublimate around 80 °C. Milling isoniazid with and without excipients did not result in a suitable formulation, as it resulted in a low and highly variable fine particle fraction. Spray drying pure isoniazid resulted in particles too large for pulmonary administration. The addition of 5% l-leucine resulted in a fraction <5 µm = 89.61% ± 1.77% from spray drying, which dispersed well from the Twincer®. However, storage stability was poor at higher relative humidity, which likely results from dissolution-crystallization. Therefore, follow up research is needed to further optimize this spray dried formulation.

5.
Int J Pharm ; 548(1): 325-336, 2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-29991452

RESUMO

In recent years there is an increasing interest in the pulmonary delivery of large cohesive powder doses, i.e. drugs with a low potency such as antibiotics or drugs with a high potency that need a substantial fraction of excipient(s) such as vaccines stabilized in sugar glasses. The pulmonary delivery of high powder doses comes with unique challenges. For low potency drugs, the use of excipients should be minimized to limit the powder mass to be inhaled as much as possible. To achieve this objective the inhaler design should be adapted to the properties of the API in order to achieve a compatible combination of the drug formulation and inhaler device. The inhaler should have an appropriate powder dosing principle for which prefilled compartments seem most appropriate. The drug formulation should not only allow for accurate filling of these compartments but also enable efficient compartment emptying during inhalation. The dispersion principle must have the capacity to disperse considerable amounts of powder in a short time frame that allows the powder to reach the deep lung. Last, but not least, the inhaler should be simple and intuitive in use, be cost-effective and exhibit accurate and consistent, preferably patient independent, pulmonary delivery performance.


Assuntos
Inaladores de Pó Seco , Pós/administração & dosagem , Administração por Inalação , Animais , Excipientes/administração & dosagem , Humanos , Preparações Farmacêuticas/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...