Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 7: 44028, 2017 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-28276454

RESUMO

Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 µg kg-1 and 8 µg kg-1, respectively.


Assuntos
Aflatoxina B1/análise , Arachis/química , Análise de Alimentos , Lasers , Análise de Alimentos/instrumentação , Análise de Alimentos/métodos , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-27684544

RESUMO

The rapid identification of mycotoxins such as deoxynivalenol and aflatoxin B1 in agricultural commodities is an ongoing concern for food importers and processors. While sophisticated chromatography-based methods are well established for regulatory testing by food safety authorities, few techniques exist to provide a rapid assessment for traders. This study advances the development of a mid-infrared spectroscopic method, recording spectra with little sample preparation. Spectral data were classified using a bootstrap-aggregated (bagged) decision tree method, evaluating the protein and carbohydrate absorption regions of the spectrum. The method was able to classify 79% of 110 maize samples at the European Union regulatory limit for deoxynivalenol of 1750 µg kg-1 and, for the first time, 77% of 92 peanut samples at 8 µg kg-1 of aflatoxin B1. A subset model revealed a dependency on variety and type of fungal infection. The employed CRC and SBL maize varieties could be pooled in the model with a reduction of classification accuracy from 90% to 79%. Samples infected with Fusarium verticillioides were removed, leaving samples infected with F. graminearum and F. culmorum in the dataset improving classification accuracy from 73% to 79%. A 500 µg kg-1 classification threshold for deoxynivalenol in maize performed even better with 85% accuracy. This is assumed to be due to a larger number of samples around the threshold increasing representativity. Comparison with established principal component analysis classification, which consistently showed overlapping clusters, confirmed the superior performance of bagged decision tree classification.


Assuntos
Arachis/química , Contaminação de Alimentos/análise , Micotoxinas/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Zea mays/química , Cromatografia Líquida , Espectrometria de Massas em Tandem
3.
Anal Chem ; 88(11): 5562-73, 2016 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-27081763

RESUMO

This Feature highlights recent advances on mid-infrared thin-film waveguide technology and on-chip photonics facilitating next-generation label-free chem/bio sensor and assay platforms. Complemented by more recent advancements toward on-chip semiconductor waveguides, it is anticipated that label-free integrated mid-infrared sensing schemes will readily complement existing chem/bio sensor technologies in applications ranging from process monitoring and environmental analysis to biomedical diagnostics and point-of-care devices.

4.
Anal Chem ; 88(5): 2558-62, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26845392

RESUMO

The performance and versatility of GaAs/AlGaAs thin-film waveguide technology in combination with quantum cascade lasers for mid-infrared spectroscopy in comparison to conventional FTIR spectroscopy is presented. Infrared radiation is provided by a quantum cascade laser (QCL) spectrometer comprising four tunable QCLs providing a wavelength range of 5-11 µm (1925-885 cm(-1)) within a single collimated beam. Epitaxially grown GaAs slab waveguides serve as optical transducer for tailored evanescent field absorption analysis. A modular waveguide mounting accessory specifically designed for on-chip thin-film GaAs waveguides is presented serving as a flexible analytical platform in lieu of conventional attenuated total reflection (ATR) crystals uniquely facilitating macroscopic handling and alignment of such microscopic waveguide structures in real-world application scenarios.

5.
Anal Chem ; 86(16): 8136-41, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25032789

RESUMO

The first combination of mid-infrared (MIR) tunable quantum cascade lasers (tQCLs) with thin-film diamond strip waveguides (DSWGs) suitable for advanced chemical sensing/biosensing is demonstrated. The sensing system is composed of thin diamond films grown on surface-passivated Si wafers via chemical vapor deposition (CVD) and microstructured using inductively coupled plasma (ICP) etching, serving as photonic waveguides for radiation emitted by a broadly tunable quantum cascade laser (tQCL) in the spectral regime of 5.78-6.35 µm (1570-1730 cm(-1)). The characterization of the free-standing diamond waveguides reveals excellent transmission properties across a broad MIR band. As a proof of concept, the detection of acetone in D2O via evanescent field absorption is demonstrated achieving a limit of detection (LOD) as low as 200 pL, which indicates a significant sensitivity improvement compared to conventional MIR slab/strip waveguides reported to date. Providing characteristic absorption features within the tuning range of the tQCL, studies using anisaldehyde as an analyte further corroborate the potential of tQCL-DSWG-based chemical sensors/biosensors.


Assuntos
Diamante/química , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Acetona/análise , Benzaldeídos/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Raios Infravermelhos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
6.
Anal Chem ; 86(1): 783-9, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-24313342

RESUMO

In situ synthesis of bare gold nanoparticles mediated by stainless steel as reducing agent was monitored via infrared attenuated total reflection (IR-ATR) spectroscopy. Gold nanoparticles were directly synthesized within the liquid cell of the ATR unit taking immediate advantage of the stainless steel walls of the ATR cell. As nanoparticles were formed, a layer of particles was deposited at the SiO2 ATR waveguide surface. Incidentally, the absorption bands of water increased resulting from surface-enhanced infrared absorption (SEIRA) effects arising from the presence of the gold nanoparticles within the evanescent field. Next to the influence of the Au(III) precursor concentration and the temperature, the suitability of IR-ATR spectroscopy as an innovative tool for investigating changes of nanoparticles in solution, including their aggregation promoted by an increase of the ionic strength or via a pH decrease, and for detailing the sedimentation process of gold nanoparticles was confirmed.


Assuntos
Ouro/análise , Nanopartículas Metálicas/análise , Soluções/análise , Espectrofotometria Infravermelho/métodos
7.
Anal Chem ; 85(6): 3050-2, 2013 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-23131036

RESUMO

We report the design, fabrication, and first functional verification of mid-infrared (MIR; 3-12 µm) Mach-Zehnder interferometers (MZIs). The developed MIR-MZIs are entirely chip-integrated solid-state devices based on GaAs/AlGaAs technology waveguide fabricated via conventional optical lithography and reactive ion etching (RIE). Thus, fabricated MIR-MZIs were combined with a broadly tunable quantum cascade laser (tQCL) providing a wavelength coverage of 5.78-6.35 µm. MIR-MZIs have been designed with a waveguide width of 5 µm to ensure single mode behavior, avoiding optically undefined interference patterns. Several structures with different opening angles of the Y-junction were fabricated and tested for maximizing IR radiation throughput. This study demonstrates the feasibility of the very first chip-integrated mid-infrared Mach-Zehnder structures via interference patterns produced by minute amounts of water deposited at different positions of the MIR-MZI structure.


Assuntos
Alumínio , Arsenicais , Desenho de Equipamento/métodos , Gálio , Dispositivos Ópticos , Alumínio/química , Arsenicais/química , Gálio/química , Interferometria/métodos , Espectrofotometria Infravermelho/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...