Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Prosthet Dent ; 129(3): 472-477, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34330530

RESUMO

STATEMENT OF PROBLEM: Research evaluating the accuracy of anterior tooth mold templates to computer-aided design and computer-aided manufacture (CAD-CAM) fabricated complete removable dental prostheses (CRDPs) is limited. PURPOSE: The purpose of this in vitro study was to investigate the accuracy of the anterior denture tooth arrangement on CAD-CAM complete removable dental prostheses made with the anterior tooth mold template. MATERIAL AND METHODS: A maxillary and mandibular edentulous model was mounted on a semiadjustable articulator to simulate a patient's maxillary arch. Definitive impressions and jaw relation records were made as per the manufacturer's protocol. A maxillary and mandibular anatomic measuring device was completely seated onto the edentulous models, centered on the edentulous model midline, and horizontally positioned parallel to the mandibular ridge. A medium-size anterior tooth mold template sticker was attached on the anatomic measuring device to identify the maxillary dental midline and incisal edge position and was sent to the manufacturer as the proposed tooth arrangement reference for the definitive complete removable dental prostheses. A total of 10 milled complete removable dental prostheses were generated for 2 groups by using 2 different tooth arrangement techniques. One group (n=5) used the monobloc milling technique without bonding of denture teeth, while the other group (n=5) used the bonding system for denture teeth on the milled denture base. For comparison, a camera mounted on a tripod was used for photographic documentation. Reference markers placed on the edentulous model were used to orient and measure the difference of 4 aspects of the anterior tooth arrangement: average incisal edge position, intercanine distance, midline, and clinical crown length of the left central incisor. The difference values between the tooth mold template and definitive complete removable dental prostheses were statistically analyzed by multivariate ANOVA (α=.05) and 1-sample t tests (adjusted α=.0125). RESULTS: Overall, statistically significant differences were found between the tooth mold template (control) and definitive complete removable dental prostheses at all measuring aspects except for the midline of the midline of the milled arrangement technique (P<.0125). In terms of the midline value, the value of the milled group did not show a significant difference compared with tooth mold template (-0.19 mm). However, the value of the bonded group indicated a significant difference of midline (0.44 mm toward to the left of the tooth mold template midline). When the complete removable dental prosthesis milled denture tooth and complete removable dental prosthesis bonded denture tooth techniques were compared, there was no difference in the tested variables between the milled and the bonded groups (P>.0125). CONCLUSIONS: The tooth mold template did not represent an accurate position for definitive complete removable dental prostheses for either the milled or bonded techniques. The largest differences were found at the average incisal edge of the anterior teeth and the intercanine distance for both groups. However, there was overall no clinical difference between the 2 groups (milled and bonded) of CAD-CAM complete removable dental prostheses.


Assuntos
Planejamento de Dentadura , Boca Edêntula , Humanos , Planejamento de Dentadura/métodos , Desenho Assistido por Computador , Prótese Total , Registro da Relação Maxilomandibular
2.
Eur J Appl Physiol ; 117(2): 323-334, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28078451

RESUMO

PURPOSE: The purpose of the present study was to examine the effects of unilateral fatigue of the knee extensors at different movement velocities on neuromuscular performance in the fatigued and non-fatigued leg. METHODS: Unilateral fatigue of the knee extensors was induced in 11 healthy young men (23.7 ± 3.8 years) at slower (60°/s; FAT60) and faster movement velocities (240°/s; FAT240) using an isokinetic dynamometer. A resting control (CON) condition was included. The fatigue protocols consisted of five sets of 15 maximal concentric knee extensions using the dominant leg. Before and after fatigue, peak isokinetic torque (PIT) and time to PIT (TTP) of the knee extensors as well as electromyographic (EMG) activity of vastus medialis, vastus lateralis, and biceps femoris muscles were assessed at 60 and 240°/s movement velocities in the fatigued and non-fatigued leg. RESULTS: In the fatigued leg, significantly greater PIT decrements were observed following FAT60 and FAT240 (11-19%) compared to CON (3-4%, p = .002, d = 2.3). Further, EMG activity increased in vastus lateralis and biceps femoris muscle following FAT240 only (8-28%, 0.018 ≤ p ≤ .024, d = 1.8). In the non-fatigued leg, shorter TTP values were found after the FAT60 protocol (11-15%, p = .023, d = 2.4). No significant changes were found for EMG data in the non-fatigued leg. CONCLUSION: The present study revealed that both slower and faster velocity fatiguing contractions failed to show any evidence of cross-over fatigue on PIT. However, unilateral knee extensor fatigue protocols conducted at slower movement velocities (i.e., 60°/s) appear to modulate torque production on the non-fatigued side (evident in shorter TTP values).


Assuntos
Articulação do Joelho/fisiologia , Joelho/fisiologia , Movimento/fisiologia , Contração Muscular/fisiologia , Torque , Adulto , Eletromiografia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fadiga Muscular/fisiologia , Músculo Esquelético/fisiologia , Músculo Quadríceps/fisiologia , Adulto Jovem
3.
Rev. cuba. cir ; 16(2): 131-42, mar.-abr. 1977. ilus, tab
Artigo em Espanhol | CUMED | ID: cum-11451

RESUMO

se presentaron los resultados iniciales obtenidos con la nutrición parenteral total en 7 niños del Hospital Pediátrico del Cerro, durante el período posoperatorio. Se describe la técnica y los cuidados necesarios de este proceder, así como los exámenes complementarios previos y de control, y los parámetros empleados para su vigilancia. Los resultados obtenidos abogan por una mayor utilización de la nutrición parenteral total como un excelente recurso terapéutico ante un niño con mal riesgo quirúrgico (AU)


Assuntos
Nutrição Parenteral , Cuidados Pós-Operatórios , Criança
4.
16 de abril ; 2(6): 20-3, mar. 1965. ilus, tab
Artigo em Espanhol | CUMED | ID: cum-20108
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...