Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancer Radiother ; 25(3): 213-221, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33402290

RESUMO

PURPOSE: Helical Tomotherapy (HT) appears as a valuable technique for total body irradiation (TBI) to create highly homogeneous and conformal dose distributions with more precise repositioning than conventional TBI techniques. The aim of this work is to describe the technique implementation, including treatment preparation, planning and dosimetric monitoring of TBI delivered in our institution from October 2016 to March 2019. MATERIAL AND METHOD: Prior to patient care, irradiation protocol was set up using physical phantoms. Gafchromic films were used to assess dose distribution homogeneity and evaluate imprecise patient positioning impact. Sixteen patients' irradiations with a prescribed dose of 12Gy were delivered in 6 fractions of 2Gy over 3 days. Pre-treatment quality assurance (QA) was performed for the verification of dose distributions at selected positions. In addition, in-vivo dosimetry was carried out using optically stimulated luminescence dosimeters (OSLD). RESULTS: Planning evaluation, as well as results of pre-treatment verifications, are presented. In-vivo dosimetry showed the strong consistency of OSLD measured doses. OSLD mean relative dose differences between measurement and calculation were respectively +0,96% and -2% for armpit and hands locations, suggesting better reliability for armpit OSLD positioning. Repercussion of both longitudinal and transversal positioning inaccuracies on phantoms is depicted up to 2cm shifts. CONCLUSION: The full methodology to set up TBI protocol, as well as dosimetric evaluation and pre-treatment QA, were presented. Our investigations reveal strong correspondence between planned and delivered doses shedding light on the dose reliability of OSLD for HT based TBI in-vivo dosimetry.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total/métodos , Fracionamento da Dose de Radiação , Transplante de Células-Tronco Hematopoéticas , Humanos , Linfoma Anaplásico de Células Grandes/terapia , Linfoma de Células T/terapia , Posicionamento do Paciente/métodos , Imagens de Fantasmas , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Radiometria/métodos , Reprodutibilidade dos Testes , Condicionamento Pré-Transplante/métodos
2.
Cancer Radiother ; 13(3): 182-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19272824

RESUMO

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (IMRT) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photontherapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these controls. This paper presents a review of technologies and products that can be used for in vivo dosimetry. It proposes also a reflection on the concepts to develop future devices suitable for this purpose. The technical means with their physical principles are reviewed, the clinical experiences demonstrating the feasibility of new techniques are then summarized and finally, the early clinical use and its impact on clinical practice is review.


Assuntos
Neoplasias/radioterapia , Monitoramento de Radiação/métodos , Radiometria/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Monitoramento de Radiação/instrumentação , Radiometria/instrumentação , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...