Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 6(10): e05163, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33088946

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are part of a class of organic compounds resistant to natural degradation. In this way, heterogeneous photocatalysis becomes useful to degrade persistent organic pollutants, however it can be influenced by environmental variables (i.e.: organic matter) and experimental factors such as: mass of the photocatalyst and irradiation time. The objective of this research was to use a factorial design 2k as a function of the multiple response (MR) to evaluate simultaneously experimental conditions for the photodegradation of polycyclic aromatic hydrocarbons in contaminated mangrove sediment and its application in oil from Potiguar Basin in Brazil. The sediment samples collected in Belmonte city (Southern Bahia state) were contaminated with 0.25 mg kg-1 of Acenaphthene, Anthracene, Benzo[a]Anthracene, Indene[1,2,3cd]pyrene, Dibenzo[ah]anthracene, Benzo[ghi]pyrene. Factors such as mass of the photocatalyst and irradiation time were evaluated in factorial design 22, with triplicate from the central point, to 1g of the PAH contaminated sediment. After performing the experiments, it was found that the best experimental condition for the degradation of all PAHs indicated by MR was the central point (0.5 g of photocatalyst and 12h of irradiation). For such conditions, the half-life of PAHs varied from 3.51 to 9.37 h and the degradation speed constant between 0.0740 to 0.1973 h-1. The comparison of the optimized methodology between photolysis tests and heterogeneous photocatalysis was performed using the Kruskal-Wallis test, which indicated a difference for the reference solution, where heterogeneous photocatalysis was more efficient in the degradation of PAHs. The optimized methodology was apply in samples contaminated with crude oil from Potiguar Basin, no significant difference was observed in the aromatic fraction, using for the Kruskal-Wallis test. Heterogeneous photocatalysis has shown to be a promising remediation technique to remedy aromatic organic compounds in mangrove sediments.

2.
Gynecol Oncol ; 97(2): 588-95, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15863164

RESUMO

OBJECTIVES: The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. METHODS: Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. RESULTS: One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92.1% (CI 95% = 78.6-98.3). The accuracy of sentinel node in predicting the lymph node status was 94.2%. CONCLUSION: Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with (99m)Tc-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection can be avoided.


Assuntos
Linfonodos/diagnóstico por imagem , Compostos de Organotecnécio , Ácido Fítico , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Histerectomia , Excisão de Linfonodo , Linfonodos/patologia , Linfonodos/cirurgia , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Cintilografia , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...