Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Anal Methods ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38682647

RESUMO

An alternative approach to assay iron (Fe) in biodiesel by differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV) is presented herein. The sample treatment involved a simple, rapid, but effective extraction of Fe from biodiesel into an aqueous phase after microemulsion (ME) breaking. Then, Fe was determined as the complex Fe(III)-PAN (1-(2-pyridylazo)-2-naphthol) on a glassy carbon electrode (GCE) in the presence of bismuth (Bi(III)). The extraction induced by microemulsion breaking (EIMB) was achieved by adding 0.80 mL of ultrapure water into a water-in-oil ME containing 7.00 mL biodiesel, 2.70 mL n-propanol and 0.30 mL of 0.25 mol L-1 HNO3 solution. No deliberate addition of surfactant was necessary to form and maintain the ME. The EIMB resulted in a 1.30 mL lower aqueous phase extract (APhEx) and an upper oily phase. DP voltammograms were recorded with a portable potentiostat, showing the potentiality of carrying out the determination out of a central laboratory. Another feature was the non-necessity of deaerating the solution to eliminate the dissolved O2. The limits of detection (LOD) and quantification (LOQ) were 1.7 µg L-1 (140 mg kg-1) and 5.5 µg L-1 (455 mg kg-1), respectively. The accuracy of the method was evaluated by recovery assays of spiked samples, by analyzing a standard reference material and by comparisons with high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS).

2.
Talanta ; 272: 125776, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38428129

RESUMO

Herein, a simple, green, and relatively inexpensive approach to determine nickel (Ni) in biodiesel samples by square wave adsorptive cathodic stripping voltammetry (SWAdCSV) is presented. A method based on the accumulation of Ni as Ni(II)-dimethylglyoxime (Ni(II)(HDMG)2) on the glassy carbon electrode was carried out in a solution containing the aqueous phase extract (APhEx) obtained from an extraction induced by microemulsion breaking (EIMB), which was achieved by adding a few microliters of ultrapure water to a microemulsion composed of biodiesel, n-propanol and a diluted HNO3 solution. The LOD and LOQ were 0.2 µg L-1 and 0.8 µg L-1, respectively, and the accuracy was evaluated by recovery assays of spiked samples and by analyzing a standard reference material. Results obtained from a comparative method (HR-CS GF AAS) were also used for this evaluation. The method was applied to biodiesel samples produced from different feedstocks. To the best of the authors knowledge, it is the first time that: 1) Ni in biodiesel is determined by a voltammetric method; 2) EIMB is applied to extract Ni from this matrix and 3) this type of sample preparation method is used with adsorptive stripping voltammetry.

3.
Hematol., Transfus. Cell Ther. (Impr.) ; 43(4): 410-416, Oct.-Dec. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1350825

RESUMO

ABSTRACT Background: The screening of Trypanosoma cruzi-infected blood donors using two serological techniques frequently leads to conflicting results. This fact prompted us to evaluate the diagnostic performance of four "in-house" immunodiagnostic tests and two commercially available enzyme-linked immunosorbent assays (ELISAs). Material and Methods: One hundred and seventy-nine blood donors, whose screening for Chagas disease was doubtful, underwent three in-house ELISAs, one in-house immunoblotting test (TESA-blot), and two commercial ELISAs (bioMérieux and Wiener) in an attempt to define the presence or absence of infection. Simultaneously, 29 donors with previous positive results from three conventional serological tests and 30 donors with constant negative results were evaluated. Results: The ELISA-Wiener showed the highest rate in sensitivity (98.92%) and the ELISA-bioMérieux, the highest specificity (99.45%), followed by the TESA-blot, which showed superior performance, with lower false-negative (2.18%) and false-positive (1.12%) rates. In series, the combination composed of the TESA-blot and ELISA-bioMérieux showed slightly superior performance, with trifunctional protein deficiency (TFP) = 0.01%. Conclusion: Our study confirms the high sensitivity and specificity of commercial kits. To confirm the presence or absence of T. cruzi infection, the combination of TESA-blot and ELISA-bioMérieux may be suggested as the best alternative. Individually, the TESA-blot performed the closest to the gold standard; however, it is not commercially available.


Assuntos
Humanos , Trypanosoma cruzi , Testes Imunológicos , Doença de Chagas , Doadores de Sangue , Ensaio de Imunoadsorção Enzimática , Immunoblotting
4.
Hematol Transfus Cell Ther ; 43(4): 410-416, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32943369

RESUMO

BACKGROUND: The screening ofTrypanosoma cruzi-infected blood donors using two serological techniques frequently leads to conflicting results. This fact prompted us to evaluate the diagnostic performance of four "in-house" immunodiagnostic tests and two commercially available enzyme-linked immunosorbent assays (ELISAs). MATERIAL AND METHODS: One hundred and seventy-nine blood donors, whose screening for Chagas disease was doubtful, underwent three in-house ELISAs, one in-house immunoblotting test (TESA-blot), and two commercial ELISAs (bioMérieux and Wiener) in an attempt to define the presence or absence of infection. Simultaneously, 29 donors with previous positive results from three conventional serological tests and 30 donors with constant negative results were evaluated. RESULTS: The ELISA-Wiener showed the highest rate in sensitivity (98.92%) and the ELISA-bioMérieux, the highest specificity (99.45%), followed by the TESA-blot, which showed superior performance, with lower false-negative (2.18%) and false-positive (1.12%) rates. In series, the combination composed of the TESA-blot and ELISA-bioMérieux showed slightly superior performance, with trifunctional protein deficiency (TFP)=0.01%. CONCLUSION: Our study confirms the high sensitivity and specificity of commercial kits. To confirm the presence or absence of T. cruzi infection, the combination of TESA-blot and ELISA-bioMérieux may be suggested as the best alternative. Individually, the TESA-blot performed the closest to the gold standard; however, it is not commercially available.

5.
Talanta ; 220: 121337, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32928386

RESUMO

In this work, a simple and reliable method was proposed for sulfur determination in different matrices using the diatomic molecule SiS via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) and direct analysis of solid samples. This investigation was carried out using six sulfur standard solutions, Na2S, Na2SO4, BeSO4, thiourea, l-cysteine and sulfamic acid, and nine certified reference materials (CRMs). All measurements were performed using the SiS analytical line at 282.910 nm with 400 µg Zr as permanent modifier and 20 µg Si in basic media as molecule forming reagent. The optimized pyrolysis and vaporization temperatures were 1200 and 2000 °C, respectively. The investigated sulfur sources presented similar analytical signals and statistically equal Aint values for the SiS molecule. Calibration curves with aqueous sulfur standard solutions were used to achieve the limits of detection (LOD) and quantification (LOQ) and the characteristic mass (m0) of 8.8, 29 ng mg-1 and 9.8 ng, respectively, and to determine sulfur in the CRMs. Considering that the investigated wavelength range contained multiple SiS lines, the LOD (2.5 ng mg-1), LOQ (8.4 ng mg-1), m0 (1.0 ng) and the working range (0.008-2.5 µg) were improved by using ten SiS lines (30 pixels) for the measurements. Despite differences in the CRM matrices, the SiS molecule was successfully employed to determine their sulfur concentrations, which were in agreement with the certified values at a confidence level of 95% through Student or Welch t-tests. Therefore, a simple, versatile and reliable method using the SiS molecule was developed to perform sulfur determination in a great variety of sample matrices via HR-CS GF MAS and direct analysis of solid samples.

6.
Talanta ; 134: 224-231, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25618661

RESUMO

Direct solid sample analysis with graphite furnace atomic absorption spectrometry (SS-GF AAS) was investigated initially with the intention of developing a method for the determination of total As in fish and other seafood. A mixture of 0.1% Pd+0.06% Mg+0.06% Triton X-100 was used as the chemical modifier, added in solution over the solid samples, making possible the use of pyrolysis and atomization temperatures of 1200 °C and 2400 °C, respectively. The sample mass had to be limited to 0.25 mg, as the integrated absorbance did not increase further with increasing sample mass. Nevertheless, the recovery of As from several certified reference materials was of the order of 50% lower than the certified value. Strong molecular absorption due to the phosphorus monoxide molecule (PO) was observed with high-resolution continuum source AAS (HR CS AAS), which, however, did not cause any spectral interference. A microwave-assisted digestion with HNO3/H2O2 was also investigated to solve the problem; however, the results obtained for several certified reference materials were statistically not different from those found with direct SS-GF AAS. Accurate values were obtained using inductively coupled plasma mass spectrometry (ICP-MS) to analyze the digested samples, which suggested that organic As compounds are responsible for the low recoveries. HPLC-ICP-MS was used to determine the arsenobetaine (AB) concentration. Accurate results that were not different from the certified values were obtained when the AB concentration was added to the As concentration found by SS-GF AAS for most certified reference materials (CRM) and samples, suggesting that SS-GF AAS could be used as a fast screening procedure for inorganic As determination in fish and seafood.


Assuntos
Arsenicais/análise , Bivalves/química , Produtos Pesqueiros/análise , Peixes/metabolismo , Alimentos Marinhos/análise , Animais , Magnésio/química , Octoxinol/química , Paládio/química , Padrões de Referência , Espectrofotometria Atômica/métodos
7.
Food Chem ; 173: 1073-82, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25466127

RESUMO

An analytical method for determination of arsenic species (inorganic arsenic (iAs), methylarsonic acid (MA), dimethylarsinic acid (DMA), arsenobetaine (AB), trimethylarsine oxide (TMAO) and arsenocholine (AC)) in Brazilian and Spanish seafood samples is reported. This study was focused on extraction and quantification of inorganic arsenic (iAs), the most toxic form. Arsenic speciation was carried out via LC with both anionic and cationic exchange with ICP-MS detection (LC-ICP-MS). The detection limits (LODs), quantification limits (LOQs), precision and accuracy for arsenic species were established. The proposed method was evaluated using eight reference materials (RMs). Arsenobetaine was the main species found in all samples. The total and iAs concentration in 22 seafood samples and RMs ranged between 0.27-35.2 and 0.02-0.71 mg As kg(-1), respectively. Recoveries ranging from 100% to 106% for iAs, based on spikes, were achieved. The proposed method provides reliable iAs data for future risk assessment analysis.


Assuntos
Arsênio/análise , Cromatografia Líquida de Alta Pressão/métodos , Análise de Alimentos/métodos , Espectrometria de Massas/métodos , Alimentos Marinhos/análise
8.
Materials (Basel) ; 7(12): 7907-7924, 2014 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-28788283

RESUMO

Crystalline cellulose chemically modified through a reaction with sodium trimetaphosphate (STMP) in an acidic or basic condition yielded Cel-P4 and Cel-P10. These phosphated solids were characterized by elemental analysis, X-ray diffraction (XRD), infrared (IR) spectroscopy, scanning electron microscopy (SEM), nuclear magnetic resonance (NMR) at the solid state for phosphorus nucleus and dispersive X-ray energy. The elemental results demonstrated that the phosphorylation reaction was more efficient in the basic medium, as supported by the amount of phosphorous content. The synthesized biomaterials decreased in crystallinity in comparison to the precursor cellulose, with an increase in roughness and present two distinct phosphorus environments in the formed structure. The phosphated cellulose in an alkaline condition was applied to sorb the drug ranitidine. This process was applied in varying pH, time, temperature and concentration. The best sorption kinetic model to fit the experimental data was the pseudo-second-order with a coefficient correlation of 0.8976, and the Langmuir isotherm model was the most adjusted to the variation in concentration. The efficient drug sorption has a low dependence on temperature, with maximum values of 85.0, 82.0 mg and 85.7 mg·g-1 for Cel-P10 at 298, 308 and 318 K, respectively. The best sorption occurred at pH = 6 with a saturation time of 210 min.

9.
Rev. bras. farmacogn ; 23(2): 200-206, Mar.-Apr. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-669509

RESUMO

Erythrina velutina Willd., Fabaceae, known as "mulungu", is a tree of tropical regions, as northeastern Brazil. Its bark is used in folk medicine as tranquilizer, sedative and insomnia. This study aimed to characterize the stem and leaf anatomy and to provide subsidies to quality control of the plant drug due to its wide use in folk medicine as well as its differentiation from other species with the same popular name. Samples were collected at Cuité, in Paraíba State, Brazil, fixed in FAA50, semipermanent slides were made, following usual procedures in plant anatomy. The stem shows a cylindrical contour, covered by a uniseriate epidermis covered by a thickened cuticle. It shows claviform glandular and branched trichomes with uniseriate stalk. Secretory cavities are into the phloem. The leaf epidermis has branched and glandular trichomes and anisocytic and paracytic stomata, on both sides, with predominance of branched trichomes and stomata on abaxial surface. Secretory cavities in stem and leaf, types of trichomes and stomata, its location and distribution constitute diagnostic characters for this specie. The structural characterization of the stem and leaf allows its distinction from other ones of this genus, ensuring safety for commercial pharmacological uses, allowing certification of the authenticity of raw material.

10.
Talanta ; 85(1): 681-6, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21645758

RESUMO

Two simple methods have been developed to determine cadmium and lead in different kinds of beverages and vinegar leached from pewter cups produced in Brazil. Leaching experiments have been carried out with different solutions: beer, sugar cane spirit, red and white wine, vinegar and a 3% acetic acid solution. The solutions were kept in cups with and without solder for 24h. Lead and cadmium have been determined using graphite furnace atomic absorption spectrometry with deuterium background correction. The limits of detection were 0.05 and 1.4 µg L(-1), and the characteristic mass was 1.0 pg and 19 pg for Cd and Pb, respectively. With the developed methods it was possible to determine accurately cadmium and lead by direct analysis in these liquids and to evaluate the leaching of these metals from pewter cups. The results presented in this work show that pewter cups are not cadmium- and lead-free; this point goes against the manufacturers' declaration that their products are lead-free.


Assuntos
Cádmio/análise , Utensílios de Alimentação e Culinária , Chumbo/análise , Bebidas/análise , Brasil , Limite de Detecção , Espectrofotometria Atômica/métodos
11.
Talanta ; 83(2): 637-43, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21111185

RESUMO

Lubricating oils are used to decrease wear and friction of movable parts of engines and turbines, being in that way essential for the performance and the increase of that equipment lifespan. The presence of some metals shows the addition of specific additives such as detergents, dispersals and antioxidants that improve the performance of these lubricants. In this work, a method for determination of calcium, magnesium and zinc in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three-component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, it was compared with ABNT NBR 14066 standard method, which consists in diluting the sample with AVK and in quantification by F AAS. Two other validating methods have also been used: the acid digestion and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages in relation to the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous inorganic standards for calibration. The limits of detection for calcium, magnesium and zinc were 1.3 µg g(-1), 0.052 µg g(-1) and 0.41 µg g(-1), respectively. Concentrations of calcium, magnesium and zinc in six different samples obtained by the developed method did not differ significantly from the results obtained by the reference methods at the 95% confidence level (Student's t-test and ANOVA). Therefore, the proposed method becomes an efficient alternative for determination of metals in lubricating oil.


Assuntos
Cálcio/análise , Magnésio/análise , Espectrofotometria Atômica/métodos , Zinco/análise , Brasil , Calibragem , Técnicas de Química Analítica , Detergentes/farmacologia , Indústrias , Octoxinol/farmacologia , Óleos/química
12.
Mem Inst Oswaldo Cruz ; 105(6): 800-5, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20944996

RESUMO

Epidemiological screening combined with serological tests has become an important tool at blood banks for the characterization of donors with or without Trypanosoma cruzi infection. Thus, the objective of the present study was to describe the sociodemographic and epidemiological characteristics of blood donors with non-negative serology for T. cruzito determine possible risk factors associated with serological ineligibility. Sociodemographic and epidemiological data were collected by analysis of patient histories and interviews. The data were analyzed descriptively using absolute and relative frequencies and odds ratio (OR) evaluation. The frequency of serological ineligibility was 0.28%, with a predominance of inconclusive reactions (52%) and seropositivity among first-time donors (OR = 607), donors older than 30 years (OR = 3.7), females (OR = 1.9), donors from risk areas (OR = 4) and subjects living in rural areas (OR = 1.7). The risk of seropositivity was higher among donors who had contact with the triatomine vector (OR = 11.7) and those with a family history of Chagas disease (OR = 4.8). The results demonstrate the value of detailed clinical-epidemiological screening as an auxiliary tool for serological definition that, together with more specific and more sensitive laboratory methods, will guarantee a higher efficacy in the selection of donors at blood centres.


Assuntos
Anticorpos Antiprotozoários/sangue , Doadores de Sangue , Doença de Chagas/diagnóstico , Trypanosoma cruzi/imunologia , Adulto , Brasil/epidemiologia , Doença de Chagas/sangue , Doença de Chagas/epidemiologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , População Rural , Fatores Socioeconômicos , População Urbana
13.
Mem. Inst. Oswaldo Cruz ; 105(6): 800-805, Sept. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-560666

RESUMO

Epidemiological screening combined with serological tests has become an important tool at blood banks for the characterization of donors with or without Trypanosoma cruzi infection. Thus, the objective of the present study was to describe the sociodemographic and epidemiological characteristics of blood donors with non-negative serology for T. cruzito determine possible risk factors associated with serological ineligibility. Sociodemographic and epidemiological data were collected by analysis of patient histories and interviews. The data were analyzed descriptively using absolute and relative frequencies and odds ratio (OR) evaluation. The frequency of serological ineligibility was 0.28 percent, with a predominance of inconclusive reactions (52 percent) and seropositivity among first-time donors (OR = 607), donors older than 30 years (OR = 3.7), females (OR = 1.9), donors from risk areas (OR = 4) and subjects living in rural areas (OR = 1.7). The risk of seropositivity was higher among donors who had contact with the triatomine vector (OR = 11.7) and those with a family history of Chagas disease (OR = 4.8). The results demonstrate the value of detailed clinical-epidemiological screening as an auxiliary tool for serological definition that, together with more specific and more sensitive laboratory methods, will guarantee a higher efficacy in the selection of donors at blood centres.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticorpos Antiprotozoários/sangue , Doadores de Sangue , Doença de Chagas , Trypanosoma cruzi/imunologia , Brasil , Doença de Chagas/sangue , Doença de Chagas , Ensaio de Imunoadsorção Enzimática , Fatores de Risco , População Rural , Fatores Socioeconômicos , População Urbana
14.
Rev. bras. hematol. hemoter ; 32(supl.1): 22-39, maio 2010. tab
Artigo em Português | LILACS | ID: lil-554168

RESUMO

A falta de critérios diagnósticos padronizados, amplamente utilizados, pode comprometer tanto a avaliação real da incidência da doença contra hospedeiro crônica bem como a correlação de sua gravidade com a taxa de mortalidade pós-transplante. Na I Reunião de Diretrizes da Sociedade Brasileira de Transplante de Medula Óssea, realizada em junho de 2009, o Grupo de Estudos de DECH Brasil - Seattle (GEDECH), baseado na realidade dos Centros brasileiros, apresentou as recomendações para diagnóstico, classificação, profilaxia e tratamento da doença enxerto contra hospedeiro crônica propostas pelo National Institutes of Health. Estas propostas incluíram padronização das características utilizadas no diagnóstico e ferramentas para a pontuação dos órgãos envolvidos e avaliação global da gravidade a serem utilizados em estudos clínicos da doença enxerto contra hospedeiro crônica. Estes critérios são úteis para uma melhor análise da incidência desta doença, além de poder avaliar a gravidade do comprometimento de um órgão ou sítio envolvido e a influência na mortalidade tardia do transplante. A profilaxia e os tratamentos propostos para esta importante complicação dos transplantes de células-tronco hematopoéticas foram discutidos e graduados de acordo com níveis de evidência estabelecidos pelo National Institutes of Health.


The lack of widely-used standardized diagnostic criteria may impair both the true evaluation of chronic graft-versus-host disease and the correlation of its severity with transplant-related mortality. At the I Consensus of the Brazilian Society of Bone Marrow Transplantation - SBTMO that took place in June 2009, the Group of GVHD Studies Brazil-Seattle (GEDECH), presented the guidelines for diagnosis, classification, prophylaxis and treatment of chronic GVHD as proposed by the National Institutes of Health and based on the reality in Brazilian Centers. These proposals, including standardization of features used in diagnosis and tools to score involved organs and to assess the overall severity, should be used in clinical studies of chronic graft-versus-host disease. These criteria are useful to better analyze the incidence of this disease, in addition to evaluate the extension of the involvement of organs or the site affected and its influence on late transplantation mortality. Prophylaxis and treatment proposed for this important complication of hematopoietic stem cell transplantations were discussed and graded according to the levels of evidence established by the National Institutes of Health.


Assuntos
Humanos , Transplante de Medula Óssea , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro
15.
J Hazard Mater ; 179(1-3): 507-14, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20347519

RESUMO

Pb was incorporated to a series of cement matrices, which were submitted to different testes of solidified/stabilized product. The leaching behaviors of aqueous solution were monitored by graphite furnace atomic absorption spectroscopy (GF-AAS). The mechanical strengths were evaluated by unconfined compressive strength (UCS) at 7 and 28 ages. Data are discussed in terms of metal mobility along the cement block monitored by X-ray fluorescence (XRF) spectrometry. Complementary techniques, namely, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), thermal gravimetric analysis (TGA), small angle X-ray scattering (SAXS) and X-ray diffraction spectroscopy (XRD) were employed in the characterization of the modified matrices. The Pb incorporated matrices have shown that a long cure time is more suitable for avoiding metal leaching. At pH 8 lower Pb leaching took place both for both short and long cure time. For a longer cure period there is a decreasing in the compressive strength. TGA and DRIFTS analyses show that the resistance fall observed in the UCS tests in the sample with Pb are not caused by hydration excess. XRF analyses show that there is a lower Ca concentration in the matrix in which Pb was added.


Assuntos
Poluentes Ambientais/química , Poluição Ambiental/prevenção & controle , Chumbo/química , Materiais de Construção , Concentração de Íons de Hidrogênio , Espalhamento de Radiação , Solubilidade , Espectrometria por Raios X , Espectrofotometria Atômica , Espectroscopia de Infravermelho com Transformada de Fourier , Termogravimetria , Difração de Raios X , Raios X
16.
Talanta ; 77(1): 400-6, 2008 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-18804652

RESUMO

Two analytical methods for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry without prior sample digestion have been compared: direct solid sampling analysis (SS) and slurry sampling (SlS). Besides the conventional modifier mixture of palladium and magnesium nitrates (10 microg Pd+3 microg Mg), 0.05% (v/v) Triton X-100 has been added to improve the penetration of the modifier solution into the solid sample, and 0.1% H(2)O(2) in order to promote an in situ digestion for SS. For SlS, 30 microg Pd, 12 microg Mg and 0.05% (v/v) Triton X-100 have been used as the modifier mixture. Under these conditions, and using a pyrolysis temperature of 800 degrees C, essentially no background absorption was observed with an atomization temperature of 1600 degrees C. About 2 mg of sample have been typically used for SS, although as much as 3-5 mg could have been introduced. In the case of SlS multiple injections had to be used to achieve the sensitivity required for this determination. Calibration against aqueous standards was feasible for both methods. The characteristic mass obtained with SS was 0.6 pg, and that with SlS was 1.0 pg. The limits of detection were 0.4 and 0.7 ng g(-1), the limits of quantification were 1.3 and 2.3 ng g(-1) and the relative standard deviation (n=5) was 6-16% and 9-23% for SS and SlS, respectively. The accuracy was confirmed by the analysis of certified reference materials. The two methods were applied for the determination of cadmium in six wheat flour samples acquired in supermarkets of different Brazilian cities. The cadmium content varied between 8.9+/-0.5 and 13+/-2 ng g(-1) (n=5). Direct SS gave results similar to those obtained with SlS using multi-injections; the values of both techniques showed no statistically significant difference at the 95% confidence level. Direct SS was finally adopted as the method of choice, due to its greater simplicity, the faster speed of analysis and the better figures of merit.


Assuntos
Cádmio/análise , Elétrons , Farinha/análise , Espectrofotometria Atômica/métodos , Temperatura , Triticum/química
17.
Rev. bras. hematol. hemoter ; 30(2): 153-161, mar.-abr. 2008. ilus, tab
Artigo em Português | LILACS | ID: lil-496284

RESUMO

Fotoferese extracorpórea é uma modalidade de terapia celular que tem demonstrado eficácia e segurança em pacientes portadores de doenças auto-imunes e mediadas por células T, incluindo esclerodermia, linfoma de células T cutâneo/ Síndrome de Sézary e doença enxerto-contra-hospedeiro após transplante de células-tronco hematopoiéticas. Tem sido empregada, ainda, com o intuito de induzir tolerância em transplantes de órgãos sólidos. O tratamento se baseia no efeito biológico de uma substância fotossensibilizante, o 8-metoxipsoraleno, e da radiação ultravioleta A, nas células mononucleares coletadas por aférese e reinfundidas ao paciente. O mecanismo de ação parece ser devido à indução de imunidade anticlonotípica direcionada a clones patogênicos de células T. O tratamento induz a apoptose de células T patogênicas, e a ativação de células apresentadoras de antígenos desempenha papel importante no processo imunomodulador.


Extracorporeal photopheresis is a method of cell therapy that has demonstrated efficacy in autoimmune diseases, cutaneous T-cell lymphoma/Sézary syndrome and graft-versus-host disease after hematopoietic stem-cell transplantation. This technique has also been employed as a treatment strategy to induce tolerance after solid organ transplants. Treatment is based on the biological effect of ultraviolet A radiation and a photosensitizing drug, 8-methoxypsoralen, on mononuclear cells collected by apheresis and reinfused into the patient. The suggested mechanism of action is related to the induction of anticlonotypic immunity directed against pathogenic clones of T lymphocytes. Treatment induces apoptosis of pathogenic T-cells, and it appears that activation of antigen-presenting cells has an important role in this process.


Assuntos
Humanos , Ficusina , Doença Enxerto-Hospedeiro , Linfoma , Fotoferese
18.
Talanta ; 74(5): 1378-84, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371793

RESUMO

A new method for F AAS determination of sodium and potassium in biodiesel using water-in-oil microemulsion as sample preparation is proposed. The method was investigated for biodiesel produced from different sources, as soybean, castor and sunflower oil and animal fat and was also applied for vegetable oils. The optimized condition for microemulsion formation was 57.6% (w/w) of n-pentanol, 20% (w/w) of biodiesel or vegetable oil, 14.4% (w/w) of Triton X-100 and 8% (w/w) of water (aqueous standard of KCl or NaCl in/or diluted HNO(3)). The optimized instrumental parameters were: aspiration rate of 2 mL min(-1) and the flame composition of 0.131 of C(2)H(2)/air ratio. For comparison purpose, the determination of sodium and potassium were also carried out according to European norms (EN 14108 and EN 14109, respectively). These norms are applied for determination of sodium and potassium in fatty acid methylic ester samples and consist in the sample dilution using organic solvent and determination by F AAS. The stability of microemulsified aqueous standards and samples was investigated and it was found to be stable for at least 3 days while the organic standard diluted with xylene showed a decrease around of 15% in the analytical signal in 1h. The limits of detection were 0.1 microg g(-1) and 0.06 microg g(-1) and the obtained characteristic concentrations were 25 microg L(-1) and 28 microg L(-1) for sodium and potassium, respectively. The proposed method presented two times better limits of detection and better precision (0.4-1.0%) when compared with the dilution technique (1.5-4.5%). The accuracy of the method was evaluated through recovery tests and comparison with the results obtained by dilution technique. The recoveries ranged from 95% to 115% for biodiesel and 90% to 115% for vegetable oil samples. Comparison between the results obtained for biodiesel by both methods showed no significant differences at the 95% confidence level according to a Student's t-test. This study shows that the proposed method based on microemulsion as sample preparation can be applied as an efficient alternative for sodium and potassium determination in biodiesel samples.


Assuntos
Emulsões/química , Gorduras/química , Gasolina/análise , Óleos de Plantas/química , Potássio/análise , Sódio/análise , Espectrofotometria Atômica/métodos , Ionização de Chama , Métodos , Microquímica , Octoxinol , Reprodutibilidade dos Testes , Espectrofotometria Atômica/normas
19.
Talanta ; 74(5): 1385-91, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371794

RESUMO

In recent work, it has been shown that electrothermal atomic absorption spectrometry (ET AAS) can be used to differentiate between volatile and non-volatile nickel and vanadium compounds in crude oil. In the present work, the distribution of these two groups of compounds over different fractions of crude oil was investigated. For this purpose two crude oil samples were separated in two steps: firstly, the asphaltenes were precipitated with n-heptane, and secondly, the maltenes were loaded on a silica column and eluted with solvents of increasing polarity. The four fractions of maltenes eluted from silica column were: F1, saturated and light aromatics; F2, polyaromatics; F3, resins; and F4, polar compounds. Fractions F1 and F2 were further investigated using gas chromatography, and all fractions were characterized by CHN analysis, confirming the increase of aromatics in the fractions 2, 3, 4 and asphaltenes. For the determination of Ni and V by ET AAS, oil-in-water emulsions were prepared. The speciation analysis was carried out measuring without chemical modifier (stable compounds) and with 20 microg palladium (total Ni and V) and the volatile fraction was calculated by difference. The limits of detection were 0.02 microg g(-1) and 0.06 microg g(-1), for Ni and V, respectively, based on an emulsion of 2g of oil in 10 mL. The volatile species of Ni and V were associated with fractions F3 and F4, while only thermally stable Ni and V was precipitated in part together with the asphaltenes.


Assuntos
Níquel/análise , Petróleo/análise , Espectrofotometria Atômica/métodos , Compostos de Vanádio/análise , Fracionamento Químico/métodos
20.
Talanta ; 71(5): 1877-85, 2007 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-19071537

RESUMO

A method for the direct determination of volatile and non-volatile nickel and vanadium compounds in crude oil without previous treatment using direct solid sampling graphite furnace atomic absorption spectrometry is proposed. The crude oil samples were weighed directly onto solid sampling platforms using a microbalance and introduced into a transversely heated solid sampling graphite tube. In previous work of our group losses of volatile nickel and vanadium compounds have been detected, whereas other nickel and vanadium compounds were thermally stable up to 1300 and 1600 degrees C, respectively. In order to avoid this problem different chemical modifiers (conventional and permanent) have been investigated. With 400microg of iridium as permanent modifier, the signal started to drop already after two atomization cycles, possibly because of an interaction of nickel (which is a catalyst poison) with iridium. Twenty micrograms of palladium applied in each determination was found to be optimum for both elements. The palladium was deposited on the platform and submitted to a drying step at 150 degrees C for 75s. After that the sample was added onto the platform and submitted to the furnace program. The influence of sample mass on the linearity of the response and on potential measurement errors was also investigated using four samples with different nickel content. For the sample with the lowest nickel concentration the relationship between mass and integrated absorbance was found to be non-linear when a high sample mass was introduced. It was suspected that the modifier had not covered the entire platform surface, which resulted in analyte losses. This problem could be avoided by using 40microL of 0.5g L(-1) Pd with 0.05% Triton X-100. Calibration curves were established with and without modifier, with aqueous standards, oil-in-water emulsions and the certified reference material NIST SRM 1634c (trace metals in residual fuel oil). The sensitivity for aqueous standards and emulsions was close to that for SRM 1634c, making possible the use of aqueous standards for calibration. The limits of detection and quantification obtained for nickel and vanadium under this condition were found to be 0.02 and 0.06microg g(-1), respectively, for both elements, based on 10mg of sample. Nickel and vanadium were determined in the samples with (total Ni and V) and without the use of Pd (thermally stable compounds), and the concentration of volatile compounds was calculated by difference. The results were compared with those obtained by high-resolution continuum source graphite furnace atomic absorption spectrometry by emulsion technique; no significant differences were found for total Ni and V at the 95% confidence level according to a Student's t-test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...