Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Perinat Med ; 47(2): 252-257, 2019 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-30183667

RESUMO

Background Prematurity and its respective comorbidities may result in longer periods of mechanical ventilation in intensive care units (ICU). A method for the assessment of organic maturity would be useful for this population. Heart rate variability (HRV), as an indicator of homeostasis, is a well-established tool for this approach. The objective of the study was to assess HRV in intubated preterm infants in ICU immediately prior to extubation and correlate HRV with clinical evaluation outcomes. Methods A total of 46 preterm infants, 13 (28.2%) males, were prospectively studied and divided into a group with failed extubation (FEG: n=11) and a group with successful extubation (SEG: n=35). HRV was evaluated in time, frequency and nonlinear domains with a Polar RS800 device. HRV measurements were assessed with Kubios HRV Premium Software and statistically analyzed with the StatsDirect Statistical Software, version 1.9.2015 (2002). P<0.05 values were considered as statistically significant. Results There were no significant differences between heart rate variables of failed and successful extubation when analyzing the total group. However, the analysis of the sub-group of preterm infants weighing less than 1000 g showed a clear differentiation between the groups, when the nonlinear variables (approximate entropy, sample entropy and multiscale entropy 1, 2 and 3) were used, demonstrating that the group with successful extubation shows greater complexity and, therefore, relatively greater autonomic stability. Conclusion HRV was effective in predicting failed extubation in preterm infants when evaluated in a nonlinear domain and in preterm infants weighing less than 1000 g.


Assuntos
Extubação , Frequência Cardíaca/fisiologia , Doenças do Prematuro/terapia , Monitorização Fisiológica/métodos , Respiração Artificial , Extubação/efeitos adversos , Extubação/métodos , Peso ao Nascer , Brasil , Correlação de Dados , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Doenças do Prematuro/etiologia , Masculino , Avaliação de Resultados em Cuidados de Saúde , Valor Preditivo dos Testes , Estudos Prospectivos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos
2.
J Pediatr Surg ; 38(4): E11, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12677598

RESUMO

The case of a newborn infant who presented thrombosis in the abdominal portion of the aorta, which resulted in the complete occlusion is reported. Diagnosis was made using Doppler echocardiography. The initial therapeutic approach was clinical support, but as the thrombi started to increase in size (secondary thrombosis) and evolved to the infrarenal terminal aorta, anticoagulation with heparin was indicated. The total disappearance of both the secondary thrombosis and the embolus was evidenced by a subsequent echocardiography after the anticoagulation therapy.


Assuntos
Anticoagulantes/uso terapêutico , Aorta Abdominal , Doenças da Aorta/tratamento farmacológico , Comunicação Interatrial/complicações , Heparina/uso terapêutico , Terapia Trombolítica , Trombose/tratamento farmacológico , Doenças da Aorta/complicações , Humanos , Recém-Nascido , Falência Renal Crônica/complicações , Trombose/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA