Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
3.
Fisioter. Pesqui. (Online) ; 29(3): 270-277, jul.-set. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1421472

RESUMO

ABSTRACT The use of support devices may facilitate the perception of pelvic floor muscle (PFM) contraction, which is difficult to be performed. Therefore, this study aimed to compare the perception of PFM contraction in the sitting position during the use of two different support devices on women with PFM dysfunction. This is a cross-sectional study performed with 37 women with stress or mixed urinary incontinence (UI). All women performed three free PFM contractions sitting on a chair, followed by three contractions using each support device (sand pads and a cylindrical foam, which provide sciatic and perineal support, respectively). Women scored the perception of PFM contraction from 1 to 5, as well as the perception of facilitation of contraction (higher grades show better results) and discomfort (higher grades show more discomfort) when compared with free contraction. The cylindrical foam presented similar results to sand pads for the perception of PFM contraction (2.84±1.61 vs. 3.19±1.43; p=0.34) and facilitation of contraction (3.38±1.34 vs. 3.19±1.54; p=0.61), as well as for their discomfort (1.83±1.23 vs. 1.5±1.16; p=0.20). Of all women, 57% preferred sand pads. Thus, both sand pads (sciatic support) and the cylindrical foam (perineal support) improved the perception of PFM contraction and facilitation of contraction in the sitting position of women with PFM dysfunction when compared with sitting with no device. The two devices presented no difference between them.


RESUMO O uso de dispositivos de suporte pode auxiliar na percepção da contração dos músculos do assoalho pélvico (AP). O objetivo deste estudo foi, comparar na posição sentada, a percepção da contração dos músculos do AP durante o uso de dois tipos diferentes de dispositivos, em mulheres com disfunção dos músculos do AP. Para tanto, foi realizado um estudo transversal com 37 mulheres com incontinência urinária (IU) de esforço ou mista. Primeiro as participantes faziam três contrações livres dos músculos do AP sem o uso de dispositivos, sentadas em uma cadeira. Em seguida, faziam três contrações utilizando cada um dos dois dispositivos: almofadas de areia e uma espuma cilíndrica, que forneciam apoio isquiático e perineal, respectivamente. As pacientes atribuíram nota de 1 a 5 para a percepção que tiveram da contração dos músculos do AP, da facilitação da contração (quanto maior a nota, melhor o resultado) e do desconforto com o dispositivo (quanto maior a nota, maior o desconforto) em comparação às contrações livres. Como resultados principais, verificou-se que o uso da almofada cilíndrica foi similar ao das almofadas de areia para a percepção da contração dos músculos do AP (2,84±1,61 vs. 3,19±1,43; p=0,34), e da facilitação da contração (3,38±1,34 vs. 3,19±1,54; p=0,61), assim como do desconforto (1,83±1,23 vs. 1,5±1,16; p=0,20). Entre as participantes, 57% relataram preferir as almofadas de areia. Concluiu-se que em mulheres com incontinência urinária, tanto as almofadas de areia (apoio isquiático) quanto a espuma cilíndrica (apoio perineal) melhoraram a percepção da contração e facilitaram a contração dos músculos do assoalho pélvico na posição sentada, não havendo, no entanto, diferença entre os dispositivos.


RESUMEN Las herramientas de apoyo pueden ayudar en la percepción de la contracción de los músculos del suelo pélvico (SP), que no siempre es fácil de obtener su medición. El objetivo de este estudio fue comparar si dos tipos diferentes de herramientas ayudan a las mujeres con disfunción muscular del SP a contraer estos músculos en posición sentada. Para ello, se realizó un estudio transversal con 37 mujeres con incontinencia urinaria (IU) de esfuerzo o mixta. Primero, las participantes realizaron tres contracciones libres de los músculos del SP sentadas en una silla, sin el uso de herramientas de apoyo. Luego, realizaron tres contracciones utilizando cada uno de los dos dispositivos de apoyo: almohadillas de arena y espuma cilíndrica, que brindan apoyo isquiático y perineal, respectivamente. Las participantes deberían asignar una puntuación de 1 a 5 cuanto a su percepción de la contracción muscular del SP, de la facilitación de la contracción (cuanto mayor sea la puntuación, mejor será el resultado) y la incomodidad con la herramienta (cuanto mayor sea la puntuación, mayor será la incomodidad) en comparación con las contracciones libres. Los principales resultados encontrados apuntan que el uso de la almohadilla cilíndrica fue similar al de las almohadillas de arena en cuanto a su percepción de la contracción de los músculos del SP (2,84±1,61 vs. 3,19±1,43; p=0,34), y la facilitación de la contracción (3,38±1,34 vs. 3,19±1,54; p=0,61), así como la incomodidad (1,83±1,23 vs. 1,5±1,16; p=0,20). El 57% de las participantes informó preferir las almohadillas de arena. Se concluyó que tanto las almohadillas de arena (apoyo isquiático) como la espuma cilíndrica (apoyo perineal) mejoraron la percepción y la facilitación de la contracción muscular del SP en posición sentada de mujeres con disfunción muscular del SP en comparación con la ausencia de la herramienta, sin embargo, hay no hubo diferencia entre las herramientas.

4.
Physiotherapy ; 105(3): 321-327, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30342701

RESUMO

OBJECTIVES: To compare the functional status at intensive care unit (ICU) discharge of patients who were later readmitted to the ICU and patients discharged home and to verify whether a decline in functional status is associated with ICU readmission. DESIGN: Prospective cohort study. SETTING: ICU at a tertiary teaching hospital. PARTICIPANTS: Patients admitted to the ICU, ≥18 years old, submitted to invasive mechanical ventilation (IMV), and discharged to the ward. INTERVENTIONS: Functional assessment at ICU discharge. Discharge Group (DG) (patients discharged home) and Readmission Group (RG) (patients who returned to the ICU) were compared with Mann-Whitney and Chi-square or Exact Fisher tests. Multiple logistic regression verified association. MAIN OUTCOME MEASURES: Barthel Index, key pinch strength, clinical and demographic data. RESULTS: Patients in the readmission group presented lower Barthel Index [Median 40 (IQR 20-75) vs 60 (33-83), P=0.033], greater relative variation (pre and post ICU) of the Barthel Index (P=0.04), lower key pinch strength [3.4 (1.8-4.5) vs 4.5 (2.7-6.8)kg·f, P=0.006] and higher APACHE II [18 (12-22) vs 15 (11-20), P=0.027]. Multiple regression found that the relative variation of the Barthel Index was independently associated with ICU readmission (P<0.001), as well as higher APACHE II (P=0.020), shorter IMV duration (P<0.001) and ICU admission without clear diagnosis (P=0.020). The Hosmer-Lemeshow test indicated good adjustment of the model (P=0.99). CONCLUSION: Readmitted patients presented poorer functional status and lower pinch strength. Relative variation of the Barthel Index was associated with ICU readmission despite other factors, as was higher APACHE II, shorter IMV duration and admission without clear diagnosis. TRIAL REGISTRATION NUMBER: Not applicable.


Assuntos
Unidades de Terapia Intensiva/estatística & dados numéricos , Alta do Paciente/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Desempenho Físico Funcional , Respiração Artificial , APACHE , Adulto , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Força de Pinça , Estudos Prospectivos , Centros de Atenção Terciária
5.
Int J Qual Health Care ; 30(4): 265-270, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29385454

RESUMO

OBJECTIVE: To assess the functional status of post-ICU patients using the Barthel Index (BI) and the Katz Index (KI) and to assess which is more suitable for this population. DESIGN: Retrospective longitudinal study. SETTING: Public tertiary hospital in São Paulo (Brazil). PARTICIPANTS: Patients aged ≥18 years old, admitted to ICU, who were treated with mechanical ventilation (MV) ≥ 24 h and were discharged to ward. EXCLUSION CRITERIA: Inability to answer the BI and the KI; limiting neurological or orthopaedic conditions; ICU stay ≥90 days. Patients transferred to or from other hospitals or who died in the wards were not analysed. INTERVENTION: BI and KI were scored pre-ICU and post-ICU and the variation was calculated. MAIN OUTCOME MEASURES: BI and KI scores were compared using analysis based on item response theory (IRT), using degree of difficulty and discriminating items as parameters. RESULTS: Median age was 52 years old, median APACHE II score was 15. Median ICU stay was 11 days and median MV duration was 4 days. BI variation was 44% and KI variation was 55%. In IRT analysis, BI considered a larger number of items with different levels of difficulty. CONCLUSION: Both the BI and the KI revealed significant deterioration of functional status after ICU discharge. The IRT analysis suggested that the Barthel Index might be a better scale than the Katz Index for the assessment of functional status of patients discharged from ICU, since it presented better discrimination of the ability to carry out the tasks.


Assuntos
Atividades Cotidianas , Unidades de Terapia Intensiva/estatística & dados numéricos , Respiração Artificial , Adulto , Brasil , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção Terciária
8.
Rev. bras. ter. intensiva ; 27(3): 252-259, jul.-set. 2015. tab, ilus
Artigo em Português | LILACS | ID: lil-761666

RESUMO

RESUMOObjetivo:Descrever o uso de ventilação não invasiva com pressão positiva pós-extubação na prática clínica da unidade de terapia intensiva, e identificar os fatores associados à falência da ventilação não invasiva com pressão positiva.Métodos:Este estudo prospectivo de coorte incluiu pacientes com idade ≥ 18 anos admitidos consecutivamente à unidade de terapia intensiva e submetidos à ventilação não invasiva com pressão positiva dentro de 48 horas após sua extubação. O desfecho primário foi falência da ventilação não invasiva com pressão positiva.Resultados:Incluímos um total de 174 pacientes. A taxa global de uso de ventilação não invasiva com pressão positiva foi de 15%. Dentre todos os pacientes que utilizaram ventilação não invasiva com pressão positiva, em 44% o uso ocorreu pós-extubação. A taxa de falência da ventilação não invasiva com pressão positiva foi de 34%. A média de idade (± DP) foi de 56 ± 18 anos, sendo que 55% dos pacientes eram do sexo masculino. Os dados demográficos, níveis basais de pH, PaCO2 e HCO3 além do tipo de equipamento utilizado foram similares entre os grupos. Todos os parâmetros finais de ventilação não invasiva com pressão positiva foram mais elevados no grupo que apresentou falência da ventilação não invasiva com pressão positiva (pressão inspiratória positiva nas vias aéreas - 15,0 versus 13,7cmH2O; p = 0,015; pressão expiratória positiva nas vias aéreas - 10,0 versus8,9cmH2O; p = 0,027; e FiO2 - 41 versus33%; p = 0,014). O grupo que teve falência da ventilação não invasiva com pressão positiva teve tempo médio de permanência na unidade de terapia intensiva maior (24 versus 13 dias; p < 0,001), e taxa de mortalidade na unidade de terapia intensiva mais elevada (55 versus 10%; p < 0,001). Após adequação, o modelo de regressão logística permitiu afirmar que pacientes com pressão inspiratória positiva nas vias aéreas ≥ 13,5cmH2O no último dia de suporte com ventilação não invasiva com pressão positiva tiveram risco três vezes maior de se tornarem casos de falência da ventilação não invasiva com pressão positiva, do que os pacientes que tiveram pressão inspiratória positiva das vias aéreas < 13,5 (OR = 3,02; IC95% = 1,01 - 10,52; p = 0,040).Conclusão:O grupo com falência da ventilação não invasiva com pressão positiva teve tempo de permanência na unidade de terapia intensiva maior, além de uma taxa de mortalidade mais elevada. A análise de regressão logística identificou que pacientes com pressão inspiratória positiva nas vias aéreas ≥ 13,5cmH2O no último dia de suporte ventilatório não invasivo tiveram risco três vezes maior de apresentar falência da ventilação não invasiva com pressão positiva.


ABSTRACTObjective:To describe postextubation noninvasive positive pressure ventilation use in intensive care unit clinical practice and to identify factors associated with noninvasive positive pressure ventilation failure.Methods:This prospective cohort study included patients aged ≥ 18 years consecutively admitted to the intensive care unit who required noninvasive positive pressure ventilation within 48 hours of extubation. The primary outcome was noninvasive positive pressure ventilation failure.Results:We included 174 patients in the study. The overall noninvasive positive pressure ventilation use rate was 15%. Among the patients who used noninvasive positive pressure ventilation, 44% used it after extubation. The failure rate of noninvasive positive pressure ventilation was 34%. The overall mean ± SD age was 56 ± 18 years, and 55% of participants were male. Demographics; baseline pH, PaCO2 and HCO3; and type of equipment used were similar between groups. All of the noninvasive positive pressure ventilation final parameters were higher in the noninvasive positive pressure ventilation failure group [inspiratory positive airway pressure: 15.0 versus 13.7cmH2O (p = 0.015), expiratory positive airway pressure: 10.0 versus 8.9cmH2O (p = 0.027), and FiO2: 41 versus 33% (p = 0.014)]. The mean intensive care unit length of stay was longer (24 versus 13 days), p < 0.001, and the intensive care unit mortality rate was higher (55 versus 10%), p < 0.001 in the noninvasive positive pressure ventilation failure group. After fitting, the logistic regression model allowed us to state that patients with inspiratory positive airway pressure ≥ 13.5cmH2O on the last day of noninvasive positive pressure ventilation support are three times more likely to experience noninvasive positive pressure ventilation failure compared with individuals with inspiratory positive airway pressure < 13.5 (OR = 3.02, 95%CI = 1.01 - 10.52, p value = 0.040).Conclusion:The noninvasive positive pressure ventilation failure group had a longer intensive care unit length of stay and a higher mortality rate. Logistic regression analysis identified that patients with inspiratory positive airway pressure ≥ 13.5cmH2O on the last day of noninvasive positive pressure ventilation support are three times more likely to experience noninvasive positive pressure ventilation failure.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Extubação , Unidades de Terapia Intensiva , Ventilação não Invasiva/métodos , Respiração com Pressão Positiva/métodos , Estudos de Coortes , Tempo de Internação , Modelos Logísticos , Estudos Prospectivos , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...