Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1204(2): 157-70, 2008 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-18565533

RESUMO

The developments in capillary isoelectric focusing (cIEF) over the period 2003-2007 are reviewed. With the focus on technological aspects, cIEF papers published in the fields of methodology, new techniques, detection, multidimensional systems, miniaturization and applications are summarized. The methodology section covers recent research in ampholytes composition, detergents and other additives, carrier ampholyte free cIEF, coatings and other capillary modifications. In the section on new systems adjustments to the technique (e.g. dynamic IEF), different applications of cIEF (e.g. as injection system) and new devices are reported. Systems focusing on whole column imaging, fluorescence and chemiluminescence detection and coupling to mass spectrometers are discussed in the section on detection. Interfacing cIEF with MS via RPLC systems and hyphenation of cIEF with capillary electrochromatography and other capillary electrophoresis modes are also summarized. Papers focusing on miniaturization are reviewed in the section on microfluidic devices. The section on applications will show analysis of biopharmaceutical compounds and isolated proteins for metabolomic studies. For the analysis of complex biological matrices, generally multidimensional systems are needed, which are mentioned throughout this review.


Assuntos
Eletroforese Capilar/métodos , Focalização Isoelétrica/métodos , Animais , Eletroforese Capilar/instrumentação , Eletroforese Capilar/tendências , Humanos , Focalização Isoelétrica/instrumentação , Focalização Isoelétrica/tendências , Técnicas Analíticas Microfluídicas
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 839(1-2): 68-73, 2006 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-16600700

RESUMO

This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100 mM NaCl. However, ITP-CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE-CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.


Assuntos
Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Proteínas/química , Proteínas/isolamento & purificação , Animais , Humanos , Sistemas On-Line
3.
Rapid Commun Mass Spectrom ; 19(24): 3673-80, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16287039

RESUMO

Fludarabine and cyclophosphamide are anticancer agents mainly used in the treatment of hematologic malignancies. We have developed and validated an assay using high-performance liquid chromatography (HPLC) coupled with electrospray ionization tandem mass spectrometry for the quantification of fludarabine in combination with cyclophosphamide in human heparin and human EDTA plasma. Sample pre-treatment consisted of a protein precipitation with cold acetonitrile (-20 degrees C) using 250 microL of plasma. Separation was performed on an Extend C18 column (150 x 2.1 mm i.d.; 5 microm) with a stepwise gradient using 1 mM ammonia solution and acetonitrile at a flow rate of 400 microL/min. The analytical run time was 12 min. The triple quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over a concentration range of 1 to 100 ng/mL for fludarabine and cyclophosphamide in human heparin and human EDTA plasma. The coefficients of variation were <13.9% for inter- and intra-day precisions. Mean accuracies were also within the designated limits (+/-15%). The analytes were stable in plasma, processed extracts and in stock solution under all relevant conditions.


Assuntos
Antineoplásicos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Ciclofosfamida/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Vidarabina/análogos & derivados , Cladribina/sangue , Ciclofosfamida/análogos & derivados , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vidarabina/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA