Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Animals (Basel) ; 13(20)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37894017

RESUMO

This study endeavors to ascertain alterations in the in-line registered milk fat-to-protein ratio as a potential indicator for evaluating the metabolic status of dairy cows. Over the study period, farm visits occurred biweekly on consistent days, during which milk composition (specifically fat and protein) was measured using a BROLIS HerdLine in-line milk analyzer (Brolis Sensor Technology, Vilnius, Lithuania). Clinical examinations were performed at the same time as the farm visits. Blood was drawn into anticoagulant-free evacuated tubes to measure the activities of GGT and AST and albumin concentrations. NEFA levels were assessed using a wet chemistry analyzer. Using the MediSense and FreeStyle Optium H systems, blood samples from the ear were used to measure the levels of BHBA and glucose in plasma. Daily blood samples were collected for BHBA concentration assessment. All samples were procured during the clinical evaluations. The cows were categorized into distinct groups: subclinical ketosis (SCK; n = 62), exhibiting elevated milk F/P ratios without concurrent clinical signs of other post-calving diseases; subclinical acidosis (SCA; n = 14), characterized by low F/P ratios (<1.2), severe diarrhea, and nondigestive food remnants in feces, while being free of other post-calving ailments; and a healthy group (H; n = 20), comprising cows with no clinical indications of illness and an average milk F/P ratio of 1.2. The milk fat-to-protein ratios were notably higher in SCK cows, averaging 1.66 (±0.29; p < 0.01), compared to SCA cows (0.93 ± 0.1; p < 0.01) and healthy cows (1.22). A 36% increase in milk fat-to-protein ratio was observed in SCK cows, while SCA cows displayed a 23.77% decrease. Significant differences emerged in AST activity, with SCA cows presenting a 26.66% elevation (p < 0.05) compared to healthy cows. Moreover, SCK cows exhibited a 40.38% higher NEFA concentration (p < 0.001). A positive correlation was identified between blood BHBA and NEFA levels (r = 0.321, p < 0.01), as well as a negative association between BHBA and glucose concentrations (r = -0.330, p < 0.01). Notably, AST displayed a robust positive correlation with GGT (r = 0.623, p < 0.01). In light of these findings, this study posits that milk fat-to-protein ratio comparisons could serve as a non-invasive indicator of metabolic health in cows. The connections between milk characteristics and blood biochemical markers of lipolysis and ketogenesis suggest that these markers can be used to check the metabolic status of dairy cows on a regular basis.

2.
Biomed Opt Express ; 9(10): 4834-4849, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30319906

RESUMO

The infrared spectral region beyond 1.7 µm is of utmost interest for biomedical applications due to strong overtone and combination absorption bands in a variety of important biomolecules such as lactates, urea, glucose, albumin, etc. In this article, we report on recent progress in widely tunable swept-wavelength lasers based on type-I GaSb gain-chip technology, setting a new state-of-the-art in the 1.7 - 2.5 µm range laser sources. We provide an application example for the spectroscopic sensing of several biomolecules in a cuvette as well as an experimental demonstration of a non-invasive in-vivo sensing of human serum albumin through the skin.

3.
Sensors (Basel) ; 17(8)2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28777291

RESUMO

The availability of silicon photonic integrated circuits (ICs) in the 2-4 µm wavelength range enables miniature optical sensors for trace gas and bio-molecule detection. In this paper, we review our recent work on III-V-on-silicon waveguide circuits for spectroscopic sensing in this wavelength range. We first present results on the heterogeneous integration of 2.3 µm wavelength III-V laser sources and photodetectors on silicon photonic ICs for fully integrated optical sensors. Then a compact 2 µm wavelength widely tunable external cavity laser using a silicon photonic IC for the wavelength selective feedback is shown. High-performance silicon arrayed waveguide grating spectrometers are also presented. Further we show an on-chip photothermal transducer using a suspended silicon-on-insulator microring resonator used for mid-infrared photothermal spectroscopy.

4.
Opt Express ; 24(25): 28977-28986, 2016 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-27958562

RESUMO

2.0x µm widely tunable external cavity lasers realized by combining a GaSb gain chip with a silicon photonics waveguide circuit for wavelength selection are demonstrated. Wavelength tuning over 58 nm from 2.01 to 2.07 µm is demonstrated. In the silicon photonic integrated circuit, laser feedback is realized by using a silicon Bragg grating and continuous tuning is realized by using two thermally tuned silicon microring resonators (MRRs) and a phase section. The uncooled laser has maximum output power of 7.5 mW and threshold current density of 0.8 kA/cm2. The effect of the coupling gap of the MRRs on tunable laser performance is experimentally assessed. A side mode suppression ratio better than 52 dB over the full tuning range and in the optimum operation point of more than 60 dB is achieved for the laser with weakly coupled MRRs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...