Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
2.
Indian J Orthop ; 58(2): 182-189, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38312903

RESUMO

Introduction: Orthopaedic surgeons are among the most frequent users of radiation and are often exposed to X-Ray radiation regularly. There is an overall unsatisfactory level of knowledge, attitude, and practices regarding the same among surgeons. This study aimed to assess the practices among orthopaedic surgeons regarding radiation and its hazards in India. Methodology: This questionnaire-based survey was conducted between March and September 2022. The questionnaire broadly assessed the knowledge, awareness, and practices among orthopaedic surgeons regularly exposed to X-ray radiation. The questionnaire consisted of objective and Likert scale questions which were distributed to the respondents electronically using publicly available contact information. A qualitative review of interpretations obtained from the responses and available evidence in the literature was then performed. Results: The response rate for the survey was 36.4%. 65.9% reported using trunk protection all the time during procedures. 57.1% of respondents reported not using thyroid protection during procedures. 92.3% reported not using protective goggles and 100% did not use appropriate gloves. 76.9% were not issued dosimeters, and only 5.5% of those who had been issued one wore it during radiation procedures. 58.2% reported having a dedicated employee to operate the machine. 86.8% of respondents did not have formal training and 81.3% were not aware of institutes offering formal training. Conclusion: There is very high compliance with the use of protection aprons among the respondents however, the use of other apparel like thyroid shields, protection goggles and gloves was poor. The awareness regarding radiation exposure was also poor as most respondents were not issued dosimeters, however, those issued with one were well aware of their exposure. It is imperative to prioritize both surgeons' and patients' safety where radiation exposure is concerned.

3.
Cureus ; 15(9): e46070, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37900479

RESUMO

We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was done on an outpatient basis. At one year follow-up, the patient had good clinical and radiological outcomes. The K-wire-based external fixator frame is an effective fixation method for distal femur physeal slips in older children, providing favorable radiological and functional outcomes.

4.
Sci Rep ; 13(1): 16714, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37794099

RESUMO

To accommodate the ever-growing data requirements in densely populated areas and address the need for high-resolution sensing in diverse next-generation applications, there is a noticeable trend towards utilizing large unallocated frequency bands above 100 GHz. To overcome the harsh propagation conditions, large-scale antenna arrays are crucial and urge the need for cost-effective, mass-manufacturable technologies. A dedicated Any-Layer High Density Interconnect PCB technology for highly efficient wireless D-band (110-170 GHz) systems is proposed. Specifically, the adapted stack accommodates broadband air-filled substrate-integrated-waveguide components for efficient long-range signal distribution and low-loss passives. The viability of the suggested technology platform is demonstrated by designing, fabricating and measuring several essential low-loss air-filled substrate-integrated-waveguide components, such as a dual rectangular filter, with a minimal insertion loss of 0.87 dB and 10 dB-matching within the (132.8-139.2 GHz) frequency band, and an air-filled waveguide with a routing loss of only 0.08 dB/mm and a flat amplitude variation within 0.01 dB/mm over the (115-155 GHz) frequency range. A broadband transition towards stripline, with a limited loss of 1.1 dB, is described to interface these waveguides with compactly integrated chips. A tolerance analysis is included as well as a comparison to the state of the art.

5.
Indian J Orthop ; 57(8): 1226-1238, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37525733

RESUMO

Purpose: The orthopaedic surgeons, especially the young budding surgeons should have a well-balanced knowledge of the past evidence as well the current evidence in the literature for the appropriate as well as optimum management of tibial plateau fractures. Bibliometric analysis of the top-cited papers on tibial plateau fracture management can help know their concurrent interests, deficiencies and conflicting issues regarding their management. This study aimed to identify the 50 most cited research articles in tibial plateau research and analyse their characteristics. Methods: We searched the Thompson Reuters Web of Science database for articles relevant to tibial plateau fracture and prepared a list of top 50 cited articles that included original articles and review articles concerning tibial plateau fractures. The included articles were analysed for contributing journals, corresponding author's country, publication year, cumulative citations, annual citations, citation trends over time, level of evidence and a qualitative review. Results: The search strategy resulted in 2263 articles. The top 50 cited articles were published from 1974 to 2014 and belonged to 12 journal sources. There were 47 original articles and 3 review articles. The average citations per article were 126.2, and the annual citations per article were 6.478 per year. The top-cited articles were relevant to the strategies in the management, classification, fracture reduction, articular restoration, types and number of fixation devices, surgical approaches, associated menisco-ligamentous injuries and applicability of bone grafts/substitutes in tibial plateau fractures. Conclusion: The current bibliometric analysis summarises the top-cited evidence concerning tibial plateau fractures and can be a potential resource for reviewing and locating the same. The analysis shows that most top-cited evidence belongs to the year 2000 onwards. Also, recent articles have a higher annual citation rate. A limited number of journals and mostly, western countries have contributed to the top-cited evidence. Whilst the top-cited evidence has touched several aspects of tibial plateau fractures, it is in the form of level IV case series. It needs better prospective evidence to establish sound recommendations. Supplementary Information: The online version contains supplementary material available at 10.1007/s43465-023-00932-4.

6.
J Orthop Case Rep ; 13(1): 1-4, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37143553

RESUMO

Introduction: Chondrosarcoma of rib encroaching spine and subsequently leading to paraplegia has never been reported in the literature. Association of paraplegia can often lead to misdiagnosis with a common disease like breast cancer or Potts spine causing a significant delay in treatment. Case Report: We describe a case of a 45-year-old male with chondrosarcoma of rib with paraplegia who was misdiagnosed initially as Pott's spine and was started empirically on anti-tubercular treatment for paraplegia and chest wall mass. Further work up at tertiary care center including detailed imaging and biopsy revealed features of chondrosarcoma. However, before any definitive treatment could be done; the patient passed away. Conclusion: Empirical treatment of paraplegia with chest wall mass for more common diseases like tuberculosis are often initiated without obtaining appropriate radiological and tissue diagnosis. This can lead to a delay in diagnosis and initiation of treatment.

7.
Indian J Orthop ; 57(6): 789-799, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37214369

RESUMO

Introduction: Lateral condyle fractures in children have been typically been treated operatively using Kirschner wires (K wire) or cannulated screws (CCS); however, a definitive choice of implant remains a matter of debate. This systematic review aims to determine if union and functional outcomes of these fractures are better with screw fixation. Methodology: A search of PubMed, Medline, Cochrane, and Google scholar was performed in March 2021. The results were screened by title and abstract, and relevance and a quality assessment of the data were performed for the articles meeting the inclusion criteria. Articles comparing radiological and functional outcomes of lateral condyle fractures treated with K wires or screws were included for examination. Articles were excluded if they did not compare outcomes of K wires and CCS together, or were in a language other than English, technical notes, case reports, and articles, which describe the use of fixation methods other than K wire or CCS as well as biomechanical studies were also excluded. Risk of bias and quality assessment of included articles were also done. Results: Seven clinical studies were included. 44.4% (n = 4) were retrospective review of records with level III evidence (77.7%, n = 7). Only two included articles had good-quality assessment scores. Union was reported in 85.7% % in K wire group and 99.6% in CCS group. Functional outcomes were not statistically significant between the two groups. Conclusion: Using screws to fix lateral condyle provides better union; however, there is no difference in the functional outcomes and complication rate between the two. Using screws or buried K wires adds the burden of an additional procedure for removal.

8.
Indian J Orthop ; 56(12): 2182-2192, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36507217

RESUMO

Purpose: Above-knee casts pose a major challenge in the day-to-day activities among walking age clubfoot patients due to complete restriction of knee movement. This current study investigates the effectiveness of below-knee casts compared to above-knee casts for managing walking age clubfoot deformity. Methods: After approval from the institutional ethical committee, we enrolled walking age clubfoot patients for deformity correction through corrective manipulation and casting through below-knee casts over 2 years. The corrective manipulation was performed using the Ponseti technique. The patients were followed for a minimum of 2 years period. To compare the effectiveness of below-knee casts over above-knee casts, we enrolled equal numbers of walking age clubfeet matched for age and gender. We compared the two groups in terms of initial and post-correction Dimeglio scores, individual deformities corrections (maximum ankle dorsiflexion, heel varus correction, foot abduction), failure rates, relapses, and complication rates. Results: 56 patients with 80 clubfeet with a mean follow-up of 39.98 months were considered for the final analysis. There were 29 patients in the below-knee cast group and 27 in the above-knee cast group, with 40 clubfeet each. The patients in the above-knee casting group had significantly better post-correction Dimeglio scores and individual deformity components corrections than the below-knee cast group. There were nil failures in the above-knee casting group and 7.5% in the below-knee cast group. The relapse rate was 15% in both groups, with none requiring any extensive soft tissue procedure. We did not encounter any major complications during the treatment and follow-up. Conclusion: The deformity correction and maintenance are suboptimal with the below-knee casts. Therefore, above-knee casts should be the preferred management modality for correction of walking age clubfoot deformities.

9.
Indian J Orthop ; 56(12): 2202-2209, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36189122

RESUMO

Introduction: Telemedicine has been evolving over the last two decades; however, with the advent of the COVID 19 pandemic, its utility and acceptance have drastically increased. Most studies report increasing acceptability and satisfaction rates. This study aimed to assess patient preferences regarding telemedicine to in-person consultations and to attempt to assess the factors driving these preferences. Material and Methods: A questionnaire-based cross-sectional study was conducted for patients who had both teleconsultation and in-person consultation in the orthopedic outpatient. After obtaining consent to participate in the study, the patients were divided into broad clinical categories and responses were recorded regarding the treatment of illness by the doctor and opinions regarding telemedicine. Most questions were in yes/no or a Likert-based questionnaire. Mean, median, percentage and proportions were used for statistical analysis of the data. Results: The study group included 264 patients, with the majority with fractures and dislocations. Most patients (55.7%) were comfortable using the software for teleconsultation, and half the respondents found telemedicine convenient. A large percentage of the study group preferred in-person consultation to teleconsultation (58.7%), and the primary reasons for discontinuing teleconsultation were dissatisfaction during the interaction with the doctor and poor connectivity to telecommunication networks. Conclusion: Telecommunication has high acceptance and satisfaction, but many factors limit its acceptance in developing countries.

10.
Indian J Orthop ; 56(6): 1011-1017, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35669027

RESUMO

Introduction: Post-traumatic blister is often encountered in high-energy injuries and following major limb surgeries. Currently, there is very limited evidence concerning blister management resulting in a lack of comprehensive guidelines for their management. The current survey-based study aims to appraise the current consensus in post-traumatic management among the practising orthopaedic surgeons and compare the same with the evidence in the literature. Materials and Methods: We conducted an online questionnaire-based survey of orthopaedic surgeons concerning post-traumatic blister management practices. The questionnaire mainly focused on antibiotic prophylaxis, local invasive procedures, antiseptics dressings and additional treatment options regarding blister management. Results: A high prevalence (~ 78%) of systemic antibiotics administration was noticed for post-traumatic blister management. Similarly, large section of respondents (66.4%) advocated for either de-roofing or aspiration of blisters. Approximately 42% of respondents preferred sending blister fluid for cultures. More than half of the respondents used some form of local dressing to cover the blister bed to provide a healing environment. Additional opinions mostly included anti-inflammatory and swelling reducing measures. Few respondents also advocated for oral steroids for inflammation control. Conclusion: The limited evidence available in literature could be the potential contributing factor for varying clinical practices for post-traumatic blister management. The general measures to reduce soft-tissue oedema have been supported by the literature. However, the use of systemic antibiotics and steroids has not been supported by the literature and should be avoided unless indicated due to other reasons. Further evidence is required to strengthen the recommendations for post-traumatic blister management.

11.
Cureus ; 14(4): e24408, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35619872

RESUMO

Introduction Calcium-sulfate-hydroxyapatite bioceramics have been widely used as void fillers in bone. However, their effectiveness as void fillers in core decompression for osteonecrosis of the femoral head (ONFH) in preventing femoral head collapse prevention has limited evidence. The current study investigates the effectiveness of calcium-sulfate-hydroxyapatite bioceramics as a void filler in the core decompression procedure for ONFH. Methods We retrospectively reviewed the clinical and radiological records of ONFH patients that underwent core-decompression using either autologous iliac crest cancellous bone graft or calcium-sulfate-hydroxyapatite bioceramic paste as void fillers with at least one-year follow-up. The primary outcome of this study was the radiological progression of collapse in the last available standard anteroposterior (AP) radiographs of the hip. The collapse progression was compared between the two groups based on void fillers. Results This study included patient records with 44 hip joints that underwent core decompression. There were five female and 33 male patients. The mean age was 29.1±6.3 years. The mean follow-up duration was 21.4±3.4 months. No significant differences in collapse progression were observed between the two groups based on void fillers. Conclusion The use of calcium-sulfate-hydroxyapatite as a void filler in core decompress for ONFH is not superior to the autologous cancellous bone in terms of collapse prevention and mechanical support. Further modifications in the core decompression techniques and well-planned prospective studies would help establish sound recommendations.

12.
Indian J Orthop ; 56(5): 785-796, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35547349

RESUMO

Purpose: The knowledge regarding meniscus has vastly evolved over the past few decades. The meniscus's intact, injured, and repaired status can affect other joint structures, i.e., ligaments, articular surfaces, and overall biomechanics of the knee joint. Due to available evidence's extensiveness, it is challenging to determine the most influential topics and the emerging trends in concurrent meniscus research. This study aims to identify the top fifty cited papers in meniscus research and concurrent knee issues and analyse their characteristics. Methods: A comprehensive search was conducted on the Thompson Reuters Web of Science database to prepare a list of top fifty cited articles that included original articles and review articles concerning meniscus. The included articles were analysed for the source journal, investigating institution, country of the corresponding author, year of publication, total citations, annual citation rate, and a qualitative review. Results: The search strategy resulted in 6768 original articles and 453 review articles. The top fifty cited articles were published from 1969 to 2014 and belonged to 14 journal sources. There were 43 original articles and seven review articles. The average citations per article were 417.4 and the average citations per paper per year were 22.6. Besides the meniscus, a general interest in the clinical assessment scores, anterior cruciate ligament, long-term osteoarthritis, and cartilage was observed. Conclusion: Most of the research concerning meniscus relates to the importance of meniscus preservation, the link between meniscus injuries and concomitant anterior cruciate ligament and chondral injuries, and its role in long-term gonarthrosis. The western countries have contributed the maximum to the top-cited evidence concerning meniscus. The meniscus repair and transplantation techniques have recently gained importance and need further research to qualify for the top-cited evidence.

13.
Indian J Orthop ; 56(3): 369-376, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35251499

RESUMO

PURPOSE: To compare functional and radiological outcomes of transverse patella fractures treated with tension band wiring using either two 4.5 mm cannulated screws or Kirshner wire. METHODS: This is a non-blinded prospective randomized study comprising of two groups (n = 30 each) with closed transverse patella fractures treated with tension band wiring using Kirschner wire (K wire group) and two 4.5 mm cannulated screws (CCS group). Outcomes measured were radiological union, Knee Society score, range of motion and post-operative complications. RESULTS: The CCS group showed a statistically significant higher range of motion than K wire group for each follow up (p < 0.001 in flexion and p < 0.005 in extension). A statistically significant higher percentage of patients in the CCS group showed signs of union at 6th and 12th post-operative week (p = 0.001 and 0.011 respectively) but no difference at 24th post-operative week (p = 0.313). The rate of hardware complications was significantly higher in K wire group (p = 0.001). No significant difference was noted in in the Knee society score and post-operative complications between the groups. CONCLUSION: This study concludes that the fixation of closed transverse patella fractures using two 4.5 mm cannulated screws is allows a faster rate of union, a better knee range of motion and lesser hardware complications as compared to Kirschner wires. However more studies with larger sample sizes and longer follow up are required.

14.
J Orthop Case Rep ; 12(10): 44-49, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36874894

RESUMO

Introduction: Pubic symphysis osteomyelitis is a rare complication of hernia repair, it is easily mistaken for osteitis pubis (OP) which can lead to a significant delay in diagnosis and prolonged pain for the patient. Case Report: We present the case of a 41-year-old male who presented with complaints of diffuse low back pain, perineal pain for 8 weeks after bilateral laparoscopic hernia repair. The patient was initially considered to have OP and managed however pain did not relieve with treatment. There was tenderness in the ischial tuberosity only. At the time of presentation, X-ray revealed areas of erosion and sclerosis in the pubis with increased inflammatory markers. Magnetic resonance imaging showed an altered marrow signal in the pubic symphysis, edema in the gluteus maximus on the right side, and collection in the peri-vesical space. The patient was started on oral antibiotics for 6 weeks and clinicoradiological improvement was noted. Conclusion: Pubic osteomyelitis and OP show similar clinical presentations with contrasting treatments. Early identification and initiation of appropriate treatment can decrease morbidity and improve outcomes.

15.
J Taibah Univ Med Sci ; 17(2): 203-213, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34690642

RESUMO

OBJECTIVES: In the wake of recent widespread interest in telemedicine during the COVID-19 era, many orthopaedic surgeons may be unfamiliar with clinical examination skills, patients' safety, data security, and implementation-related concerns in telemedicine. We present a bibliometric analysis and review of the telemedicine-related publications concerning orthopaedics care during the COVID-19 pandemic. Such analysis can help orthopaedic surgeons become acquainted with the recent developments in telemedicine and its usage in regular orthopaedics practice. METHODS: We systematically searched the database of Thomson Reuters Web of Science for telemedicine-related articles in orthopaedics published during the COVID-19 pandemic. The selected articles were analysed for their source journals, corresponding authors, investigating institutions, countries of the corresponding authors, number of citations, study types, levels of evidence, and a qualitative review. RESULTS: Fifty-nine articles meeting the inclusion criteria were published in 28 journals. Three hundred forty-two authors contributed to these research papers. The United States (US) contributed the most number of articles to the telemedicine-related orthopaedics research during the COVID-19 era. All articles combined had a total of 383 citations and 66.1% were related to the Economic and Decision-making Analyses of telemedicine implementation. By and large, level IV evidence was predominant in our review. CONCLUSION: Telemedicine can satisfactorily cover a major proportion of patients' visits to outpatient departments, thus limiting hospitals' physical workload. Telemedicine has a potential future role in emergency orthopaedics and inpatient care through virtual aids. The issues related to patient privacy, data security, medicolegal, and reimbursement-related aspects need to be addressed through precise national or regional guidelines. Lastly, the orthopaedic physical examination is a weak link in telemedicine and needs to be strengthened.

16.
Injury ; 53(2): 569-575, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34602243

RESUMO

INTRODUCTION: Tip-apex-distance (TAD) has been widely advocated as the index to predict the risk of screw cut out in hip fractures treated with sliding hip screw devices. The fluoroscopic extents of the femoral head can change with the slightest change in the limb position which includes internal and external rotations, adduction and abduction. These changes can affect the visible TAD and articular-clearance of the screw-tip. The purpose of this Computed-tomography(CT) based analysis is to analyze the variations of the radiographically visible articular-clearance and TAD measurements with limb positioning and to determine the appropriate fluoroscopic projections for different screw-positions within the femoral head. MATERIAL AND METHODS: We retrospectively analysed CT studies of twenty healthy proximal femora. Spatial markers simulating screw tips were placed in the different combinations of anteroposterior(AP) and cephalocaudal(CC) positions. Software-based AP and lateral radiographs were developed for each screw position. Additional AP radiographs with femur in internal and external rotation, and lateral radiographs with the femur in adduction and abduction were developed. The variation of TAD and articular-clearance of the screw was measured among these radiographs for individual screw tip positions. RESULTS: Screw tip placed centrally in AP and CC planes position didn't show any significant variation in TAD and articular-clearance with modified AP and lateral radiographs. Significant differences were observed in TAD and articular-clearance values for other screw tip positions. Anteriorly placed screw tips had higher TAD and articular-clearance values with external rotation and similar changes were observed with posteriorly placed tips in internal rotation. Inferiorly placed tips had higher articular-clearance and TAD with limb abduction and similar changes were observed for superiorly placed tips with limb adduction. CONCLUSIONS: For the sliding screws placed in non-central locations, the clearance of the screw tip from the articular margins can not be appropriately estimated with conventional AP and lateral views. Additional views with the limb in internal rotation and external rotation in AP view, and adduction-abduction in lateral view are required to safely place the sliding screw in the femoral head. The limb should be brought to a neutral alignment for the accurate estimation of TAD.


Assuntos
Parafusos Ósseos , Fraturas do Quadril , Fluoroscopia , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
Cureus ; 14(12): e33121, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36721606

RESUMO

There has been emerging evidence supporting the mini-clinical evaluation exercise (mini-CEX) in various clinical specialties and settings. However, we need more clarity regarding the applicability of mini-CEX as an optimal assessment tool. Consequently, it has not been implemented on a wider scale, and several clinical specialties are yet to explore the benefits of mini-CEX. Therefore, we conducted a bibliometric analysis to investigate the publication trends of mini-CEX. We searched the Web of Science database for mini-CEX-related original and review articles. The search results were analyzed for year-wise contribution, citation trends, contributing journals, contributing institutions, countries, authors, distribution of original/review articles, retrospective/prospective/laboratory/other types of studies, specialties covered, nature of medical education (undergraduate vs. specialty trainees), and clinical settings involved in the studies (single/multiple). A total of 59 eligible articles (53 original and six review articles) were published between 1995 and 2022 in 35 different journals. The mean citations per year were 65.96 per year, and the mean citations per article per year were 2.34 citations per article per year. The articles published in BMC Medical Education and Medical Teacher were the highest in number. In total, 97 institutes contributed to the mini-CEX-related research, mostly from the University of Bern, Switzerland. There were 238 contributing authors, with Norcini JJ contributing the most number of articles. The remaining articles were 15 retrospective studies, one developmental study, six review articles, and three laboratory-based studies. The 50 non-laboratory studies involved students/trainees in medical and allied fields. Medicine was the most frequently covered specialty. The participants were mostly specialty trainees, followed by undergraduate medical students. Multiple settings were used in 38% of the reviewed studies and single in 16%. The published articles have reduced impact and growth, as evidenced by low annual growth rates and citation trends. However, the available evidence was of reasonable quality considering the contribution from mostly prospective studies. Furthermore, it suggests considerable potential for further investigating the role of mini-CEX in clinical teaching.

18.
Cureus ; 14(11): e32080, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36600811

RESUMO

INTRODUCTION: During the COVID-19 surge, due to a lack of operating room availability, we performed Achilles tendon tenotomy in clubfoot patients using a 16/18 gauge needle to avoid delay in their management. The procedures were performed on an outpatient basis. The current retrospective study aims to investigate the effectiveness of needle tenotomy for the correction of equinus in clubfoot at a minimum of one year of follow-up. METHODS: Clinical records of all clubfoot patients that underwent needle tenotomy of Achilles tendon from March 2020 onwards with at least one year of follow-up were reviewed. We recorded Pirani scores and the equinus deformity at the initial presentation, after Achilles tendon tenotomy, and at the final follow-up. We also recorded any procedure-related complications following the Achilles tendon tenotomy. We compared dorsiflexion after final cast removal and after one year of follow-up. RESULTS: A total of 26 clubfeet in 14 patients underwent needle tenotomy of the Achilles tendon and completed one year of follow-up. Ankle dorsiflexion was achievable in all patients and the mean dorsiflexion of 27.4 degrees. The average Pirani score after tenotomy at final cast removal was 0.16, while the mean dorsiflexion at final cast removal was 24.2 degrees (p = .00084). No tenotomy procedure-related complications were noted. CONCLUSION: Percutaneous needle tenotomy of the Achilles tendon is a simple, safe, and effective technique for equinus correction in clubfoot. Considering the less invasive nature of the procedure, it can be done as a short procedure on an outpatient basis and has a limited risk of hemorrhage and other wound-related complications.

19.
Orthop J Sports Med ; 9(11): 23259671211057851, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34881343

RESUMO

BACKGROUND: Limited attention has been paid to the natural history, management, and treatment outcomes related to the posterior cruciate ligament (PCL)-deficient knee joint. PURPOSE: To perform a comprehensive bibliometric analysis to evaluate the 50 top-cited articles in PCL research. STUDY DESIGN: Cross-sectional study. METHODS: We performed a keyword-based search in the Thomson Reuters Web of Science to generate a list of the 50 most cited articles relevant to the PCL. The included articles were analyzed according to journal, country of origin, publication year, total number of citations, citations per year, citation trends, and type of study (clinical vs basic science). RESULTS: The 50 top-cited articles were published between 1975 and 2012, and the number of individual article citations ranged between 98 and 410. The listed articles were published in 7 journals, with the American Journal of Sports Medicine contributing to more than half of the articles and citations. The United States contributed the most articles (84%) and citations (n = 4873). There were 32 clinical studies and 18 basic science studies. All clinical studies had level 4 clinical evidence, and topics included the natural history of PCL tears, factors predicting the need for surgical intervention, and long-term outcomes of isolated PCL injuries and combined capsuloligamentous injuries. Most (77.8%) of the top-cited basic science articles consisted of experimental or biomechanical studies on human cadaveric knees. CONCLUSION: The current analysis suggests that PCL research is still evolving and needs high-quality prospective evidence to establish sound recommendations.

20.
Cureus ; 13(9): e18285, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34722062

RESUMO

Introduction There is a lack of standardized objective tools to assess collapse for osteonecrosis of the femoral head (ONFH) patients' follow-up. We describe a quantitative technique of collapse assessment using a superimposed concentric circular ring matching the intact part of the femoral head in anteroposterior (AP) radiographs. Methods We retrospectively analyzed 30 normal femoral heads and 30 ONFH (15 pre-collapse,15 post-collapse) in anteroposterior hip radiographs. A best-fitting circle was superimposed on articular margins of the femoral head and the maximum width of the deficient zone of the femoral head (not matching the circle) was measured. The width (pW) was measured as percentage-width in proportion to the circle's diameter. The findings were compared among normal and ONFH radiographs. Intraclass correlation coefficients were calculated for intraobserver and interobserver reliability of the measurements. Results The mean femoral head deficiencies predicted by pW were 0.2±0.5% for normal hip, 2.8±1.1% for pre-collapse, and 8.9±3.8% for post-collapse radiographs. We observed significant differences in the measurements of pW among the control group, pre-collapse and post-collapse groups. Interobserver and intraobserver reliabilities for the measurements were high. Conclusion The described concentric circle technique is a simple and reliable method for objective assessment of subtle alterations in the sphericity of the femoral head and can be helpful for the radiographic follow-up of ONFH patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...