Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38707197

RESUMO

Prostate cancer ranks among the most prevalent types of cancer in males, prompting a demand for early detection and noninvasive diagnostic techniques. This paper explores the potential of ultrasound radiofrequency (RF) data to study different anatomic zones of the prostate. The study leverages RF data's capacity to capture nuanced acoustic information from clinical transducers. The research focuses on the peripheral zone due to its high susceptibility to cancer. The feasibility of utilizing RF data for classification is evaluated using ex-vivo whole prostate specimens from human patients. Ultrasound data, acquired using a phased array transducer, is processed, and correlated with B-mode images. A range filter is applied to highlight the peripheral zone's distinct features, observed in both RF data and 3D plots. Radiomic features were extracted from RF data to enhance tissue characterization and segmentation. The study demonstrated RF data's ability to differentiate tissue structures and emphasizes its potential for prostate tissue classification, addressing the current limitations of ultrasound imaging for prostate management. These findings advocate for the integration of RF data into ultrasound diagnostics, potentially transforming prostate cancer diagnosis and management in the future.

2.
ACS Sens ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787788

RESUMO

Oxygen levels in tissues and organs are crucial for their normal functioning, and approaches to monitor them non-invasively have wide biological and clinical applications. In this study, we developed a method of acoustically detecting oxygenation using contrast-enhanced ultrasound (CEUS) imaging. Our approach involved the use of specially designed hemoglobin-based microbubbles (HbMBs) that reversibly bind to oxygen and alter the state-dependent acoustic response. We confirmed that the bioactivity of hemoglobin remained intact after the microbubble shell was formed, and we did not observe any significant loss of heme. We conducted passive cavitation detection (PCD) experiments to confirm whether the acoustic properties of HbMBs vary based on the level of oxygen present. The experiments involved driving the HbMBs with a 1.1 MHz focused ultrasound transducer. Through the PCD data collected, we observed significant differences in the subharmonic and harmonic responses of the HbMBs when exposed to an oxygen-rich environment versus an oxygen-depleted one. We used a programmable ultrasound system to capture high-frame rate B mode videos of HbMBs in both oxy and deoxy conditions at the same time in a two-chambered flow phantom and observed that the mean pixel intensity of deoxygenated HbMB was greater than in the oxygenated state using B-mode imaging. Finally, we demonstrated that HbMBs can circulate in vivo and are detectable by a clinical ultrasound scanner. To summarize, our results indicate that CEUS imaging with HbMB has the potential to detect changes in tissue oxygenation and could be a valuable tool for clinical purposes in monitoring regional blood oxygen levels.

3.
Pharmaceutics ; 15(11)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-38004529

RESUMO

The use of drug-loaded microbubbles for targeted drug delivery, particularly in cancer treatment, has been extensively studied in recent years. However, the loading capacity of microbubbles has been limited due to their surface area. Typically, drug molecules are loaded on or within the shell, or drug-loaded nanoparticles are coated on the surfaces of microbubbles. To address this significant limitation, we have introduced a novel approach. For the first time, we employed a transmembrane ammonium sulfate and pH gradient to load doxorubicin in a crystallized form in the core of polymeric microcapsules. Subsequently, we created remotely loaded microbubbles (RLMBs) through the sublimation of the liquid core of the microcapsules. Remotely loaded microcapsules exhibited an 18-fold increase in drug payload compared with physically loaded microcapsules. Furthermore, we investigated the drug release of RLMBs when exposed to an ultrasound field. After 120 s, an impressive 82.4 ± 5.5% of the loaded doxorubicin was released, demonstrating the remarkable capability of remotely loaded microbubbles for on-demand drug release. This study is the first to report such microbubbles that enable rapid drug release from the core. This innovative technique holds great promise in enhancing drug loading capacity and advancing targeted drug delivery.

4.
Sci Rep ; 13(1): 14942, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37696978

RESUMO

In this work, we discuss the development of H.O.S.T., a novel hemoglobin microbubble-based electrochemical biosensor for label-free detection of Hydrogen peroxide (H2O2) towards oxidative stress and cancer diagnostic applications. The novelty of the constructed sensor lies in the use of a sonochemically prepared hemoglobin microbubble capture probe, which allowed for an extended dynamic range, lower detection limit, and enhanced resolution compared to the native hemoglobin based H2O2 biosensors. The size of the prepared particles Hemoglobin microbubbles was characterized using Coulter Counter analysis and was found to be 4.4 microns, and the morphology of these spherical microbubbles was shown using Brightfield microscopy. The binding chemistry of the sensor stack elements of HbMbs' and P.A.N.H.S. crosslinker was characterized using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy and UV-Vis Spectroscopy. The electrochemical biosensor calibration (R2 > 0.95) was done using Electrochemical Impedance Spectroscopy, Cyclic Voltammetry, and Square Wave Voltammetry. The electrochemical biosensor calibration (R2 > 0.95) was done using Electrochemical Impedance Spectroscopy, Cyclic Voltammetry, and Square Wave Voltammetry. The specificity of the sensor for H2O2 was analyzed using cross-reactivity studies using ascorbic acid and glucose as interferents (p < 0.0001 for the highest non-specific dose versus the lowest specific dose). The developed sensor showed good agreement in performance with a commercially available kit for H2O2 detection using Bland Altman Analysis (mean bias = 0.37 for E.I.S. and - 24.26 for CV). The diagnostic potential of the biosensor was further tested in cancerous (N.G.P.) and non-cancerous (H.E.K.) cell lysate for H2O2 detection (p = 0.0064 for E.I.S. and p = 0.0062 for CV). The Michaelis Menten constant calculated from the linear portion of the sensor was found to be [Formula: see text] of 19.44 µM indicating that our biosensor has a higher affinity to Hydrogen peroxide than other available enzymatic sensors, it is attributed to the unique design of the hemoglobin polymers in microbubble.


Assuntos
Peróxido de Hidrogênio , Microbolhas , Hemoglobinas , Estresse Oxidativo , Tecnologia
5.
Nat Commun ; 14(1): 4989, 2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37591837

RESUMO

The estrogen receptor (ER) designated ERα has actions in many cell and tissue types that impact glucose homeostasis. It is unknown if these include mechanisms in endothelial cells, which have the potential to influence relative obesity, and processes in adipose tissue and skeletal muscle that impact glucose control. Here we show that independent of impact on events in adipose tissue, endothelial ERα promotes glucose tolerance by enhancing endothelial insulin transport to skeletal muscle. Endothelial ERα-deficient male mice are glucose intolerant and insulin resistant, and in females the antidiabetogenic actions of estradiol (E2) are absent. The glucose dysregulation is due to impaired skeletal muscle glucose disposal that results from attenuated muscle insulin delivery. Endothelial ERα activation stimulates insulin transcytosis by skeletal muscle microvascular endothelial cells. Mechanistically this involves nuclear ERα-dependent upregulation of vesicular trafficking regulator sorting nexin 5 (SNX5) expression, and PI3 kinase activation that drives plasma membrane recruitment of SNX5. Thus, coupled nuclear and non-nuclear actions of ERα promote endothelial insulin transport to skeletal muscle to foster normal glucose homeostasis.


Assuntos
Receptor alfa de Estrogênio , Insulina , Animais , Feminino , Masculino , Camundongos , Células Endoteliais , Glucose , Músculo Esquelético , Receptores de Estrogênio
6.
Pharmaceutics ; 15(6)2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37376152

RESUMO

Despite recent advancements in ultrasound-mediated drug delivery and the remarkable success observed in pre-clinical studies, no delivery platform utilizing ultrasound contrast agents has yet received FDA approval. The sonoporation effect was a game-changing discovery with a promising future in clinical settings. Various clinical trials are underway to assess sonoporation's efficacy in treating solid tumors; however, there are disagreements on its applicability to the broader population due to long-term safety issues. In this review, we first discuss how acoustic targeting of drugs gained importance in cancer pharmaceutics. Then, we discuss ultrasound-targeting strategies that have been less explored yet hold a promising future. We aim to shed light on recent innovations in ultrasound-based drug delivery including newer designs of ultrasound-sensitive particles specifically tailored for pharmaceutical usage.

7.
Theranostics ; 13(10): 3402-3418, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37351172

RESUMO

Neuroblastoma (NB) is a pediatric malignancy that accounts for 15% of cancer-related childhood mortality. High-risk NB requires an aggressive chemoradiotherapy regimen that causes significant off-target toxicity. Despite this invasive treatment, many patients either relapse or do not respond adequately. Recent studies suggest that improving tumor perfusion can enhance drug accumulation and distribution within the tumor tissue, potentially augmenting treatment effects without inflicting systemic toxicity. Accordingly, methods that transiently increase tumor perfusion prior to treatment may help combat this disease. Here, we show the use of gene therapy to confer inducible nitric oxide synthase (iNOS) expression solely in the tumor space, using focused ultrasound targeting. NOS catalyzes the reaction that generates nitric oxide (NO), a potent endogenous vasodilator. This study reports the development of a targeted non-viral image-guided platform to deliver iNOS-expressing plasmid DNA (pDNA) to vascular endothelial cells encasing tumor blood vessels. Following transfection, longitudinal quantitative contrast-enhanced ultrasound (qCEUS) imaging revealed an increase in tumor perfusion over 72 h, attributed to elevated intratumoral iNOS expression. Methods: To construct a gene delivery vector, cationic ultrasound-responsive agents (known as "microbubbles") were employed to carry pDNA in circulation and transfect tumor vascular endothelial cells in vivo using focused ultrasound (FUS) energy. This was followed by liposomal doxorubicin (L-DOX) treatment. The post-transfection tumor response was monitored longitudinally using qCEUS imaging to determine relative changes in blood volumes and perfusion rates. After therapy, ex vivo analysis of tumors was performed to examine the bioeffects associated with iNOS expression. Results: By combining FUS therapy with cationic ultrasound contrast agents (UCAs), we achieved selective intratumoral transfection of pDNA encoding the iNOS enzyme. While transitory, the degree of expression was sufficient to induce significant increases in tumoral perfusion, to appreciably enhance the chemotherapeutic payload and to extend survival time in an orthotopic xenograft model. Conclusion: We have demonstrated the ability of a novel targeted non-viral gene therapy strategy to enhance tumor perfusion and improve L-DOX delivery to NB xenografts. While our results demonstrate that transiently increasing tumor perfusion improves liposome-encapsulated chemotherapeutic uptake and distribution, we expect that our iNOS gene delivery paradigm can also significantly improve radio and immunotherapies by increasing the delivery of radiosensitizers and immunomodulators, potentially improving upon current NB treatment without concomitant adverse effects. Our findings further suggest that qCEUS imaging can effectively monitor changes in tumor perfusion in vivo, allowing the identification of an ideal time-point to administer therapy.


Assuntos
Neuroblastoma , Óxido Nítrico , Criança , Humanos , Óxido Nítrico/metabolismo , Células Endoteliais/metabolismo , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Neuroblastoma/tratamento farmacológico , Óxido Nítrico Sintase Tipo II/genética , Óxido Nítrico Sintase Tipo II/metabolismo , DNA , Terapia Genética , Perfusão
8.
Artigo em Inglês | MEDLINE | ID: mdl-38495411

RESUMO

Ultrasound contrast agents (UCA) are gas-encapsulated microspheres that oscillate volumetrically when exposed to an ultrasound field producing backscattered signals efficiently, which can be used for improved ultrasound imaging and drug delivery applications. We developed a novel oxygen-sensitive hemoglobin-shell microbubble designed to acoustically detect blood oxygen levels. We hypothesize that structural change in hemoglobin caused due to varying oxygen levels in the body can lead to mechanical changes in the shell of the UCA. This can produce detectable changes in the acoustic response that can be used for measuring oxygen levels in the body. In this study, we have shown that oxygenated hemoglobin microbubbles can be differentiated from deoxygenated hemoglobin microbubbles using a 1D convolutional neural network using radiofrequency (RF) data. We were able to classify RF data from oxygenated and deoxygenated hemoglobin microbubbles into the two classes with a testing accuracy of 90.15%. The results suggest that oxygen content in hemoglobin affects the acoustical response and may be used for determining oxygen levels and thus could open many applications, including evaluating hypoxic regions in tumors and the brain, among other blood-oxygen-level-dependent imaging applications.

9.
ACS Appl Polym Mater ; 4(2): 773-780, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35187494

RESUMO

Polymeric microcapsules (MCs) are biocompatible agents used in biomedical applications such as drug delivery and in vivo imaging. We have discovered a method of remotely loading air into polylactic acid (PLA)-based MCs with an aqueous core. When the microcapsules are suspended in high content glycerol and propylene glycol solutions, changes in gas solubility cause bubbles to nucleate within the core through an "Ouzo-like" effect. The resulting bubble displaces the internal fluid of the MCs, but small molecules are retained in their interior. The residual content does not homogeneously distribute; rather, it localizes to one specific location, creating gas-filled Janus particles.

10.
Nano Lett ; 21(22): 9805-9815, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34516144

RESUMO

The blood-brain barrier (BBB) is highly selective and acts as the interface between the central nervous system and circulation. While the BBB is critical for maintaining brain homeostasis, it represents a formidable challenge for drug delivery. Here we synthesized gold nanoparticles (AuNPs) for targeting the tight junction specifically and demonstrated that transcranial picosecond laser stimulation of these AuNPs post intravenous injection increases the BBB permeability. The BBB permeability change can be graded by laser intensity, is entirely reversible, and involves increased paracellular diffusion. BBB modulation does not lead to significant disruption in the spontaneous vasomotion or the structure of the neurovascular unit. This strategy allows the entry of immunoglobulins and viral gene therapy vectors, as well as cargo-laden liposomes. We anticipate this nanotechnology to be useful for tissue regions that are accessible to light or fiberoptic application and to open new avenues for drug screening and therapeutic interventions in the central nervous system.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Transporte Biológico , Barreira Hematoencefálica , Ouro/química , Lasers
11.
J Vis Exp ; (169)2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33843933

RESUMO

There are many methods that can be used for the production of vaporizable phase-shift droplets for imaging and therapy. Each method utilizes different techniques and varies in price, materials, and purpose. Many of these fabrication methods result in polydisperse populations with non-uniform activation thresholds. Additionally, controlling the droplet sizes typically requires stable perfluorocarbon liquids with high activation thresholds that are not practical in vivo. Producing uniform droplet sizes using low-boiling point gases would be beneficial for in vivo imaging and therapy experiments. This article describes a simple and economical method for the formation of size-filtered lipid-stabilized phase-shift nanodroplets with low-boiling point decafluorobutane (DFB). A common method of generating lipid microbubbles is described, in addition to a novel method of condensing them with high-pressure extrusion in a single step. This method is designed to save time, maximize efficiency, and generate larger volumes of microbubble and nanodroplet solutions for a wide variety of applications using common laboratory equipment found in many biological laboratories.


Assuntos
Fluorocarbonos/química , Microbolhas/normas , Nanotecnologia/métodos
12.
Pharmaceutics ; 13(5)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33922219

RESUMO

Active targeted delivery of small molecule drugs is becoming increasingly important in personalized therapies, especially in cancer, brain disorders, and a wide variety of other diseases. However, effective means of spatial targeting and delivering high drug payloads in vivo are still lacking. Focused ultrasound combined with superheated phase-shift nanodroplets, which vaporize into microbubbles using heat and sound, are rapidly becoming a popular strategy for targeted drug delivery. Focused ultrasound can target deep tissue with excellent spatial precision and without using ionizing energy, thus can activate nanodroplets in circulation. One of the main limitations of this technology has been poor drug loading in the droplet core or the shell material. To address this need, we have developed a strategy to combine low-boiling point decafluorabutane and octafluoropropane (DFB and OFP) nanodroplets with drug-loaded liposomes, creating phase-changeable droplet-liposome clusters (PDLCs). We demonstrate a facile method of assembling submicron PDLCs with high drug-loading capacity on the droplet surface. Furthermore, we demonstrate that chemical tethering of liposomes in PDLCs enables a rapid release of their encapsulated cargo upon acoustic activation (>60% using OFP-based PDLCs). Rapid uncaging of small molecule drugs would make them immediately bioavailable in target tissue or promote better penetration in local tissue following intravascular release. PDLCs developed in this study can be used to deliver a wide variety of liposome-encapsulated therapeutics or imaging agents for multi-modal imaging applications. We also outline a strategy to deliver a surrogate encapsulated drug, fluorescein, to tumors in vivo using focused ultrasound energy and PDLCs.

13.
Nat Commun ; 11(1): 4929, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33004789

RESUMO

Non-invasive, molecularly-specific, focal modulation of brain circuits with low off-target effects can lead to breakthroughs in treatments of brain disorders. We systemically inject engineered ultrasound-controllable drug carriers and subsequently apply a novel two-component Aggregation and Uncaging Focused Ultrasound Sequence (AU-FUS) at the desired targets inside the brain. The first sequence aggregates drug carriers with millimeter-precision by orders of magnitude. The second sequence uncages the carrier's cargo locally to achieve high target specificity without compromising the blood-brain barrier (BBB). Upon release from the carriers, drugs locally cross the intact BBB. We show circuit-specific manipulation of sensory signaling in motor cortex in rats by locally concentrating and releasing a GABAA receptor agonist from ultrasound-controlled carriers. Our approach uses orders of magnitude (1300x) less drug than is otherwise required by systemic injection and requires very low ultrasound pressures (20-fold below FDA safety limits for diagnostic imaging). We show that the BBB remains intact using passive cavitation detection (PCD), MRI-contrast agents and, importantly, also by sensitive fluorescent dye extravasation and immunohistochemistry.


Assuntos
Barreira Hematoencefálica/metabolismo , Encefalopatias/tratamento farmacológico , Portadores de Fármacos/efeitos da radiação , Agonistas de Receptores de GABA-A/administração & dosagem , Ultrassonografia de Intervenção/métodos , Animais , Barreira Hematoencefálica/diagnóstico por imagem , Barreira Hematoencefálica/efeitos da radiação , Relação Dose-Resposta à Radiação , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Feminino , Agonistas de Receptores de GABA-A/farmacocinética , Humanos , Imageamento por Ressonância Magnética , Modelos Animais , Muscimol/administração & dosagem , Muscimol/farmacocinética , Ratos , Técnicas Estereotáxicas , Ondas Ultrassônicas
14.
Theranostics ; 10(18): 8143-8161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32724463

RESUMO

Neuroblastoma (NB) is the most common extracranial solid tumor in infants and children, and imposes significant morbidity and mortality in this population. The aggressive chemoradiotherapy required to treat high-risk NB results in survival of less than 50%, yet is associated with significant long-term adverse effects in survivors. Boosting efficacy and reducing morbidity are therefore key goals of treatment for affected children. We hypothesize that these may be achieved by developing strategies that both focus and limit toxic therapies to the region of the tumor. One such strategy is the use of targeted image-guided drug delivery (IGDD), which is growing in popularity in personalized therapy to simultaneously improve on-target drug deposition and assess drug pharmacodynamics in individual patients. IGDD strategies can utilize a variety of imaging modalities and methods of actively targeting pharmaceutical drugs, however in vivo imaging in combination with focused ultrasound is one of the most promising approaches already being deployed for clinical applications. Over the last two decades, IGDD using focused ultrasound with "microbubble" ultrasound contrast agents (UCAs) has been increasingly explored as a method of targeting a wide variety of diseases, including cancer. This technique, known as sonopermeation, mechanically augments vascular permeability, enabling increased penetration of drugs into target tissue. However, to date, methods of monitoring the vascular bioeffects of sonopermeation in vivo are lacking. UCAs are excellent vascular probes in contrast-enhanced ultrasound (CEUS) imaging, and are thus uniquely suited for monitoring the effects of sonopermeation in tumors. Methods: To monitor the therapeutic efficacy of sonopermeation in vivo, we developed a novel system using 2D and 3D quantitative contrast-enhanced ultrasound imaging (qCEUS). 3D tumor volume and contrast enhancement was used to evaluate changes in blood volume during sonopermeation. 2D qCEUS-derived time-intensity curves (TICs) were used to assess reperfusion rates following sonopermeation therapy. Intratumoral doxorubicin (and liposome) uptake in NB was evalauted ex vivo along with associated vascular changes. Results: In this study, we demonstrate that combining focused ultrasound therapy with UCAs can significantly enhance chemotherapeutic payload to NB in an orthotopic xenograft model, by improving delivery and tumoral uptake of long-circulating liposomal doxorubicin (L-DOX) nanoparticles. qCEUS imaging suggests that changes in flow rates are highly sensitive to sonopermeation and could be used to monitor the efficacy of treatment in vivo. Additionally, initial tumor perfusion may be a good predictor of drug uptake during sonopermeation. Following sonopermeation treatment, vascular biomarkers show increased permeability due to reduced pericyte coverage and rapid onset of doxorubicin-induced apoptosis of NB cells but without damage to blood vessels. Conclusion: Our results suggest that significant L-DOX uptake can occur by increasing tumor vascular permeability with microbubble sonopermeation without otherwise damaging the vasculature, as confirmed by in vivo qCEUS imaging and ex vivo analysis. The use of qCEUS imaging to monitor sonopermeation efficiency and predict drug uptake could potentially provide real-time feedback to clinicians for determining treatment efficacy in tumors, leading to better and more efficient personalized therapies. Finally, we demonstrate how the IGDD strategy outlined in this study could be implemented in human patients using a single case study.


Assuntos
Doxorrubicina/análogos & derivados , Microbolhas , Neuroblastoma/tratamento farmacológico , Imagem de Perfusão/métodos , Ultrassonografia de Intervenção/métodos , Animais , Apoptose/efeitos dos fármacos , Determinação do Volume Sanguíneo/instrumentação , Determinação do Volume Sanguíneo/métodos , Permeabilidade Capilar/efeitos da radiação , Linhagem Celular Tumoral , Meios de Contraste/administração & dosagem , Doxorrubicina/administração & dosagem , Doxorrubicina/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Estudos de Viabilidade , Humanos , Camundongos , Neuroblastoma/irrigação sanguínea , Neuroblastoma/diagnóstico por imagem , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/métodos , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacocinética , Estudos de Caso Único como Assunto , Ondas Ultrassônicas , Ultrassonografia de Intervenção/instrumentação , Ensaios Antitumorais Modelo de Xenoenxerto
15.
Langmuir ; 35(33): 10977-10986, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-31310715

RESUMO

The purpose of this study is to introduce a new concept of chemically cross-linked microbubble clusters (CCMCs), which are individual microbubble ultrasound contrast agents (UCAs) physically tethered together. We demonstrate a facile means of their production, characterize their size and stability, and describe how they can potentially be used in biomedical applications. By tethering UCAs together into CCMCs, we propose that novel methods of ultrasound mediated imaging and therapy can be developed through unique interbubble interactions in an ultrasound field. One of the major challenges in generating CCMCs is controlling aggregate sizes and maintaining stability against Ostwald ripening and coalescence. In this study, we demonstrate that chemically cross-linked microbubble clusters can produce small (<10 µm) quasi-stable complexes that slowly fuse into bubbles with individual gas cores. Furthermore, we demonstrate that this process can be driven with low-intensity ultrasound pulses, enabling a rapid fusion of clusters which could potentially be used to develop novel ultrasound contrast imaging and drug delivery strategies in future studies. The development of novel microbubble clusters presents a simple yet robust process for generating novel UCAs with a design that could allow for more versatility in contrast-enhanced ultrasound (CEUS), molecular imaging, and drug delivery applications. Additionally, microbubble clustering is a unique way to control size, shell, and gas compositions that can be used to study bubble ripening and coalescence in a highly controlled environment or study the behavior of mixed-microbubble populations.

16.
J Acoust Soc Am ; 145(6): 3457, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31255129

RESUMO

A phase-change contrast agent (PCCA) can be activated from a liquid (nanodroplet) state using pulsed ultrasound (US) energy to form a larger highly echogenic microbubble (MB). PCCA activation is dependent on the ambient pressure of the surrounding media, so any increase in hydrostatic pressure demands higher US energies to phase transition. In this paper, the authors explore this basic relationship as a potential direction for noninvasive pressure measurement and foundation of a unique technology the authors are developing termed tumor interstitial pressure estimation using ultrasound (TIPE-US). TIPE-US was developed using a programmable US research scanner. A custom scan sequence interleaved pulsed US transmissions for both PCCA activation and detection. An automated US pressure sweep was applied, and US images were acquired at each increment. Various hydrostatic pressures were applied to PCCA samples. Pressurized samples were imaged using the TIPE-US system. The activation threshold required to convert PCCA from the liquid to gaseous state was recorded for various US and PCCA conditions. Given the relationship between the hydrostatic pressure applied to the PCCA and US energy needed for activation, phase transition can be used as a surrogate of hydrostatic pressure. Consistent with theoretical predictions, the PCCA activation threshold was lowered with increasing sample temperature and by decreasing the frequency of US exposure, but it was not impacted by PCCA concentration.


Assuntos
Meios de Contraste , Pressão Hidrostática , Microbolhas , Ondas Ultrassônicas , Fluorocarbonos , Transição de Fase , Níveis Máximos Permitidos , Volatilização
17.
J Clin Invest ; 128(1): 309-322, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29202472

RESUMO

Type 2 diabetes mellitus (T2DM) is a common complication of obesity. Here, we have shown that activation of the IgG receptor FcγRIIB in endothelium by hyposialylated IgG plays an important role in obesity-induced insulin resistance. Despite becoming obese on a high-fat diet (HFD), mice lacking FcγRIIB globally or selectively in endothelium were protected from insulin resistance as a result of the preservation of insulin delivery to skeletal muscle and resulting maintenance of muscle glucose disposal. IgG transfer in IgG-deficient mice implicated IgG as the pathogenetic ligand for endothelial FcγRIIB in obesity-induced insulin resistance. Moreover, IgG transferred from patients with T2DM but not from metabolically healthy subjects caused insulin resistance in IgG-deficient mice via FcγRIIB, indicating that similar processes may be operative in T2DM in humans. Mechanistically, the activation of FcγRIIB by IgG from obese mice impaired endothelial cell insulin transcytosis in culture and in vivo. These effects were attributed to hyposialylation of the Fc glycan, and IgG from T2DM patients was also hyposialylated. In HFD-fed mice, supplementation with the sialic acid precursor N-acetyl-D-mannosamine restored IgG sialylation and preserved insulin sensitivity without affecting weight gain. Thus, IgG sialylation and endothelial FcγRIIB may represent promising therapeutic targets to sever the link between obesity and T2DM.


Assuntos
Diabetes Mellitus Tipo 2/metabolismo , Imunoglobulina G/metabolismo , Resistência à Insulina , Obesidade/metabolismo , Receptores de IgG/metabolismo , Animais , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/patologia , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Hexosaminas/farmacologia , Imunoglobulina G/genética , Camundongos , Camundongos Knockout , Obesidade/genética , Obesidade/patologia , Receptores de IgG/genética , Transcitose/efeitos dos fármacos
18.
Nanotheranostics ; 1(4): 440-449, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29188177

RESUMO

The abnormal tumor vasculature and the resulting abnormal microenvironment are major barriers to optimal chemotherapeutic drug delivery. It is well known that ultrasound (US) can increase the permeability of the tumor vessel walls and enhance the accumulation of anticancer agents. Reconstituted high-density lipoproteins (rHDL) nanoparticles (NPs) allow selective delivery of anticancer agents to tumor cells via their overexpressed scavenger receptor type B1 (SR-B1) receptor. The goal of this study is to investigate the potential of noninvasive US therapy to further improve delivery and tumor uptake of the payload from rHDL NPs, preloaded with an infrared dye (IR-780), aimed to establish a surrogate chemotherapeutic model with optical localization. Athymic nude mice were implanted orthotopically with one million breast cancer cells (MDA-MB-231/Luc). Three weeks later, animals were divided into seven groups with comparable mean tumor size: control, low, moderate, and high concentration of rHDL NPs alone groups, as well as these three levels of rHDL NPs plus US therapy groups (N = 7 to 12 animals per group), where low, moderate and high denote 5, 10, and 50 µg of the IR-780 dye payload per rHDL NP injection, respectively. The US therapy system included a single element focused transducer connected in series with a function generator and power amplifier. A custom 3D printed cone with an acoustically transparent aperture and filled with degassed water allowed delivery of focused US energy to the tumor tissue. US exposure involved a pulsed sequence applied for a duration of 5 min. Each animal in the US therapy groups received a slow bolus co-injection of MB contrast agent and rHDL NPs. Animals were imaged using a whole-body optical system to quantify intratumoral rHDL NP accumulation at baseline and again at 1 min, 30 min, 24 h, and 48 h. At 48 h, all animals were euthanized and tumors were excised for ex vivo analysis. We investigated a noninvasive optical imaging method for monitoring the effects of US-stimulated drug delivery of IR-780 dye-loaded rHDL NPs in living animals. No change in optical imaging data was found in the control animals. However, there was considerable dye accumulation (surrogate drug) within 48 h in the low (5 µg), moderate (10 µg), and high (50 µg) rHDL NP concentration-dosed group animals (p < 0.09). With US therapy added to the experimental protocol, there was an additional and significant increase in local tumor drug uptake at 48 h (p < 0.02). Optical image data collected from ex vivo tumor samples confirmed tumor retention of the IR-780 dye-loaded rHDL NPs and correlated positively with in vivo optical imaging results (R2 > 0.69, p < 0.003). IR-780 dye extraction from the tumor tissue samples confirmed the in vivo and ex vivo US therapy findings. Overall, the addition of US therapy considerably improved local rHDL NP accumulation in tumor tissue. This study concludes that US-mediated drug delivery can facilitate tumor uptake of rHDL NPs and more research is warranted to optimize the drug dosing schedule and the respective therapeutic protocols.

19.
ACS Appl Mater Interfaces ; 9(43): 37587-37596, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28994575

RESUMO

Acute deep vein thrombosis (DVT) is the formation of a blood clot in the deep veins of the body that can lead to fatal pulmonary embolism. Acute DVT is difficult to distinguish from chronic DVT by ultrasound (US), the imaging modality of choice, and is therefore treated aggressively with anticoagulants, which can lead to internal bleeding. Here we demonstrate that conjugating perfluorobutane-filled (PFB-filled) microbubbles (MBs) with thrombin-sensitive activatable cell-penetrating peptides (ACPPs) could lead to the development of contrast agents that detect acute thrombosis with US imaging. Successful conjugation of ACPP to PFB-filled MBs was confirmed by fluorescence microscopy and flow cytometry. Fluorescein-labeled ACPP was used to evaluate the efficiency of thrombin-triggered cleavage by measuring the mean fluorescence intensity of ACPP-labeled MBs (ACPP-MBs) before and after incubation at 37 °C with thrombin. Lastly, control MBs and ACPP-MBs were infused through a tube containing a clot, and US contrast enhancement was measured with or without the presence of a thrombin inhibitor after washing the clot with saline. With thrombin activity, 91.7 ± 14.2% of the signal was retained after ACPP-MB infusion and washing, whereas only 16.7 ± 4% of the signal was retained when infusing ACPP-MBs in the presence of hirudin, a potent thrombin inhibitor.


Assuntos
Microbolhas , Meios de Contraste , Humanos , Trombina , Trombose , Ultrassonografia
20.
Med Phys ; 44(12): 6304-6313, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28975635

RESUMO

PURPOSE: Microvascular processes play key roles in many diseases including diabetes. Improved understanding of the microvascular changes involved in disease development could offer crucial insight into the relationship of these changes to disease pathogenesis. Super-resolution ultrasound (SR-US) imaging has showed the potential to visualize microvascular detail down to the capillary level (i.e., subwavelength resolution), but optimization is still necessary. The purpose of this study was to investigate in vivo SR-US imaging of skeletal muscle microvascularity using microbubble (MB) contrast agents of various size and concentration while evaluating different ultrasound (US) system level parameters such as imaging frame rate and image acquisition length. METHODS: An US system equipped with a linear array transducer was used in a harmonic imaging mode at low transmit power. C57BL/6J mice fed a normal diet were used in this study. An assortment of size-selected MB contrast agents (1-2 µm, 3-4 µm, and 5-8 µm in diameter) were slowly infused in the tail vein at various doses (1.25 × 107 , 2.5 × 107 , or 5 × 107  MBs). US image data were collected before MB injection and thereafter for 10 min at 30 frames per s (fps). The US transducer was fixed throughout and between each imaging period to help capture microvascular patterns along the same image plane. An adaptive SR-US image processing technique was implemented using custom Matlab software. RESULTS: Experimental findings illustrate the use of larger MB results in better SR-US images in terms of skeletal muscle microvascular detail. A dose of 2.5 × 107  MBs resulted in SR-US images with optimal spatial resolution. An US imaging rate of at least 20 fps and image acquisition length of at least 8 min also resulted in SR-US images with pronounced microvascular detail. CONCLUSIONS: This study indicates that MB size and dose and US system imaging rate and data acquisition length have significant impact on the quality of in vivo SR-US images of skeletal muscle microvascularity.


Assuntos
Meios de Contraste , Microbolhas , Razão Sinal-Ruído , Ultrassonografia/métodos , Animais , Processamento de Imagem Assistida por Computador , Camundongos , Músculo Esquelético/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...