1.
Clin Biochem ; 46(18): 1889-91, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24036022

RESUMO

OBJECTIVE: Newborn screening for biotinidase deficiency can be performed using a fluorometric enzyme assay on dried blood spot specimens. As a pre-requisite to the consolidation of different enzymatic assays onto a single platform, we describe here a novel analytical method for detecting biotinidase deficiency using the same digital microfluidic cartridge that has already been demonstrated to screen for five lysosomal storage diseases (Pompe, Fabry, Gaucher, Hurler and Hunter) in a multiplex format. METHODS: A novel assay to quantify biotinidase concentration in dried blood spots (DBS) was developed and optimized on the digital microfluidic platform using proficiency testing samples from the Centers for Disease Control and Prevention. The enzymatic assay uses 4-methylumbelliferyl biotin as the fluorogenic substrate. Biotinidase deficiency assays were performed on normal (n=200) and deficient (n=7) newborn DBS specimens. RESULTS: Enzymatic activity analysis of biotinidase deficiency revealed distinct separation between normal and affected DBS specimens using digital microfluidics and these results matched the expected activity. CONCLUSIONS: This study has demonstrated performance of biotinidase deficiency assays by measurement of 4-methylumbelliferyl product on a digital microfluidic platform. Due to the inherent ease in multiplexing on such a platform, consolidation of other fluorometric assays onto a single cartridge may be realized.


Assuntos
Deficiência de Biotinidase/sangue , Ensaios Enzimáticos/métodos , Microfluídica/métodos , Triagem Neonatal/métodos , Biotina/análogos & derivados , Biotina/metabolismo , Deficiência de Biotinidase/diagnóstico , Teste em Amostras de Sangue Seco , Ensaios Enzimáticos/instrumentação , Fluorometria , Humanos , Recém-Nascido , Umbeliferonas/metabolismo
2.
Clin Chim Acta ; 424: 12-8, 2013 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-23660237

RESUMO

PURPOSE: New therapies for lysosomal storage diseases (LSDs) have generated interest in screening newborns for these conditions. We present performance validation data on a digital microfluidic platform that performs multiplex enzymatic assays for Pompe, Fabry, Hunter, Gaucher, and Hurler diseases. METHODS: We developed an investigational disposable digital microfluidic cartridge that uses a single dried blood spot (DBS) punch for performing a 5-plex fluorometric enzymatic assay on up to 44 DBS samples. Precision and linearity of the assays were determined by analyzing quality control DBS samples; clinical performance was determined by analyzing 600 presumed normal and known affected samples (12 for Pompe, 7 for Fabry and 10 each for Hunter, Gaucher and Hurler). RESULTS: Overall coefficient of variation (CV) values between cartridges, days, instruments, and operators ranged from 2 to 21%; linearity correlation coefficients were ≥0.98 for all assays. The multiplex enzymatic assay performed from a single DBS punch was able to discriminate presumed normal from known affected samples for 5 LSDs. CONCLUSIONS: Digital microfluidic technology shows potential for rapid, high-throughput screening for 5 LSDs in a newborn screening laboratory environment. Sample preparation to enzymatic activity on each cartridge is less than 3h.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Doenças por Armazenamento dos Lisossomos/diagnóstico , Microfluídica/métodos , Triagem Neonatal , alfa-Glucosidases/sangue , Teste em Amostras de Sangue Seco , Ensaios Enzimáticos , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/normas , Humanos , Recém-Nascido , Doenças por Armazenamento dos Lisossomos/sangue , Doenças por Armazenamento dos Lisossomos/classificação , Microfluídica/instrumentação , Microfluídica/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , alfa-Glucosidases/deficiência
3.
Mol Genet Metab ; 109(2): 218-20, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23578771

RESUMO

OBJECTIVE: Easy tool for newborn screening of Gaucher and Hurler diseases. METHODS: Method comparison between fluorometric enzymatic activity assay on a digital microfluidic platform and micro-titer plate bench assay was performed on normal (n = 100), Gaucher (n = 10) and Hurler (n = 7) dried blood spot samples. RESULTS: Enzymatic activity analysis of glucocerebrosidase (Gaucher) and α-l-iduronidase (Hurler) revealed similar discrimination between normal and affected samples on both platforms. CONCLUSIONS: Digital microfluidics is suitable for Gaucher and Hurler newborn screening.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Doença de Gaucher/diagnóstico , Mucopolissacaridose I/diagnóstico , Ensaios Enzimáticos , Doença de Gaucher/sangue , Glucosilceramidase/sangue , Humanos , Iduronidase/sangue , Recém-Nascido , Microfluídica , Mucopolissacaridose I/sangue , Triagem Neonatal
4.
Blood Coagul Fibrinolysis ; 23(8): 760-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22964771

RESUMO

Current methods for hypercoagulability panel testing require large blood volumes and long turn-around testing times. A novel microfluidic platform has been designed to perform automated multiplexed hypercoagulability panel testing at near patient, utilizing only a single droplet of blood sample. We test the hypothesis that this novel platform could be utilized to perform specific multiplexed ELISA-based hypercoagulability panel testing for antithrombin III, protein C, protein S and factor VIII antigens, as well as anticardiolipin/human anti-ß2-glycoprotein-1 IgG antibodies--on blood samples. Sandwich ELISA was modified by utilizing magnetic beads coated with specific antibodies as the solid phase using fluorescence readout. Percentage recovery was calculated using four-parameter logistic curves. On-chip ELISA with single factors was compared with multiplex factor ELISA for known concentrations of sample. Blood samples were analyzed on-chip and compared with traditional bench-top assays. Time for multiplexed performance of hypercoagulability panel ELISA on-chip with controls is 72 min. Recovery rates (range 80-120%) for known concentrations of specific factors was not significantly different when assays were performed using a single factor vs. multiplex factor analysis. Assay results were not significantly different between individual assays performed either on bench-top or on-chip with patient blood and/or plasma. Utilizing a novel digital microfluidic platform, we demonstrate the feasibility of automated hypercoagulability panel testing on small volume of plasma and whole blood patient samples with high fidelity. Further investigation is required to test the application of this novel technology at point-of-care clinical settings.


Assuntos
Ensaio de Imunoadsorção Enzimática/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Trombofilia/sangue , Trombofilia/diagnóstico , Anticorpos Anticardiolipina/sangue , Antitrombina III/análise , Automação Laboratorial , Calibragem , Ensaio de Imunoadsorção Enzimática/métodos , Fator VIII/análise , Humanos , Imunoglobulina G/sangue , Técnicas Analíticas Microfluídicas/métodos , Proteína C/análise , Proteína S/análise , Reprodutibilidade dos Testes , beta 2-Glicoproteína I/sangue , beta 2-Glicoproteína I/imunologia
5.
Mol Genet Metab ; 105(3): 519-21, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22227323

RESUMO

Mucopolysaccharidosis type II (MPS II) or Hunter syndrome is a lysosomal storage disease caused by deficiency of iduronate-2-sulfatase (IDS). A convenient single-step fluorometric microplate enzyme assay has been developed and validated for clinical diagnosis of MPS II using dried blood spots (DBS). The assay compared well with a recently reported digital microfluidic method, from which it was adapted. Results show that this DBS assay is robust and reproducible using both technologies.


Assuntos
Teste em Amostras de Sangue Seco , Ensaios Enzimáticos/métodos , Iduronato Sulfatase/sangue , Mucopolissacaridose II/diagnóstico , Fluorometria/métodos , Humanos , Iduronato Sulfatase/genética , Técnicas Analíticas Microfluídicas , Mucopolissacaridose II/sangue , Mucopolissacaridose II/enzimologia
6.
Clin Chem ; 57(10): 1444-51, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21859904

RESUMO

BACKGROUND: Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS: We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS: Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS: A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.


Assuntos
Ensaios Enzimáticos Clínicos/instrumentação , Doença de Fabry/diagnóstico , Doença de Depósito de Glicogênio Tipo II/diagnóstico , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , alfa-Galactosidase/sangue , alfa-Glucosidases/sangue , Fluorometria , Humanos , Recém-Nascido , Triagem Neonatal
8.
Semin Perinatol ; 34(2): 163-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20207266

RESUMO

Expansion of newborn screening for inherited metabolic disorders using tandem mass spectrometry has generated interest in screening for other treatable conditions, including lysosomal storage diseases. Limitations to expansion include labor and equipment costs. We describe a cost-effective new platform that reduces the time to result reporting and can perform multiplexing assays requiring different platforms. Immunoassays and enzyme activity assays currently used in newborn screening have been translated to a disposable microchip programmed to dispense, transport, mix, wash, and incubate individual microdroplets from specimens, including dried blood spot extracts, and reagents all under software control. The specimen and reagents consumed are approximately 1% of those required by equivalent bench assays. In addition to immunologic and enzymatic assays, DNA amplification, amplicon detection, and sequencing have been demonstrated using the same microchips and control equipment. Recently, the multiplexing of 4 different enzyme activities has also been demonstrated with negligible cross-contamination. We review assays relevant to newborn screening.


Assuntos
Técnicas Analíticas Microfluídicas , Triagem Neonatal/métodos , Ensaios Enzimáticos/métodos , Humanos , Imunoensaio/métodos , Recém-Nascido , Técnicas de Amplificação de Ácido Nucleico/métodos
9.
Lab Chip ; 8(12): 2091-104, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19023472

RESUMO

Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are rapid results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial infectious disease pathogen, methicillin-resistant Staphylococcus aureus and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care.


Assuntos
Microfluídica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Análise Química do Sangue , DNA/química , Humanos , Imunoensaio , Luminescência , Microfluídica/instrumentação , Fatores de Tempo
10.
Lab Chip ; 8(12): 2188-96, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19023486

RESUMO

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore does not suffer from clogging of channels. Immunoassays on a digital microfluidic platform require the following basic operations: bead attraction, bead washing, bead retention, and bead resuspension. Several parameters such as magnetic field strength, pull force, position, and buffer composition were studied for effective bead operations. Dilution-based washing of magnetic beads was demonstrated by immobilizing the magnetic beads using a permanent magnet and splitting the excess supernatant using electrowetting. Almost 100% bead retention was achieved after 7776-fold dilution-based washing of the supernatant. Efficient resuspension of magnetic beads was achieved by transporting a droplet with magnetic beads across five electrodes on the platform and exploiting the flow patterns within the droplet to resuspend the beads. All the magnetic-bead droplet operations were integrated together to generate standard curves for sandwich heterogeneous immunoassays on human insulin and interleukin-6 (IL-6) with a total time to result of 7 min for each assay.


Assuntos
Imunoensaio , Magnetismo , Microfluídica/instrumentação , Microfluídica/métodos , Humanos , Imunoensaio/métodos , Insulina/química , Interleucina-6/química , Magnetismo/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...