Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 19(Pt 6): 1050-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23093769

RESUMO

X-ray velocimetry offers a non-invasive method by which blood flow, blood velocity and wall shear stress can be measured in arteries prone to atherosclerosis. Analytical tools for measuring haemodynamics in artificial arteries have previously been developed and here the first quantification of haemodynamics using X-ray velocimetry in a living mammalian artery under physiologically relevant conditions is demonstrated. Whole blood seeded with a clinically used ultrasound contrast agent was pumped with a steady flow through live carotid arterial tissue from a rat, which was kept alive in a physiological salt solution. Pharmacological agents were then used to produce vascular relaxation. Velocity measurements were acquired with a spatial resolution of 14 µm × 14 µm and at a rate of 5000 acquisitions per second. Subtle velocity changes that occur are readily measurable, demonstrating the ability of X-ray velocimetry to sensitively and accurately measure haemodynamics ex vivo. Future applications and possible limitations of the technique are discussed, which allows for detailed living tissue investigations to be carried out for various disease models, including atherosclerosis and diabetic vasculopathy.


Assuntos
Artérias Carótidas/fisiologia , Humanos , Técnicas In Vitro , Raios X
2.
Gene Ther ; 19(1): 8-14, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21654825

RESUMO

Although airway gene transfer research in mouse models relies on bolus fluid dosing into the nose or trachea, the dynamics and immediate fate of delivered gene transfer agents are poorly understood. In particular, this is because there are no in vivo methods able to accurately visualize the movement of fluid in small airways of intact animals. Using synchrotron phase-contrast X-ray imaging, we show that the fate of surrogate fluid doses delivered into live mouse airways can now be accurately and non-invasively monitored with high spatial and temporal resolution. This new imaging approach can help explain the non-homogenous distributions of gene expression observed in nasal airway gene transfer studies, suggests that substantial dose losses may occur at deliver into mouse trachea via immediate retrograde fluid motion and shows the influence of the speed of bolus delivery on the relative targeting of conducting and deeper lung airways. These findings provide insight into some of the factors that can influence gene expression in vivo, and this method provides a new approach to documenting and analyzing dose delivery in small-animal models.


Assuntos
Técnicas de Transferência de Genes , Sistema Respiratório/diagnóstico por imagem , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Feminino , Terapia Genética , Processamento de Imagem Assistida por Computador/métodos , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Pulmão/anatomia & histologia , Pulmão/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos C57BL , Mecânica Respiratória , Sistema Respiratório/anatomia & histologia
3.
Phys Med Biol ; 56(23): 7353-69, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-22048612

RESUMO

We demonstrate interface-specific propagation-based x-ray phase retrieval tomography of the thorax and brain of small animals. Our method utilizes a single propagation-based x-ray phase-contrast image per projection, under the assumptions of (i) partially coherent paraxial radiation, (ii) a static object whose refractive indices take on one of a series of distinct values at each point in space and (iii) the projection approximation. For the biological samples used here, there was a 9-200 fold improvement in the signal-to-noise ratio of the phase-retrieved tomograms over the conventional attenuation-contrast signal. The ability to 'digitally dissect' a biological specimen, using only a single phase-contrast image per projection, will be useful for low-dose high-spatial-resolution biomedical imaging of form and biological function in both healthy and diseased tissue.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Encéfalo/diagnóstico por imagem , Feminino , Gravidez , Coelhos , Radiografia Torácica , Ratos , Razão Sinal-Ruído
4.
Phys Med Biol ; 56(21): 6779-91, 2011 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-21971037

RESUMO

Structural changes in breast tissue at the nanometre scale have been shown to differentiate between tissue types using synchrotron SAXS techniques. Classification of breast tissues using information acquired from a laboratory SAXS camera source could possibly provide a means of adopting SAXS as a viable diagnostic procedure. Tissue samples were obtained from surgical waste from 66 patients and structural components of the tissues were examined between q = 0.25 and 2.3 nm(-1). Principal component analysis showed that the amplitude of the fifth-order axial Bragg peak, the magnitude of the integrated intensity and the full-width at half-maximum of the fat peak were significantly different between tissue types. A discriminant analysis showed that excellent classification can be achieved; however, only 30% of the tissue samples provided the 16 variables required for classification. This suggests that the presence of disease is represented by a combination of factors, rather than one specific trait. A closer examination of the amorphous scattering intensity showed not only a trend of increased scattering intensity with disease severity, but also a corresponding decrease in the size of the scatterers contributing to this intensity.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Espalhamento a Baixo Ângulo , Difração de Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Neoplasias da Mama/classificação , Neoplasias da Mama/diagnóstico por imagem , Estudos de Casos e Controles , Análise Discriminante , Feminino , Humanos , Microfibrilas/diagnóstico por imagem , Microfibrilas/patologia , Análise de Componente Principal , Radiografia , Índice de Gravidade de Doença , Síncrotrons
5.
Opt Express ; 18(13): 13478-91, 2010 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-20588478

RESUMO

A rotating random-phase-screen diffuser is sometimes employed on synchrotron x-ray imaging beamlines to ameliorate field-of-view inhomogeneities due to electron-beam instabilities and beamline optics phase artifacts. The ideal result is a broader, more uniformly illuminated beam intensity for cleaner coherent x-ray images. The spinning diffuser may be modeled as an ensemble of transversely random thin phase screens, with the resulting set of intensity maps over the detector plane being incoherently averaged over the ensemble. Whilst the coherence width associated with the source is unaffected by the diffuser, the magnitude of the complex degree of second-order coherence may be significantly reduced [K. S. Morgan, S. C. Irvine, Y. Suzuki, K. Uesugi, A. Takeuchi, D. M. Paganin, and K. K. W. Siu, Opt. Commun. 283, 216 (2010)]. Through use of a computational model and experimental data obtained on x-ray beamline BL20XU at SPring-8, Japan, we investigate the effects of such a diffuser on the quality of Fresnel diffraction fringes in propagation-based x-ray phase contrast imaging. We show that careful choice of diffuser characteristics such as thickness and fiber size, together with appropriate placement of the diffuser, can result in the ideal scenario of negligible reduction in fringe contrast whilst the desired diffusing properties are retained.


Assuntos
Simulação por Computador , Tecido Conjuntivo/diagnóstico por imagem , Modelos Biológicos , Radiografia/instrumentação , Radiografia/métodos , Síncrotrons , Desenho de Equipamento , Análise de Fourier , Fluxo Sanguíneo Regional
6.
Opt Express ; 18(10): 9865-78, 2010 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-20588836

RESUMO

We examine the projection approximation in the context of propagation-based phase contrast imaging using hard x-rays. Specifically, we consider the case of a cylinder or a rounded edge, as a simple model for the edges of many biological samples. The Argand-plane signature of a propagation-based phase contrast fringe from the edge of a cylinder is studied, and the evolution of this signature with propagation. This, along with experimental images obtained using a synchrotron source, reveals how propagation within the scattering volume is not fully described in the projection approximation's ray-based approach. This means that phase contrast fringes are underestimated by the projection approximation at a short object-to-detector propagation distance, namely a distance comparable to the free-space propagation within the volume. This failure of the projection approximation may become non-negligible in the detailed study of small anatomical features deep within a large body. Nevertheless, the projection approximation matches the exact solution for a larger propagation distance typical of those used in biomedical phase contrast imaging.


Assuntos
Microscopia de Contraste de Fase/métodos , Modelos Biológicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia/métodos , Simulação por Computador , Espalhamento de Radiação
7.
Eur J Radiol ; 68(3 Suppl): S73-7, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18996661

RESUMO

Synchrotron-based propagation-based imaging, a type of phase contrast imaging, produces better soft tissue image contrast than conventional radiography. To determine whether the technique is directly transferable to the clinical environment for routine diagnostic or screening imaging, a micro-focus (100 microm spot-size) Molybdenum X-ray source with 0.03 mm molybdenum filtration was installed at a local hospital. Breast tissue samples, excised masses and mastectomies, were obtained directly from surgery and imaged at three geometries. The first geometry was optimised for visualizing phase contrast effects using a ray-line argument, the second was the same as that employed by Konica-Minolta in their commercial phase contrast system, and the third was the conventional contact arrangement. The three images taken of each tissue sample were comparatively scored in a pair-wise fashion. Scoring was performed by radiologist expert in mammography, general radiologists, associated clinicians and radiographers on high-resolution mammography rated monitors at two separate locations. Scoring indicated that the optimised and Konica geometries both outperformed the conventional mammographic geometry. An unexpected complication within the trial was the effect that the scoring platform and the associated display tools had on some of the scorer's responses. Additionally, the trial revealed that none of the conventional descriptors for image quality were adequate in the presence of phase contrast enhancements.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Refratometria/métodos , Tomografia por Raios X/métodos , Algoritmos , Ensaios Clínicos como Assunto , Feminino , Humanos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Phys Med Biol ; 53(21): 6065-77, 2008 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-18843172

RESUMO

Phase contrast x-ray imaging can provide detailed images of lung morphology with sufficient spatial resolution to observe the terminal airways (alveoli). We demonstrate that quantitative functional and anatomical imaging of lung ventilation can be achieved in vivo using two-dimensional phase contrast x-ray images with high contrast and spatial resolution (<100 microm) in near real time. Changes in lung air volume as small as 25 microL were calculated from the images of term and preterm rabbit pup lungs (n = 28) using a single-image phase retrieval algorithm. Comparisons with plethysmography and computed tomography showed that the technique provided an accurate and robust method of measuring total lung air volumes. Furthermore, regional ventilation was measured by partitioning the phase contrast images, which revealed differences in aeration for different ventilation strategies.


Assuntos
Medidas de Volume Pulmonar/métodos , Pulmão/fisiologia , Animais , Pletismografia , Coelhos , Radiografia , Reprodutibilidade dos Testes , Respiração , Raios X
9.
Eur J Radiol ; 68(3 Suppl): S22-6, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18599234

RESUMO

We seek to establish non-invasive imaging able to detect and measure aspects of the biology and physiology of surface fluids present on airways, in order to develop novel outcome measures able to validate the success of proposed genetic or pharmaceutical therapies for cystic fibrosis (CF) airway disease. Reduction of the thin airway surface liquid (ASL) is thought to be a central pathophysiological process in CF, causing reduced mucociliary clearance that supports ongoing infection and destruction of lung and airways. Current outcome measures in animal models, or humans, are insensitive to the small changes in ASL depth that ought to accompany successful airway therapies. Using phase contrast X-ray imaging (PCXI), we have directly examined the airway surfaces in the nasal airways and tracheas of anaesthetised mice, currently to a resolution of approximately 2 microm. We have also achieved high resolution three-dimensional (3D) imaging of the small airways in mice using phase-contrast enhanced computed tomography (PC-CT) to elucidate the structure-function relationships produced by airway disease. As the resolution of these techniques improves they may permit non-invasive monitoring of changes in ASL depth with therapeutic intervention, and the use of 3D airway and imaging in monitoring of lung health and disease. Phase contrast imaging of airway surfaces has promise for diagnostic and monitoring options in animal models of CF, and the potential for future human airway imaging methodologies is also apparent.


Assuntos
Fibrose Cística/diagnóstico por imagem , Modelos Animais de Doenças , Pulmão/diagnóstico por imagem , Refratometria/métodos , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Phys Med Biol ; 52(14): 4171-87, 2007 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-17664601

RESUMO

Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 microm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Óptica e Fotônica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Phys Med Biol ; 50(21): 5031-40, 2005 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-16237239

RESUMO

High quality real-time imaging of lungs in vivo presents considerable challenges. We demonstrate here that phase contrast x-ray imaging is capable of dynamically imaging the lungs. It retains many of the advantages of simple x-ray imaging, whilst also being able to map weakly absorbing soft tissues based on refractive index differences. Preliminary results reported herein show that this novel imaging technique can identify and locate airway liquid and allows lung aeration in newborn rabbit pups to be dynamically visualized.


Assuntos
Pulmão/patologia , Radiografia Torácica/métodos , Animais , Animais Recém-Nascidos , Humanos , Coelhos , Intensificação de Imagem Radiográfica , Ampliação Radiográfica , Respiração , Fatores de Tempo , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...