Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
J Commun Disord ; 109: 106426, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38692192

RESUMO

INTRODUCTION: Central auditory processing disorders (CAPD) can significantly affect the daily functioning of a child, and the first step in determining whether rehabilitation procedures are required is a proper diagnosis. Different guidelines for making diagnoses have been published in the literature, and in various centers normative values for psychoacoustic tests of CAPD have been used internally. The material presented in this paper is based on more than 1000 children and is the largest collection so far published. The aim of this study is to present normative values for tests assessing CAPD in children aged 6 to 12 years, divided by age at last birthday. METHOD: We tested 1037 children aged 6 to 12 years who were attending primary schools and kindergartens. The criteria for inclusion were a normal audiogram, intellectually normal, no developmental problems, and no difficulties in auditory processing. To evaluate auditory processing all children were given three tests on the Senses Examination Platform: the Frequency Pattern Test (FPT), Duration Pattern Test (DPT), and Dichotic Digit Test (DDT). RESULTS: The results from 1,037 children allowed us to determine normative values for FPT, DPT, and DDT in seven different age groups (6 through to 12 years). We developed a newapproach, based on quantile-based norms, to determine normative values in each group. Three categories - average, below-average, and above-average - allow for a broader but more realistic interpretation than those used previously. We compare our results with published standards. CONCLUSIONS: Our study is the largest normative database published to date for CAPD testing, setting a standard for each child by age in years. We used the Senses Examination Platform, a universal tool, to unify standards for the classification of CAPD. Our study can serve as a basis for the development of a Polish model for the diagnosis of CAPD.

2.
Brain Sci ; 14(2)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38391748

RESUMO

This study looked at the possible effect of the COVID-19 pandemic on individuals who came to our clinic seeking relief from tinnitus. The performance of the subjects during the COVID-19 pandemic was compared with similar individuals who came to our clinic before the pandemic began. The study involved 50 adults with chronic tinnitus, made up of a study group (24 subjects tested during the COVID-19 pandemic of 2020-2021) and a control group before the pandemic began (26 subjects tested from 2013 to 2017). None of the 24 reported having contracted COVID-19. Data collection involved the Tinnitus Handicap Inventory (THI) questionnaire, audiological tests, and quantitative electroencephalography (qEEG). In terms of THI scores, there were no statistically significant differences between the two groups. However, with regard to qEEG, some changes were observed, with significant decreases in alpha and beta band activity in the study group compared to the control group, particularly over the auditory cortex. We conclude that COVID-19 did not have a discernible impact on the general well-being of individuals with tinnitus. However, it did appear to alter brain activity, specifically in the alpha and beta bands over the auditory cortex, and these reults warrant further investigation.

3.
Int J Audiol ; 63(4): 250-259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36799648

RESUMO

OBJECTIVES: The aim of this interventional non-randomised prospective controlled study was to assess the effectiveness of transcutaneous vagus nerve stimulation (tVNS) in human subjects with tinnitus. DESIGN: The ParasymTM tVNS device was paired with an auditory stimulation. Treatment and observations were conducted over 12 weeks. Audiological evaluation was performed. Responses from a set of questionnaires and quantitative electroencephalography (qEEG) before and after treatment were collected. Voice measurements were done to assess possible side-effects of tVNS. STUDY SAMPLE: The study involved 29 adults who had chronic tinnitus (15 patients who underwent tVNS paired with sounds and a control group of 14 patients who did not). RESULTS: In general, subjective and objective measurements of tinnitus showed no improvement in the study group compared to the controls, although certain parameters as gauged by the questionnaires did statistically improve. The loudness and frequency of tinnitus remained the same in both groups. For the qEEG, activity in the theta band increased significantly in the study group compared to the control group. CONCLUSIONS: The tVNS was not effective in reducing tinnitus symptoms in our study group. However, changes in the theta band suggest there might be cortical effects that might, with sustained treatment, lead to improvements.


Assuntos
Zumbido , Estimulação Elétrica Nervosa Transcutânea , Estimulação do Nervo Vago , Adulto , Humanos , Estudos Prospectivos , Projetos de Pesquisa , Zumbido/diagnóstico , Zumbido/terapia , Estimulação do Nervo Vago/efeitos adversos
4.
Eur Arch Otorhinolaryngol ; 281(5): 2353-2363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133806

RESUMO

PURPOSE: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis. METHODS: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE). RESULTS: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA4 ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA4 thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA4 ABG of ≤ 20 dB. None of the children reported a BC PTA4 deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days. CONCLUSION: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults. TRIAL REGISTRATION NUMBER: NCT05565339, 09 September 2022, retrospectively registered.


Assuntos
Prótese Ossicular , Adulto , Criança , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Implantação de Prótese , Condução Óssea , Audiometria de Tons Puros
5.
Am J Case Rep ; 24: e940439, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37786244

RESUMO

BACKGROUND Brown-Vialetto-Van Laere (BVVL) syndrome is a rare autosomal recessive disorder caused by mutations in intestinal riboflavin transporter genes, resulting in a motor neuron disorder of childhood, which can be associated with sensorineural deafness. This report describes a 4-year-old Polish girl with progressive hearing loss and delayed speech development diagnosed with Brown-Vialetto-Van Laere syndrome who was treated with riboflavin (vitamin B2) and cochlear implants. CASE REPORT The case report concerns a girl from Poland who, at the age of 2 years 10 months, developed progressive atypical neurological symptoms of unknown etiology: ataxia of the upper and lower limbs, gait abnormalities, generalized muscle weakness, visual and hearing problems, and regression of speech development. A karyotype study (whole-exome sequencing) revealed alterations within SLC52A2, leading to the diagnosis of Brown-Vialetto-Van Laere syndrome and initiation of high-dose riboflavin treatment. As a 4-year-old child, she presented to the Institute of Physiology and Pathology of Hearing - World Hearing Center in Poland with progressive hearing loss and speech regression. Hearing tests revealed bilateral profound sensorineural hearing loss with auditory neuropathy. Surgical treatment was applied in the form of bilateral cochlear implantation. CONCLUSIONS This report shows the importance of genetic testing in infants who present with atypical symptoms or signs. In this case, the diagnosis of Brown-Vialetto-Van Laere syndrome resulted in timely correction of the genetic riboflavin (vitamin B2) deficiency and improved hearing following the use of cochlear implants.


Assuntos
Paralisia Bulbar Progressiva , Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Feminino , Lactente , Humanos , Pré-Escolar , Fala , Perda Auditiva Neurossensorial/etiologia , Paralisia Bulbar Progressiva/complicações , Paralisia Bulbar Progressiva/diagnóstico , Paralisia Bulbar Progressiva/genética , Riboflavina/uso terapêutico , Surdez/complicações , Surdez/tratamento farmacológico
6.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892760

RESUMO

Hyperacusis, a kind of decreased sound tolerance, is difficult to measure objectively. It often co-occurs with tinnitus. There is a need for valid and reliable patient-reported outcome measures to capture this subjective phenomenon. The aim of the study was to create a questionnaire capturing hyperacusis in terms of loudness, fear, and pain and to evaluate its psychometric properties. The study sample consisted of 106 adult patients with hyperacusis and tinnitus with a mean age of 45.2 years. A medical interview, an audiological examination, and several questionnaires (the Tinnitus Handicap Inventory, the Hyperacusis Questionnaire, the State-Trait Anxiety Inventory, and Visual Analog Scales) were applied. The final 14-item Hyperacusis Assessment Questionnaire showed an appropriate three-factor structure with 70.5% of the variance explained. Convergent and divergent validity were confirmed by correlations with other measures of hyperacusis, anxiety, tinnitus severity, misophonia, and hearing thresholds. The internal consistency assessed with Cronbach's alpha was excellent (α = 0.91), as was reproducibility (intraclass correlation, ICC = 0.96). The new Hyperacusis Assessment Questionnaire is a psychometrically sound and brief tool assessing the severity of hyperacusis in terms of loudness, fear, and pain. It can be used in clinical practice and scientific research for patients with hyperacusis and tinnitus.

7.
Front Neurol ; 14: 1225135, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37475734

RESUMO

Background: A retrospective clinical study was conducted to test the impact of including hyperbaric oxygen therapy in the treatment of patients with sudden sensorineural hearing loss (SSNHL). Materials and methods: A total of 63 adult patients with sudden sensorineural hearing loss diagnosed between 2015 and 2023 were divided into two groups: 36 patients treated with intratympanic glucocorticoid and orally administered glucocorticoid who also underwent hyperbaric oxygen therapy and 27 patients treated with intratympanic glucocorticoid and prolonged orally administered glucocorticoid (without hyperbaric oxygen therapy). An audiological evaluation was performed using pure-tone audiometry. Results: Average hearing gain as measured by pure tone average was 12.5 dB HL (+/- 19.9 dB HL) in the patients treated with steroids combined with HBOT, and was 14.1 dB HL (+/- 17.9 dB) in the patients treated with steroids alone. Successful treatment (complete recovery or marked improvement) was observed in 27.8% of the patients in the first group and in 25.5% in the second group. There was no statistically significant difference between the groups. Conclusion: Both groups of patients-those treated with glucocorticoids and those treated with glucocorticoids and HBOT-had similar hearing outcomes. A prospective, controlled, and randomized study would provide more reliable knowledge about the efficacy of HBOT in treating SSNHL.

8.
Audiol Neurootol ; 28(6): 458-465, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37315543

RESUMO

INTRODUCTION: The electrode length is one of the many factors impacted on results of cochlear implantation. Among lateral wall flexible electrode arrays the latest one is FLEX26 (MED-EL GmbH, Innsbruck, Austria). The main aim of the study was to evaluate the preservation of residual hearing, the level of speech understanding, and quality of life after cochlear implantation with FLEX26 electrode array. METHODS: The study was conducted in a tertiary referral centre. Fifty-two patients implanted unilaterally with FLEX26, including 10 EAS patients (electric acoustic stimulation) and 42 ES patients (electric stimulation). The intervention was minimally invasive cochlear implantation via the round window. Pure-tone audiometry (0.125-8 kHz) was performed preoperatively and at 1, 6, and 12 months postoperatively. Twelve-month hearing preservation was established using HEARRING group formula. Quality of life was measured with AQoL-8D (Assessment of Quality of Life-8 Dimensions) pre- and postoperatively. RESULTS: Residual hearing was preserved in 88.8% EAS patients. Quality of life was significantly better postoperatively in comparison to preoperative period (the effect size for overall quality of life was 0.49). Especially, it increased in relationships and senses dimensions (the effect sizes 0.47 and 0.44, respectively). CONCLUSION: Preservation of residual hearing can be achieved in the majority of patients implanted with FLEX26. Improvement of quality of life was also documented. FLEX26 seems to be an option for surgeons who seek an electrode providing sufficient cochlear coverage.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Implante Coclear/métodos , Qualidade de Vida , Audição/fisiologia , Cóclea/cirurgia , Audiometria de Tons Puros , Percepção da Fala/fisiologia , Resultado do Tratamento , Limiar Auditivo/fisiologia , Estudos Retrospectivos
9.
Int J Audiol ; : 1-9, 2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37210625

RESUMO

OBJECTIVES: Tinnitus is a phantom sound sensation without an external sound source. Due to its subjective and multifaceted nature it is measured using multi-item self-reported instruments. Many well-validated tinnitus-related questionnaires are available for clinical practice and scientific research, but so far no attention has been paid to their measurement invariance. The study aimed to examine measurement invariance of the Tinnitus Handicap Inventory with regard to gender and hearing impairment, and to identify the items that show differential item functioning (DIF) across the groups. DESIGN: This is a retrospective study using medical data from patients with tinnitus. They completed the Tinnitus Handicap Inventory (THI) and underwent pure-tone audiometry. STUDY SAMPLE: 1106 adult patients with tinnitus (554 women and 552 men; 320 with normal hearing and 786 with hearing loss), aged 19-84 years. RESULTS: In the analysis, multi-group confirmatory factor analysis, hybrid ordinal logistic regression, Kernel smoothing in Item Response Theory, and lasso regression were applied. Measurement invariance was demonstrated across gender, but across hearing status the measurement was non-invariant. Five items were found to have DIF. CONCLUSIONS: Researchers and clinicians should be aware of the potential risk of response bias when tinnitus severity is evaluated.

10.
Artigo em Inglês | MEDLINE | ID: mdl-36232025

RESUMO

Heart rate time series are widely used to characterize physiological states and athletic performance. Among the main indicators of metabolic and physiological states, the detection of metabolic thresholds is an important tool in establishing training protocols in both sport and clinical fields. This paper reviews the most common methods, applied to heart rate (HR) time series, aiming to detect metabolic thresholds. These methodologies have been largely used to assess energy metabolism and to identify the appropriate intensity of physical exercise which can reduce body weight and improve physical fitness. Specifically, we focused on the main nonlinear signal evaluation methods using HR to identify metabolic thresholds with the purpose of identifying a method which can represent a useful tool for the real-time settings of wearable devices in sport activities. While the advantages and disadvantages of each method, and the possible applications, are presented, this review confirms that the nonlinear analysis of HR time series represents a solid, robust and noninvasive approach to assess metabolic thresholds.


Assuntos
Teste de Esforço , Aptidão Física , Exercício Físico , Frequência Cardíaca/fisiologia , Fatores de Tempo
11.
Pharmaceuticals (Basel) ; 15(10)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36297289

RESUMO

The main aim of this study was to assess the clinical effect of steroids (dexamethasone and prednisone) on hearing preservation in patients who underwent cochlear implantation with different cochlear implant systems (Oticon®, Advanced Bionics®, Med-El®). 147 adult patients met the inclusion criteria and were enrolled to the study and divided into three groups depending on the brand of cochlear implant they received and participated in all follow-up visits regularly. They were also randomly divided into three subgroups depending on the steroid administration regime: (1) intravenous dexamethasone (0.1 mg/kg body weight twice a day for three days); (2) combined intravenous and oral steroids (dexamethasone 0.1 mg/kg body weight twice a day plus prednisone 1 mg/kg weight once a day); and (3) no steroids (control group). The results were measured by pure tone audiometry (PTA) at three time points: (i) before implantation, (ii) at processor activation, and (iii) 12 months after activation. A hearing preservation (HP) figure was also calculated by comparing the preoperative results and the results after 12 months. Further measures collected were electrode impedance and hearing threshold in the non-operated ear. The highest HP measures (partial and complete) were obtained in the subgroups who were given steroids. Of the 102 patients given steroids, HP was partial or complete in 63 of them (62%). In comparison, partial or complete HP was achieved in only 15 patients out of 45 (33%) who were not given steroids. There were differences between the three cochlear implant groups, with the Med-El and Advanced Bionics groups performing better than the Oticon group (45% and 43% of the former two groups achieved partial or complete HP compared to 20% in the latter). Hearing thresholds in the non-operated ear were stable over 12 months. Generally, impedance was slightly lower in the 12 month follow-up in comparison with the activation period, with the exception of the Oticon group. (4) Conclusions: Pharmacological treatment with steroids in patients undergoing cochlear implantation helps to preserve residual hearing.

12.
PLoS One ; 17(9): e0260739, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36048883

RESUMO

During childhood, neuronal modifications occur so that typical childhood communicative development occurs. This work aims to contribute to the understanding of differences in the speech encoding of infants and school-age children by assessing the effects of child development, in different phases of early childhood, on the encoding of speech sounds. There were 98 subjects of both sexes, aged from 1 day to 8 years and 9 months who participated in the study. All subjects underwent a Frequency Following Response (FFR) assessment. A regression and linear correlation showed the effects of age in the FFR components, i.e., significant decrease in the latency and increased amplitude of all FFR waves with age. An increase in the slope measure was also observed. Younger infants require more time and show less robust responses when encoding speech than their older counterparts, which were shown to have more stable and well-organized FFR responses.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Percepção da Fala , Estimulação Acústica , Criança , Desenvolvimento Infantil , Pré-Escolar , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Feminino , Humanos , Lactente , Masculino , Fonética , Percepção da Fala/fisiologia
13.
Value Health Reg Issues ; 32: 1-7, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35947901

RESUMO

OBJECTIVES: The Dizziness Handicap Inventory (DHI) questionnaire is used to assess the severity of vertigo. In clinical practice, it is a good indicator for understanding the patient's feelings and can be used as a quantitative measure for monitoring ongoing treatment and rehabilitation. This study involved the translation, cultural adaptation, and validation of the Polish DHI questionnaire (DHI-POL). METHODS: We recruited 127 subjects (mean age 55.1 years) who experienced vertigo, dizziness, and imbalance resulting from a disturbance to their vestibular system that had lasted longer than 1 month and 56 subjects (mean age 51.8 years) without any vestibular symptoms. All subjects performed a posturography Sensory Organization Test and completed the questionnaire twice. RESULTS: Cronbach's alpha for the overall DHI-POL was α = 0.93. The questions were divided into 3 subgroups (functional [F], emotional [E], and physical [P]) for which the internal consistency was as follows: DHI-F, α = 0.84; DHI-E, α = 0.85; and DHI-P, α = 0.81. Reproducibility, as measured by interclass correlation coefficient for the overall DHI-POL, was 0.91. For each interclass correlation coefficient subgroup, the results were as follows: DHI-F, 0.90; DHI-E, 0.93; and DHI-P, 0.83. CONCLUSIONS: DHI-POL has a high consistency and repeatability; therefore, it is a fully functional questionnaire that meets all the validation criteria and is a tool ready for use on Polish patients with vertigo.


Assuntos
Comparação Transcultural , Tontura , Humanos , Pessoa de Meia-Idade , Tontura/diagnóstico , Tontura/psicologia , Reprodutibilidade dos Testes , Polônia , Avaliação da Deficiência , Vertigem/diagnóstico , Vertigem/psicologia
14.
Am J Otolaryngol ; 43(5): 103601, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35981433

RESUMO

PURPOSE: After radical surgery for chronic cholesteatoma (CWD mastoidectomy), patients have the option to have the posterior wall of their external auditory canal surgically reconstructed with S53P4 bioactive glass. The procedure eliminates some of the restrictions related to having a postoperative cavity and extends the options for a hearing prosthesis. If classic reconstruction is not possible and a hearing aid is not used, we suggest use of a Bonebridge implant. METHODS: This study describes, over 18 months of follow-up, 16 patients after a two-stage surgical procedure: obliteration of the mastoid cavity with bioactive glass followed by Bonebridge implantation. There were 7 patients who received the first generation implant (BCI 601) and 9 who used the second (BCI 602). Before and after implantation, pure tone audiometry, sound field thresholds, and free-field audiometry were performed. Speech reception thresholds in noise were assessed using the Polish Sentence Matrix Test. Subjective assessment of benefits was done using the APHAB (Abbreviated Profile of Hearing Aid Benefit) questionnaire. RESULTS: During the observation period, no serious complications were found. The study demonstrated the safety and validity of the procedures and confirmed the safety of using S53P4 bioactive glass in otosurgery (antibacterial effect, nonrecurrence of cholesteatoma, and no effect on the inner ear). The audiological benefits expected from using the Bonebridge implant processor were also confirmed. CONCLUSION: It is concluded that, after reconstructing the posterior wall of the external auditory canal with bioactive glass, two-stage implantation of a Bonebridge implant in a typical site is a safe solution for patients who have difficult anatomical conditions following their CWD mastoidectomy.


Assuntos
Colesteatoma , Auxiliares de Audição , Antibacterianos , Audiometria de Tons Puros , Condução Óssea , Colesteatoma/cirurgia , Vidro , Humanos , Processo Mastoide/cirurgia , Mastoidectomia/métodos , Resultado do Tratamento
15.
Front Surg ; 9: 893839, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36034377

RESUMO

Background: The last two decades have demonstrated that preoperative functional acoustic hearing (residual hearing) can be preserved during cochlear implant (CI) surgery. However, the relationship between the electrode array length and postoperative hearing preservation (HP) with lateral wall flexible electrode variants is still under debate. Aims/Objectives: This is a systematic literature review that aims to analyze the HP rates of patients with residual hearing for medium-length and longer-length lateral wall electrodes. Method: A systematic literature review methodology was applied following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) recommendations to evaluate the HP rates of medium-length and longer-length lateral wall electrodes from one CI manufacturer (medium length FLEX 24, longer length FLEX 28 and FLEX SOFT, MED-EL, Innsbruck, Austria). A search using search engine PubMed (https://www.ncbi.nlm.nih.gov/pubmed/) was performed using the search terms "hearing preservation" or "residual hearing" and "cochlear implant" in "All fields." Articles published only in English between January 01, 2009 and December 31, 2020 were included in the search. Results: The HP rate was similar between medium-length (93.4%-93.5%) and longer (92.1%-86.8%) electrodes at 4 months (p = 0.689) and 12 months (p = 0.219). In the medium-length electrode group, patients under the age of 45 years had better HP than patients above the age of 45 years. Conclusions: Both medium-length and longer electrode arrays showed high hearing preservation rates. Considering the hearing deterioration over time, implanting a longer electrode at primary surgery should be considered, thus preventing the need for future reimplantation.

16.
Audiol Res ; 12(3): 224-248, 2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35645195

RESUMO

(1) Background: The purpose of this article is to review pharmacological treatments for COVID-19 (currently approved by the EMA (European Medical Agency) and FDA (Food and Drug Administration)) and highlight their potential audio-vestibular side-effects as an ototoxic adverse reaction. (2) Methods: Review of the available literature in the scientific databases PubMed, ResearchGate, Scopus, and ScienceDirect, and in summaries of product data sheets. (3) Results: In accordance with EBM (evidence-based medicine) the treatment of COVID-19 by using lopinavir/ritonavir, chloroquine and hydroxychloroquine, azithromycin, favipiravir, amantadine, oseltamivir, and ivermectin is no longer recommended for patients suffering from COVID-19 due to a lack of clinical data, publications, and recommendations. There were 39 publications and 15 summaries of product characteristics (as other sources of data) which were also used in this analysis. Adverse events could be permanent or disappear over time. Following treatment for COVID-19, the most frequent adverse audio-vestibular reactions reported in clinical trials and publications in the area of audiology and otorhinolaryngology were: dizziness, blurry vision with dizziness, nasopharyngitis, dysgeusia, and tinnitus. As far as vaccines are concerned, dizziness as an ototoxic effect was uncommon and occurs only in hypersensitive people who experience anaphylactic shock. (4) Conclusions: The ototoxicity of the drugs discussed here does not have as severe symptoms as the drugs used in the treatment of COVID-19 in 2020 (e.g., hydroxychloroquine), and relates mainly to disorders of the vestibulocochlear system. However, there is still a need to monitor ototoxic side-effects because of potential interactions with other ototoxic drugs. Many of the drugs approved by EMA and FDA are new, and not every side-effect is known.

17.
Biomed Phys Eng Express ; 8(5)2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35724632

RESUMO

Transiently evoked otoacoustic emissions (TEOAEs) are routinely used in the hearing assessment of the auditory periphery. The major contribution of TEOAEs is the early detection of hearing losses in neonates, children, and adults. The evaluation of TEOAE responses by specific signal decomposition techniques offers numerous advantages for current and future research. One methodology, based on recurrence quantification analysis (RQA), can identify adult subjects presenting sensorineural hearing impairments. In two previous papers, the RQA-based approach was successfully applied in identifying and classifying cases presenting noise and age related hearing losses. The current work investigates further two aspects of the previously proposed RQA-based analysis for hearing loss detection: (i) the reliability of a Training set built from different numbers of ears with normal hearing, and (ii) the threshold set of values of the key hearing loss detecting parameter RAD2D.Results:The Training set built from 158 healthy ears was found to be quite reliable and a similar but slightly minor performance was observed for the training set of 118 normal subjects, used in the past; the proposed ROC-curve method, optimizing the values of RAD2D, shows improved sensibility and specificity in one class discrimination.Conclusions.A complete and simplified procedure, based on the combined use of the traditional TEOAE reproducibility value and on values from the RQA-based RAD2D parameter, is proposed as an improved automatic classifier, in terms of sensitivity and specificity, for different types of hearing losses.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva , Adulto , Limiar Auditivo/fisiologia , Criança , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Recém-Nascido , Emissões Otoacústicas Espontâneas/fisiologia , Reprodutibilidade dos Testes
18.
Front Surg ; 9: 823219, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402479

RESUMO

Background and Objective: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods: A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results: A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion: Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.

19.
Int. arch. otorhinolaryngol. (Impr.) ; 26(1): 158-166, Jan.-Mar. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1364915

RESUMO

Abstract Introduction Parkinson disease (PD) is a degenerative and progressive neurological disorder characterized by resting tremor, stiffness, bradykinesia, and postural instability. Despite the motor symptoms, PD patients also consistently show cognitive impairment or executive dysfunction. The auditory event-related potential P300 has been described as the best indicator of mental function, being highly dependent on cognitive skills, including attention and discrimination. Objective To review the literature on the application and findings of P300 as an indicator of PD. Data Analysis The samples ranged from 7 to 166 individuals. Young adult and elderly male patients composed most study samples. The Mini-Mental State Examination test, the Unified Parkinson Disease Rating Scale, and the Hoehn and Yahr Scale were used to assess neurological and cognitive function. In terms of testing hearing function, few studies have focused on parameters other than the P300. The factors we focused on were how the P300 was modified by cognitive effects, its correlation with different PD scales, the effect of performing dual tasks, the effect of fatigue, and the influence of drug treatments. Conclusion The use of the P300 appears to be an effective assessment tool in patients with PD. This event-related potential seems to correlate well with other neurocognitive tests that measure key features of the disease.

20.
Life (Basel) ; 12(2)2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35207425

RESUMO

The Bonebridge implant can be a satisfactory solution for patients with conductive or mixed hearing loss (CHL or MHL), or with single-sided deafness (SSD). The aim of the study was to assess patients' self-reported benefits with the Bonebridge and characterize the relationships between pre-implantation audiometric data, auditory functioning, and satisfaction after implantation. A focus was to see whether different types of hearing loss were associated with particular benefits. The study sample consisted of 81 patients. Procedures comprised pure tone audiometry before implantation, the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire, and a structured interview asking about satisfaction. Statistically significant improvements after implantation were found in all groups (CHL, MHL, SSD) on the APHAB questionnaire. In the structured interview, patients with SSD were the least satisfied. No significant correlation was found between pre-operative air-bone gap and bone conduction thresholds or with APHAB score. Bonebridge implantation is beneficial to patients with CHL or MHL, or with SSD. Assessment of patients for Bonebridge implantation is complex, and audiometric data should be complemented by patient-reported outcomes to provide deeper insight into their individual needs and attitudes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...