Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Respirol Case Rep ; 8(2): e00517, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32042428

RESUMO

The use of the endobronchial ultrasound (EBUS) endoscope in the oesophagus, the so-called EUS-B procedure, for the diagnosis and staging of thoracic malignancy is quickly gaining ground. Pleural lesions located close to the oesophagus can be inaccessible to transthoracic biopsy and endoscopic procedures can be the only option. We here present two cases demonstrating that EUS-B-guided fine needle aspiration (EUS-B-FNA) of pleural lesions is possible. The first case demonstrates a EUS-B-FNA with malignant mesothelioma of a pleural lesion in a 70-year-old patient. In the second case, EUS-B-FNA diagnosed a pleural metastasis from adenoid cystic adenocarcinoma in a 75-year-old-patient. In conclusion, we hereby demonstrate that EUS-B-FNA from pleural lesions is feasible and appears to be safe.

2.
Respiration ; 97(4): 277-283, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30253411

RESUMO

BACKGROUND: Diagnosing centrally located lung tumors without endobronchial abnormalities and not located near the major airways is a diagnostic challenge. Tumors near or adjacent to the esophagus can be aspirated and detected with esophageal ultrasound (EUS) using gastrointestinal endoscopes. OBJECTIVE: To assess the feasibility and diagnostic yield of endoscopic ultrasound with bronchoscope-guided fine needle aspiration (EUS-B-FNA) in paraesophageally located lung tumors and its added value to bronchoscopy and endobronchial ultrasound (EBUS). METHODS: Retrospective, multicenter international study (from January 1, 2015 until January 1, 2018) of patients with suspected lung cancer, undergoing bronchoscopy, EBUS, and endoscopic ultrasound bronchoscopy (EUS-B) in one session by a single operator (pulmonologist), in whom the primary lung tumor was detected and aspirated by EUS-B. In the absence of malignancy following endoscopy, transthoracic ultrasound needle aspiration, clinical and radiological follow-up of at least 6 months was performed. The yield and sensitivity of EUS-B-FNA and its added value to bronchoscopy and EBUS was assessed. RESULTS: 58 patients were identified with the following diagnosis: non-small-cell lung cancer (n = 43), small-cell lung cancer (n = 6), mesothelioma (n = 2), metastasis (n = 1), nonmalignant (n = 6). The yield and sensitivity of EUS-B-FNA for detecting lung cancer was 90%. In 26 patients (45%), the intrapulmonary tumor was exclusively detected by EUS-B. Adding EUS-B to conventional bronchoscopy and EBUS increased the diagnostic yield for diagnosing lung cancer in para-esophageally located lung tumors from 51 to 91%. No EUS-B-related complications were observed. CONCLUSION: EUS-B-FNA is a feasible and safe technique for diagnosing centrally located intrapulmonary tumors that are located near or adjacent to the esophagus. EUS-B should be considered in the same endoscopy session following nondiagnostic bronchoscopy and EBUS.


Assuntos
Adenocarcinoma/diagnóstico , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pulmonares/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...