Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32792285

RESUMO

INTRODUCTION: Since arthroscopy remains a controversial treatment of hip dysplasia, our objective was to analyse its clinical and radiological results in a cohort of patients with dysplasia and compare them to controls with femoroacetabular impingement (FAI). MATERIAL AND METHODS: We retrospectively analysed a series of patients who underwent hip arthroscopy for the treatment of labral pathology; 29 of them with borderline hip dysplasia and 197 with FAI, comparing reoperations and joint survival. The diagnosis of borderline dysplasia was made with a lateral centre-edge angle greater than 18° but less than 25°. The average follow-up was 43 months. We performed a multivariate regression analysis to evaluate the association of reoperations with different demographic, radiological and intraoperative variables. RESULTS: Seven complications were registered in the FAI group (1 medically treated superficial wound infection, 3 pudendal nerve paraesthesias, 1 deep vein thrombosis and 2 heterotopic ossifications) and none in the dysplasia group. While 5 patients from the FAI group required a new surgery, none of the dysplasia group was re-operated (p=.38). After adjusting for confounders, reoperation showed a very strong association with the finding of osteochondral lesions during index surgery, with a coefficient of .12 (p<.001, 95%CI=.06-.17). CONCLUSION: Hip arthroscopy was useful in the treatment of borderline dysplasia, without non-inferior survival compared to the FAI group. We suggest indicating it carefully in dysplasia cases, whenever the symptoms of femoroacetabular friction prevail over those of instability.


Assuntos
Artroscopia , Impacto Femoroacetabular/cirurgia , Luxação do Quadril/cirurgia , Adulto , Estudos de Casos e Controles , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Luxação do Quadril/diagnóstico por imagem , Humanos , Masculino , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
2.
Orthop Traumatol Surg Res ; 104(4): 439-443, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29581066

RESUMO

BACKGROUND: Although there is some clinical evidence of ceramic bearings being associated with a lower infection rate after total hip arthroplasty (THA), available data remains controversial since this surface is usually reserved for young, healthy patients. Therefore, we investigated the influence of five commonly used biomaterials on the adhesion potential of four biofilm-producing bacteria usually detected in infected THAs. HYPOTHESIS: Ceramic biomaterials exhibit less bacterial adherence than other biomaterials. MATERIAL AND METHODS: In this in vitro research, we evaluated the ability of Staphylococcus aureus, Staphylococcus epidermidis ATCC 35984, Escherichia coli ATCC 25922 and Pseudomonas aeruginosa to adhere to the surface of a cobalt-chromium metal head, a fourth-generation ceramic head, a fourth-generation ceramic insert, a highly-crossed linked polyethylene insert and a titanium porous-coated acetabular component. After an initial washing step, bacterial separation from the surface of each specimen was done with a vortex agitator. The colony-forming units were counted to determine the number of viable adherent bacteria. RESULTS: We found no differences on global bacterial adhesion between the different surfaces (p=0.5). E. coli presented the least adherence potential among the analysed pathogens (p<0.001). The combination of E. coli and S. epidermidis generated an antagonist effect over the adherence potential of S. epidermidis individually (58±4% vs. 48±5%; p=0.007). The combination of P. aeruginosa and S. aureus presented a trend to an increased adherence of P. aeruginosa independently, suggesting an agonist effect (71% vs. 62%; p=0.07). DISCUSSION: Ceramic bearings appeared not to be related to a lower bacterial adhesion than other biomaterials. However, different adhesive potentials among bacteria may play a major role on infection's inception. LEVEL OF EVIDENCE: IV, in vitro study.


Assuntos
Aderência Bacteriana , Materiais Biocompatíveis , Cerâmica , Metais , Polietileno , Antibiose , Cromo , Cobalto , Escherichia coli/fisiologia , Prótese Articular/microbiologia , Pseudomonas aeruginosa/fisiologia , Staphylococcus aureus/fisiologia , Staphylococcus epidermidis/fisiologia , Simbiose , Titânio
3.
Bone Joint J ; 99-B(11): 1435-1441, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29092981

RESUMO

AIMS: The Corail stem has good long-term results. After four years of using this stem, we have detected a small group of patients who have presented with symptomatic metaphyseal debonding. The aim of this study was to quantify the incidence of this complication, to delineate the characteristics of patients presenting with this complication and to compare these patients with asymptomatic controls to determine any important predisposing factors. PATIENTS AND METHODS: Of 855 Corail collarless cementless stems implanted for osteoarthritis, 18 presented with symptomatic metaphyseal debonding. A control group of 74 randomly selected patients was assembled. Clinical and radiological parameters were measured and a logistic regression model was created to evaluate factors associated with metaphyseal debonding. RESULTS: The prevalence of this complication was 2.1% in our series. In the multivariable model, the presence of a Dorr B-type proximal femur was associated with metaphyseal debonding (odds ratio (OR) 10.73, 95% confidence interval (CI) 2.31 to 49.97, p = 0.002), as was a body mass index > 25 kg/m2 (OR 6.85, 95% CI 1.06 to 44.28, p = 0.04). Smaller stems and the use of a polyethylene acetabular liner appeared to be protective when compared with metal and ceramic setting hard-on-hard bearings. CONCLUSION: We have described an uncommon but important mode of failure of the Corail stem. Surgeons should be aware of this phenomenon; overweight patients with Dorr B-type femurs and in whom hard bearings are used appear to be particularly at risk. Cite this article: Bone Joint J 2017;99-B:1435-41.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Falha de Prótese/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Orthopade ; 46(4): 359-365, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27832317

RESUMO

INTRODUCTION: To determine the effects of tranexamic acid (TXA) on transfusions in patients undergoing hip replacement with a hybrid or cementless prosthesis. METHODS: A group of 172 consecutive patients aged 18 years or older who underwent elective hip replacement with uncemented or hybrid prostheses, undergoing surgery between January 2012 and January 2014 by the same primary surgeon and anesthesiologist, were retrospectively included. TXA (1 g) was administered immediately before incision in the TXA group. Primary variables included number of red blood cell transfusions and the influence of TXA for each type of prosthesis. Secondary variables included hematocrit at discharge, length of hospital stay, thrombosis or pulmonary embolism, seizures, and death. RESULTS: Average transfusion was 1.53 units/patient in the control group compared to 0.6 units/patient in the TXA group (z = 6.29; U = 1640.5; p < 0.0001). TXA use was significantly correlated with the number of units transfused (p < 0.0001, 95% CI -1.24 to -0.68). Odds risk reduction for transfusion was observed during surgery (OR: 0.14; CI 0.06-0.29; p < 0.0001) and during the rest of hospital stay (OR: 0.11; CI 0.01-0.96; p = 0.046). Both hybrid and cementless prostheses that received TXA were transfused less than control groups (0.57 ± 1 vs. 1.7 ± 1 p < 0.01 and 0.65 ± 1 vs. 1.24 ± 1 p < 0.01). No difference was observed between the groups regarding adverse effects. Hematocrit values at discharge and length of hospital stay were similar between groups. No deaths were observed during hospital stay. CONCLUSIONS: TXA reduced transfusions without increasing the prevalence of adverse effects. This reduction was observed during surgery and the following days of hospital stay for both for hybrid and cementless prosthesis.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Ácido Tranexâmico/administração & dosagem , Idoso , Antifibrinolíticos/administração & dosagem , Argentina/epidemiologia , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Causalidade , Estudos de Coortes , Comorbidade , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Prevalência , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Bone Joint J ; 96-B(4): 530-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24692623

RESUMO

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment. We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction.


Assuntos
Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Olécrano/lesões , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Moldes Cirúrgicos , Articulação do Cotovelo/fisiopatologia , Feminino , Fixação de Fratura/efeitos adversos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/reabilitação , Humanos , Masculino , Olécrano/diagnóstico por imagem , Satisfação do Paciente , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Lesões no Cotovelo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA