Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
Invest Radiol ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38265058

RESUMO

OBJECTIVES: The Centers for Medicare and Medicaid Services funded the development of a computed tomography (CT) quality measure for use in pay-for-performance programs, which balances automated assessments of radiation dose with image quality to incentivize dose reduction without compromising the diagnostic utility of the tests. However, no existing quantitative method for assessing CT image quality has been validated against radiologists' image quality assessments on a large number of CT examinations. Thus to develop an automated measure of image quality, we tested the relationship between radiologists' subjective ratings of image quality with measurements of radiation dose and image noise. MATERIALS AND METHODS: Board-certified, posttraining, clinically active radiologists rated the image quality of 200 diagnostic CT examinations from a set of 734, representing 14 CT categories. Examinations with significant distractions, motion, or artifact were excluded. Radiologists rated diagnostic image quality as excellent, adequate, marginally acceptable, or poor; the latter 2 were considered unacceptable for rendering diagnoses. We quantified the relationship between ratings and image noise and radiation dose, by category, by analyzing the odds of an acceptable rating per standard deviation (SD) increase in noise or geometric SD (gSD) in dose. RESULTS: One hundred twenty-five radiologists contributed 24,800 ratings. Most (89%) were acceptable. The odds of an examination being rated acceptable statistically significantly increased per gSD increase in dose and decreased per SD increase in noise for most categories, including routine dose head, chest, and abdomen-pelvis, which together comprise 60% of examinations performed in routine practice. For routine dose abdomen-pelvis, the most common category, each gSD increase in dose raised the odds of an acceptable rating (2.33; 95% confidence interval, 1.98-3.24), whereas each SD increase in noise decreased the odds (0.90; 0.79-0.99). For only 2 CT categories, high-dose head and neck/cervical spine, neither dose nor noise was associated with ratings. CONCLUSIONS: Radiation dose and image noise correlate with radiologists' image quality assessments for most CT categories, making them suitable as automated metrics in quality programs incentivizing reduction of excessive radiation doses.

2.
Eur Radiol ; 34(4): 2394-2404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37735276

RESUMO

OBJECTIVE: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. METHODS: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. RESULTS: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6-40%. CONCLUSION: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Abdome
3.
Eur Radiol ; 34(3): 1605-1613, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37646805

RESUMO

OBJECTIVE: Quantify the relationship between CT acquisition parameters and radiation dose, how often parameters are adjusted in real-world practice, and their degree of contribution to real-world dose distribution. Identify discrepancies between parameters that are impactful in theory and impactful in practice. METHODS: This study analyses 1.3 million consecutive adult routine abdomen exams performed between November 2015 and Jan 2021 included in the University of California, San Francisco International CT Dose Registry of 155 institutions. We calculated geometric standard deviation (gSD) for five parameters (kV, mAs, spiral pitch, number of phases, scan length) to assess variation in practice. A Gaussian mixed regression model was performed to predict the radiation dose-length product (DLP) using the parameters. Three conceptualizations of "impact" were computed for each parameter. To reflect the theoretical impact, we predict the increase in DLP per 10% (and 15%) increase in the parameter. To reflect the real-world practical impact, we predict the increase in DLP per gSD increase in the parameter. RESULTS: Among studied examinations, mAs, number of phases, and scan length were frequently manipulated (gSD 1.52-1.70); kV was rarely manipulated (gSD 1.07). Theoretically, kV is the most impactful parameter (29% increase in DLP per 10% increase in kV, versus 5-9% increase for other parameters). In real-world practice, kV is less impactful; for each gSD increase in kV, the DLP increases by 20%, versus 22-69% for other parameters. CONCLUSION: Despite the potential impact of kV on radiation dose, this parameter is rarely manipulated in common practice and this potential remains untapped. CLINICAL RELEVANCE STATEMENT: CT beam energy (kV) modulation has the potential to strongly reduce radiation over-dosage to the patient, theoretically more so than similar degrees of modulation in other CT acquisition parameters. Despite this, beam energy modulation rarely occurs in practice, leaving its potential untapped. KEY POINTS: • The relationship between CT acquisition parameter selection and radiation dose roughly coincided with established theoretical understanding. • CT acquisition parameters differ from each other in frequency and magnitude of manipulation, with beam energy (kV) being rarely manipulated. • Beam energy (kV) has the potential to substantially impact radiation dose, but because it is rarely manipulated, it is the least impactful CT acquisition parameter affecting radiation dose in practice.


Assuntos
Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação
4.
Eur Radiol ; 34(4): 2416-2425, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37798408

RESUMO

OBJECTIVES: The most accurate method for estimating patient effective dose (a principal metric for tracking patient radiation exposure) from computed tomography (CT) requires time-intensive Monte Carlo simulation. A simpler method multiplies a scalar coefficient by the widely available scanner-reported dose length product (DLP) to estimate effective dose. We developed new adult effective dose coefficients using actual patient scans and assessed their agreement with Monte Carlo simulation. METHODS: A multicenter sample of 216,906 adult CT scans was prospectively assembled in 2015-2020 from the University of California San Francisco International CT Dose Registry and the University of Florida library of computational phantoms. We generated effective dose coefficients for eight body regions, stratified by patient sex, diameter, and scanner manufacturer. We applied the new coefficients to DLPs to calculate effective doses and assess their correlations with Monte Carlo radiation transport-generated effective dose. RESULTS: Effective dose coefficients varied by body region and decreased in magnitude with increasing patient diameter. Coefficients were approximately twofold higher for torso scans in smallest compared with largest diameter categories. For example, abdomen and pelvis coefficients decreased from 0.027 to 0.013 mSv/mGy-cm between the 16-20 cm and 41+ cm categories. There were modest but consistent differences by sex and manufacturer. Diameter-based coefficients used to estimate effective dose produced strong correlations with the reference standard (Pearson correlations 0.77-0.86). The reported conversion coefficients differ from previous studies, particularly in neck CT. CONCLUSIONS: New effective dose coefficients derived from empirical clinical scans can be used to easily estimate effective dose using scanner-reported DLP. CLINICAL RELEVANCE STATEMENT: Scalar coefficients multiplied by DLP offer a simple approximation to effective dose, a key radiation dose metric. New effective dose coefficients from this study strongly correlate with gold standard, Monte Carlo-generated effective dose, and differ somewhat from previous studies. KEY POINTS: • Previous effective dose coefficients were derived from theoretical models rather than real patient data. • The new coefficients (from a large registry/phantom library) differ from previous studies. • The new coefficients offer reasonably reliable values for estimating effective dose.


Assuntos
Modelos Teóricos , Radiometria , Adulto , Humanos , Simulação por Computador , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Masculino , Feminino
6.
PLoS One ; 18(9): e0289957, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37672503

RESUMO

OBJECTIVE: To evaluate the frequency of medical imaging or estimated associated radiation exposure in children with Down syndrome. METHODS: This retrospective cohort study included 4,348,226 children enrolled in six U.S. integrated healthcare systems from 1996-2016, 3,095 of whom were diagnosed with Down syndrome. We calculated imaging rates per 100 person years and associated red bone marrow dose (mGy). Relative rates (RR) of imaging in children with versus without Down syndrome were estimated using overdispersed Poisson regression. RESULTS: Compared to other children, children with Down syndrome received imaging using ionizing radiation at 9.5 times (95% confidence interval[CI] = 8.2-10.9) the rate when age <1 year and 2.3 times (95% CI = 2.0-2.5) between ages 1-18 years. Imaging rates by modality in children <1 year with Down syndrome compared with other children were: computed tomography (6.6 vs. 2.0, RR = 3.1[95%CI = 1.8-5.1]), fluoroscopy (37.1 vs. 3.1, RR 11.9[95%CI 9.5-14.8]), angiography (7.6 vs. 0.2, RR = 35.8[95%CI = 20.6-62.2]), nuclear medicine (6.0 vs. 0.6, RR = 8.2[95% CI = 5.3-12.7]), radiography (419.7 vs. 36.9, RR = 11.3[95%CI = 10.0-12.9], magnetic resonance imaging(7.3 vs. 1.5, RR = 4.2[95% CI = 3.1-5.8]), and ultrasound (231.2 vs. 16.4, RR = 12.6[95% CI = 9.9-15.9]). Mean cumulative red bone marrow dose from imaging over a mean of 4.2 years was 2-fold higher in children with Down syndrome compared with other children (4.7 vs. 1.9mGy). CONCLUSIONS: Children with Down syndrome experienced more medical imaging and higher radiation exposure than other children, especially at young ages when they are more vulnerable to radiation. Clinicians should consider incorporating strategic management decisions when imaging this high-risk population.


Assuntos
Síndrome de Down , Exposição à Radiação , Criança , Humanos , Lactente , Síndrome de Down/diagnóstico por imagem , Estudos Retrospectivos , Radiografia , Tomografia Computadorizada por Raios X/efeitos adversos , Exposição à Radiação/efeitos adversos
7.
Pulm Circ ; 13(3): e12282, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37614831

RESUMO

Pediatric patients with pulmonary hypertension (PH) receive imaging studies that use ionizing radiation (radiation) such as computed tomography (CT) and cardiac catheterization to guide clinical care. Radiation exposure is associated with increased cancer risk. It is unknown how much radiation pediatric PH patients receive. The objective of this study is to quantify radiation received from imaging and compute associated lifetime cancer risks for pediatric patients with PH. Electronic health records between 2012 and 2022 were reviewed and radiation dose data were extracted. Organ doses were estimated using Monte Carlo modeling. Cancer risks for each patient were calculated from accumulated exposures using National Cancer Institute tools. Two hundred and forty-nine patients with PH comprised the study cohort; 97% of patients had pulmonary arterial hypertension, PH due to left heart disease, or PH due to chronic lung disease. Mean age at the time of the first imaging study was 2.5 years (standard deviation [SD] = 4.9 years). Patients underwent a mean of 12 studies per patient per year, SD = 32. Most (90%) exams were done in children <5 years of age. Radiation from CT and cardiac catheterization accounted for 88% of the total radiation dose received. Cumulative mean effective dose was 19 mSv per patient (SD = 30). Radiation dose exposure resulted in a mean increased estimated lifetime cancer risk of 7.6% (90% uncertainty interval 3.0%-14.2%) in females and 2.8% (1.2%-5.3%) in males. Careful consideration for the need of radiation-based imaging studies is warranted, especially in the youngest of children.

9.
Chest ; 164(6): 1560-1571, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37356710

RESUMO

BACKGROUND: Anxiety and emotional distress have not been studied in large, diverse samples of patients with pulmonary nodules. RESEARCH QUESTION: How common are anxiety and distress in patients with newly identified pulmonary nodules, and what factors are associated with these outcomes? STUDY DESIGN AND METHODS: This study surveyed participants in the Watch the Spot Trial, a large, pragmatic clinical trial of more vs less intensive strategies for radiographic surveillance of patients with small pulmonary nodules. The survey included validated instruments to measure patient-centered outcomes such as nodule-related emotional distress (Impact of Event Scale-Revised) and anxiety (Six-Item State Anxiety Inventory) 6 to 8 weeks following nodule identification. Mixed-effects models were used to compare outcomes between study arms following adjustment for potential confounders and clustering within enrollment site, while also examining a limited number of prespecified explanatory factors, including nodule size, mode of detection, type of ordering clinician, and lack of timely notification prior to contact by the study team. RESULTS: The trial enrolled 34,699 patients; 2,049 individuals completed the baseline survey (5.9%). Respondents and nonrespondents had similar demographic and nodule characteristics, although more respondents were non-Hispanic and White. Impact of Event Scale-Revised scores indicated mild, moderate, or severe distress in 32.2%, 9.4%, and 7.2% of respondents, respectively, with no difference in scores between study arms. Following adjustment, greater emotional distress was associated with larger nodule size and lack of timely notification by a clinician; distress was also associated with younger age, female sex, ever smoking, Black race, and Hispanic ethnicity. Anxiety was associated with lack of timely notification, ever smoking, and female sex. INTERPRETATION: Almost one-half of respondents experienced emotional distress 6 to 8 weeks following pulmonary nodule identification. Strategies are needed to mitigate the burden of distress, especially in younger, female, ever smoking, and minoritized patients, and those with larger nodules. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT02623712; URL: www. CLINICALTRIALS: gov.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Angústia Psicológica , Humanos , Feminino , Neoplasias Pulmonares/diagnóstico , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/psicologia , Ansiedade/epidemiologia , Nível de Saúde
10.
Pediatr Radiol ; 53(8): 1659-1668, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36922419

RESUMO

BACKGROUND: The most accurate method for estimating effective dose (the most widely understood metric for tracking patient radiation exposure) from computed tomography (CT) requires time-intensive Monte Carlo simulation. A simpler method multiplies a scalar coefficient by the widely available scanner-reported dose length product (DLP) to estimate effective dose. OBJECTIVE: Develop pediatric effective dose coefficients and assess their agreement with Monte Carlo simulation. MATERIALS AND METHODS: Multicenter, population-based sample of 128,397 pediatric diagnostic CT scans prospectively assembled in 2015-2020 from the University of California San Francisco International CT Dose Registry and the University of Florida library of highly realistic hybrid computational phantoms. We generated effective dose coefficients for seven body regions, stratified by patient age, diameter, and scanner manufacturer. We applied the new coefficients to DLPs to calculate effective doses and assessed their correlations with Monte Carlo radiation transport-generated effective doses. RESULTS: The reported effective dose coefficients, generally higher than previous studies, varied by body region and decreased in magnitude with increasing age. Coefficients were approximately 4 to 13-fold higher (across body regions) for patients <1 year old compared with patients 15-21 years old. For example, head CT (54% of scans) dose coefficients decreased from 0.039 to 0.003 mSv/mGy-cm in patients <1 year old vs. 15-21 years old. There were minimal differences by manufacturer. Using age-based conversion coefficients to estimate effective dose produced moderate to strong correlations with Monte Carlo results (Pearson correlations 0.52-0.80 across body regions). CONCLUSIONS: New pediatric effective dose coefficients update existing literature and can be used to easily estimate effective dose using scanner-reported DLP.


Assuntos
Radiometria , Tomografia Computadorizada por Raios X , Lactente , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Imagens de Fantasmas , Método de Monte Carlo
11.
Chest ; 163(3): 719-730, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36191633

RESUMO

BACKGROUND: Pulmonary nodules are a common incidental finding on CT imaging. Few studies have described patient and nodule characteristics associated with a lung cancer diagnosis using a population-based cohort. RESEARCH QUESTION: Does a relationship exist between patient and nodule characteristics and lung cancer among individuals with incidentally detected pulmonary nodules, and can this information be used to create exploratory lung cancer prediction models with reasonable performance characteristics? STUDY DESIGN AND METHODS: We conducted a retrospective cohort study of adults older than 18 years with lung nodules of any size incidentally detected by chest CT imaging between 2005 and 2015. All patients had at least 2 years of complete follow-up. To evaluate the relationship between patient and nodule characteristics and lung cancer, we used binomial regression. We used logistic regression to create prediction models, and we internally validated model performance using bootstrap optimism correction. RESULTS: Among 7,240 patients with a median age of 67 years, 56% of whom were women, with a median BMI of 28 kg/m2, 56% of whom were ever smokers, 31% of whom had prior nonlung malignancy, with a median nodule size 5.6 mm, 57% of whom had multiple nodules, and 40% of whom had an upper lobe nodule, 265 patients (3.7%; 95% CI, 3.2%-4.1%) had a diagnosis of lung cancer. In a multivariate analysis, age, sex, BMI, smoking history, and nodule size and location were associated with a lung cancer diagnosis, whereas prior malignancy and nodule number and laterality were not. We were able to construct two prediction models with an area under the curve value of 0.75 (95% CI, 0.72-0.80) and reasonable calibration. INTERPRETATION: Lung cancer is uncommon among individuals with incidentally detected lung nodules. Some, but not all, previously identified factors associated with lung cancer also were associated with this outcome in this sample. These findings may have implications for clinical practice, future practice guidelines, and the development of novel lung cancer prediction models for individuals with incidentally detected lung nodules.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Adulto , Humanos , Feminino , Idoso , Masculino , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Pulmão/patologia , Nódulos Pulmonares Múltiplos/patologia
13.
J Am Coll Radiol ; 19(11): 1226-1235, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36049538

RESUMO

PURPOSE: The Fleischner Society aims to limit further evaluations of incidentally detected pulmonary nodules when the probability of lung cancer is <1% and to pursue further evaluations when the probability of lung cancer is ≥1%. To evaluate the internal consistency of guideline goals and recommendations, the authors evaluated stratum-specific recommendations and 2-year probabilities of lung cancer. METHODS: A retrospective cohort study (2005-2015) was conducted of individuals enrolled in one of two integrated health systems with solid nodules incidentally detected on CT. The 2017 Fleischner Society guidelines were used to define strata on the basis of smoking status and nodule size and number. Lung cancer diagnoses within 2 years of nodule detection were ascertained using cancer registry data. Confidence interval (CI) inspection was used to determine if stratum-specific probabilities of lung cancer were different than 1%. RESULTS: Among 5,444 individuals with incidentally detected lung nodules (median age, 66 years; 54% women; 57% smoked; median nodule size, 5.5 mm; 55% with multiple nodules), 214 (3.9%; 95% CI, 3.4%-4.5%) were diagnosed with lung cancer within 2 years. For 7 of 12 strata (58%), 2,765 patients (51%), and 194 lung cancer cases (91%), there was alignment between Fleischner Society goals and recommendations. Alignment was indeterminate for 5 strata (42%), 2,679 patients (49%), and 20 lung cancer cases (9%) because CIs for the probability of lung cancer spanned 1%. CONCLUSIONS: Fleischner Society guideline goals and recommendations align at least half the time. It is uncertain whether alignment of guideline goals and recommendations occurs more often.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Feminino , Idoso , Masculino , Nódulo Pulmonar Solitário/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/epidemiologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Probabilidade , Achados Incidentais
14.
Am J Emerg Med ; 60: 164-170, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35986979

RESUMO

INTRODUCTION: Previously, we found that the use of ultrasonography for patients with suspected nephrolithiasis resulted in similar outcomes and less radiation exposure vs. CT scan. In this study, we evaluated the implementation of an ultrasound-first clinical decision support (CDS) tool in patients with suspected nephrolithiasis. METHODS: This randomized trial was conducted at an academic emergency department (ED). We implemented the ultrasound-first CDS tool, deployed when an ED provider placed a CT order for suspected nephrolithiasis. Providers were randomized to receiving the CDS tool vs. usual care. The primary outcome was receipt of CT during the index ED visit. Secondary outcomes included radiation dose and ED revisit. RESULTS: 64 ED Providers and 254 patients with suspected nephrolithiasis were enrolled from January 2019 through Dec 2020. The US-First CDS tool was deployed for 128 patients and was not deployed for 126 patients. 86.7% of patients in the CDS arm received a CT vs. 94.4% in the usual care arm, resulting in an absolute risk difference of -7.7% (-14.8 to -0.6%). Mean radiation dose in the CDS arm was 6.8 mSv (95% CI 5.7-7.9 mSv) vs. 6.1 mSv (95% CI 5.1-7.1 mSv) in the usual care arm. The CDS arm did not result in increased ED revisits, CT scans, or hospitalizations at 7 or 30 days. CONCLUSIONS AND RELEVANCE: Implementation of the US-first CDS tool resulted in lower CT use for ED patients with suspected nephrolithiasis. The use of this decision support may improve the evaluation of a common problem in the ED. TRIAL REGISTRATION: ClinicalTrials.gov#NCT03461536.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Cálculos Renais , Serviço Hospitalar de Emergência , Humanos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia
16.
J Am Coll Radiol ; 19(4): 534-541, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35227651

RESUMO

BACKGROUND: Advances in CT have facilitated widespread use of medical imaging while increasing patient lifetime exposure to ionizing radiation. PURPOSE: To describe dose optimization strategies used by health care organizations to optimize radiation dose and image quality. MATERIALS AND METHODS: A qualitative study of semistructured interviews conducted with 26 leaders from 19 health care systems in the United States, Europe, and Japan. Interviews focused on strategies that were used to optimize radiation dose at the organizational level. A directed content analysis approach was used in data analysis. RESULTS: Analysis identified seven organizational strategies used by these leaders for optimizing CT dose: (1) engaging radiologists and technologists, (2) establishing a CT dose committee, (3) managing organizational change, (4) providing leadership and support, (5) monitoring and benchmarking, (6) modifying CT protocols, and (7) changes in equipment and work rules. CONCLUSIONS: Leaders in these health systems engaged in specific strategies to optimize CT dose within their organizations. The strategies address challenges health systems encounter in optimizing CT dose at the organizational level and offer an evolving framework for consideration in dose optimization efforts for enhancing safety and use of medical imaging.


Assuntos
Atenção à Saúde , Liderança , Diagnóstico por Imagem , Europa (Continente) , Humanos , Inovação Organizacional , Estados Unidos
18.
J Gen Intern Med ; 37(10): 2526-2532, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35112281

RESUMO

BACKGROUND: Risk of ovarian cancer in women with frequent perineal talcum powder product is not well understood. Prior systematic reviews focused on ever use. The purpose of this study is to estimate the association between frequent (at least 2 times per week) perineal talcum powder use and ovarian cancer. METHODS: A systematic review and meta-analysis was conducted according to meta-analysis of observational studies in epidemiology guidelines. Study protocol was prospectively registered at PROSPERO (registration number CRD42020172720). Searches were performed in PubMed, Embase, Web of Science, and Cochrane Central Register of Controlled Trials databases from their inception to August 2, 2021. Case-control and cohort studies were included if they reported frequent perineal talcum powder use and an adjusted odds ratio or hazard ratio for ovarian cancer. Review for inclusion, data extraction, and quality assessment (using the Newcastle-Ottawa Scale [NOS]) were performed independently by two reviewers. Pooled adjusted odds ratios with 95% confidence intervals were generated from the random effects model. Heterogeneity was quantified with I2 statistic. Funnel plot and Eger's test were performed to assess publication bias. Subgroup and sensitivity analyses were performed for testing the robustness of the overall findings. RESULTS: Initial database searches returned 761 unique citations and after review, eleven studies describing 66,876 patients, and 6542 cancers were included (Cohen's κ = 0.88). Publication quality was high (median NOS = 8, range: 4 to 9). Frequent talcum powder use was associated with an elevated risk of ovarian cancer (adjusted pooled summary odds ratio 1.47 (95% CI 1.31, 1.65, P<0.0001). There was no evidence of bias and low heterogeneity (I2= 24%, P=0.22). There was no meaningful difference limiting analysis to publications with a NOS quality score of 8 or 9 or limiting studies based on study design. CONCLUSIONS: This review suggests an increased risk of ovarian cancer associated with frequent perineal powder exposure of 31-65%.


Assuntos
Neoplasias Ovarianas , Talco , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Razão de Chances , Neoplasias Ovarianas/induzido quimicamente , Neoplasias Ovarianas/epidemiologia , Talco/efeitos adversos
19.
Cancer Causes Control ; 33(5): 711-726, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35107724

RESUMO

PURPOSE: The Risk of Pediatric and Adolescent Cancer Associated with Medical Imaging (RIC) Study is quantifying the association between cumulative radiation exposure from fetal and/or childhood medical imaging and subsequent cancer risk. This manuscript describes the study cohorts and research methods. METHODS: The RIC Study is a longitudinal study of children in two retrospective cohorts from 6 U.S. healthcare systems and from Ontario, Canada over the period 1995-2017. The fetal-exposure cohort includes children whose mothers were enrolled in the healthcare system during their entire pregnancy and followed to age 20. The childhood-exposure cohort includes children born into the system and followed while continuously enrolled. Imaging utilization was determined using administrative data. Computed tomography (CT) parameters were collected to estimate individualized patient organ dosimetry. Organ dose libraries for average exposures were constructed for radiography, fluoroscopy, and angiography, while diagnostic radiopharmaceutical biokinetic models were applied to estimate organ doses received in nuclear medicine procedures. Cancers were ascertained from local and state/provincial cancer registry linkages. RESULTS: The fetal-exposure cohort includes 3,474,000 children among whom 6,606 cancers (2394 leukemias) were diagnosed over 37,659,582 person-years; 0.5% had in utero exposure to CT, 4.0% radiography, 0.5% fluoroscopy, 0.04% angiography, 0.2% nuclear medicine. The childhood-exposure cohort includes 3,724,632 children in whom 6,358 cancers (2,372 leukemias) were diagnosed over 36,190,027 person-years; 5.9% were exposed to CT, 61.1% radiography, 6.0% fluoroscopy, 0.4% angiography, 1.5% nuclear medicine. CONCLUSION: The RIC Study is poised to be the largest study addressing risk of childhood and adolescent cancer associated with ionizing radiation from medical imaging, estimated with individualized patient organ dosimetry.


Assuntos
Leucemia , Adolescente , Adulto , Criança , Feminino , Humanos , Estudos Longitudinais , Ontário/epidemiologia , Gravidez , Radiografia , Estudos Retrospectivos , Adulto Jovem
20.
Eur Radiol ; 32(3): 1971-1982, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34642811

RESUMO

OB JECTIVES: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. METHODS: Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. RESULTS: The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. CONCLUSIONS: DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. KEY POINTS: • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Níveis de Referência de Diagnóstico , Humanos , Doses de Radiação , Valores de Referência , Sistema de Registros , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...