Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Ned Tijdschr Geneeskd ; 1682024 Jun 05.
Artigo em Holandês | MEDLINE | ID: mdl-38888409

RESUMO

A 38-year-old woman with urosepsis and persistent unilateral hydronephrosis after antibiotic treatment. Antegrade pyelogram shows urine flow obstruction to the bladder. The whole ureter shows multiple small smooth-walled round lucent filling defects projecting into the lumen. The diagnosis ureteritis cystica was made.


Assuntos
Hidronefrose , Humanos , Feminino , Hidronefrose/etiologia , Hidronefrose/diagnóstico , Adulto , Infecções Urinárias/diagnóstico , Infecções Urinárias/complicações , Infecções Urinárias/tratamento farmacológico , Antibacterianos/uso terapêutico , Doenças Ureterais/diagnóstico , Doenças Ureterais/complicações
2.
PET Clin ; 19(3): 431-446, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38816137

RESUMO

This article provides a thorough overview of the practice and multistep approach of hepatic radioembolization. The current literature on hepatic radioembolization in primary or metastatic liver tumors as well as future perspectives are discussed.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Compostos Radiofarmacêuticos , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Embolização Terapêutica/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Fígado/diagnóstico por imagem
3.
Cancers (Basel) ; 16(10)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38792003

RESUMO

PURPOSE: Hepatic Arteriography and C-Arm CT-Guided Ablation of liver tumors (HepACAGA) is a novel technique, combining hepatic-arterial contrast injection with C-arm CT-guided navigation. This study compared the outcomes of the HepACAGA technique with patients treated with conventional ultrasound (US) and/or CT-guided ablation. MATERIALS AND METHODS: In this retrospective cohort study, all consecutive patients with hepatocellular carcinoma (HCC) or colorectal liver metastases (CRLM) treated with conventional US-/CT-guided ablation between 1 January 2015, and 31 December 2020, and patients treated with HepACAGA between 1 January 2021, and 31 October 2023, were included. The primary outcome was local tumor recurrence-free survival (LTRFS). Secondary outcomes included the local tumor recurrence (LTR) rate and complication rate. RESULTS: 68 patients (120 tumors) were included in the HepACAGA cohort and 53 patients (78 tumors) were included in the conventional cohort. In both cohorts, HCC was the predominant tumor type (63% and 73%, respectively). In the HepACAGA cohort, all patients received microwave ablation. Radiofrequency ablation was the main ablation technique in the conventional group (78%). LTRFS was significantly longer for patients treated with the HepACAGA technique (p = 0.015). Both LTR and the complication rate were significantly lower in the HepACAGA cohort compared to the conventional cohort (LTR 5% vs. 26%, respectively; p < 0.001) (complication rate 4% vs. 15%, respectively; p = 0.041). CONCLUSIONS: In this study, the HepACAGA technique was safer and more effective than conventional ablation for HCC and CRLM, resulting in lower rates of local tumor recurrence, longer local tumor recurrence-free survival and fewer procedure-related complications.

4.
Eur Spine J ; 33(5): 2031-2042, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548932

RESUMO

PURPOSE: To assess whether the intention to intraoperatively reposition pedicle screws differs when spine surgeons evaluate the same screws with 2D imaging or 3D imaging. METHODS: In this online survey study, 21 spine surgeons evaluated eight pedicle screws from patients who had undergone posterior spinal fixation. In a simulated intraoperative setting, surgeons had to decide if they would reposition a marked pedicle screw based on its position in the provided radiologic imaging. The eight assessed pedicle screws varied in radiologic position, including two screws positioned within the pedicle, two breaching the pedicle cortex < 2 mm, two breaching the pedicle cortex 2-4 mm, and two positioned completely outside the pedicle. Surgeons assessed each pedicle screw twice without knowing and in random order: once with a scrollable three-dimensional (3D) image and once with two oblique fluoroscopic two-dimensional (2D) images. RESULTS: Almost all surgeons (19/21) intended to reposition more pedicle screws based on 3D imaging than on 2D imaging, with a mean number of pedicle screws to be repositioned of, respectively, 4.1 (± 1.3) and 2.0 (± 1.3; p < 0.001). Surgeons intended to reposition two screws placed completely outside the pedicle, one breaching 2-4mm, and one breaching < 2 mm more often based on 3D imaging. CONCLUSION: When provided with 3D imaging, spine surgeons not only intend to intraoperatively reposition pedicle screws at risk of causing postoperative complications more often but also screws with acceptable positions. This study highlights the potential of intraoperative 3D imaging as well as the need for consensus on how to act on intraoperative 3D information.


Assuntos
Parafusos Pediculares , Humanos , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Coluna Vertebral/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Imageamento Tridimensional/métodos , Inquéritos e Questionários , Cirurgiões
5.
Cancers (Basel) ; 16(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38539527

RESUMO

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

6.
Cardiovasc Intervent Radiol ; 47(4): 443-450, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38326577

RESUMO

PURPOSE: Radiation pneumonitis is a serious complication of radioembolization. In holmium-166 ([166Ho]) radioembolization, the lung mean dose (LMD) can be estimated (eLMD) using a scout dose with either technetium-99 m-macroaggregated albumin ([99mTc]MAA) or [166Ho]-microspheres. The accuracy of eLMD based on [99mTc]MAA (eLMDMAA) was compared to eLMD based on [166Ho]-scout dose (eLMDHo-scout) in two prospective clinical studies. MATERIALS AND METHODS: Patients were included if they received both scout doses ([99mTc]MAA and [166Ho]-scout), had a posttreatment [166Ho]-SPECT/CT (gold standard) and were scanned on the same hybrid SPECT/CT system. The correlation between eLMDMAA/eLMDHo-scout and LMDHo-treatment was assessed by Spearman's rank correlation coefficient (r). Wilcoxon signed rank test was used to analyze paired data. RESULTS: Thirty-seven patients with unresectable liver metastases were included. During follow-up, none developed symptoms of radiation pneumonitis. Median eLMDMAA (1.53 Gy, range 0.09-21.33 Gy) was significantly higher than median LMDHo-treatment (0.00 Gy, range 0.00-1.20 Gy; p < 0.01). Median eLMDHo-scout (median 0.00 Gy, range 0.00-1.21 Gy) was not significantly different compared to LMDHo-treatment (p > 0.05). In all cases, eLMDMAA was higher than LMDHo-treatment (p < 0.01). While a significant correlation was found between eLMDHo-scout and LMDHo-treatment (r = 0.43, p < 0.01), there was no correlation between eLMDMAA and LMDHo-treatment (r = 0.02, p = 0.90). CONCLUSION: [166Ho]-scout dose is superior in predicting LMD over [99mTc]MAA, in [166Ho]-radioembolization. Consequently, [166Ho]-scout may limit unnecessary patient exclusions and avoid unnecessary therapeutic activity reductions in patients eligible for radioembolization. TRAIL REGISTRATION: NCT01031784, registered December 2009. NCT01612325, registered June 2012.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Pneumonite por Radiação , Humanos , Estudos Prospectivos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/tratamento farmacológico , Radioisótopos de Ítrio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Embolização Terapêutica/efeitos adversos , Pulmão/diagnóstico por imagem , Microesferas , Estudos Retrospectivos
7.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38132236

RESUMO

PURPOSE: Trans-arterial radioembolization is a well-studied tumoricidal treatment for liver malignancies; however, consensus and evidence regarding periprocedural prophylactic medication (PPM) are lacking. METHODS: A single-center retrospective analysis from 2014 to 2020 was performed in patients treated with 90Y-glass microspheres for neuroendocrine or colorectal liver metastases. Inclusion criteria were the availability of at least 3 months of clinical, biochemical, and imaging follow-up and post-treatment 90Y-PET/CT imaging for the determination of the whole non-tumorous liver absorbed dose (Dh). Logistic regression models were used to investigate if variables (among which are P/UDCA and Dh) were associated with either clinical toxicity, biochemical toxicity, or hepatotoxicity. Additionally, a structured literature search was performed in November 2022 to identify all publications related to PPM use in radioembolization treatments. RESULTS: Fifty-one patients received P/UDCA as post-treatment medication, while 19 did not. No correlation was found between toxicity and P/UDCA use. Dh was associated with biochemical toxicity (p = 0.05). A literature review resulted in eight relevant articles, including a total of 534 patients, in which no consistent advice regarding PPM was provided. CONCLUSION: In this single-center, retrospective review, P/UDCA use did not reduce liver toxicity in patients with metastatic liver disease. The whole non-tumorous liver-absorbed dose was the only significant factor for hepatotoxicity. No standardized international guidelines or supporting evidence exist for PPM in radioembolization.

8.
Cardiovasc Intervent Radiol ; 46(10): 1365-1374, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37704863

RESUMO

PURPOSE: We present a technique that combines Hepatic Arteriography with C-arm CT-Guided Ablation (HepACAGA) to improve tumor visualization, navigation and margin confirmation for percutaneous ablation of liver tumors. MATERIALS AND METHODS: All consecutive patients scheduled for HepACAGA between April 20th, 2021, and November 2nd, 2021, were included in this retrospective, cohort study. HepACAGA was performed in an angiography-suite under general anesthesia. The hepatic artery was catheterized for selective contrast injection. C-arm CT and guidance software were then used to visualize the tumor and the microwave antenna was inserted during apnea. Pre- and post-ablation C-arm CTs were performed and ablation margins assessed. Technical success, antenna placement deviation, number of repositions, tumor recurrence, and safety were evaluated. Technical success was defined as a tumor that was ablated according to the HepACAGA technique. RESULTS: A total of 21 patients (28 tumors) were included. The main tumor type was colorectal cancer liver metastases (11/21, 52%), followed by hepatocellular carcinoma (7/21, 33%), neuroendocrine tumor metastases (1/21, 5%), and other tumor types (2/21, 10%). The technical success rate was 93% (26/28 tumors) with two small hypovascular lesions unable to be identified. A single microwave antenna was used in all patients. The median antenna placement deviation was 1 mm (range 0-6 mm). At a median follow-up time of 16 months (range 5-22 months), there was no tumor recurrence in any patient. Safety analysis showed a complication rate of 5% grade 2 and 5% grade 3. CONCLUSION: HepACAGA was demonstrated to be a safe and effective percutaneous ablation technique, without any local tumor recurrence in this study.

9.
BMC Cancer ; 23(1): 771, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596578

RESUMO

BACKGROUND: High dose unilobar radioembolization (also termed 'radiation lobectomy')-the transarterial unilobar infusion of radioactive microspheres as a means of controlling tumour growth while concomitantly inducing future liver remnant hypertrophy-has recently gained interest as induction strategy for surgical resection. Prospective studies on the safety and efficacy of the unilobar radioembolization-surgery treatment algorithm are lacking. The RALLY study aims to assess the safety and toxicity profile of holmium-166 unilobar radioembolization in patients with hepatocellular carcinoma ineligible for surgery due to insufficiency of the future liver remnant. METHODS: The RALLY study is a multicenter, interventional, non-randomized, open-label, non-comparative safety study. Patients with hepatocellular carcinoma who are considered ineligible for surgery due to insufficiency of the future liver remnant (< 2.7%/min/m2 on hepatobiliary iminodiacetic acid scan will be included. A classical 3 + 3 dose escalation model will be used, enrolling three to six patients in each cohort. The primary objective is to determine the maximum tolerated treated non-tumourous liver-absorbed dose (cohorts of 50, 60, 70 and 80 Gy). Secondary objectives are to evaluate dose-response relationships, to establish the safety and feasibility of surgical resection following unilobar radioembolization, to assess quality of life, and to generate a biobank. DISCUSSION: This will be the first clinical study to assess the unilobar radioembolization-surgery treatment algorithm and may serve as a stepping stone towards its implementation in routine clinical practice. TRIAL REGISTRATION: Netherlands Trial Register NL8902 , registered on 2020-09-15.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Microesferas , Estudos Prospectivos , Qualidade de Vida , Neoplasias Hepáticas/radioterapia , Hepatomegalia , Estudos Multicêntricos como Assunto
11.
Cancer Biother Radiopharm ; 38(4): 216-224, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36595357

RESUMO

Background: Immunotherapy in the form of checkpoint inhibitors has changed the treatment paradigm in oncology. Combining selective internal radiation therapy (SIRT) with immunotherapy has been suggested to potentially improve outcomes in hepatocellular carcinoma (HCC) and metastatic colorectal carcinoma (mCRC). In this systematic review, the authors discuss the current developments and available clinical data regarding the combination of immunotherapy and SIRT in treating hepatic malignancies. Methods: PubMed, Embase, and Cochrane library were systematically searched for eligible studies (adhering to Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines). Original patient studies written in English language with patients with HCC or mCRC who were treated with SIRT and immunotherapy were included. Endpoints evaluated included overall survival (OS), progression-free survival (PFS), and objective response rate (ORR). Results: 1038 publications were screened, from which 1034 publications were excluded. Four studies with a total of 87 patients were included in this systematic review, of which two consisted of mCRC and the other two HCC. All four studies showed no increased toxicities of the combination therapy over known data on monotherapy. One mCRC study reported a median OS of 8 months, while the other mCRC study ended due to futility. Both reported an ORR of 0%. The two HCC studies reported a median OS of 16.5 and 16.2 months. Median PFS was 5.6 and 5.7 months. ORR ranged from 31% to 80%. Conclusion: The combination of SIRT and immunotherapy has been studied in four early-phase studies showing a favorable safety profile. Further studies are necessary to understand the possible synergy and possible benefit of combination therapy.


Assuntos
Carcinoma Hepatocelular , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Terapia Combinada , Neoplasias Colorretais/tratamento farmacológico , Imunoterapia
12.
J Interv Med ; 6(4): 153-159, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38312126

RESUMO

Liver malignancy, including primary liver cancer and metastatic liver cancer, has become one of the most common causes of cancer-related death worldwide due to the high malignant degree and limited systematic treatment strategy. Radioembolization with yttrium-90 (90Y)-loaded microspheres is a relatively novel technology that has made significant progress in the local treatment of liver malignancy. The different steps in the extensive work-up of radioembolization for patients with an indication for treatment with 90Y microspheres, from patient selection to follow up, both technically and clinically, are discussed in this paper. It describes the application and development of 90Y microspheres in the treatment of liver cancer.

13.
Int J Comput Assist Radiol Surg ; 17(10): 1933-1945, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35986831

RESUMO

PURPOSE: We assessed the accuracy of a new 3D2D registration algorithm to be used for navigated spine surgery and explored anatomical and radiologic parameters affecting the registration accuracy. Compared to existing 3D2D registration algorithms, the algorithm does not need bone-mounted or table-mounted instruments for registration. Neither does the intraoperative imaging device have to be tracked or calibrated. METHODS: The rigid registration algorithm required imaging data (a pre-existing CT scan (3D) and two angulated fluoroscopic images (2D)) to register positions of vertebrae in 3D and is based on non-invasive skin markers. The algorithm registered five adjacent vertebrae and was tested in the thoracic and lumbar spine from three human cadaveric specimens. The registration accuracy was calculated for each registered vertebra and measured with the target registration error (TRE) in millimeters. We used multivariable analysis to identify parameters independently affecting the algorithm's accuracy such as the angulation between the two fluoroscopic images (between 40° and 90°), the detector-skin distance, the number of skin markers applied, and waist circumference. RESULTS: The algorithm registered 780 vertebrae with a median TRE of 0.51 mm [interquartile range 0.32-0.73 mm] and a maximum TRE of 2.06 mm. The TRE was most affected by the angulation between the two fluoroscopic images obtained (p < 0.001): larger angulations resulted in higher accuracy. The algorithm was more accurate in thoracic vertebrae (p = 0.004) and in the specimen with the smallest waist circumference (p = 0.003). The algorithm registered all five adjacent vertebrae with similar accuracy. CONCLUSION: We studied the accuracy of a new 3D2D registration algorithm based on non-invasive skin markers. The algorithm registered five adjacent vertebrae with similar accuracy in the thoracic and lumbar spine and showed a maximum target registration error of approximately 2 mm. To further evaluate its potential for navigated spine surgery, the algorithm may now be integrated into a complete navigation system.


Assuntos
Cirurgia Assistida por Computador , Algoritmos , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia
14.
J Nucl Med ; 63(12): 1891-1898, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35589409

RESUMO

The safety and efficacy of 166Ho radioembolization was first determined in the HEPAR and HEPAR II studies, which, however, excluded patients with hepatocellular carcinoma (HCC). The aim of this prospective clinical early phase II study was to establish the toxicity profile of 166Ho radioembolization in patients with measurable, liver-dominant HCC; Barcelona clinic liver cancer stage B or C; a Child-Pugh score of no more than B7; and an Eastern Cooperative Oncology Group performance status of 0-1 without curative treatment options. Methods: The primary endpoint was a rate of unacceptable toxicity defined as grade 3 hyperbilirubinemia (Common Terminology Cancer Adverse Events, version 4.03) in combination with a low albumin or ascites level in the absence of disease progression or treatment-related serious adverse events. Secondary endpoints included overall toxicity, response, survival, change in α-fetoprotein, and quality of life. Thirty-one patients with Barcelona clinic liver cancer stage B (71%) or C (29%) HCC were included, mostly multifocal (87%) or bilobar (55%) disease. Results: Common grade 1 or 2 clinical toxicity included fatigue (71%), back pain (55%), ascites (32%), dyspnea (23%), nausea (23%), and abdominal pain (23%), with no more than 10% grade 3-5 toxicity. Grade 3 laboratory toxicity (>10%) included an aspartate transaminase and γ-glutamyltransferase increase (16%), hyperglycemia (19%), and lymphopenia (29%). Treatment-related unacceptable toxicity occurred in 3 of 31 patients. At 3 mo, 54% of target lesions showed a complete or partial response according to modified RECIST. Median overall survival was 14.9 mo (95% CI, 10.4-24.9 mo). No significant changes in quality of life or pain were observed. Conclusion: The safety of 166Ho radioembolization was confirmed in HCC, with less than 10% unacceptable toxicity. Efficacy data support further evaluation.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Qualidade de Vida , Ascite/etiologia , Ascite/terapia , Embolização Terapêutica/efeitos adversos , Microesferas , Resultado do Tratamento , Radioisótopos de Ítrio
15.
Cardiovasc Intervent Radiol ; 45(5): 606-612, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35233662

RESUMO

PURPOSE: The primary objective is to determine the minimal ablation margin required to achieve a local recurrence rate of < 10% in patients with hepatocellular carcinoma undergoing thermal ablation. Secondary objectives are to analyze the correlation between ablation margins and local recurrence and to assess efficacy. MATERIALS AND METHODS: This study is a prospective, multicenter, non-experimental, non-comparative, open-label study. Patients > 18 years with Barcelona Clinic Liver Cancer stage 0/A hepatocellular carcinoma (or B with a maximum of two lesions < 5 cm each) are eligible. Patients will undergo dual-phase contrast-enhanced computed tomography directly before and after ablation. Ablation margins will be quantitatively assessed using co-registration software, blinding assessors (i.e. two experienced radiologists) for outcome. Presence and location of recurrence are evaluated independently on follow-up scans by two other experienced radiologists, blinded for the quantitative margin analysis. A sample size of 189 tumors (~ 145 patients) is required to show with 80% power that the risk of local recurrence is confidently below 10%. A two-sided binomial z-test will be used to test the null hypothesis that the local recurrence rate is ≥ 10% for patients with a minimal ablation margin ≥ 2 mm. Logistic regression will be used to find the relationship between minimal ablation margins and local recurrence. Kaplan-Meier estimates are used to assess local and overall recurrence, disease-free and overall survival. DISCUSSION: It is expected that this study will result in a clear understanding of the correlation between ablation margins and local recurrence. Using co-registration software in future patients undergoing ablation for hepatocellular carcinoma may improve intraprocedural evaluation of technical success. Trial registration The Netherlands Trial Register (NL9713), https://www.trialregister.nl/trial/9713 .


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Margens de Excisão , Estudos Multicêntricos como Assunto , Recidiva Local de Neoplasia/cirurgia , Estudos Prospectivos , Resultado do Tratamento
17.
J Nucl Med ; 62(11): 1616-1623, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33741643

RESUMO

Radioembolization based on personalized treatment planning requires established dose-response and dose-toxicity relationships. The aim of this study was to investigate dose-response and dose-toxicity relationships in patients with colorectal liver metastases (CRLMs) treated with glass 90Y-microspheres. Methods: All CRLM patients treated with glass 90Y-microspheres in our institution were retrospectively analyzed. The tumor-absorbed dose was calculated for each measurable metastasis (i.e.,18F-FDG-positive and more than a 5-cm3 tumor volume) on posttreatment 90Y PET. Metabolic tumor response was determined on 18F-FDG PET/CT by measuring the total lesion glycolysis at baseline and at 3 mo after treatment. The relationship between tumor-absorbed dose and metabolic response was determined on a per-lesion and per-patient basis using a linear mixed-effects regression model. Clinical toxicity and laboratory toxicity were correlated with healthy liver-absorbed dose. Results: Thirty-one patients were included. The median tumor-absorbed dose of 85 measurable metastases was 133 Gy (range, 20-1001 Gy). Per response category, this was 196 Gy for complete response (CR), 177 Gy for partial response (PR), 72 Gy for stable disease, and 95 Gy for progressive disease (PD). A significant dose-response relationship was found on a tumor level, with a significantly higher tumor-absorbed dose in metastases with CR (+94%) and PR (+74%) than in metastases with PD (P < 0.001). A similar relationship was found on a patient level, with PR having a higher tumor-absorbed dose than did PD (+58%, P = 0.044). A tumor-absorbed dose of more than 139 Gy predicted a 3-mo metabolic response with the greatest accuracy (89% specificity and 77% sensitivity), whereas a tumor-absorbed dose of more than 189 Gy predicted response with 97% specificity and 45% sensitivity. The median healthy liver-absorbed dose was 63 Gy (range, 24-113 Gy). Toxicity was limited mostly to grades 1 and 2, with 1 case of radioembolization-induced liver disease in a patient who received the highest healthy liver-absorbed dose. A positive trend was seen for most laboratory parameters in our dose-toxicity analysis. Conclusion: A significant relationship was observed between dose and response in CRLM patients treated with glass 90Y radioembolization.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
J Nucl Med ; 62(2): 272-279, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32591491

RESUMO

Radioembolization is a treatment option for colorectal cancer (CRC) patients with inoperable, chemorefractory hepatic metastases. Personalized treatment requires established dose thresholds. Hence, the aim of this study was to explore the relationship between dose and effect (i.e., response and toxicity) in CRC patients treated with 166Ho radioembolization. Methods: CRC patients treated in the HEPAR II and SIM studies were analyzed. Absorbed doses were estimated using the activity distribution on posttreatment 166Ho SPECT/CT. Metabolic response was assessed using the change in total-lesion glycolysis on 18F-FDG PET/CT between baseline and 3-mo follow-up. Toxicity between treatment and 3 mo was evaluated according to the Common Terminology Criteria for Adverse Events (CTCAE), version 5, and its relationship with parenchyma-absorbed dose was assessed using linear models. The relationship between tumor-absorbed dose and patient- and tumor-level response was analyzed using linear mixed models. Using a threshold of 100% sensitivity for response, the threshold for a minimal mean tumor-absorbed dose was determined and its impact on survival was assessed. Results: Forty patients were included. The median parenchyma-absorbed dose was 37 Gy (range, 12-55 Gy). New CTCAE grade 3 or higher clinical and laboratory toxicity was present in 8 and 7 patients, respectively. For any clinical toxicity (highest grade per patient), the mean difference in parenchymal dose (Gy) per step increase in CTCAE grade category was 5.75 (95% CI, 1.18-10.32). On a patient level, metabolic response was as follows: complete response, n = 1; partial response, n = 11; stable disease, n = 17; and progressive disease, n = 8. The mean tumor-absorbed dose was 84% higher in patients with complete or partial response than in patients with progressive disease (95% CI, 20%-180%). Survival for patients with a mean tumor-absorbed dose of more than 90 Gy was significantly better than for patients with a mean tumor-absorbed dose of less than 90 Gy (hazard ratio, 0.16; 95% CI, 0.06-0.511). Conclusion: A significant dose-response relationship in CRC patients treated with 166Ho radioembolization was established, and a positive association between toxicity and parenchymal dose was found. For future patients, it is advocated to use a 166Ho scout dose to select patients and yo personalize the administered activity, targeting a mean tumor-absorbed dose of more than 90 Gy and a parenchymal dose of less than 55 Gy.


Assuntos
Neoplasias Colorretais/radioterapia , Embolização Terapêutica , Hólmio/uso terapêutico , Radioisótopos/uso terapêutico , Adulto , Idoso , Neoplasias Colorretais/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Embolização Terapêutica/efeitos adversos , Feminino , Fluordesoxiglucose F18 , Hólmio/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos/efeitos adversos , Segurança , Análise de Sobrevida , Resultado do Tratamento
19.
Eur J Nucl Med Mol Imaging ; 48(5): 1658-1668, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33128132

RESUMO

PURPOSE: The objective of this study was to investigate whether the use of an anti-reflux catheter improves tumor targeting for colorectal cancer patients with unresectable, chemorefractory liver metastases (mCRC) treated with holmium-166 (166Ho)-radioembolization. MATERIALS AND METHODS: In this perspective, within-patient randomized study, left and right hepatic perfusion territories were randomized between infusion with a Surefire® anti-reflux catheter or a standard microcatheter. The primary outcome was the difference in tumor to non-tumor (T/N) activity distribution. Secondary outcomes included the difference in infusion efficiency, absorbed doses, predictive value of 166Ho-scout, dose-response relation, and survival. RESULTS: Twenty-one patients were treated in this study (the intended number of patients was 25). The median T/N activity concentration ratio with the use of the anti-reflux catheter was 3.2 (range 0.9-8.7) versus 3.6 (range 0.8-13.3) with a standard microcatheter. There was no difference in infusion efficiency (0.04% vs. 0.03% residual activity for the standard microcatheter and anti-reflux catheter, respectively) (95%CI - 0.05-0.03). No influence of the anti-reflux catheter on the dose-response rate was found. Median overall survival was 7.8 months (95%CI 6-13). CONCLUSION: Using a Surefire® anti-reflux catheter did not result in a higher T/N activity concentration ratio in mCRC patients treated with 166Ho-radioembolization, nor did it result in improved secondary outcomes measures. TRIAL REGISTRATION: clinicaltrials.gov identifier: NCT02208804.


Assuntos
Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Catéteres , Neoplasias Colorretais/radioterapia , Hólmio/uso terapêutico , Humanos , Neoplasias Hepáticas/radioterapia , Estudos Prospectivos , Radioisótopos , Radioisótopos de Ítrio/uso terapêutico
20.
EJNMMI Res ; 10(1): 107, 2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32960390

RESUMO

BACKGROUND: Radioembolization is an established treatment modality in colorectal cancer patients with liver-dominant disease in a salvage setting. Selection of patients who will benefit most is of vital importance. The aim of this study was to assess response (and mode of progression) at 3 months after radioembolization and the impact of baseline characteristics. METHODS: Three months after radioembolization with either yttrium-90 resin/glass or holmium-166, anatomic response, according to RECIST 1.1, was evaluated in 90 patients. Correlations between baseline characteristics and efficacy were evaluated. For more detailed analysis of progressive disease as a dismal clinical entity, distinction was made between intra- and extrahepatic progression, and between progression of existing metastases and new metastases. RESULTS: Forty-two patients (47%) had extrahepatic disease (up to five ≥ 1 cm lung nodules, and ≤ 2 cm lymph nodes) at baseline. No patients showed complete response, 5 (5.5%) patients had partial response, 16 (17.8%) had stable disease, and 69 (76.7%) had progressive disease. Most progressive patients (67/69; 97%) had new metastases (intra-hepatic N = 11, extrahepatic N = 32; or both N = 24). Significantly fewer patients had progressive disease in the group of patients presenting without extrahepatic metastases at baseline (63% versus 93%; p = 0.0016). Median overall survival in patients with extrahepatic disease was 6.5 months, versus 10 months in patients without extrahepatic disease at baseline (hazard ratio 1.79, 95%CI 1.24-2.57). CONCLUSIONS: Response at 3-month follow-up and survival were heavily influenced by new metastases. Patients with extrahepatic disease at baseline had a worse outcome compared to patients without.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...