Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Antibiotics (Basel) ; 10(8)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34439000

RESUMO

Molecular-based carbapenem resistance testing in Gram-negative bacterial bloodstream infections (BSIs) is currently limited because of the reliance on positive blood culture (BC) samples. The T2Resistance™ panel may now allow the detection of carbapenemase- and other ß-lactamase encoding genes directly from blood samples. We detected carbapenem resistance genes in 11 (84.6%) of 13 samples from patients with BC-documented BSIs (10 caused by KPC-producing Klebsiellapneumoniae and 1 caused by VIM/CMY-producing Citrobacter freundii). Two samples that tested negative for carbapenem resistance genes were from patients with BC-documented BSIs caused by KPC-producing K. pneumoniae who were receiving effective antibiotic therapy. In conclusion, our findings suggest that the T2Resistance™ panel can be a reliable tool for diagnosing carbapenem-resistant Gram-negative bacterial BSIs.

2.
Clin Infect Dis ; 68(6): 1052-1057, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30307486

RESUMO

Borrelia burgdorferi was discovered to be the cause of Lyme disease in 1983, leading to seroassays. The 1994 serodiagnostic testing guidelines predated a full understanding of key B. burgdorferi antigens and have a number of shortcomings. These serologic tests cannot distinguish active infection, past infection, or reinfection. Reliable direct-detection methods for active B. burgdorferi infection have been lacking in the past but are needed and appear achievable. New approaches have effectively been applied to other emerging infections and show promise in direct detection of B. burgdorferi infections.


Assuntos
Borrelia burgdorferi , Doença de Lyme/diagnóstico , Doença de Lyme/microbiologia , Borrelia burgdorferi/genética , Testes Diagnósticos de Rotina , Genômica/métodos , Ensaios de Triagem em Larga Escala , Humanos , Reação em Cadeia da Polimerase , Testes Sorológicos
3.
Biol Cell ; 109(8): 312-321, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28643869

RESUMO

BACKGROUND INFORMATION: Vascular endothelial cells (ECs) are a well-known cell system used in the study of mechanobiology. Using cultured ECs, we found that platelet EC adhesion molecule 1 (PECAM-1, CD31), a cell adhesion protein localised to regions of EC-EC contact, was rapidly tyrosine phosphorylated in ECs exposed to shear or cyclic stretch. Src-homology 2 domain-containing protein tyrosine phosphatase 2 (SHP2) binds phosphorylated PECAM-1 and activates the extracellular signal-regulated kinase1/2 (ERK1/2) signalling cascade, a known flow-activated signalling pathway. RESULTS: Although PECAM-1 tyrosine phosphorylation is characterised in ECs exposed to fluid shear stress, it is less well demonstrated in the cells stretched cyclically. Thus, we first show that PECAM-1 is tyrosine-phosphorylated in ECs cyclically stretched. We hypothesise that when an external force is applied to a monolayer of ECs, the force is directly transmitted to PECAM-1 which is then stretched and phosphorylation sites in its cytoplasmic domain are exposed and phosphorylated. This hypothesis requires the presence of any stretchable structure within the PECAM-1 cytoplasmic domain. Force spectroscopy measurements were performed with a construct containing cytoplasmic PECAM-1 domains inserted between I27 motifs, a recombinant string of the structural elements from titin. This strategy allowed us to identify the events in which a single molecule is being pulled and to detect the unravelling of the cytoplasmic domain of PECAM-1 by force. The response by PECAM-1 to mechanical loading was heterogeneous but with magnitudes as high as or higher than the naturally force bearing I27 domains. CONCLUSIONS: The PECAM-1 cytoplasmic domain has a structure that can be unfolded by externally applied force and this unfolding of PECAM-1 may be necessary for its phosphorylation, the first step of PECAM-1 mechanosignalling. SIGNIFICANCE: When EC monolayers are mechanically stimulated, the PECAM-1 found at EC contacts is phosphorylated. We have proposed that under these conditions, the cytoplasmic domain of PECAM-1 is unfolded, which then exposes a phosphorylation site, allowing it to be accessed. The stretch induced unfolding is essential to this model of PECAM-1 mechanosignalling. In this study, we investigate whether the cytoplasmic domain of PECAM-1 has a stretchable structure, and the results are in line with our hypothesis.


Assuntos
Aorta/metabolismo , Endotélio Vascular/metabolismo , Mecanotransdução Celular/fisiologia , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Tirosina/metabolismo , Animais , Aorta/citologia , Bovinos , Células Cultivadas , Endotélio Vascular/citologia , Mutação , Fosforilação , Molécula-1 de Adesão Celular Endotelial a Plaquetas/química , Molécula-1 de Adesão Celular Endotelial a Plaquetas/genética , Transdução de Sinais
4.
J Clin Microbiol ; 55(8): 2453-2461, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28566314

RESUMO

In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii Clinical samples (n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples.


Assuntos
Técnicas Bacteriológicas/métodos , Borrelia/classificação , Borrelia/isolamento & purificação , Doença de Lyme/diagnóstico , Espectroscopia de Ressonância Magnética/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Borrelia/química , Borrelia/genética , Humanos , Pessoa de Meia-Idade , Adulto Jovem
5.
Proc Natl Acad Sci U S A ; 110(46): 18425-30, 2013 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-24167263

RESUMO

We have developed electroosmotic pumps (EOPs) fabricated from 15-nm-thick porous nanocrystalline silicon (pnc-Si) membranes. Ultrathin pnc-Si membranes enable high electroosmotic flow per unit voltage. We demonstrate that electroosmosis theory compares well with the observed pnc-Si flow rates. We attribute the high flow rates to high electrical fields present across the 15-nm span of the membrane. Surface modifications, such as plasma oxidation or silanization, can influence the electroosmotic flow rates through pnc-Si membranes by alteration of the zeta potential of the material. A prototype EOP that uses pnc-Si membranes and Ag/AgCl electrodes was shown to pump microliter per minute-range flow through a 0.5-mm-diameter capillary tubing with as low as 250 mV of applied voltage. This silicon-based platform enables straightforward integration of low-voltage, on-chip EOPs into portable microfluidic devices with low back pressures.


Assuntos
Dispositivos Lab-On-A-Chip , Membranas Artificiais , Microfluídica/instrumentação , Nanoestruturas/química , Pressão Osmótica , Silício/química , Campos Eletromagnéticos , Microfluídica/métodos
6.
ACS Nano ; 4(11): 6973-81, 2010 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-21043434

RESUMO

Porous nanocrystalline silicon (pnc-Si) is a 15 nm thin free-standing membrane material with applications in small-scale separations, biosensors, cell culture, and lab-on-a-chip devices. Pnc-Si has already been shown to exhibit high permeability to diffusing species and selectivity based on molecular size or charge. In this report, we characterize properties of pnc-Si in pressurized flows. We compare results to long-standing theories for transport through short pores using actual pore distributions obtained directly from electron micrographs. The measured water permeability is in agreement with theory over a wide range of pore sizes and porosities and orders of magnitude higher than those exhibited by commercial ultrafiltration and experimental carbon nanotube membranes. We also show that pnc-Si membranes can be used in dead-end filtration to fractionate gold nanoparticles and protein size ladders with better than 5 nm resolution, insignificant sample loss, and little dilution of the filtrate. These performance characteristics, combined with scalable manufacturing, make pnc-Si filtration a straightforward solution to many nanoparticle and biological separation problems.


Assuntos
Fracionamento Químico/métodos , Membranas Artificiais , Nanopartículas , Silício/química , Filtração , Microtecnologia , Nanopartículas/química , Permeabilidade , Porosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...