Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Crit Rev Anal Chem ; : 1-12, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37358486

RESUMO

Since diagnostic laboratories handle large COVID-19 samples, researchers have established laboratory-based assays and developed biosensor prototypes. Both share the same purpose; to ascertain the occurrence of air and surface contaminations by the SARS-CoV-2 virus. However, the biosensors further utilize internet-of-things (IoT) technology to monitor COVID-19 virus contamination, specifically in the diagnostic laboratory setting. The IoT-capable biosensors have great potential to monitor for possible virus contamination. Numerous studies have been done on COVID-19 virus air and surface contamination in the hospital setting. Through reviews, there are abundant reports on the viral transmission of SARS-CoV-2 through droplet infections, person-to-person close contact and fecal-oral transmission. However, studies on environmental conditions need to be better reported. Therefore, this review covers the detection of SARS-CoV-2 in airborne and wastewater samples using biosensors with comprehensive studies in methods and techniques of sampling and sensing (2020 until 2023). Furthermore, the review exposes sensing cases in public health settings. Then, the integration of data management together with biosensors is well explained. Last, the review ended with challenges to having a practical COVID-19 biosensor applied for environmental surveillance samples.

2.
Membranes (Basel) ; 11(12)2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34940497

RESUMO

The LC-MEMS pressure sensor is an attractive option for an implantable sensor. It senses pressure wirelessly through an LC resonator, eliminating the requirement for electrical wiring or a battery system. However, the sensitivity of LC-MEMS pressure sensors is still comparatively low, especially in biomedical applications, which require a highly-sensitive sensor to measure low-pressure variations. This study presents the microfabrication of an LC wireless MEMS pressure sensor that utilizes a PMMA-Graphene (PMMA/Gr) membrane supported on a silicon trench as the deformable structure. The (PMMA/Gr) membrane was employed to increase the sensor's sensitivity due to its very low elastic modulus making it easy to deform under extremely low pressure. The overall size of the fabricated sensor was limited to 8 mm × 8 mm. The experimental results showed that the capacitance value changed from 1.64 pF to 12.32 pF when the applied pressure varied from 0 to 5 psi. This capacitance variation caused the frequency response to change from 28.74 MHz to 78.76 MHz. The sensor sensitivity was recorded with a value of 193.45 kHz/mmHg and a quality factor of 21. This study concludes that the (PMMA/Gr) membrane-based LC-MEMS pressure sensor has been successfully designed and fabricated and shows good potential in biomedical sensor applications.

3.
PLoS One ; 10(4): e0121836, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25853411

RESUMO

A centrifugal compact disc (CD) microfluidic platform with reservoirs, micro-channels, and valves can be employed for implementing a complete immunoassay. Detection or biosensor chambers are either coated for immuno-interaction or a biosensor chip is inserted in them. On microfluidic CDs featuring such multi-step chemical/biological processes, the biosensor chamber must be repeatedly filled with fluids such as enzymes solutions, buffers, and washing solutions. After each filling step, the biosensor chamber needs to be evacuated by a passive siphoning process to prepare it for the next step in the assay. However, rotational speed dependency and limited space on a CD are two big obstacles to performing such repetitive filling and siphoning steps. In this work, a unique thermo-pneumatic (TP) Push-Pull pumping method is employed to provide a superior alternative biosensor chamber filling and evacuation technique. The proposed technique is demonstrated on two CD designs. The first design features a simple two-step microfluidic process to demonstrate the evacuation technique, while the second design shows the filling and evacuation technique with an example sequence for an actual immunoassay. In addition, the performance of the filling and evacuation technique as a washing step is also evaluated quantitatively and compared to the conventional manual bench top washing method. The two designs and the performance evaluation demonstrate that the technique is simple to implement, reliable, easy to control, and allows for repeated push-pulls and thus filling and emptying of the biosensor chamber. Furthermore, by addressing the issue of rotational speed dependency and limited space concerns in implementing repetitive filling and evacuation steps, this newly introduced technique increases the flexibility of the microfluidic CD platform to perform multi-step biological and chemical processes.


Assuntos
Técnicas Biossensoriais/instrumentação , Discos Compactos , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Fatores de Tempo
4.
Artigo em Inglês | MEDLINE | ID: mdl-24110985

RESUMO

Thermo-pneumatic (TP) pumping is a method employing the principle of expanding heated air to transfer fluids back towards the CD center on the centrifugal microfluidic CD platform. While the TP features are easy to fabricate as no moving parts are involved, it consumes extra real estate on the CD, and because heating is involved, it introduces unnecessary heating to the fluids on the CD. To overcome these limitations, we introduce a multi-level 3D approach and implement forced convection heating. In a multi-level 3D CD, the TP features are relocated to a separate top level, while the microfluidic process remains on a lower bottom level. This allows for heat shielding of the fluids in the microfluidic process level, and also improve usage of space on the CD. To aid in future implementations of TP pumping on a multi-level 3D CD, studies on the effect of heat source setting, and the effect of positioning the TP feature (it distance from the CD center) on CD surface heating are also presented. In this work, we successfully demonstrate a multi-level 3D approach to implement TP pumping on the microfluidic CD platform.


Assuntos
Centrifugação/instrumentação , Discos Compactos , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Temperatura Alta , Pressão
5.
Lab Chip ; 13(16): 3199-209, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23774994

RESUMO

A technique known as thermo-pneumatic (TP) pumping is used to pump fluids on a microfluidic compact disc (CD) back towards the CD center against the centrifugal force that pushes liquids from the center to the perimeter of the disc. Trapped air expands in a TP air chamber during heating, and this creates positive pressure on liquids located in chambers connected to that chamber. While the TP air chamber and connecting channels are easy to fabricate in a one-level CD manufacturing technique, this approach provides only one way pumping between two chambers, is real-estate hungry and leads to unnecessary heating of liquids in close proximity to the TP chamber. In this paper, we present a novel TP push and pull pumping method which allows for pumping of liquid in any direction between two connected liquid chambers. To ensure that implementation of TP push and pull pumping also addresses the issue of space and heating challenges, a multi-level 3D CD design is developed, and localized forced convection heating, rather than infra-red (IR) is applied. On a multi-level 3D CD, the TP features are placed on a top level separate from the rest of the microfluidic processes that are implemented on a lower separate level. This approach allows for heat shielding of the microfluidic process level, and efficient usage of space on the CD for centrifugal handling of liquids. The use of localized forced convection heating, rather than infra-red (IR) or laser heating in earlier implementations allows not only for TP pumping of liquids while the CD is spinning but also makes heat insulation for TP pumping and other fluidic functions easier. To aid in future implementations of TP push and pull pumping on a multi-level 3D CD, study on CD surface heating is also presented. In this contribution, we also demonstrate an advanced application of pull pumping through the implementation of valve-less switch pumping.


Assuntos
Discos Compactos , Fenômenos Mecânicos , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Temperatura Alta
6.
Med Biol Eng Comput ; 51(5): 525-35, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23292292

RESUMO

This paper presents a theoretical development and critical analysis of the burst frequency equations for capillary valves on a microfluidic compact disc (CD) platform. This analysis includes background on passive capillary valves and the governing models/equations that have been developed to date. The implicit assumptions and limitations of these models are discussed. The fluid meniscus dynamics before bursting is broken up into a multi-stage model and a more accurate version of the burst frequency equation for the capillary valves is proposed. The modified equations are used to evaluate the effects of various CD design parameters such as the hydraulic diameter, the height to width aspect ratio, and the opening wedge angle of the channel on the burst pressure.


Assuntos
Microfluídica/instrumentação , Modelos Teóricos , Algoritmos , Centrifugação/instrumentação , Discos Compactos , Desenho de Equipamento , Hidrodinâmica , Miniaturização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...