Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Cardiol ; 28(5): 372-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17687592

RESUMO

Systolic ventricular function has been demonstrated to remain unchanged following bidirectional cavopulmonary anastomosis (BCPA). The effects of BCPA on diastolic ventricular performance have not been critically assessed. The objective of this study was to evaluate the changes in diastolic ventricular function indices early after BCPA. Nineteen patients were enrolled prospectively. Transthoracic echocardiograms were performed at a median of 4 days prior to and 5 days subsequent to BCPA. Diastolic and systolic echocardiographic indices of ventricular performance were measured for the dominant ventricle. End diastolic volume decreased postoperatively (71.1 +/- 21.1 vs 68.08 +/- 17.9 ml/m2, p = 0.05). Tei index increased postoperatively (0.51 +/- 0.2 vs 0.62 +/- 0.1, p = 0.002), whereas inflow Doppler E velocity (70.3 +/- 13 vs 56.3 +/- 24.7 cm/sec, p = 0.04), E/A ratio (1.18 +/- 0.52 vs 0.84 +/- 0.2, p = 0.02), tissue Doppler E' velocity (9.5 +/- 2.5 vs 6.4 +/- 3.2 cm/sec, p = 0.03) and diastolic flow propagation velocity (56.5 +/- 12 vs 52.8 +/- 11 cm/sec, p = 0.04) all decreased. There was no change in ventricular mass, area change fraction, heart rate, or inflow Doppler A or tissue Doppler A' and S' velocities. This study demonstrated that diastolic indices of ventricular performance are altered indicating decreased diastolic function early following BCPA. Whether this observation is a result of a change in ventricular mass:volume ratio, loading conditions of the ventricle, ventricular geometry, or the effects of cardiopulmonary bypass remains to be determined.


Assuntos
Diástole/fisiologia , Derivação Cardíaca Direita , Função Ventricular , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Masculino , Período Pós-Operatório
2.
Ann Thorac Surg ; 71(4): 1251-4, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11308169

RESUMO

BACKGROUND: The two major surgical approaches to the relief of bulboventricular foramen (BVF) obstruction in patients with single left ventricle (LV) are the Damus-Kaye-Stansel (DKS) procedure or direct BVF resection. Theoretical advantages of the DKS include better out-flow gradient relief, lower potential incidences of postoperative heart block and lower incidences of reoperation. Potential disadvantages of this approach include increased semilunar valvar insufficiency, lack of feasibility when attempting septation-type operations for univentricular hearts, and a technically more difficult operation. We report the results of direct surgical BVF resection. METHODS: From June 1990 to June 1999, 9 patients had direct BVF resection performed at our institution. The median age at surgery was 16.5 years (range 1 month to 27 years). Diagnoses in these patients were [S,L,L] single LV (n = 8) and [S,D,D] single LV tricuspid atresia (n = 1). Eight of 9 patients had pulmonary artery bands placed either before BVF resection or at the same time as this procedure. Three patients required reoperation for reobstruction at the BVF (12 total operations in 9 patients). RESULTS: Median preoperative peak systolic gradient across the BVF measured at cardiac catheterization was 47 mm Hg (range 10 to 63 mm Hg). The median peak gradient measured by Doppler echocardiography was 44 mm Hg (range 5 to 125 mm Hg). Eight of 9 patients survived the operation to discharge from the hospital and 7 of 9 are alive at follow-up. At a median follow-up of 22 months (range 5 to 76 months), 8 of 8 surviving patients had an unobstructed BVF as determined by qualitative two-dimensional echocardiography and Doppler color flow imaging. There was one perioperative and one late death 5 months postoperatively (secondary to fungal sepsis). No patient developed new or worsened aortic insufficiency after BVF resection. Eight of 9 patients had no change in AV nodal conduction after surgery. One patient developed Mobitz II heart block requiring postoperative implantation of a pacemaker. CONCLUSIONS: Direct resection of an obstructive BVF can be performed with total relief of obstruction although reoperation may be required. Atrioventricular nodal function can be preserved in most patients with this operative approach, including those with [S,L,L] segmental anatomy.


Assuntos
Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Comunicação Interventricular/fisiopatologia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/anormalidades , Adolescente , Adulto , Arteriopatias Oclusivas/congênito , Arteriopatias Oclusivas/diagnóstico por imagem , Criança , Pré-Escolar , Eletrofisiologia , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Hemodinâmica/fisiologia , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Ultrassonografia Doppler
3.
Am J Cardiol ; 85(9): 1119-23, 2000 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-10781763

RESUMO

Serial echocardiographic measurements of the annulus and sinus were obtained in children before the Ross operation, and early and late postoperatively. Values were compared with normal standards for the aorta and pulmonary artery (PA). There was no significant difference between PA annulus measurements before surgery and the corresponding autograft immediately afterward (1.73 +/- 0.60 cm preoperatively; 1. 63 +/- 0.58 cm postoperatively, p = NS). Late after surgery the mean annulus diameter was enlarged compared with the normal aorta (DeltaZ 1.9 +/- 2.4), but remained relatively unchanged compared with the normal PA (DeltaZ 0.7 +/- 1.1, p <0.01). In contrast, the autograft sinus was dilated early after surgery (1.83 +/- 0.58 cm preoperatively; 2.18 +/- 0.73 cm postoperatively, p <0.01). Mean sinus Z score further increased compared with both the aorta (DeltaZ 1.3 +/- 1.7) and PA (DeltaZ 1.3 +/- 1.6). Use of standard PA measurements may be important in the assessment of autograft enlargement. Minimal change in autograft Z scores over time suggests that annulus enlargement is mainly due to somatic growth. In contrast, the autograft sinus showed an immediate and continued disproportionate increase in size over time, suggesting that sinus enlargement is largely due to passive dilation.


Assuntos
Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas/cirurgia , Artéria Pulmonar/anatomia & histologia , Valva Pulmonar/transplante , Adolescente , Valva Aórtica/diagnóstico por imagem , Superfície Corporal , Criança , Pré-Escolar , Dilatação Patológica , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Valva Pulmonar/diagnóstico por imagem , Valores de Referência , Transplante Autólogo , Ultrassonografia
4.
J Am Soc Echocardiogr ; 11(12): 1145-54, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9923995

RESUMO

A mixture of valve types has been used in previous in vivo studies to assess the accuracy of Doppler echocardiography compared with catheter-measured pressure gradients across prosthetic mitral valves. However, limited data exist regarding the most commonly used bileaflet mechanical valve. We studied 14 sheep with St Jude Medical mechanical mitral valves. Continuous wave Doppler data were obtained across each of the 3 valve orifices. Hemodynamic data were obtained simultaneously by direct measurements with catheters. Valve sizes commonly used in the pediatric population in the mitral position (23 mm, 25 mm, and 27 mm) were studied. Linear regression analyses of Doppler-predicted versus catheter-measured gradients provided correlation coefficients ranging from 0.75 to 0.91. Agreement analysis demonstrated a scatter of Doppler data about the regression line. Although a reasonably good correlation of Doppler-predicted peak and mean pressure gradients across bileaflet mechanical valves exists in the mitral position, caution is needed when this method is applied to patients. Doppler overestimation was greatest across the 23-mm valves. Analyses of the specific orifice interrogated demonstrated higher estimated pressure gradients across the central orifice compared with the side orifices.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Valva Mitral/fisiologia , Animais , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Pressão , Ovinos
5.
Heart ; 76(4): 350-4, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8983683

RESUMO

OBJECTIVE: To evaluate the accuracy of quantitative three dimensional echocardiography in patients with deformed left ventricles. DESIGN: Three dimensional and cross sectional echocardiographic estimates of left ventricular volume and ejection fraction were prospectively compared to those obtained from magnetic resonance imaging. SETTING: Echocardiography laboratory of a university hospital. PATIENTS: 26 patients (9 months to 42 years, median age 11 years) with pulmonary hypertension and fixed reversal of normal interventricular septal curvature. MAIN OUTCOME MEASURES: Left ventricular end diastolic and end systolic volumes and ejection fraction. RESULTS: Three dimensional echocardiographic comparison to magnetic resonance imaging (MRI) yielded r values of 0.94 and 0.87 with a bias of -6.9 (SD 6.9) ml and -16 (11.2) ml for systolic and diastolic volumes respectively. Inter-observer variability was minimal (8.3% and 7.6% respectively). Cross sectional echocardiography gave correlation coefficients of 0.62 and 0.80 and bias of 3.1 (14.1) ml and 16.3 (18.3) ml for systolic and diastolic volumes respectively. Ejection fraction by three dimensional echocardiography also had closer agreement with MRI (bias = 1.1 (7.7)%) than cross sectional echocardiography (bias = 4.4 (13.9)%). CONCLUSIONS: Three dimensional echocardiography provides reliable estimates of left ventricular volumes and ejection fraction, comparable to magnetic resonance imaging in pulmonary hypertension patients with compressed ventricular geometry. Because it eliminates the need for geometric assumptions it shows closer agreement with magnetic resonance imaging in that setting than cross sectional echocardiography.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia , Ventrículos do Coração/patologia , Humanos , Hipertensão Pulmonar/patologia , Lactente , Imageamento por Ressonância Magnética
6.
J Am Soc Echocardiogr ; 9(5): 637-45, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8887866

RESUMO

The relative ease of acquisition and safety of two-dimensional echocardiography has established it as the mainstay for routine cardiac imaging. Translation of imaging data into useful quantitative information, however, requires fitting the ventricle to a specific geometric model. Because of its complex shape and anterior position, many attempts at right ventricular quantitation by two-dimensional echocardiography have been criticized as impractical and not reproducible. A simple method incorporating subcostal and apical imaging was introduced in 1984. This approach appeared to combine accuracy and practicability but was never validated in a clinical setting because of the difficulties of subcostal imaging in adults. This study assessed the feasibility and accuracy of this technique in the pediatric population. Results of volume comparison to values derived by magnetic resonance imaging were r = 0.96, standard error of the estimate (SEE) = 19.3 ml, and mean difference = 15 +/- 19.4 ml and r = 0.97, SEE = 12.3 ml, and bias = 5 +/- 11.8 ml for diastolic and systolic volumes, respectively. Comparison of estimates of ejection fraction with magnetic resonance imaging demonstrated r = 0.90, SEE = 5.9%, and bias = 3% +/- 5.7%. Interobserver and intraobserver variability was 9.9% and 8.2%, respectively, for systolic volumes and 11.5% and 8.9%, respectively, for diastolic volumes. Evaluation of right ventricular size and function by this approach is comparable to determinations by magnetic resonance imaging and may be clinically useful in the management of pediatric patients.


Assuntos
Volume Cardíaco , Ecocardiografia , Função Ventricular Direita , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Angiografia Cintilográfica , Volume Sistólico
7.
Pediatr Cardiol ; 16(2): 90-4, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7784244

RESUMO

The pulmonary blood supply in patients with pulmonary atresia and ventricular septal defect is highly variable. Several cases have been reported in the literature in which a coronary artery to pulmonary artery fistula, alone or in combination with additional vessels, supplies the pulmonary circulation. We report a case of successful repair during early infancy, with unique hemodynamic, clinical, and anatomic features. The literature is reviewed.


Assuntos
Fístula Artério-Arterial/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Artéria Pulmonar/anormalidades , Atresia Pulmonar/diagnóstico por imagem , Fístula Artério-Arterial/cirurgia , Anomalias dos Vasos Coronários/cirurgia , Feminino , Seguimentos , Comunicação Interventricular/cirurgia , Hemodinâmica/fisiologia , Humanos , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Atresia Pulmonar/cirurgia , Radiografia
8.
Proc Natl Acad Sci U S A ; 79(14): 4298-302, 1982 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6956859

RESUMO

We describe a rapid "nonrandom" DNA sequence analysis procedure that facilitates the nucleotide sequence determination of large contiguous regions of DNA. The method consists of cloning a restriction endonuclease fragment of interest into bacteriophage M13 followed by construction of a series of nuclease BAL-31 deletion mutants originating from a single site in M13 that is close to the DNA insert. Determination of the size of the deletion mutant is accomplished by hybridization to a complementary single-stranded probe derived from M13 containing that total insert followed by nuclease S1 treatment. Single-stranded M13-insert DNAs of progressively smaller sizes are isolated and analyzed by using a site-specific M13 DNA primer and the dideoxy chain-termination method. In this way, analysis of the DNA sequence proceeds from one end of the total insert to the other in a nonrandom fashion due to generation of a controlled overlapping set of deletion mutants.


Assuntos
Sequência de Bases , Clonagem Molecular/métodos , Colífagos/genética , DNA , Deleção Cromossômica , DNA Recombinante , Globinas/genética , Humanos
9.
J Biol Chem ; 257(11): 5994-6, 1982 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-7076659

RESUMO

We recently described a "non-random" sequencing procedure for DNA inserts in bacteriophage M13 using Bal 3 nuclease and the dideoxy chain termination method (Poncz, M., Solowiejczyk, D., Ballantine, M., Schwartz, E., and Surrey, S. (1982) Proc. Natl. Acad. Sci. U. S. A., in press). Using this procedure, we have determined the nucleotide sequence of a cloned human beta-globin gene from a Kurdish Jew with beta +-thalassemia major. Comparison with the previously reported human beta-globin gene sequences (1-3) reveals a change in the "T-A-T-A" box. This region 5' to the capping site was previously demonstrated to be critical for the proper transcription in vitro of several different eukaryotic genes (4-7). This is the first report of a T-A-T-A box modification found in association with a spontaneously occurring human genetic disorder. In addition to this mutation, other base changes, an insertion, and a deletion in the cloned gene were found in the 5' and 3' flanking regions.


Assuntos
DNA/genética , Genes , Globinas/genética , Talassemia/genética , Sequência de Bases , Criança , Variação Genética , Humanos , Iraque/etnologia , Israel , Masculino
10.
Hemoglobin ; 6(1): 27-36, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-7068433

RESUMO

We describe a rapid procedure for constructing cloned human genomic libraries from small amounts of peripheral blood. High molecular weight DNA is isolated from 5-20 ml peripheral blood, partially cleaved with Eco R1, and 8-22 kb fragments are cloned using bacteriophage Charon 4A and suitable E. coli host. Using the approach we have isolated and characterized several non-alpha globin clones from a Kurdish Jew with homozygous beta thalassemia. The ability to isolate suitable amounts of high molecular weight DNA from peripheral blood provides a relatively simple means of constructing human gene libraries representing a variety of hemoglobin disorders.


Assuntos
Clonagem Molecular , Globinas/genética , Talassemia/genética , Sequência de Bases , Criança , DNA/isolamento & purificação , Homozigoto , Humanos , Masculino , Peso Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...