1.
BMC Med Imaging ; 23(1): 171, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37904089

RESUMO

A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59-75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3-24.9 HU vs. 27.4 HU; IQR, 24.2-31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8-21.8 vs. 13.7; IQR, 9.9-18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5-30.2 vs. 19.2; IQR, 14.1-23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61-0.78 mm vs. 0.81 mm; IQR, 0.72-0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65-2.26 mm vs. 1.52 mm; IQR, 1.28-2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study's initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Masculino , Humanos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Stents , Átrios do Coração , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
2.
Int Heart J ; 64(5): 839-846, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37704411

RESUMO

The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 ± 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-97], 94% [95% CI: 88-97], and 95% [95% CI: 90-97], respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic- and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase ECG-gated CT.


Assuntos
Síndrome Aórtica Aguda , Doenças da Aorta , Dissecção Aórtica , Masculino , Humanos , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Estudos Retrospectivos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia , Hematoma/cirurgia
3.
Pol J Radiol ; 88: e251-e255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37346423

RESUMO

Purpose: To correlate peripheral enhancement on contrast-enhanced computed tomography (CE-CT) in patients with post-chemotherapy colorectal liver metastases (CRLM) with the corresponding pathological findings. Material and methods: Forty-four patients with CRLM who underwent hepatic resection after preoperative chemotherapy between 2008 and 2013 were included. Two radiologists blinded to the histopathology findings performed a consensus categorization of the marginal contrast effects of CRLM on CE-CT as follows: Group 1, smooth margin without enhancement; Group 2, smooth margin with an enhanced rim; and Group 3, fuzzy margin with/without an enhanced rim. The Kruskal-Wallis test was used to compare the imaging findings with the histological findings. Results: The percentage of infarct-like necrosis was significantly higher in those with CRLM with smooth margins than in those with CRLM with fuzzy margins (p < 0.001, r = 0.62). The percentage of viable cells was lowest in CRLM with smooth margins without enhancement (p < 0.001, r = 0.60). Conclusions: Our findings suggest that the type of necrosis is related to the nature of the margins, and the presence of residual cells is related to peripheral enhancement.

4.
Int J Cardiovasc Imaging ; 39(5): 1001-1011, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36648573

RESUMO

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.


Assuntos
Aprendizado Profundo , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular
5.
PLoS One ; 14(12): e0226521, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31846490

RESUMO

The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients.


Assuntos
Abdome/diagnóstico por imagem , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Sobrepeso/diagnóstico por imagem , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...