RESUMO
A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59-75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3-24.9 HU vs. 27.4 HU; IQR, 24.2-31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8-21.8 vs. 13.7; IQR, 9.9-18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5-30.2 vs. 19.2; IQR, 14.1-23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61-0.78 mm vs. 0.81 mm; IQR, 0.72-0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65-2.26 mm vs. 1.52 mm; IQR, 1.28-2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study's initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.
Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Masculino , Humanos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Stents , Átrios do Coração , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de RadiaçãoRESUMO
The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 ± 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-97], 94% [95% CI: 88-97], and 95% [95% CI: 90-97], respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic- and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase ECG-gated CT.
Assuntos
Síndrome Aórtica Aguda , Doenças da Aorta , Dissecção Aórtica , Masculino , Humanos , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Estudos Retrospectivos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia , Hematoma/cirurgiaRESUMO
Purpose: To correlate peripheral enhancement on contrast-enhanced computed tomography (CE-CT) in patients with post-chemotherapy colorectal liver metastases (CRLM) with the corresponding pathological findings. Material and methods: Forty-four patients with CRLM who underwent hepatic resection after preoperative chemotherapy between 2008 and 2013 were included. Two radiologists blinded to the histopathology findings performed a consensus categorization of the marginal contrast effects of CRLM on CE-CT as follows: Group 1, smooth margin without enhancement; Group 2, smooth margin with an enhanced rim; and Group 3, fuzzy margin with/without an enhanced rim. The Kruskal-Wallis test was used to compare the imaging findings with the histological findings. Results: The percentage of infarct-like necrosis was significantly higher in those with CRLM with smooth margins than in those with CRLM with fuzzy margins (p < 0.001, r = 0.62). The percentage of viable cells was lowest in CRLM with smooth margins without enhancement (p < 0.001, r = 0.60). Conclusions: Our findings suggest that the type of necrosis is related to the nature of the margins, and the presence of residual cells is related to peripheral enhancement.
RESUMO
This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.
Assuntos
Aprendizado Profundo , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função VentricularRESUMO
The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients.