Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 10(5)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237594

RESUMO

Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.

2.
Ultrasonics ; 132: 107011, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37071943

RESUMO

Image guidance of extracorporeal shock wave therapy (ESWT) is important to enhance its efficacy while lowering pain in patients. Real-time ultrasound imaging is an appropriate modality for image guidance, but its image quality substantially reduces due to severe phase aberration from the different speed of sound between soft tissues and a gel pad, which is utilized to control a therapeutic focal point in ESWT. This paper presents a phase aberration correction method for improving image quality in the ultrasound imaging guided ESWT. To correct an error from phase aberration, a time delay based on a two-layer model with different speeds of sound is calculated for dynamic receive beamforming. For the phantom and in vivo studies, a rubber type gel pad (i.e., 1400 m/s) with a specific thickness (3 or 5-cm) was placed on the top of soft tissue and full scanline RF data were acquired. In the phantom study, with phase aberration correction, image quality was highly increased compared to image reconstructions with a fixed speed of sound (i.e., 1540 or 1400 m/s), i.e., 1.1 vs. 2.2 and 1.3 mm in -6dB lateral resolution and 0.64 vs. 0.61 and 0.56 in contrast-to-noise ratio (CNR), respectively. From an in vivo musculoskeletal (MSK) imaging, the phase aberration correction method provided a clearly improved depiction of muscle fibers in a rectus femoris region. These results indicate that the proposed method enables effective imaging guidance of ESWT by improving image quality of ultrasound imaging in real-time.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Humanos , Estudos de Viabilidade , Ultrassonografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
3.
Sensors (Basel) ; 22(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36081176

RESUMO

Inspecting the sealing integrity of lead tabs is an important means of ensuring the reliability and safety of pouch-type lithium-ion (Li-ion) batteries with a thin multi-layered aluminum (Al) laminated film. This paper presents a new air-coupled ultrasonic non-destructive testing (NDT) inspection method based on leaky Lamb wave transmission; and reception for evaluating the sealing integrity between the lead tab and the Al pouch film. The proposed method uses the critical incidence angle between the air and the layer with the fastest Lamb wave velocity to maximize the signal-to-noise ratio in the through-transmission mode. To determine the critical incidence angle, phantom experiments with two test pieces (i.e., an Al tab and an Al tab sealed with an Al pouch film) are conducted. In addition, 2D scans are performed at various incidence angles for an inhouse pouch-type Li-ion battery with a 1-mm-wide foreign material inserted as a defect. At the critical incidence angle (i.e., 22°), the proposed air-coupled ultrasonic NDT method in through-transmission mode successfully identifies the shape and location of the defect through c-scan image reconstruction. These preliminary results indicate that the proposed air-coupled ultrasonic NDT method with leaky Lamb waves can be used to inspect the sealing integrity of Li-ion pouch batteries in dry test conditions.

4.
Sci Rep ; 12(1): 2857, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-35190623

RESUMO

Multifocal Doppler twinkling artifact (MDTA) imaging has shown high detection rates of microcalcifications in phantom studies. We aimed to evaluate its performance in detecting suspicious microcalcifications in comparison with mammography by using ex vivo breast cancer specimens. We prospectively included ten women with breast cancer that presented with calcifications on mammography. Both digital specimen mammography and MDTA imaging were performed for ex vivo breast cancer specimens on the day of surgery. Five breast radiologists marked cells that included suspicious microcalcifications (referred to as 'positive cell') on specimen mammographic images using a grid of 5-mm cells. Cells that were marked by at least three readers were considered as 'consensus-positive'. Matched color Doppler twinkling artifact (CDTA) signals were compared between reconstructed US-MDTA projection images and mammographic images. The median detection rate for each case was 74.7% for positive cells and 96.7% for consensus-positive cells. Of the 10 cases, 90% showed a detection rate of ≥ 80%, with 50% of cases showing a 100% detection rate for consensus-positive cells. The proposed MDTA imaging method showed high performance for detecting suspicious microcalcifications in ex vivo breast cancer specimens, and may be a feasible approach for detecting suspicious breast microcalcifications with US.


Assuntos
Artefatos , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Manejo de Espécimes/métodos , Ultrassonografia Doppler/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
5.
IEEE Trans Med Imaging ; 41(5): 1300-1308, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34928792

RESUMO

Detecting microcalcifications (MCs) in real time is important in the guidance of many breast biopsies. Due to its capability in visualizing biopsy needles without radiation hazards, ultrasound imaging is preferred over X-ray mammography, but it suffers from low sensitivity in detecting MCs. Here, we present a new nonionizing method based on real-time multifocus twinkling artifact (MF-TA) imaging for reliably detecting MCs. Our approach exploits time-varying TAs arising from acoustic random scattering on MCs with rough or irregular surfaces. To obtain the increased intensity of the TAs from MCs, in MF-TA, acoustic transmit parameters, such as the transmit frequency, the number of focuses and f-number, were optimized by investigating acoustical characteristics of MCs. A real-time MF-TA imaging sequence was developed and implemented on a programmable ultrasound research system, and it was controlled with a graphical user interface during real-time scanning. From an in-house 3D phantom and ex vivo breast specimen studies, the MF-TA method showed outstanding visibility and high-sensitivity detection for MCs regardless of their distribution or the background tissue. These results demonstrated that this nonionizing, noninvasive imaging technique has the potential to be one of effective image-guidance methods for breast biopsy procedures.


Assuntos
Doenças Mamárias , Calcinose , Artefatos , Calcinose/diagnóstico por imagem , Humanos , Mamografia/métodos , Ultrassonografia
6.
Artigo em Inglês | MEDLINE | ID: mdl-32746224

RESUMO

Ultrafast power Doppler imaging based on coherent compounding (UPDI-CC) has become a promising technique for microvascular imaging due to its high sensitivity to slow blood flows. However, since this method utilizes a limited number of plane-wave or diverging-wave transmissions for high-frame-rate imaging, it suffers from degraded image quality because of the low contrast resolution. In this article, an ultrafast power Doppler imaging method based on a nonlinear compounding framework, called frame-multiply-and-sum (UPDI-FMAS), is proposed to improve contrast resolution. In UPDI-FMAS, unlike conventional channel-domain delay-multiply-and-sum (DMAS) beamforming, the signal coherence is estimated based on autocorrelation function over plane-wave angle frames. To avoid phase distortion of blood flow signals during the autocorrelation process, clutter filtering is preferentially applied to individual beamformed plane-wave data set. Therefore, only coherent blood flow signals are emphasized, while incoherent background noise is suppressed. The performance of the UPDI-FMAS was evaluated with simulation, phantom, and in vivo studies. For the simulation and phantom studies with a constant laminar flow, the UPDI-FMAS showed improvements in the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) to those of UPDI-CC, i.e., over 10 and 7 dB for 13 plane waves, respectively, and the performances were improved as the number of plane waves increased. Moreover, the enhancement of the image quality due to the increased SNR and CNR in UPDI-FMAS was more clearly depicted with the in vivo study, in which a human kidney and a tumor-bearing mouse were evaluated. These results indicate that the FMAS compounding can improve the image quality of UPDI for microvascular imaging without loss of temporal resolution.


Assuntos
Ultrassonografia Doppler , Animais , Simulação por Computador , Camundongos , Imagens de Fantasmas , Razão Sinal-Ruído , Ultrassonografia
7.
IEEE Trans Biomed Eng ; 67(6): 1638-1649, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31562069

RESUMO

Ultrafast ultrasound imaging provides great opportunities for very high frame rate applications, such as shear wave elastography and microvascular imaging. However, ultrafast imaging with curved array transducers remains challenging in terms of element directivity and a limited field-of-view (FOV) for a fully synthetic area. In this paper, a wide FOV ultrafast curved array imaging method based on diverging wave transmissions is presented for high frame rate abdominal ultrasound applications. For this method, a theoretical model for a diverging wave solution based on a virtual point source originating from a circular line is proposed, and the FOV and element directivity are analyzed by this model. Furthermore, an integrated model for plane wave and diverging wave imaging along the location of the virtual point source is derived. The proposed method was evaluated with simulation, phantom, and in vivo studies. In the simulation and phantom studies, the image quality (i.e., spatial resolution, cystic resolution, and contrast-to-noise ratio), and effective FOV were assessed. For the in vivo study, a preliminary result from abdominal microvascular imaging, where diverging wave excitation was utilized to depict the vasculature, was also presented. In the renal cortex microvessels, the diverging wave imaging yielded a higher signal-to-clutter ratio value than the plane wave imaging, i.e., 6.35 vs. 4.26 dB, due to the wider synthetic field. These studies demonstrated that the proposed ultrafast curved array imaging technique based on diverging wave excitation allowed for an extended FOV with high spatiotemporal resolution.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Transdutores , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...