Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
N Engl J Med ; 389(9): 808-819, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37646678

RESUMO

BACKGROUND: Population screening of asymptomatic persons with Epstein-Barr virus (EBV) DNA or antibodies has improved the diagnosis of nasopharyngeal carcinoma and survival among affected persons. However, the positive predictive value of current screening strategies is unsatisfactory even in areas where nasopharyngeal carcinoma is endemic. METHODS: We designed a peptide library representing highly ranked B-cell epitopes of EBV coding sequences to identify novel serologic biomarkers for nasopharyngeal carcinoma. After a retrospective case-control study, the performance of the novel biomarker anti-BNLF2b total antibody (P85-Ab) was validated through a large-scale prospective screening program and compared with that of the standard two-antibody-based screening method (EBV nuclear antigen 1 [EBNA1]-IgA and EBV-specific viral capsid antigen [VCA]-IgA). RESULTS: P85-Ab was the most promising biomarker for nasopharyngeal carcinoma screening, with high sensitivity (94.4%; 95% confidence interval [CI], 86.4 to 97.8) and specificity (99.6%; 95% CI, 97.8 to 99.9) in the retrospective case-control study. Among the 24,852 eligible participants in the prospective cohort, 47 cases of nasopharyngeal carcinoma (38 at an early stage) were identified. P85-Ab showed higher sensitivity than the two-antibody method (97.9% vs. 72.3%; ratio, 1.4 [95% CI, 1.1 to 1.6]), higher specificity (98.3% vs. 97.0%; ratio, 1.01 [95% CI, 1.01 to 1.02]), and a higher positive predictive value (10.0% vs. 4.3%; ratio, 2.3 [95% CI, 1.8 to 2.8]). The combination of P85-Ab and the two-antibody method markedly increased the positive predictive value to 44.6% (95% CI, 33.8 to 55.9), with sensitivity of 70.2% (95% CI, 56.0 to 81.4). CONCLUSIONS: Our results suggest that P85-Ab is a promising novel biomarker for nasopharyngeal carcinoma screening, with higher sensitivity, specificity, and positive predictive value than the standard two-antibody method. (Funded by the National Key Research and Development Program of China and others; ClinicalTrials.gov number, NCT04085900.).


Assuntos
Anticorpos Antivirais , Detecção Precoce de Câncer , Herpesvirus Humano 4 , Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Proteínas Virais , Humanos , Anticorpos Antivirais/imunologia , Estudos de Casos e Controles , Herpesvirus Humano 4/imunologia , Imunoglobulina A , Programas de Rastreamento , Carcinoma Nasofaríngeo/diagnóstico , Carcinoma Nasofaríngeo/imunologia , Carcinoma Nasofaríngeo/virologia , Neoplasias Nasofaríngeas/diagnóstico , Neoplasias Nasofaríngeas/imunologia , Neoplasias Nasofaríngeas/virologia , Estudos Prospectivos , Estudos Retrospectivos , Biomarcadores/análise , Proteínas Virais/imunologia , Epitopos/imunologia
2.
World J Gastroenterol ; 27(21): 2910-2920, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34135561

RESUMO

BACKGROUND: Persistent liver inflammatory damage is the main risk factor for developing liver fibrosis, cirrhosis, and even hepatocellular carcinoma in chronic hepatitis B (CHB) patients. Thus, accurate prediction of the degree of liver inflammation is a high priority and a growing medical need. AIM: To build an effective and robust non-invasive model for predicting hepatitis B-related hepatic inflammation. METHODS: A total of 650 treatment-naïve CHB (402 HBeAg-positive and 248 HBeAg-negative) patients who underwent liver biopsy were enrolled in this study. Histological inflammation grading was assessed by the Ishak scoring system. Serum quantitative hepatitis B core antibody (qAnti-HBc) levels and 21 immune-related inflammatory factors were measured quantitatively using a chemiluminescent microparticle immunoassay. A backward feature elimination (BFE) algorithm utilizing random forest (RF) was used to select optional features and construct a combined model. The diagnostic abilities of the model or variables were evaluated based on the estimated area under the receiver operating characteristics curve (AUROC) and compared using the DeLong test. RESULTS: Four features were selected to predict moderate-to-severe inflammation in CHB patients using the RF-BFE method. These predictive features included qAnti-HBc, ALT, AST, and CXCL11. Spearman's correlation analysis indicated that serum qAnti-HBc, ALT, AST, and CXCL11 levels were positively correlated with the histology activity index (HAI) score. These selected features were incorporated into the model to establish a novel model named I-3A index. The AUROC [0.822; 95% confidence interval (CI): 0.790-0.851] of the I-3A index was significantly increased compared with qAnti-HBc alone (0.760, 95%CI: 0.724-0.792, P < 0.0001) in all CHB patients. The use of an I-3A index cutoff value of 0.41 produced a sensitivity of 69.17%, specificity of 81.44%, and accuracy of 73.8%. Additionally, the I-3A index showed significantly improved diagnostic performance for predicting moderate-to-severe inflammation in HBeAg-positive and HBeAg-negative CHB patients (0.829, 95%CI: 0.789-0.865 and 0.810, 95%CI: 0.755-0.857, respectively). CONCLUSION: The selected features of the I-3A index constructed using the RF-BFE algorithm can effectively predict moderate-to-severe liver inflammation in CHB patients.


Assuntos
Hepatite B Crônica , Alanina Transaminase , Algoritmos , Biomarcadores , Antígenos E da Hepatite B , Vírus da Hepatite B/genética , Hepatite B Crônica/complicações , Hepatite B Crônica/diagnóstico , Humanos , Inflamação , Cirrose Hepática/diagnóstico , Curva ROC
3.
Hepatol Res ; 48(3): E133-E145, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28707778

RESUMO

AIM: Chronic hepatitis B (CHB) patients with normal alanine aminotransferase (ALT) levels are not free from significant hepatic lesions. Recently, there has been an improved understanding of the clinical significance of quantitative hepatitis B core antibody levels (qAnti-HBc) during CHB management. In this cross-sectional study, we evaluated the utility of qAnti-HBc in identifying significant liver inflammation in CHB patients. METHODS: A total of 469 patients (training set, n = 363; validation set, n = 106) who underwent liver biopsy (LB) were included. The qAnti-HBc levels were quantified and the relationship between histology and serum markers was systematically analyzed. RESULTS: In the training set, qAnti-HBc levels were found to have significant diagnostic value for moderate to severe liver inflammation (≥G2) in all patients (area under the receiver operating characteristic curve [AUROC] = 0.768; 95% confidence interval [CI], 0.721-0.810; P < 0.001) and in patients with normal or near-normal ALT levels (AUROC = 0.767; 95% CI, 0.697-0.828; P < 0.001). Our novel index (AC index) for the identification of ≥G2 inflammation, which combined the qAnti-HBc and ALT levels, significantly improved diagnostic performance (AUROC = 0.813; 95% CI, 0.768-0.852) compared to the use of ALT alone (AUROC = 0.779; 95% CI, 0.732-0.821) in all patients. In the validation set, the AC index showed an improved AUROC of 0.890 (95% CI, 0.814-0.942) and 0.867 (95% CI, 0.749-0.943) in all patients and patients with normal ALT levels, respectively. CONCLUSIONS: The qAnti-HBc level predicts significant liver inflammation well, even in patients with normal or near-normal ALT levels. Compared with the conventional ALT level, the AC index is a more reliable non-invasive biomarker for significant liver inflammation in CHB patients.

4.
Sheng Wu Gong Cheng Xue Bao ; 33(1): 141-150, 2017 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-28959871

RESUMO

The aim of this study is to develop creatine kinase isoenzyme MB (CK-MB) specific monoclonal antibodies (mAb), and characterize the monoclonal antibody and further development of quantitative detection assay for CK-MB. The BALB/c mice were immunized with purchased CK-MB antigen, then monoclonal antibodies were prepared according to conventional hybridoma technique and screened by indirect and capture ELISA method. To identify the epitopes and evaluate the classification, purchased creatine kinase isoenzyme MB (CK-MM/BB/MB) antigen was used to identify the epitopes, with immunoblotting and synthetic CK-MM and CK-BB in different linear epitope. A double antibody sandwich ELISA was applied to screen the mAb pairs for CK-MB detection, and the quantitative detection assay for CK-MB was developed. We used 74 cases of clinical specimens for comparison of our assay with Roche's CK-MB assay. We successfully developed 22 strains of hybridoms against CK-MB, these mAbs can be divided into linear, partial conformational CK-MB, CK-MM or CK-BB cross monoclonal antibody and CK-MB specific reaction with partial conformational monoclonal antibody, and CK-MB quantitative detection assay was developed by using partial conformational monoclonal antibody. The correlation coefficient factor r of our reagent and Roche's was 0.930 9. This study established a screening method for CK-MB partial conformational specific monoclonal antibody, and these monoclonal antibodies were analyzed and an established quantitative detection assay was developed. The new assay had a high concordance with Roche's.


Assuntos
Anticorpos Monoclonais , Creatina Quinase/imunologia , Epitopos , Hibridomas , Animais , Ensaio de Imunoadsorção Enzimática , Indicadores e Reagentes , Isoenzimas , Camundongos Endogâmicos BALB C
5.
Sci Rep ; 7(1): 2747, 2017 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-28584279

RESUMO

Our previous studies unexpectedly indicated that the level of serum hepatitis B core antibody (anti-HBc) was positively correlated with the serum alanine aminotransferase (ALT) level. The aim of this study was to determine whether anti-HBc could serve as a potential biomarker for the detection of liver inflammation in chronic hepatitis B (CHB) patients, especially in patients with normal ALT levels. Serum anti-HBc levels were quantified in 655 treatment-naïve CHB patients, including 45 patients who underwent two liver biopsies (baseline phase and the 78th weeks of antiviral-treatment). Serum anti-HBc levels increased significantly along with the increasing histology activity index (HAI) score. After antiviral-treatment, patients with HAI score reduction had significant decline in serum anti-HBc level. Multivariate analysis showed that anti-HBc was independently associated with moderate-to-severe hepatic inflammation in patients with normal ALT level. Furthermore, serum anti-HBc showed a high diagnostic accuracy for predicting moderate-to-severe inflammation in both hepatitis B e antigen (HBeAg)-positive and HBeAg-negative CHB patients with normal ALT levels (area under the curve, AUC = 0.87 and 0.75; respectively). Thus, anti-HBc may be a strong indicator for assessing the hepatic inflammatory degree and used for antiviral treatment decisions in CHB patients with normal ALT levels.


Assuntos
Alanina Transaminase/sangue , Biomarcadores , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Vírus da Hepatite B , Hepatite B Crônica/sangue , Adulto , Antivirais/uso terapêutico , DNA Viral , Feminino , Anticorpos Anti-Hepatite B/sangue , Anticorpos Anti-Hepatite B/imunologia , Antígenos E da Hepatite B/sangue , Vírus da Hepatite B/imunologia , Hepatite B Crônica/diagnóstico , Hepatite B Crônica/tratamento farmacológico , Hepatite B Crônica/virologia , Humanos , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença , Carga Viral
6.
Oncotarget ; 8(20): 33652-33657, 2017 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-28430588

RESUMO

Chronic stress triggers rigorous psychological and physiological changes, including immunological system adaptations. However, the effects of long-term social restriction on human immune system have not been investigated. The present study is to investigate the effect of chronic stress on immune changes in human blood, with the stress stimuli controlled.10 male volunteers were group isolated from the modern society in a 50-meter-square room for 150 days, with enriched nutrition and good living conditions provided. Serum examination of immune system markers demonstrated numerous changes in different aspects of the immune functions. The changes were observed as early as 30 days and could last for another 150 days after the termination of the restriction period (300 days' time point). The results strongly argued for the adaptation of immunological system under chronic social restriction stress in adult human, preceding a clear change in psychological conditions. The changes of these immune system factors could as well act as the serum biomarkers in clinical early-diagnosis of stress-related disorders.


Assuntos
Adaptação Fisiológica/imunologia , Sistema Imunitário , Meio Social , Estresse Psicológico/imunologia , Adolescente , Adulto , Biomarcadores , Citocinas/sangue , Citocinas/metabolismo , Humanos , Hidrocortisona/sangue , Hidrocortisona/metabolismo , Sistema Imunitário/citologia , Sistema Imunitário/imunologia , Sistema Imunitário/metabolismo , Masculino , Estresse Psicológico/sangue , Estresse Psicológico/metabolismo , Fatores de Tempo , Adulto Jovem
7.
SLAS Technol ; 22(2): 122-129, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27899699

RESUMO

We reported a rapid, convenient, and easy-to-use genotyping method for hepatitis B virus (HBV) based on the smartphone at point-of-care (POC) settings. To perform HBV genotyping especially for genotypes A, B, C, and D, a smartphone is used to image and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines. A light-emitting diode (LED) positioned on the top of the lateral flow strip is used to shine the multiple capture lines for excitation. Fluorescence detection is obtained with a smartphone whose camera is used to take the fluorescent images. An intelligent algorithm is developed to first identify each capture line from the fluorescent image and then determine the HBV genotype based on a genotyping model. Based on the pattern of the detection signal from different samples, a custom HBV genotyping model is developed. Custom application software running on a smartphone is developed with Java to collect and analyze the fluorescent image, display the genotyping result, and transmit it if necessary. Compared with the existing methods with nucleic acid analysis, more convenient, instant, and efficient HBV genotyping with significantly lower cost and a simpler procedure can be obtained with the developed smartphone POC HBV genotyping method.


Assuntos
Cromatografia de Afinidade/métodos , Técnicas de Genotipagem/métodos , Vírus da Hepatite B/classificação , Vírus da Hepatite B/genética , Hepatite B/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Smartphone , Humanos , Processamento de Imagem Assistida por Computador , Imagem Óptica , Software
8.
Sci Rep ; 6: 28274, 2016 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-27306485

RESUMO

A fast and low-cost method for HBV genotyping especially for genotypes A, B, C and D was developed and tested. A classifier was used to detect and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines in the form of pattern recognition for point-of-care (POC) diagnostics. The fluorescent signals from the capture lines and the background of the strip were collected via multiple optical channels in parallel. A digital HBV genotyping model, whose inputs are the fluorescent signals and outputs are a group of genotype-specific digital binary codes (0/1), was developed based on the HBV genotyping strategy. Meanwhile, a companion decoding table was established to cover all possible pairing cases between the states of a group of genotype-specific digital binary codes and the HBV genotyping results. A logical analyzing module was constructed to process the detected signals in parallel without program control, and its outputs were used to drive a set of LED indicators, which determine the HBV genotype. Comparing to the nucleic acid analysis to HBV viruses, much faster HBV genotyping with significantly lower cost can be obtained with the developed method.


Assuntos
Genótipo , Vírus da Hepatite B/genética , Sistemas Automatizados de Assistência Junto ao Leito , Estudos de Coortes , Hepatite B Crônica/sangue , Hepatite B Crônica/diagnóstico , Hepatite B Crônica/virologia , Humanos
9.
J Virol Methods ; 234: 96-100, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27091097

RESUMO

The stable HBV-replicating cell lines, which carry replication-competent HBV genome stably integrated into the genome of host cell, are widely used to evaluate the effects of antiviral agents. However, current methods to generate HBV-replicating cell lines, which are mostly dependent on random integration of foreign DNA via plasmid transfection, are less-efficient and time-consuming. To address this issue, we constructed an all-in-one Sleeping Beauty transposon system (denoted pTSMP-HBV vector) for robust generation of stable cell lines carrying replication-competent HBV genome of different genotype. This vector contains a Sleeping Beauty transposon containing HBV 1.3-copy genome with an expression cassette of the SV40 promoter driving red fluorescent protein (mCherry) and self-cleaving P2A peptide linked puromycin resistance gene (PuroR). In addition, a PGK promoter-driven SB100X hyperactive transposase cassette is placed in the outside of the transposon in the same plasmid.The HBV-replicating stable cells could be obtained from pTSMP-HBV transfected HepG2 cells by red fluorescence-activated cell sorting and puromycin resistant cell selection within 4-week. Using this system, we successfully constructed four cell lines carrying replication-competent HBV genome of genotypes A-D. The replication and viral protein expression profiles of these cells were systematically characterized. In conclusion, our study provides a high-efficiency strategy to generate HBV-replicating stable cell lines, which may facilitate HBV-related virological study.


Assuntos
Vírus da Hepatite B/fisiologia , Transposases/genética , Replicação Viral , Técnicas de Cultura , Replicação do DNA , Citometria de Fluxo , Técnicas de Transferência de Genes , Vetores Genéticos , Células HeLa , Células Hep G2 , Vírus da Hepatite B/genética , Humanos , Proteínas Luminescentes , Proteína Vermelha Fluorescente
10.
J Virol Methods ; 228: 55-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26615806

RESUMO

Hepatitis B virus surface antigen (HBsAg) is an important biomarker used in the diagnosis of hepatitis B virus (HBV) infection, but false-negative results are still reported in the detection of HBsAg using commercial assays. In this study, we evaluated the qualitative properties of a novel HBsAg chemiluminescence enzyme immunoassay (CLEIA) assay--WTultra. WHO standard sample dilution series and samples from low-level HBsAg carriers (<1 ng/mL) were used to evaluate the sensitivity of the WTultra assay. Boston Biomedica, Inc. (BBI) hepatitis B seroconversion panels were used to assess the ability of the WTultra assay to detect the window period. In addition, dilution series of 22 serum samples with different genotypes, serotypes and HBsAg mutations were used to assess the WTultra assay, and these were compared with other commercial assays. The lower detection limit of the WTultra assay was 0.012 IU/mL, and it showed a high sensitivity (97.52%, 95% CI, 94.95-99.00) in the detection of 282 low-level HBsAg carriers (<1 ng/mL). In samples with various HBV genotypes, serotypes and HBsAg mutations, the WTultra assay yielded 117 positive results in 132 samples, which was significantly higher than the results with the other four commercial assays (89, 83, 65 and 45, respectively, p<0.01). In the assays of mutant strains, the WTultra assay detected 82 positive results in 90 samples, which was significantly better than the results for the Hepanostika HBsAg Ultra (58 positive) and Architect (55 positive) (p<0.01) assays, which in turn were significantly better than the Murex V.3 (41 positive, p=0.026) and AxSYM V2 (29 positive, p<0.01) assays. However, in the detection of 42 samples of wild-type strains with various genotypes and serotypes, no significant differences were observed among the WTultra (35 positive), Architect (28 positive) and Hepanostika HBsAg Ultra (31 positive) assays. However, the WTultra assay detected significantly more samples than the Murex V.3 (24 positive, p<0.01) and AxSYM V2 (16 positive, p<0.01) assays. In conclusion, the WTultra HBsAg assay has a high detection sensitivity and presents excellent results for the detection of mutants.


Assuntos
Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Técnicas Imunoenzimáticas , DNA Viral/genética , Genótipo , Hepatite B/virologia , Antígenos de Superfície da Hepatite B/genética , Antígenos de Superfície da Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Humanos , Técnicas Imunoenzimáticas/instrumentação , Técnicas Imunoenzimáticas/métodos , Limite de Detecção , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Mutação , Sensibilidade e Especificidade , Sorogrupo
11.
Sheng Wu Gong Cheng Xue Bao ; 32(12): 1694-1703, 2016 Dec 25.
Artigo em Chinês | MEDLINE | ID: mdl-29034637

RESUMO

The aim of this study is to prepare and characterize cardiac troponin T (cTnT) monoclonal antibodies (mAb), and further develop a chemiluminescence quantitative detection assay for cTnT. BALB/c mice were immunized with recombinant cTnT antigen, and specific mAbs were prepared using conventional hybridoma technique and screened by indirect ELISA method. To identify the epitopes, several cTnT peptide fragments were synthesized or expressed by genetic engineering. A double antibody sandwich ELISA method was used to screen the mAb pairs for cTnT detection, and the automatic chemiluminescence detection assay for cTnT was developed. In total 220 clinical specimens were used for system comparison between our assay and Roche cTnT assay; further performance characteristics was evaluated by testing 238 clinical samples and 784 physical examination samples. We successfully screened 33 strains of hybridoms against cTnT, and the mAbs' epitopes were identified. Mab E16H8 and C8G11 with a detection limit of 10 pg/mL cTnT antigen were selected to develop the full automatic chemiluminescence quantitative assay. The correlation coefficient of our reagent with Roche's was 0.959 9, with a coincidence rate of 95%. The assay presented a sensitivity of 97.5%, and a specificity of 99.15% in detection of clinical samples. The cTnT concentration was less than 0.080 6 ng/mL in 99% of general population, which agrees with the definition of WHO on patients with acute myocardial infarction (AMI). In summary, we developed monoclonal antibodies against predominant epitopes for diagnostics of cTnT, and an automatic tubular chemiluminescence quantitative detection assay was further developed, which presents a high coincidence rate with Roche's.


Assuntos
Anticorpos Monoclonais/imunologia , Hibridomas , Troponina T/imunologia , Ensaio de Imunoadsorção Enzimática , Epitopos/imunologia , Humanos , Medições Luminescentes , Infarto do Miocárdio , Fragmentos de Peptídeos , Sensibilidade e Especificidade
12.
PLoS One ; 10(6): e0130209, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26115521

RESUMO

Non invasive immunologic markers of virus-induced liver disease are unmet needs. We tested the clinical significance of quantitative total and IgM-anti-HBc in well characterized chronic-HBsAg-carriers. Sera (212) were obtained from 111 HBsAg-carriers followed-up for 52 months (28-216) during different phases of chronic-HBV-genotype-D-infection: 10 HBeAg-positive, 25 inactive-carriers (HBV-DNA≤2000IU/ml, ALT<30U/L), 66 HBeAg-negative-CHB-patients and 10 with HDV-super-infection. In 35 patients treated with Peg-IFN±nucleos(t)ide-analogues (NUCs) sera were obtained at baseline, end-of-therapy and week-24-off-therapy and in 22 treated with NUCs (for 60 months, 42-134m) at baseline and end-of-follow-up. HBsAg and IgM-anti-HBc were measured by Architect-assays (Abbott, USA); total-anti-HBc by double-antigen-sandwich-immune-assay (Wantai, China); HBV-DNA by COBAS-TaqMan (Roche, Germany). Total-anti-HBc were detectable in all sera with lower levels in HBsAg-carriers without CHB (immune-tolerant, inactive and HDV-superinfected, median 3.26, range 2.26-4.49 Log10 IU/ml) versus untreated-CHB (median 4.68, range 2.76-5.54 Log10 IU/ml), p<0.0001. IgM-anti-HBc positive using the chronic-hepatitis-cut-off" (0.130-S/CO) were positive in 102 of 212 sera (48.1%). Overall total-anti-HBc and IgM-anti-HBc correlated significantly (p<0.001, r=0.417). Total-anti-HBc declined significantly in CHB patients with response to Peg-IFN (p<0.001) and in NUC-treated patients (p<0.001); the lowest levels (median 2.68, range 2.12-3.08 Log10 IU/ml) were found in long-term responders who cleared HBsAg subsequently. During spontaneous and therapy-induced fluctuations of CHB (remissions and reactivations) total- and IgM-anti-HBc correlated with ALT (p<0.001, r=0.351 and p=0.008, r=0.185 respectively). Total-anti-HBc qualifies as a useful marker of HBV-induced-liver-disease that might help to discriminate major phases of chronic HBV infection and to predict sustained response to antivirals.


Assuntos
Anticorpos Anti-Hepatite B/sangue , Anticorpos Anti-Hepatite B/imunologia , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Hepatite B/sangue , Hepatite B/imunologia , Adulto , Idoso , Antivirais/uso terapêutico , Biomarcadores , Portador Sadio , Feminino , Hepatite B/tratamento farmacológico , Hepatite B/virologia , Hepatite B Crônica/sangue , Hepatite B Crônica/tratamento farmacológico , Hepatite B Crônica/imunologia , Hepatite B Crônica/virologia , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Carga Viral , Adulto Jovem
13.
Anal Chem ; 87(10): 5173-80, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25892477

RESUMO

Hepatitis B virus (HBV) genotyping plays an important role in the clinical management of chronic hepatitis B (CHB) patients. However, the current nucleic acid based techniques are expensive, time-consuming, and inconvenient. Here, we developed a novel DNA-independent HBV genotyping tool based on a one-step fluorescent lateral flow immunoassay (LFIA). Epitope-targeting immunization and screening techniques were used to develop HBV genotype specific monoclonal antibodies (mAbs). These mAbs were used to develop a multitest LFIA with a matched scanning luminoscope for HBV genotyping (named the GT-LFIA). The performance of this novel assay was carefully evaluated in well-characterized clinical cohorts. The GT-LFIA, which can specifically differentiate HBV genotypes A, B, C, and D in a pretreatment-free single test, was successfully developed using four genotype specific mAbs. The detection limits of the GT-LFIA for HBV genotypes A, B, C, and D were 2.5-10.0 IU HBV surface antigen/mL, respectively. Among the sera from 456 CHB patients, 439 (96.3%; 95% confidence interval (CI), 94.1-97.8%) were genotype-differentiable by the GT-LFIA and 437 (99.5%; 95% CI, 98.4-99.9%) were consistent with viral genome sequencing. In the 21 patients receiving nucleos(t)ide analogue therapy, for end-of-treatment specimens that were HBV DNA undetectable and were not applicable for DNA-dependent genotyping, the GT-LFIA presented genotyping results that were consistent with those obtained in pretreatment specimens by viral genome sequencing and the GT-LFIA. In conclusion, the novel GT-LFIA is a convenient, fast, and reliable tool for differential HBV genotyping, especially in patients with low or undetectable HBV DNA levels.


Assuntos
Técnicas de Genotipagem/métodos , Vírus da Hepatite B/genética , Imunoensaio/métodos , Sequência de Aminoácidos , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Especificidade de Anticorpos , Antígenos de Superfície da Hepatite B/análise , Antígenos de Superfície da Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Vírus da Hepatite B/fisiologia , Hepatite B Crônica/virologia , Humanos , Dados de Sequência Molecular , Espectrometria de Fluorescência , Fatores de Tempo
14.
Theranostics ; 5(3): 218-26, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25553110

RESUMO

A recent study revealed that quantitative hepatitis B core antibody (qAnti-HBc) level could serve as a novel marker for predicting treatment response. In the present study, we further investigated the predictive value of qAnti-HBc level in HBeAg-positive patients undergoing PEG-IFN therapy. A total of 140 HBeAg-positive patients who underwent PEG-IFN therapy for 48 weeks and follow-up for 24 weeks were enrolled in this study. Serum samples were taken every 12 weeks post-treatment. The predictive value of the baseline qAnti-HBc level for treatment response was evaluated. Patients were further divided into 2 groups according to the baseline qAnti-HBc level, and the response rate was compared. Additionally, the kinetics of the virological and biochemical parameters were analyzed. Patients who achieved response had a significantly higher baseline qAnti-HBc level (serological response [SR], 4.52±0.36 vs. 4.19±0.58, p=0.001; virological response [VR], 4.53±0.35 vs. 4.22±0.57, p=0.005; combined response [CR], 4.50±0.36 vs. 4.22±0.58, p=0.009)). Baseline qAnti-HBc was the only parameter that was independently correlated with SR (p=0.008), VR (p=0.010) and CR(p=0.019). Patients with baseline qAnti-HBc levels ≥30,000 IU/mL had significantly higher response rates, more HBV DNA suppression, and better hepatitis control in PEG-IFN treatment. In conclusion, qAnti-HBc level may be a novel biomarker for predicting treatment response in HBeAg-positive patients receiving PEG-IFN therapy.


Assuntos
Monitoramento de Medicamentos/métodos , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Antígenos E da Hepatite B/sangue , Hepatite B Crônica/diagnóstico , Hepatite B Crônica/tratamento farmacológico , Interferon-alfa/uso terapêutico , Adulto , Biomarcadores/sangue , DNA Viral/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Carga Viral , Adulto Jovem
15.
Medicine (Baltimore) ; 93(29): e322, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25546679

RESUMO

Previous studies have revealed antibody to hepatitis B core antigen (anti-HBc) levels as a predictor of treatment response in hepatitis B early antigen (HBeAg)-positive chronic hepatitis B (CHB) patients in both interferon and nucleos(t)ide analog therapy cohorts. However, there is no information about anti-HBc levels in the natural history of CHB. This study aimed to define anti-HBc levels of different phases in the natural history of CHB. Two hundred eleven treatment-naive CHB patients were included in the study. They were classified into 4 phases: immune tolerance (IT) phase (n = 39), immune clearance (IC) phase (n = 48), low or no-replicative (LR) phase (n = 55), and HBeAg-negative hepatitis (ENH, n = 69). Fifty patients who were HBsAg negative and anti-HBc positive were also recruited as past HBV infection (PBI) control group. Anti-HBc levels were measured by a newly developed double-sandwich immunoassay. Correlation of anti-HBc levels with alanine aminotransferase (ALT) and other HBV-related markers within each phase was performed. Serum anti-HBc levels were statistically significant between patients in different phases of CHB (P < 0.001). The median anti-HBc levels were: IT (3.17 log 10 IU/mL), IC (4.39 log 10 IU/mL), LR (3.29 log 10 IU/mL), ENH (4.12 log 10 IU/mL), and PBI (0.61 log 10 IU/mL). There existed a strong correlation in IC (r = 0.489, P < 0.001), a poor correlation in ENH (r = 0.275, P = 0.042), and no correlation in patients with ALT reached 5 times upper limit of normal (r = 0.120, P = 0.616). Anti-HBc levels show significant differences during the natural course of CHB. These results may provide some potentially useful insights into hepatitis B pathogenesis and immune activation against hepatitis B virus.


Assuntos
Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Hepatite B Crônica/imunologia , Adolescente , Adulto , Idoso , Alanina Transaminase/sangue , Estudos de Casos e Controles , DNA Viral/análise , Feminino , Vírus da Hepatite B/genética , Vírus da Hepatite B/imunologia , Humanos , Tolerância Imunológica , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
16.
Clin Vaccine Immunol ; 21(11): 1521-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25209557

RESUMO

Hepatitis B surface antigen (HBsAg) quantification has garnered attention because of its high predictive value in determining treatment responses. The HBsAg quantification assays, such as Architect and Elecsys, are commercially available, and more assays are in development. We aimed to compare the results of the Architect and Elecsys assays with those of a new assay, WTultra. The WTultra HBsAg assay is a sandwich chemiluminescent microplate enzyme immunoassay and provides an alternative choice which is more cost-effective and potentially applicable in developing or resource-constrained countries and areas. A total of 411 serum samples were collected from patients during various phases of chronic hepatitis B (CHB) infection. The samples were assessed using the three assays, and the results were compared and analyzed. The results for the Architect, Elecsys, and WTultra assays were well correlated according to the overall results for the samples (correlation coefficients, rArchitect versus WTultra = 0.936, rArchitect versus Elecsys = 0.952, and rWTultra versus Elecsys = 0.981) and the various infection phases (rArchitect versus WTultra ranging from 0.67 to 0.975, rArchitect versus Elecsys ranging from 0.695 to 0.982, and rWTultra versus Elecsys ranging from 0.877 to 0.99). Additionally, consistent results were observed according to genotype (genotype B: rArchitect versus WTultra = 0.976, rArchitect versus Elecsys = 0.978, and rWTultra versus Elecsys = 0.979; genotype C: rArchitect versus WTultra = 0.950, rArchitect versus Elecsys = 0.963, and rWTultra versus Elecsys = 0.981) and hepatitis B virus (HBV) DNA levels (rArchitect = 0.540, rWTultra = 0.553, and rElecsys = 0.580). In conclusion, the Elecsys and WTultra assays were well correlated with the Architect assay, irrespective of the CHB infection phase or genotype. All of these assays are reliable for HBsAg quantification.


Assuntos
Antígenos de Superfície da Hepatite B/sangue , Hepatite B Crônica/virologia , Medições Luminescentes/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Imunoensaio/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...