Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Imaging (Bellingham) ; 10(3): 033505, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37351312

RESUMO

Purpose: Minimally invasive surgery has advantages in terms of quality of life and patient outcomes. Recently, near-infrared (NIR) fluorescence guided surgery has widely used for preclinical and clinical trials. However, NIR fluorescence has a maximum penetration capability of 10 mm. Radiographic imaging can be a solution to overcome the depth issue of NIR fluorescence. For this reason, the performance of the multimodal imaging system, which integrates annihilation gamma (511 keV) rays, NIR fluorescence, and color images, was evaluated. Approach: The multimodal imaging system consisted of a laparoscopic module, containing an internal detector for annihilation gamma events and cameras for optical imaging, and a flat module for coincidence detection with the internal detector. The acquired images were integrated by an algorithm with post image processing and registration. To evaluate the performance of the proposed multimodal imaging system, the images of a resolution target, a square bar target filled with a fluorescence dye, and a sodium-22 point source were analyzed. A preclinical test for axillary sentinel lymph node (SLN) biopsy with a rat model was conducted. Results: The spatial resolution of color images was equivalent to 4 lp/mm. The modulation transfer function of NIR fluorescence at 1 lp/mm was 0.83. The 511 keV gamma sensitivity and spatial resolution of the point source were 0.54 cps/kBq and 2.1 mm, respectively. The image of 511 keV gamma rays showed almost the same intensity regardless of the thickness of the tissue phantom. In the preclinical test, an integrated image of the SLN sample of the rat model was obtained with the proposed multimodal imaging system. Conclusions: With the proposed laparoscopic system, a merged image of the sample was obtained with the rat model. The annihilation gamma rays showed penetration capability with the tissue-mimicking phantom superior to that of NIR fluorescence.

2.
Opt Express ; 29(2): 2364-2377, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726432

RESUMO

Intraoperative imaging has been studied using conventional devices such as near infrared (NIR) optical probes and gamma probes. However, these devices have limited depth penetration and spatial resolution. In a previous study, we realized a multi-modal endoscopic system. However, charge-coupled device (CCD)-based gamma imaging required long acquisition times and lacked gamma energy information. A silicon photomultiplier (SiPM)-based gamma detector is implemented in a multi-modal laparoscope herein. A gradient index (GRIN) lens and CCD are used to transfer and readout visible and NIR photons. The feasibility of in-vivo sentinel lymph node (SLN) mapping was successfully performed with the proposed system.


Assuntos
Corantes/química , Câmaras gama , Verde de Indocianina/química , Laparoscópios , Cintilografia/instrumentação , Linfonodo Sentinela/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Animais , Raios gama , Ratos , Ratos Sprague-Dawley , Agregado de Albumina Marcado com Tecnécio Tc 99m
3.
Biomed Phys Eng Express ; 6(6)2020 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-34035192

RESUMO

Silicon photomultipliers (SiPMs) are now widely used for positron emission tomography (PET) applications because of their high gain and low noise characteristics. The PET image quality has been improved with the advancement of time-of-flight (TOF) and depth-of-interaction (DOI) measurement techniques. For brain-dedicated PET systems, both TOF and DOI information are beneficial for enhancing the reconstructed PET image quality. In a previous study, we proposed SiPM-based dual-ended readout PET detectors that used a mean time method to achieve coincidence timing resolution (CTR) of 349 ps and DOI resolution of 2.9 mm. However, the coincidence timing resolution (CTR) was worse than 300 ps since the crystal surface and the reflector type were not optimized. This study aimed at investigating the optimal crystal surface treatment and the reflector material to achieve a sub-200 ps CTR and sub-3 mm DOI resolution with a dual-ended readout PET detector using an LYSO crystal (2.9 × 2.9 × 20 mm3). The scintillation light inside the LYSO crystal was read out by two SiPMs using the dual-ended readout method. The CTR and DOI resolution were measured with two different crystal surfaces (polished and saw-cut) and three different reflector material scenarios of ESR without grease (i.e., air coupling), ESR with optical grease and Teflon. We digitized the timing and energy signals by using a V775N TDC module (35 ps bit-1) and V965 QDC module, respectively. The combination of the saw-cut LYSO crystal and the ESR with air coupling resulted in the best CTR (188 ± 32 ps) and DOI resolution (2.9 ± 0.2 mm) with the dual-ended readout configuration. We concluded the dual-ended readout method in combination with the saw-cut crystal and the ESR reflector with air coupling can provide a sub-200 ps CTR and sub-3.0 mm DOI resolution simultaneously.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons
4.
Opt Express ; 26(7): 8325-8339, 2018 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-29715801

RESUMO

An optical/nuclear hybrid surgical technique using ICG-99mTc-nanocolloid can improve lesion detectability by detecting both fluorescence and gamma signals. However, a hybrid multimodal laparoscope that can obtain both NIR and gamma images is not available yet. In this work, we present a proof-of-concept study of a prototype multimodal laparoscope that can provide simultaneous NIR/gamma/visible imaging using wavelength division multiplexing. The performances of optical and gamma imaging were evaluated using a USAF 1951 negative resolution target and 99mTc-filled tumor-like sources, respectively. Simultaneous NIR/gamma/visible images of two Eppendorf tubes containing a mixture of 99mTc-ICG are presented.


Assuntos
Raios gama , Raios Infravermelhos , Laparoscópios , Imagem Molecular/métodos , Imagem Multimodal/instrumentação , Imagens de Fantasmas , Verde de Indocianina/química , Imagem Multimodal/métodos , Agregado de Albumina Marcado com Tecnécio Tc 99m/química
5.
J Biomed Opt ; 23(2): 1-13, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29446262

RESUMO

Optical imaging techniques are widely used for in vivo preclinical studies, and it is well known that the Geant4 Application for Emission Tomography (GATE) can be employed for the Monte Carlo (MC) modeling of light transport inside heterogeneous tissues. However, the GATE MC toolkit is limited in that it does not yet include optical lens implementation, even though this is required for a more realistic optical imaging simulation. We describe our implementation of a biconvex lens into the GATE MC toolkit to improve both the sensitivity and spatial resolution for optical imaging simulation. The lens implemented into the GATE was validated against the ZEMAX optical simulation using an US air force 1951 resolution target. The ray diagrams and the charge-coupled device images of the GATE optical simulation agreed with the ZEMAX optical simulation results. In conclusion, the use of a lens on the GATE optical simulation could improve the image quality of bioluminescence and fluorescence significantly as compared with pinhole optics.


Assuntos
Simulação por Computador , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Desenho de Equipamento , Método de Monte Carlo , Imagens de Fantasmas , Reprodutibilidade dos Testes
6.
Med Phys ; 44(1): 227-239, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28102947

RESUMO

PURPOSE: The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using gamma imaging and to demonstrate the feasibility of endoscopic NIR/gamma/visible fusion imaging for sentinel lymph node (SLN) mapping with a small animal. METHODS: The endoscopic NIR/gamma/visible imaging system consists of a tungsten pinhole collimator, a plastic focusing lens, a BGO crystal (11 × 11 × 2 mm3 ), a fiber-optic taper (front = 11 × 11 mm2 , end = 4 × 4 mm2 ), a 122-cm long endoscopic fiber bundle, an NIR emission filter, a relay lens, and a CCD camera. A custom-made Derenzo-like phantom filled with a mixture of 99m Tc and indocyanine green (ICG) was used to assess the spatial resolution of the NIR and gamma images. The ICG fluorophore was excited using a light-emitting diode (LED) with an excitation filter (723-758 nm), and the emitted fluorescence photons were detected with an emission filter (780-820 nm) for a duration of 100 ms. Subsequently, the 99m Tc distribution in the phantom was imaged for 3 min. The feasibility of in vivo SLN mapping with a mouse was investigated by injecting a mixture of 99m Tc-antimony sulfur colloid (12 MBq) and ICG (0.1 mL) into the right paw of the mouse (C57/B6) subcutaneously. After one hour, NIR, gamma, and visible images were acquired sequentially. Subsequently, the dissected SLN was imaged in the same way as the in vivo SLN mapping. RESULTS: The NIR, gamma, and visible images of the Derenzo-like phantom can be obtained with the proposed endoscopic imaging system. The NIR/gamma/visible fusion image of the SLN showed a good correlation among the NIR, gamma, and visible images both for the in vivo and ex vivo imaging. CONCLUSION: We demonstrated the feasibility of the integrated NIR/gamma/visible imaging system using a single endoscopic fiber bundle. In future, we plan to investigate miniaturization of the endoscope head and simultaneous NIR/gamma/visible imaging with dichroic mirrors and three CCD cameras.


Assuntos
Endoscopia/métodos , Raios gama , Imagem Molecular/métodos , Imagem Multimodal/métodos , Linfonodo Sentinela/diagnóstico por imagem , Animais , Endoscopia/instrumentação , Estudos de Viabilidade , Camundongos , Imagem Molecular/instrumentação , Imagem Multimodal/instrumentação , Tecnécio
7.
BMC Anesthesiol ; 16: 16, 2016 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-26971194

RESUMO

BACKGROUND: Recent studies have reported that cancer surgeries involving regional anesthesia have better outcomes than those under general anesthesia. However, the effects of anesthetic technique have not been investigated in patients with bladder cancer. Therefore, this retrospective study was conducted to investigate which anesthetic technique results in a better bladder cancer prognosis. METHODS: Sixty-one of 531 patients underwent transurethral resection of a bladder tumor under general anesthesia from 2001 to 2008 in our hospital. Patients who attended five years of follow-up and who had pathological findings of urothelial carcinoma grades I-II were enrolled. Finally, 24 patients (G group) who underwent general anesthesia and 137 (R group) who underwent regional (spinal or epidural) anesthesia were compared. Five-year survival and recurrence-free time were compared using the chi-square and t-tests, respectively. A logistic regression and partial correlation analysis were performed to evaluate other factors affecting survival. RESULTS: Five-year survival was 87.5% for general anesthesia and 96.3% for regional (P = 0.099). The regression analysis showed that older age contributed to reduced survival (odds ratio = 0.85, P = 0.001). Regional anesthesia showed higher 5-year survival (coefficient = -0.167, P = 0.044) more than general anesthesia through the partial correlation analysis. CONCLUSIONS: Though partial correlation analysis show that five-year survival is higher in patients whose surgery is under regional than general anesthesia, the association was not significant in the chi-square test and logistic regression analysis. Large prospective studies are needed to determine whether the association between regional anesthesia and survival is causative.


Assuntos
Anestesia por Condução/mortalidade , Anestesia Geral/mortalidade , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/cirurgia , Uretra/cirurgia , Neoplasias da Bexiga Urinária/mortalidade , Neoplasias da Bexiga Urinária/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anestesia por Condução/tendências , Anestesia Geral/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...