Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artif Cells Nanomed Biotechnol ; 44(7): 1708-13, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26508304

RESUMO

Poly(2-hydroxyethyl methacrylate-glycidyl methacrylate) [p(HEMA-GMA)] cryogel discs were prepared under sub-zero temperatures. Gelatin was attached covalently on the p(HEMA-GMA) cryogel discs and reversible immobilization of horseradish peroxidase (HRP) was performed. The p(HEMA-GMA) cryogel discs were characterized by swelling tests, scanning electron microscopy, and surface area measurements. HRP immobilization capacity of p(HEMA-GMA)/gelatin cryogel discs was 24.8 mg/g. Removal of phenol from aqueous solutions was performed using HRP immobilized p(HEMA-GMA)/gelatin cryogel. It was observed that within 2 h of contact time, the percentage of phenol removal reaches up to 91% in the presence of H2O2.


Assuntos
Criogéis/química , Gelatina/química , Poli-Hidroxietil Metacrilato/análogos & derivados , Poli-Hidroxietil Metacrilato/química , Enzimas Imobilizadas/química , Peroxidase do Rábano Silvestre/química
2.
ScientificWorldJournal ; 2012: 418047, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22654605

RESUMO

A very simple, selective, and fast flow injection spectrophotometeric method is developed for determination of nickel using furildioxime as complexing agent. Micellar solution of brij-35 is employed to solubilize the sparingly soluble complex of Ni-furildioxime in buffered aqueous system (pH-9.00). Under optimized conditions, absorbance is linear from 0.02 to 10 µg mL(-1) using 500 µL sample volume and from 10 to 30 µg mL(-1) using 50 µL sample volume of nickel at 480 nm, with R(2) = 0.9971 and 0.9916, respectively. The molar absorption coefficient and Sandell's sensitivity were 6.0 × 10(3) L mol(-1) cm(-1) and 0.01 ng cm(-2), respectively. The sample throughput of the method is 120 samples per hour with RSD of 0.01-0.2% for 0.02 to 10 µg mL(-1) nickel (n = 5), indicating that the method is highly precise and reproducible. Interference from cobalt is removed by Nitroso R-salt-modified XAD-16. The developed method is validated by analysing certified reference materials and is applied to assess nickel content of commercially available cigarettes.


Assuntos
Micelas , Níquel/análise , Oximas/química , Espectrofotometria/métodos , Cobalto/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...