Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Angiogenesis ; 27(1): 37-49, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37493987

RESUMO

Modern drug development increasingly requires comprehensive models that can be utilized in the earliest stages of compound and target discovery. Here we report a phenotypic screening exercise in a high-throughput Organ-on-a-Chip setup. We assessed the inhibitory effect of 1537 protein kinase inhibitors in an angiogenesis assay. Over 4000 micro-vessels were grown under perfusion flow in microfluidic chips, exposed to a cocktail of pro-angiogenic factors and subsequently exposed to the respective kinase inhibitors. Efficacy of compounds was evaluated by reduced angiogenic sprouting, whereas reduced integrity of the main micro-vessel was taken as a measure for toxicity. The screen yielded 53 hits with high anti-angiogenicity and low toxicity, of which 44 were previously unassociated with angiogenic pathways. This study demonstrates that Organ-on-a-Chip models can be screened in high numbers to identify novel compounds and targets. This will ultimately reduce bias in early-stage drug development and increases probability to identify first in class compounds and targets for today's intractable diseases.


Assuntos
Angiogênese , Antineoplásicos , Humanos , Sistemas Microfisiológicos , Antineoplásicos/uso terapêutico , Neovascularização Patológica/tratamento farmacológico , Inibidores de Proteínas Quinases/farmacologia
2.
Acta Biomater ; 164: 363-376, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37116636

RESUMO

Pathologies associated with uteroplacental hypoxia, such as preeclampsia are among the leading causes of maternal and perinatal morbidity in the world. Its fundamental mechanisms are yet poorly understood due to a lack of good experimental models. Here we report an in vitro model of the placental barrier, based on co-culture of trophoblasts and endothelial cells against a collagen extracellular matrix in a microfluidic platform. The model yields a functional syncytium with barrier properties, polarization, secretion of relevant extracellular membrane components, thinning of the materno-fetal space, hormone secretion, and transporter function. The model is exposed to low oxygen conditions and perfusion flow is modulated to induce a pathological environment. This results in reduced barrier function, hormone secretion, and microvilli as well as an increased nuclei count, characteristics of preeclamptic placentas. The model is implemented in a titer plate-based microfluidic platform fully amenable to high-throughput screening. We thus believe this model could aid mechanistic understanding of preeclampsia and other placental pathologies associated with hypoxia/ischemia, as well as support future development of effective therapies through target and compound screening campaigns. STATEMENT OF SIGNIFICANCE: The human placenta is a unique organ sustaining fetal growth but is also the source of severe pathologies, such as preeclampsia. Though leading cause of perinatal mortality in the world, preeclampsia remains untreatable due to a lack of relevant in vitro placenta models. To better understand the pathology, we have developed 3D placental barrier models in a microfluidic device. The platform allows parallel culture of 40 perfused physiological miniaturized placental barriers, comprising a differentiated syncytium and endothelium that have been validated for transporter functions. Exposure to a hypoxic and ischemic environment enabled the mimicking of preeclamptic characteristics in high-throughput, which we believe could lead to a better understanding of the pathology as well as support future effective therapies development.


Assuntos
Placenta , Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Células Endoteliais , Hipóxia , Isquemia , Dispositivos Lab-On-A-Chip , Hormônios
3.
STAR Protoc ; 4(1): 102051, 2023 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-36861838

RESUMO

Traditionally, to quantify permeability of a biological barrier, the initial slope is used, based on the assumption of sink condition (concentration of the donor is constant, and the receiver increases less than 10%). With on-a-chip barrier models, this assumption fails in cell-free or leaky conditions, which requires the use of the exact solution. To encounter a time delay from performing the assay and acquiring the data, we present a protocol with the exact equation modified to incorporate a time offset.


Assuntos
Bioensaio , Dispositivos Lab-On-A-Chip , Permeabilidade
4.
Redox Biol ; 57: 102488, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36201911

RESUMO

Reactive oxygen species (ROS) have different properties and biological functions. They contribute to cell signaling and, in excessive amounts, to oxidative stress (OS). Although ROS is pivotal in a wide number of physiological systems and pathophysiological processes, direct quantification in vivo is quite challenging and mainly limited to in vitro studies. Even though advanced in vitro cell culture techniques, like on-a-chip culture, have overcome the lack of crucial in vivo-like physiological aspects in 2D culture, the majority of in vitro ROS quantification studies are generally performed in 2D. Here we report the development, application, and validation of a multiplexed assay to quantify ROS and cell viability in organ-on-a-chip models. The assay utilizes three dyes to stain live cells for ROS, dead cells, and DNA. Confocal images were analyzed to quantify ROS probes and determine the number of nuclei and dead cells. We found that, in contrast to what has been reported with 2D cell culture, on-a-chip models are more prone to scavenge ROS rather than accumulate them. The assay is sensitive enough to distinguish between different phenotypes of endothelial cells (ECs) based on the level of OS to detect higher level in tumor than normal cells. Our results indicate that the use of physiologically relevant models and this assay could help unravelling the mechanisms behind OS and ROS accumulation. A further step could be taken in data analysis by implementing AI in the pipeline to also analyze images for morphological changes to have an even broader view of OS mechanism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...