Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Biomed Opt Express ; 15(4): 2114-2132, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633060

RESUMO

The clinical management of coronary artery disease and the prevention of acute coronary syndromes require knowledge of the underlying atherosclerotic plaque pathobiology. Hybrid imaging modalities capable of comprehensive assessment of biochemical and morphological plaques features can address this need. Here we report the first implementation of an intravascular catheter system combining fluorescence lifetime imaging (FLIm) with polarization-sensitive optical coherence tomography (PSOCT). This system provides multi-scale assessment of plaque structure and composition via high spatial resolution morphology from OCT, polarimetry-derived tissue microstructure, and biochemical composition from FLIm, without requiring any molecular contrast agent. This result was achieved with a low profile (2.7 Fr) double-clad fiber (DCF) catheter and high speed (100 fps B-scan rate, 40 mm/s pullback speed) console. Use of a DCF and broadband rotary junction required extensive optimization to mitigate the reduction in OCT performance originating from additional reflections and multipath artifacts. This challenge was addressed by the development of a broad-band (UV-visible-IR), high return loss (47 dB) rotary junction. We demonstrate in phantoms, ex vivo swine coronary specimens and in vivo swine heart (percutaneous coronary access) that the FLIm-PSOCT catheter system can simultaneously acquire co-registered FLIm data over four distinct spectral bands (380/20 nm, 400/20 nm, 452/45 nm, 540/45 nm) and PSOCT backscattered intensity, birefringence, and depolarization. The unique ability to collect complementary information from tissue (e.g., morphology, extracellular matrix composition, inflammation) with a device suitable for percutaneous coronary intervention offers new opportunities for cardiovascular research and clinical diagnosis.

3.
Catheter Cardiovasc Interv ; 99(4): 1188-1196, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35019207

RESUMO

OBJECTIVES: We describe the causes, timing and predictors of readmissions and analyze its impact on clinical outcomes in intermediate-to-high-risk patients with severe symptomatic aortic stenosis (AS) who underwent transcatheter aortic valve replacement (TAVR). BACKGROUND: Intermediate-high risk TAVR patients with severe AS have an increased risk for hospital readmissions due to the high burden of comorbidities. METHODS: Patients who underwent TAVR from 2012 to 2018 at a single tertiary cardiac center were included and followed for 1 year. Readmissions were categorized as noncardiovascular (non-CV) and CV. RESULTS: A total of 611 patients (410 with no readmissions, 201 with ≥1 readmissions) were included. There was a total of 317 readmissions (mean: 1.58 ± 1.09 per readmitted patient) with 65 patients having ≥2 readmissions. 64.0% were non-CV and 36.0% were CV. The top three CV causes were pacemaker/implantable cardioverter-defibrillator placement, bleeding, and stroke. About 23% occurred at 1 m, the majority were CV; 45% occurred between 7 and 12 m, the majority were non-CV. Those with ≥1 readmissions had a higher burden of comorbidities including peripheral arterial disease, diabetes, immunosuppression, prior percutaneous coronary interventions, and dialysis. Readmissions were associated with higher 1-year mortality (adjusted hazard ratio: 2.53, 95% confidence interval: 1.40-4.59; p = 0.002). High-risk patients had higher non-CV readmissions (0.37 ± 0.79 vs. 0.25 ± 0.62; p = 0.044) compared to intermediate-risk patients but similar CV readmissions (p = 0.645). CONCLUSIONS: Understanding readmissions post-TAVR will promote the early identification of at-risk groups and the implementation of preventative measures to improve outcomes and reduce the burden and costs of readmissions.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Readmissão do Paciente , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
JACC Cardiovasc Imaging ; 14(9): 1832-1842, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33221238

RESUMO

OBJECTIVES: This study aimed to systematically investigate whether plaque autofluorescence properties assessed with intravascular fluorescence lifetime imaging (FLIm) can provide qualitative and quantitative information about intimal composition and improve the characterization of atherosclerosis lesions. BACKGROUND: Despite advances in cardiovascular diagnostics, the analytic tools and imaging technologies currently available have limited capabilities for evaluating in situ biochemical changes associated with luminal surface features. Earlier studies of small number of samples have shown differences among the autofluorescence lifetime signature of well-defined lesions, but a systematic pixel-level evaluation of fluorescence signatures associated with various histological features is lacking and needed to better understand the origins of fluorescence contrast. METHODS: Human coronary artery segments (n = 32) were analyzed with a bimodal catheter system combining multispectral FLIm with intravascular ultrasonography compatible with in vivo coronary imaging. Various histological components present along the luminal surface (200-µm depth) were systematically tabulated (12 sectors) from each serial histological section (n = 204). Morphological information provided by ultrasonography allowed for the accurate registration of imaging data with histology data. The relationships between histological findings and FLIm parameters obtained from 3 spectral channels at each measurement location (n = 33,980) were characterized. RESULTS: Our findings indicate that fluorescence lifetime from different spectral bands can be used to quantitatively predict the superficial presence of macrophage foam cells (mFCs) (area under the receiver-operator characteristic curve: 0.94) and extracellular lipid content in advanced lesions (lifetime increase in 540-nm band), detect superficial calcium (lifetime decrease in 450-nm band area under the receiver-operator characteristic curve: 0.90), and possibly detect lesions consistent with active plaque formation such as pathological intimal thickening and healed thrombus regions (lifetime increase in 390-nm band). CONCLUSIONS: Our findings indicate that autofluorescence lifetime provides valuable information for characterizing atherosclerotic lesions in coronary arteries. Specifically, FLIm can be used to identify key phenomena linked with plaque progression (e.g., peroxidized-lipid-rich mFC accumulation and recent plaque formation).


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Biomarcadores , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagem Óptica , Valor Preditivo dos Testes , Ultrassonografia de Intervenção
8.
Sci Rep ; 7(1): 8960, 2017 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-28827758

RESUMO

Existing clinical intravascular imaging modalities are not capable of accurate detection of critical plaque pathophysiology in the coronary arteries. This study reports the first intravascular catheter combining intravascular ultrasound (IVUS) with multispectral fluorescence lifetime imaging (FLIm) that enables label-free simultaneous assessment of morphological and biochemical features of coronary vessels in vivo. A 3.7 Fr catheter with a fiber-optic channel was constructed based on a 40 MHz clinical IVUS catheter. The ability to safely acquire co-registered FLIm-IVUS data in vivo using Dextran40 solution flushing was demonstrated in swine coronary arteries. FLIm parameters from the arterial wall were consistent with the emission of fluorophores present in healthy arterial wall (collagen, elastin). Additionally, structural and biochemical features from atherosclerotic lesions were acquired in ex vivo human coronary samples and corroborated with histological findings. Current results show that FLIm parameters linked to the amount of structural proteins (e.g. collagen, elastin) and lipids (e.g. foam cells, extracellular lipids) in the first 200 µm of the intima provide important biochemical information that can supplement IVUS data for a comprehensive assessment of plaques pathophysiology. The unique FLIm-IVUS system evaluated here has the potential to provide a comprehensive insight into atherosclerotic lesion formation, diagnostics and response to therapy.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem Óptica/métodos , Ultrassonografia/métodos , Animais , Histocitoquímica , Humanos , Suínos
9.
Am J Crit Care ; 26(2): 140-148, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28249867

RESUMO

BACKGROUND: Diabetes is a common comorbid condition in patients with heart failure and is strongly associated with poor outcomes. Patients with heart failure who have diabetes are more likely to be obese than are those without diabetes. Obesity is positively associated with survival in patients with heart failure, but how comorbid diabetes influences the relationship between obesity and favorable prognosis is unclear. OBJECTIVE: To explore whether the relationship between body mass index and survival differs between patients with heart failure who do or do not have diabetes. METHODS: The sample consisted of 560 ambulatory patients with heart failure (mean age, 66 years; mean body mass index, 32; diabetes, 41%). The association between body mass index and all-cause mortality was examined by using multivariate Cox proportional hazards regression after adjustments for covariates. RESULTS: In patients without diabetes, higher body mass index was associated with a lower risk for all-cause mortality after adjustments for covariates (hazard ratio, 0.952; 95% CI, 0.909-0.998). In patients with diabetes, body mass index was not predictive of all-cause death after adjustments for covariates. CONCLUSION: Obesity was a survival benefit in heart failure patients without comorbid diabetes but not in those with comorbid diabetes. The mechanisms underlying the difference in the relationship between obesity and survival due to the presence of diabetes in patients with heart failure need to be elucidated.


Assuntos
Índice de Massa Corporal , Comorbidade , Complicações do Diabetes/mortalidade , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Obesidade/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Complicações do Diabetes/epidemiologia , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Modelos de Riscos Proporcionais , Medição de Risco , Estados Unidos/epidemiologia
12.
J Med Internet Res ; 18(3): e53, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26932229

RESUMO

As telehealth plays an even greater role in global health care delivery, it will be increasingly important to develop a strong evidence base of successful, innovative telehealth solutions that can lead to scalable and sustainable telehealth programs. This paper has two aims: (1) to describe the challenges of promoting telehealth implementation to advance adoption and (2) to present a global research agenda for personalized telehealth within chronic disease management. Using evidence from the United States and the European Union, this paper provides a global overview of the current state of telehealth services and benefits, presents fundamental principles that must be addressed to advance the status quo, and provides a framework for current and future research initiatives within telehealth for personalized care, treatment, and prevention. A broad, multinational research agenda can provide a uniform framework for identifying and rapidly replicating best practices, while concurrently fostering global collaboration in the development and rigorous testing of new and emerging telehealth technologies. In this paper, the members of the Transatlantic Telehealth Research Network offer a 12-point research agenda for future telehealth applications within chronic disease management.


Assuntos
Pesquisa Biomédica , Medicina de Precisão/tendências , Telemedicina/organização & administração , Doença Crônica/terapia , Gerenciamento Clínico , Previsões , Saúde Global , Humanos , Telemedicina/tendências
13.
Catheter Cardiovasc Interv ; 88(1): 38-48, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26916633

RESUMO

BACKGROUND: The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. METHODS: Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. RESULTS: Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. CONCLUSIONS: Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc.


Assuntos
Trombose Coronária/etiologia , Metais , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Stents , Trombose Coronária/diagnóstico , Trombose Coronária/mortalidade , Trombose Coronária/terapia , Stents Farmacológicos , Humanos , Metanálise em Rede , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Retratamento , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Transl Res ; 8(4): 253-63, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25931307

RESUMO

This study evaluates the ability of label-free fluorescence lifetime imaging (FLIm) to complement intravascular ultrasound (IVUS) for concurrent visualization of human coronary vessel composition, structure, and pathology. Co-registered FLIm and IVUS data from 16 coronary segments were correlated to eight distinct pathological features including thin-cap fibroatheroma (TCFA). The sensitivity, specificity, and positive predictive value for combined FLIm-IVUS (89, 99, 89 %) were better than FLIm (70, 98, 88 %) and IVUS (45, 94, 62 %) alone in distinguishing between pathologies. FLIm can assess compositional changes in luminal surface through variations in fluorescence lifetime values (<3.5 ns for lipid-rich areas; >4 ns for collagen-rich areas) enabling detection of macrophages in fibrous caps (sensitivity, 86 %) and distinguishing between relatively stable thick-cap fibroatheromas and rupture-prone TCFA (sensitivity, 80 %) amongst other features. Current results demonstrate the potential of FLIm-IVUS as a new intravascular method for improved evaluation of plaques that may subsequently aid in guiding coronary intervention.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagem Multimodal/métodos , Imagem Óptica , Placa Aterosclerótica , Ultrassonografia de Intervenção , Colágeno/análise , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/patologia , Vasos Coronários/metabolismo , Vasos Coronários/patologia , Estudos de Viabilidade , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Lipídeos/análise , Macrófagos/química , Macrófagos/diagnóstico por imagem , Macrófagos/patologia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Ruptura Espontânea
17.
Circ Heart Fail ; 7(6): 882-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25146960

RESUMO

BACKGROUND: There is abundant research indicating poor physical, psychological, and social functioning of patients with chronic heart failure (HF), a reality that can lead to poor health-related quality of life (QoL). Little is known about the experience of rural patients with HF. METHODS AND RESULTS: This study was part of a randomized clinical trial titled Rural Education to Improve Outcomes in Heart Failure (REMOTE-HF) designed to test an education and counseling intervention to improve self-care in patients with HF. We evaluated 612 rural patients. Multiple validated questionnaires were administered to assess patient perceptions of health and health literacy. Baseline factors were collected and compared with baseline QoL measures only. Patients' health-related QoL was assessed using the Minnesota Living with Heart Failure scale. The data were analyzed using a general linear model to test the association of various patient characteristics with QoL in rural patients with HF. Patients were 65.8 (+12.9) years of age. The majority were men (58.7%), married (56.4%), and had completed a high-school education (80.9%). Factors associated with reduced QoL among this population include geographic location, younger age, male sex, higher New York Heart Association class, worse HF knowledge, poorer perceived control, and symptoms of depression or anxiety. The data provided no evidence of an association between left ventricular ejection fraction and QoL. CONCLUSIONS: This study of rural patients with HF confirms previously identified factors associated with perceptions of QoL. However, further study is warranted with an urban control group. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00415545.


Assuntos
Qualidade de Vida , População Rural , Idoso , Feminino , Comportamentos Relacionados com a Saúde , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
20.
Am Heart J ; 165(3): 310-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23453098

RESUMO

BACKGROUND: Limited data are available regarding the safety and feasibility of initiating transradial (TR) diagnostic coronary angiography (CA) and percutaneous coronary intervention (PCI) in cardiology fellowship programs. METHODS: From July 2010 to June 2011, University of California, Davis Medical Center, adopted the TR approach with supervised cardiology fellows as the primary operators. Procedural variables and clinical outcomes of TR and transfemoral (TF) procedures were compared. To minimize confounding variables, ST-elevation myocardial infarction, bypass graft interventions, chronic total occlusions, and procedures with concomitant right heart catheterizations were excluded. To reflect the learning curve of the TR approach, this experience was assessed in 2 sequential 6-month periods. RESULTS: A total of 402 diagnostic CAs and 255 PCIs were included. Transradial access was used in 141 (35%) of the CAs and in 72 (28%) of PCIs. Within the TR-CA and TF-CA (n = 261) groups, there was no difference between fluoroscopy (10.4 ± 6.0 vs 11.0 ± 8.9, P = .63) or procedure (31.8 ± 11.5 vs 33.2 ± 13.8, P = .55) time throughout the academic year with a significant trend toward lower contrast use (128 ± 52 vs 110 vs 50, P = .04) by the second half. In addition, during the second half of the academic year, the TR-CA showed significantly higher fluoroscopy (11.0 ± 8.9 vs 6.7 ± 6.8, P = .001) and procedure (33.2 ± 13.8 vs 27.2 ± 11.6, P = .0015) times when compared with TF-CA. Transfemoral PCI (n = 183) and TR-PCI showed no significant difference between all fluoroscopy and procedure time and contrast use when comparing the 2 halves of the academic year. When comparing TF with TR within each academic half year, there was no difference within the PCI group. Vascular complications were less with the TR approach. Overall procedural success rates were high, and there were low rates of crossover and periprocedural complications in both the TR and the TF groups. CONCLUSION: A TR approach is safe for CA and PCI when performed by supervised operators in training. Although the learning curve for trainees appears slower for TR-CA compared with TF-CA, cardiology fellowship training programs should be encouraged to adopt TR procedures as part of their curriculum.


Assuntos
Angiografia Coronária/métodos , Artéria Femoral/diagnóstico por imagem , Fluoroscopia/métodos , Intervenção Coronária Percutânea/métodos , Artéria Radial/diagnóstico por imagem , Idoso , Angiografia Coronária/efeitos adversos , Feminino , Fluoroscopia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...