Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Acta Odontol Latinoam ; 36(2): 112-119, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37776508

RESUMO

Advanced Polymerization System (APS) technology in a commercial composite resin enables reduction of the concentration of camphorquinone without altering composite physicochemical properties. AIM: The aim of this study was to evaluate the degree of conversion and mechanical properties of a commercial composite with an advanced polymerization system (APS) and compare it to other composites that do not use this system. MATERIALS AND METHOD: Five groups were analyzed. Group 1 (VT: Vittra APS - FGM); G2 (AU: Aura - SDI); G3 (ES: Quick Sigma Stelite - TOKOYAMA); G4 (FZ: Filtek Z350 XT - 3M ESPE); G5 (OP: Opallis -FGM). Degree of conversion (DC, n=3) was analyzed immediately and after 24h by analysis with FTIR spectroscopy. For Knoop hardness (KHN, n=3), 5 indentations were made at the top and bottom of specimens 2 mm thick. Flexural strength (FS, n=10) was determined by the three-point method in a universal testing machine. Polymerization stress (PS) was determined by light-curing the material (1.0 mm high) between polymethylmethacrylate rods in a universal testing machine. Light curing was performed with a Valo Cordless LED (1,000 mW/cm2 x 20 s: 20J). The results were analyzed using ANOVA and complemented by Tukey's test (α=0.05). RESULTS: The highest DC values (immediate and 24h after) were observed for VT and OP resins, followed by FZ, AU and ES. FZ (top and bottom) had the highest KHN values, similar to VT top. AU, ES, OP and VT had statistically different KHN between their top and bottom surfaces. The highest RF values were observed for FZ, followed by OP/VT, ES and AU. The highest TP values were observed for FZ, OP and VT. CONCLUSION: The Vittra APS resin with a new polymerization system presents satisfactory performance for the parameters evaluated.


A tecnologia Advanced Polymerization System (APS) presente em uma resina composta comercial permite reduzir a concentração de canforoquinona sem alterar as propriedades físico-químicas do compósito. Objetivo: o objetivo deste estudo foi avaliar o grau de conversão e as propriedades mecânicas de um compósito comercial com sistema avançado de polimerização (SAP) e comparálo com outros compósitos que não utilizam esse sistema. Materiais e Método: cinco grupos foram analisados. Grupo 1 (VT: Vittra APS - FGM); G2 (AU: Aura ­ SDI); G3 (ES: Quick Sigma Stelite ­ TOKOYAMA); G4 (FZ: Filtek Z350 XT ­ 3M ESPE); G5 (OP: Opallis -FGM). O grau de conversão (GC, n=3) foi analisado imediatamente e após 24h através da análise com espectroscopia FTIR; para dureza Knoop (DK, n=3), foram feitas 5 indentações no topo e na base de corpos de prova de 2 mm de espessura; para determinar a resistência à flexão (RF, n=10), o método de três pontos foi realizado em uma máquina universal de ensaios; a tensão de polimerização (TP) foi determinada pela fotopolimerização do material (1,0 mm de altura) entre hastes de polimetilmetacrilato em uma máquina de teste universal. A fotopolimerização foi realizada com um Valo Cordless LED (1.000 mW/cm2 x 20 s: 20J). Os resultados foram analisados por ANOVA e complementados pelo teste de Tukey (α=0,05). Resultados: os maiores valores de GC (imediato e 24h após) foram observados para as resinas VT e OP, seguidas de FZ, AU e ES. A resina FZ (superior e inferior) apresentou os maiores valores de DK, semelhante ao VT superior. As resinas AU, ES, OP e VT apresentaram DK estatisticamente diferente entre suas superfícies de topo e base. Os maiores valores de RF foram observados para FZ, seguido de OP/VT, ES e AU. Os maiores valores de TP foram observados para FZ, OP e VT. Conclusão: com base nos resultados, pode-se concluir que a resina Vittra APS com um novo sistema de polimerização apresenta desempenho satisfatório para os parâmetros avaliados.

2.
Acta odontol. latinoam ; 36(2): 112-119, Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513554

RESUMO

ABSTRACT Advanced Polymerization System (APS) technology in a commercial composite resin enables reduction of the concentration of camphorquinone without altering composite physicochemical properties. Aim: The aim of this study was to evaluate the degree of conversion and mechanical properties of a commercial composite with an advanced polymerization system (APS) and compare it to other composites that do not use this system. Materials and Method: Five groups were analyzed. Group 1 (VT: Vittra APS - FGM); G2 (AU: Aura - SDI); G3 (ES: Quick Sigma Stelite - TOKOYAMA); G4 (FZ: Filtek Z350 XT - 3M ESPE); G5 (OP: Opallis -FGM). Degree of conversion (DC, n=3) was analyzed immediately and after 24h by analysis with FTIR spectroscopy. For Knoop hardness (KHN, n=3), 5 indentations were made at the top and bottom of specimens 2 mm thick. Flexural strength (FS, n=10) was determined by the three-point method in a universal testing machine. Polymerization stress (PS) was determined by light-curing the material (1.0 mm high) between polymethylmethacrylate rods in a universal testing machine. Light curing was performed with a Valo Cordless LED (1,000 mW/cm2 x 20 s: 20J). The results were analyzed using ANOVA and complemented by Tukey's test (α=0.05). Results: The highest DC values (immediate and 24h after) were observed for VT and OP resins, followed by FZ, AU and ES. FZ (top and bottom) had the highest KHN values, similar to VT top. AU, ES, OP and VT had statistically different KHN between their top and bottom surfaces. The highest RF values were observed for FZ, followed by OP/VT, ES and AU. The highest TP values were observed for FZ, OP and VT. Conclusion: The Vittra APS resin with a new polymerization system presents satisfactory performance for the parameters evaluated.


RESUMO A tecnologia Advanced Polymerization System (APS) presente em uma resina composta comercial permite reduzir a concentração de canforoquinona sem alterar as propriedades físico-químicas do compósito. Objetivo: o objetivo deste estudo foi avaliar o grau de conversão e as propriedades mecânicas de um compósito comercial com sistema avançado de polimerização (SAP) e comparálo com outros compósitos que não utilizam esse sistema. Materiais e Método: cinco grupos foram analisados. Grupo 1 (VT: Vittra APS - FGM); G2 (AU: Aura - SDI); G3 (ES: Quick Sigma Stelite - TOKOYAMA); G4 (FZ: Filtek Z350 XT - 3M ESPE); G5 (OP: Opallis -FGM). O grau de conversão (GC, n=3) foi analisado imediatamente e após 24h através da análise com espectroscopia FTIR; para dureza Knoop (DK, n=3), foram feitas 5 indentações no topo e na base de corpos de prova de 2 mm de espessura; para determinar a resistência à flexão (RF, n=10), o método de três pontos foi realizado em uma máquina universal de ensaios; a tensão de polimerização (TP) foi determinada pela fotopolimerização do material (1,0 mm de altura) entre hastes de polimetilmetacrilato em uma máquina de teste universal. A fotopolimerização foi realizada com um Valo Cordless LED (1.000 mW/cm2 x 20 s: 20J). Os resultados foram analisados por ANOVA e complementados pelo teste de Tukey (α=0,05). Resultados: os maiores valores de GC (imediato e 24h após) foram observados para as resinas VT e OP, seguidas de FZ, AU e ES. A resina FZ (superior e inferior) apresentou os maiores valores de DK, semelhante ao VT superior. As resinas AU, ES, OP e VT apresentaram DK estatisticamente diferente entre suas superfícies de topo e base. Os maiores valores de RF foram observados para FZ, seguido de OP/VT, ES e AU. Os maiores valores de TP foram observados para FZ, OP e VT. Conclusão: com base nos resultados, pode-se concluir que a resina Vittra APS com um novo sistema de polimerização apresenta desempenho satisfatório para os parâmetros avaliados.

3.
Materials (Basel) ; 11(7)2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-29941832

RESUMO

This study is aimed at evaluating the effects of triclosan-encapsulated halloysite nanotubes (HNT/TCN) on the physicochemical and microbiological properties of an experimental dental composite. A resin composite doped with HNT/TCN (8% w/w), a control resin composite without nanotubes (HNT/TCN-0%) and a commercial nanofilled resin (CN) were assessed for degree of conversion (DC), flexural strength (FS), flexural modulus (FM), polymerization stress (PS), dynamic thermomechanical (DMA) and thermogravimetric analysis (TGA). The antibacterial properties (M) were also evaluated using a 5-day biofilm assay (CFU/mL). Data was submitted to one-way ANOVA and Tukey tests. There was no significant statistical difference in DC, FM and RU between the tested composites (p > 0.05). The FS and CN values attained with the HNT/TCN composite were higher (p < 0.05) than those obtained with the HNT/TCN-0%. The DMA analysis showed significant differences in the TAN δ (p = 0.006) and Tg (p = 0) between the groups. TGA curves showed significant differences between the groups in terms of degradation (p = 0.046) and weight loss (p = 0.317). The addition of HNT/TCN induced higher PS, although no significant antimicrobial effect was observed (p = 0.977) between the groups for CFUs and (p = 0.557) dry weight. The incorporation of HNT/TCN showed improvements in physicochemical and mechanical properties of resin composites. Such material may represent an alternative choice for therapeutic restorative treatments, although no significance was found in terms of antibacterial properties. However, it is possible that current antibacterial tests, as the one used in this laboratory study, may not be totally appropriate for the evaluation of resin composites, unless accompanied with aging protocols (e.g., thermocycling and load cycling) that allow the release of therapeutic agents incorporated in such materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...