Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(8): 081101, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30184651

RESUMO

The applications of ion beams are manifold. In most systems, improved extraction of the ion beam from the ion source can help to increase the ion beam current or to improve the ion beam emittance. Real understanding of the complete system is required to achieve improvement of ion beam intensity or ion beam quality. Mathematically, the situation is described by a boundary value problem for the fields and an initial value problem for ion beam tracking. Whereas the boundary value problem is similar for different ion sources, the initial value problem to be solved depends on very specific ion source conditions. The influence of different parameters like particle density and temperatures on the discharge itself is important. For the case of ion beam extraction from an electron cyclotron resonance ion source, the problems of a suitable model will be discussed in detail. It will be shown that specific diagnostics are required to measure specific beam parameters. Such diagnostics are to be included in the simulation as well. The overall goal remains to develop a model that can be used for further improvements of beam intensity and quality from specific ion sources.

2.
Rev Sci Instrum ; 87(2): 02A712, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931930

RESUMO

In order to increase the intensity of the highly charged ions produced by the Electron Cyclotron Resonance Ion Sources (ECRISs), techniques like the frequency tuning and the afterglow mode have been developed and in this paper the effect on the ion production is shown for the first time when combining both techniques. Recent experimental results proved that the tuning of the operating frequency of the ECRIS is a promising technique to achieve higher ion currents of higher charge states. On the other hand, it is well known that the afterglow mode of the ECRIS operation can provide more intense pulsed ion beams in comparison with the continuous wave (cw) operation. These two techniques can be combined by pulsing the variable frequency signal driving the traveling wave tube amplifier which provides the high microwave power to the ECRIS. In order to analyze the effect of these two combined techniques on the ion source performance, several experiments were carried out on the pulsed frequency tuned CAPRICE (Compacte source A Plusiers Résonances Ionisantes Cyclotron Electroniques)-type ECRIS. Different waveforms and pulse lengths have been investigated under different settings of the ion source. The results of the pulsed mode have been compared with those of cw operation.

3.
Rev Sci Instrum ; 87(2): 02A724, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931942

RESUMO

Simulation of ion beam extraction from an Electron Cyclotron Resonance Ion Source (ECRIS) is a fully 3 dimensional problem, even if the extraction geometry has cylindrical symmetry. Because of the strong magnetic flux density, not only the electrons are magnetized but also the Larmor radius of ions is much smaller than the geometrical dimension of the plasma chamber (Ø 64 × 179 mm). If we assume that the influence of collisions is small on the path of particles, we can do particle tracking through the plasma if the initial coordinates of particles are known. We generated starting coordinates of plasma ions by simulation of the plasma electrons, accelerated stochastically by the 14.5 GHz radio frequency power fed to the plasma. With that we were able to investigate the influence of different electron energies on the extracted beam. Using these assumptions, we can reproduce the experimental results obtained 10 years ago, where we monitored the beam profile with the help of viewing targets. Additionally, methods have been developed to investigate arbitrary 2D cuts of the 6D phase space. To this date, we are able to discuss full 4D information. Currently, we extend our analysis tool towards 5D and 6D, respectively.

4.
Rev Sci Instrum ; 83(2): 02A304, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380151

RESUMO

The properties of the electromagnetic waves heating the electrons of the ECR ion sources (ECRIS) plasma affect the features of the extracted ion beams such as the emittance, the shape, and the current, in particular for higher charge states. The electron heating methods such as the frequency tuning effect and the double frequency heating are widely used for enhancing the performances of ECRIS or even for the routine operation during the beam production. In order to better investigate these effects the CAPRICE ECRIS has been operated using these techniques. The ion beam properties for highly charged ions have been measured with beam diagnostic tools. The reason of the observed variations of this performance can be related to the different electromagnetic field patterns, which are changing inside the plasma chamber when the frequency is varying.

5.
Rev Sci Instrum ; 83(2): 02A312, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380159

RESUMO

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar(4+) beam intensity of up to 2 µA was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.


Assuntos
Ciclotrons , Elétrons , Campos Magnéticos , Modelos Teóricos , Fenômenos Ópticos , Gases em Plasma/química , Temperatura
6.
Rev Sci Instrum ; 83(2): 02A319, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380166

RESUMO

The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.

7.
Rev Sci Instrum ; 83(2): 02B720, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380325

RESUMO

Using improved beam diagnostic tools, the structure of an ion beam extracted from an electron cyclotron resonance ion source (ECRIS) becomes visible. Especially viewing targets to display the beam profile and pepper pot devices for emittance measurements turned out to be very useful. On the contrary, diagnostic tools integrating over one space coordinate like wire harps for profile measurements or slit-slit devices, respectively slit-grid devices to measure the emittance might be applicable for beam transport investigations in a quadrupole channel, but are not very meaningful for investigations regarding the given ECRIS symmetry. Here we try to reproduce the experimentally found structure on the ion beam by simulation. For the simulation, a certain model has to be used to reproduce the experimental results. The model is also described in this paper.

8.
Rev Sci Instrum ; 82(12): 123302, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22225210

RESUMO

The electromagnetic field within the plasma chamber of an electron cyclotron resonance ion source (ECRIS) and the properties of the plasma waves affect the plasma properties and ion beam production. We have experimentally investigated the "frequency tuning effect" and "double frequency heating" on the CAPRICE ECRIS device. A traveling wave tube amplifier, two microwave sweep generators, and a dedicated experimental set-up were used to carry out experiments in the 12.5-16.5 GHz frequency range. During the frequency sweeps the evolution of the intensity and shape of the extracted argon beam were measured together with the microwave reflection coefficient. A range of different ion source parameter settings was used. Here we describe these experiments and the resultant improved understanding of these operational modes of the ECR ion source.

9.
Rev Sci Instrum ; 81(2): 02B707, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192447

RESUMO

The first emittance measurements with a new test injector facility (HOSTI) at GSI, designed for optimization of high current beam injection scheme, are discussed. The emittance of the ion beam (88 kV, Ar(1+) ions) was investigated as a function of various parameters related to the ion source, extraction, and postacceleration systems and the optimum parameters for future low energy beam transport line are concluded. The preliminary results of the emittance measurements with superconducting solenoid are presented. The influence of the focusing strength as well as the longitudinal field shape of the solenoid on the beam emittance is described.

10.
Rev Sci Instrum ; 81(2): 02B720, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192460

RESUMO

The emittance of an extracted ion beam can be estimated to first order by a series of three linear independent profile measurements. This estimation is restricted to the evaluation of an upper limit of the emittance value for a homogeneous, nonfilamented beam. The beam is assumed to be round, respectively elliptical, without any structure of the intensity distribution, no space charge has been assumed for the drifting beam, and the optics is assumed to be linear. Instead of using three different drift sections, a linear focusing element with three different focusing strengths can be used. Plotting the beam radius as function of focusing strength, three independent solutions can be used to calculate the Twiss parameters alpha, beta, and gamma and furthermore the emittance epsilon. Here we describe the measurements which have been performed with the SECRAL ion source at Institute of Modern Physics Lanzhou.

11.
Rev Sci Instrum ; 81(2): 02B725, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192465

RESUMO

The finite difference method trajectory code KOBRA3-INP has been developed now for 25 years to perform the simulation of ion beam extraction in three dimensions. Meanwhile, the code has been validated for different applications: high current ion beam extraction from plasma sources for ion implantation technology, neutral gas heating in fusion devices, or ion thrusters for space propulsion. One major issue of the development of this code was to improve the flexibility of the applied model for the simulation of different types of particle sources. Fixed emitter sources might be simulated with that code as well as laser ion sources, Penning ion sources, electron cyclotron resonance ion sources (ECRISs), or H(-) sources, which require the simulation of negative ions, negative electrons, and positive charges simultaneously. The model which has been developed for ECRIS has now been used to explore the conditions for the ion beam extraction from a still nonexisting ion source, a so called ARC-ECRIS [P. Suominen and F. Wenander, Rev. Sci. Instrum. 79, 02A305 (2008)]. It has to be shown whether the plasma generator has similar properties like regular ECRIS. However, the emittance of the extracted beam seems to be much better compared to an ECRIS equipped with a hexapole.

12.
Rev Sci Instrum ; 79(2 Pt 2): 02A303, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315093

RESUMO

The increased requirements towards the use of higher ion beam intensities motivated us to initiate the project to improve the overall transmission of the K130 cyclotron facility. With the facility the transport efficiency decreases rapidly as a function of total beam intensity extracted from the JYFL ECR ion sources. According to statistics, the total transmission efficiency is of the order of 10% for low beam intensities (I(total)< or =0.7 mA) and only about 2% for high beam intensities (I(total)>1.5 mA). Requirements towards the use of new metal ion beams for the nuclear physics experiments have also increased. The miniature oven used for the production of metal ion beams at the JYFL is not able to reach the temperature needed for the requested metal ion beams. In order to fulfill these requirements intensive development work has been performed. An inductively and a resistively heated oven has successfully been developed and both are capable of reaching temperatures of about 2000 degrees C. In addition, sputtering technique has been tested. GEANT4 simulations have been started in order to better understand the processes involved with the bremsstrahlung, which gives an extra heat load to cryostat in the case of superconducting ECR ion source. Parallel with this work, a new advanced ECR heating simulation program has been developed. In this article we present the latest results of the above-mentioned projects.

13.
Rev Sci Instrum ; 79(2 Pt 2): 02A317, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315107

RESUMO

Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be approximately 70 pi mm mrad, and the total extracted beam current obtained at 14 kV extraction voltage was approximately 25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data.

14.
Rev Sci Instrum ; 79(2 Pt 2): 02A331, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315121

RESUMO

Radiotherapy with heavy ions is an upcoming cancer treatment method with to date unparalleled precision. It associates higher control rates particularly for radiation resistant tumor species with reduced adverse effects compared to conventional photon therapy. The accelerator beam lines and structures of the Heidelberg Ion Beam Therapy Center (HIT) have been designed under the leadership of GSI, Darmstadt with contributions of the IAP Frankfurt. Currently, the accelerator is under commissioning, while the injector linac has been completed. When the patient treatment begins in 2008, HIT will be the first medical heavy ion accelerator in Europe. This presentation will provide an overview about the project, with special attention given to the 14.5 GHz electron cyclotron resonance (ECR) ion sources in operation with carbon, hydrogen, helium, and oxygen, and the experience of one year of continuous operation. It also displays examples for beam emittances, measured in the low energy beam transport. In addition to the outlook of further developments at the ECR ion sources for a continuously stable operation, this paper focuses on some of the technical processings of the past year.


Assuntos
Ciclotrons/instrumentação , Radioterapia com Íons Pesados , Radioterapia de Alta Energia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
15.
Rev Sci Instrum ; 79(2 Pt 2): 02B704, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315195

RESUMO

In the framework of the future project FAIR several upgrade programs and construction of new facilities are in progress such as the U(4+) upgrade for the existing high current injector and the new 70 MeV proton injector. For both injectors solenoids in the low energy beam transport section are foreseen to inject the beam into the following rf accelerator. The paper presents beam quality measurements of high current ion beams behind a solenoid using a slit-grid emittance measurement device, viewing targets, and a pepper pot measurement device at the high current test bench at GSI.

16.
Rev Sci Instrum ; 79(2 Pt 2): 02C703, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315256

RESUMO

Vacuum arc ion sources, Penning ion sources, and filament driven multicusp ion sources are used for the production of high current ion beams of a variety of metallic and gaseous ions at the GSI accelerator facility. For accelerator operation, the ion sources have to provide a stable beam over a long period of time with an energy of 2.2 keV/u and a maximum mass over charge ratio of 65. The status of beam time operation at the high current injector is presented here giving an outline on important ion source data, such as ion beam current, ion beam spectrum, transversal emittance, life time, duty factor, and transmission along the low energy beam transport section.

17.
Rev Sci Instrum ; 79(2 Pt 1): 023305, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315291

RESUMO

A set of measurements with the CAPRICE ion source at the GSI test bench has been carried out to investigate its behavior in terms of intensity and shape of the extracted beam when the microwaves generating the plasma sweep in a narrow range of frequency (+/-40 MHz) around the klystron center frequency (14.5 GHz). Remarkable variations have been observed depending on the source and the beamline operating parameters, confirming that a frequency dependent electromagnetic distribution is preserved even in the presence of plasma inside the source. Moreover, these observations confirm that the frequency tuning is a powerful method to optimize the electron cyclotron resonance ion source performances. A description of the experimental setup and of the obtained results is given in the following.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...