1.
Med Eng Phys ; 130: 104216, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39160022

RESUMO

PURPOSE: Rehabilitation technology can be used to provide intensive training in the early phases after stroke. The current study aims to assess the feasibility of combining robotics and functional electrical stimulation (FES), with an assist-as-needed approach to support actively-initiated leg movements in (sub-)acute stroke patients. METHOD: Nine subacute stroke patients performed repetitions of ankle dorsiflexion and/or knee extension movements, with and without assistance. The assist-as-needed algorithm determined the amount and type of support needed per repetition. The number of repetitions and range of motion with and without assistance were compared with descriptive statistics. Fatigue scores were obtained using the visual analogue scale (score 0-10). RESULTS: Support was required in 44 % of the repetitions for ankle dorsiflexion and in 5 % of the repetitions of knee extension, The median fatigue score was 2.0 (IQR: 0.2) and 4.0 (IQR: 1.5) for knee and ankle, respectively, indicating mild to moderate perceived fatigue. CONCLUSION: This study demonstrated the feasibility of assist-as-needed assistance through combined robotic and FES support of leg movements in stroke patients. It proved particularly useful for ankle dorsiflexion. Future research should focus on implementing this approach in a clinical setting, to assess clinical applicability and potential effects on leg function.


Assuntos
Estudos de Viabilidade , Perna (Membro) , Movimento , Robótica , Reabilitação do Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Perna (Membro)/fisiopatologia , Reabilitação do Acidente Vascular Cerebral/instrumentação , Reabilitação do Acidente Vascular Cerebral/métodos , Idoso , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/terapia , Estimulação Elétrica , Adulto
2.
Comput Biol Med ; 179: 108839, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39002320

RESUMO

BACKGROUND: Although early rehabilitation is important following a stroke, severely affected patients have limited options for intensive rehabilitation as they are often bedridden. To create a system for early rehabilitation of lower extremities in these patients, we combined the robotic manipulator ROBERT® with electromyography (EMG)-triggered functional electrical stimulation (FES) and developed a novel user-driven Assist-As-Needed (AAN) control. The method is based on a state machine able to detect user movement capability, assessed by the presence of an EMG-trigger and the movement velocity, and provide different levels of assistance as required by the patient (no support, FES only, and simultaneous FES and mechanical assistance). METHODS: To technically validate the system, we tested 10 able-bodied participants who were instructed to perform specific behaviors to test the system states while conducting knee extension and ankle dorsal flexion exercises. The system was also tested on two stroke patients to establish its clinical feasibility. RESULTS: The technical validation showed that the state machine correctly detected the participants' behavior and activated the target AAN state in more than 96% of the exercise repetitions. The clinical feasibility test showed that the system successfully recognized the patients' movement capacity and activated assistive states according to their needs providing the minimal level of support required to exercise successfully. CONCLUSIONS: The system was technically validated and preliminarily proved clinically feasible. The present study shows that the novel system can be used to deliver exercises with a high number of repetitions while engaging the participants' residual capabilities through the AAN strategy.


Assuntos
Extremidade Inferior , Robótica , Reabilitação do Acidente Vascular Cerebral , Humanos , Reabilitação do Acidente Vascular Cerebral/instrumentação , Reabilitação do Acidente Vascular Cerebral/métodos , Robótica/instrumentação , Masculino , Feminino , Extremidade Inferior/fisiopatologia , Adulto , Pessoa de Meia-Idade , Eletromiografia , Acidente Vascular Cerebral/fisiopatologia , Estudos de Viabilidade , Idoso
3.
Artif Organs ; 48(4): 421-425, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38339848

RESUMO

The annual conference of the International Functional Electrical Stimulation Society (IFESS) was held in conjunction with the 7th RehabWeek Congress, from September 24 to 28, 2023 at the Resorts World Convention Centre on Sentosa Island, in Singapore. The Congress was a joint meeting of the International Consortium on Rehabilitation Technology (ICRT) together with 10 other societies in the field of assistive technology and rehabilitation engineering. The conference features comprehensive blend of technical and clinical context of FES, a sustained value the society has offered over many years. The cross- and inter- disciplinary approach of medicine, engineering, and science practiced in the FES community had enabled vibrant interaction, creation, and development of impactful and novel contributions to the field of FES, translating FES directly into highly relevant and sustainable solutions for the users.


Assuntos
Terapia por Estimulação Elétrica , Sociedades Médicas , Estimulação Elétrica
4.
J Neuroeng Rehabil ; 21(1): 10, 2024 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-38245782

RESUMO

BACKGROUND: Restorative Brain-Computer Interfaces (BCI) that combine motor imagery with visual feedback and functional electrical stimulation (FES) may offer much-needed treatment alternatives for patients with severely impaired upper limb (UL) function after a stroke. OBJECTIVES: This study aimed to examine if BCI-based training, combining motor imagery with FES targeting finger/wrist extensors, is more effective in improving severely impaired UL motor function than conventional therapy in the subacute phase after stroke, and if patients with preserved cortical-spinal tract (CST) integrity benefit more from BCI training. METHODS: Forty patients with severe UL paresis (< 13 on Action Research Arm Test (ARAT) were randomized to either a 12-session BCI training as part of their rehabilitation or conventional UL rehabilitation. BCI sessions were conducted 3-4 times weekly for 3-4 weeks. At baseline, Transcranial Magnetic Stimulation (TMS) was performed to examine CST integrity. The main endpoint was the ARAT at 3 months post-stroke. A binominal logistic regression was conducted to examine the effect of treatment group and CST integrity on achieving meaningful improvement. In the BCI group, electroencephalographic (EEG) data were analyzed to investigate changes in event-related desynchronization (ERD) during the course of therapy. RESULTS: Data from 35 patients (15 in the BCI group and 20 in the control group) were analyzed at 3-month follow-up. Few patients (10/35) improved above the minimally clinically important difference of 6 points on ARAT, 5/15 in the BCI group, 5/20 in control. An independent-samples Mann-Whitney U test revealed no differences between the two groups, p = 0.382. In the logistic regression only CST integrity was a significant predictor for improving UL motor function, p = 0.007. The EEG analysis showed significant changes in ERD of the affected hemisphere and its lateralization only during unaffected UL motor imagery at the end of the therapy. CONCLUSION: This is the first RCT examining BCI training in the subacute phase where only patients with severe UL paresis were included. Though more patients in the BCI group improved relative to the group size, the difference between the groups was not significant. In the present study, preserved CTS integrity was much more vital for UL improvement than which type of intervention the patients received. Larger studies including only patients with some preserved CST integrity should be attempted.


Assuntos
Interfaces Cérebro-Computador , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Projetos Piloto , Acidente Vascular Cerebral/complicações , Extremidade Superior , Paresia/reabilitação
5.
Artif Organs ; 48(6): 626-635, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38149317

RESUMO

BACKGROUND: Electrotactile systems are compact interfaces that can be used to convey information through the skin by producing a range of haptic sensations. In many applications, however, the user needs to perceive and interpret haptic stimulation while being engaged in parallel activities. Developing methods that ensure reliable recognition of electrotactile messages despite additional cognitive load is, therefore, an important step for the practical application of electrotactile displays. METHODS: This study investigated if a simple strategy of repeating electrotactile messages can improve message identification during multitasking. Ten participants identified 36 spatiotemporal electrotactile messages delivered through a 3 × 2 pad-matrix electrode placed on the torso while performing a concomitant cognitive task in three conditions: the messages were presented once (No-REP), and each message was repeated three (REP3) and five (REP5) times. The main outcome measure was the success rate (SR) of message identification. RESULTS: During multitasking, in the No-REP condition, the SR (median (IQR)) dropped to 56.25% (22.62%), demonstrating that the cognitive task decreased performance. However, the SR significantly improved with message repetitions, reaching 72.92% (21.87%) and 81.25% (18.66%) in REP3 and REP5 conditions respectively, without a statistically significant difference between REP3 and REP5. CONCLUSIONS: Multitasking affected the efficacy of haptic communication, but message repetition was shown to be an effective strategy for improving performance. Additionally, only three repetitions were enough, as an additional increase in the duration of message transmission (5 repetitions) did not lead to further improvement. This study is an important step toward delivering electrotactile communication that can cope with the demands of real-world applications.


Assuntos
Cognição , Eletrodos , Tato , Humanos , Masculino , Cognição/fisiologia , Feminino , Tato/fisiologia , Adulto Jovem , Adulto , Desenho de Equipamento
6.
Sensors (Basel) ; 23(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37112305

RESUMO

Auditory feedback has earlier been explored as a tool to enhance patient awareness of gait kinematics during rehabilitation. In this study, we devised and tested a novel set of concurrent feedback paradigms on swing phase kinematics in hemiparetic gait training. We adopted a user-centered design approach, where kinematic data recorded from 15 hemiparetic patients was used to design three feedback algorithms (wading sounds, abstract, musical) based on filtered gyroscopic data from four inexpensive wireless inertial units. The algorithms were tested (hands-on) by a focus group of five physiotherapists. They recommended that the abstract and musical algorithms be discarded due to sound quality and informational ambiguity. After modifying the wading algorithm (as per their feedback), we conducted a feasibility test involving nine hemiparetic patients and seven physiotherapists, where variants of the algorithm were applied to a conventional overground training session. Most patients found the feedback meaningful, enjoyable to use, natural-sounding, and tolerable for the typical training duration. Three patients exhibited immediate improvements in gait quality when the feedback was applied. However, minor gait asymmetries were found to be difficult to perceive in the feedback, and there was variability in receptiveness and motor change among the patients. We believe that our findings can advance current research in inertial sensor-based auditory feedback for motor learning enhancement during neurorehabilitation.


Assuntos
Transtornos Neurológicos da Marcha , Reabilitação Neurológica , Paresia , Humanos , Fenômenos Biomecânicos , Retroalimentação , Marcha , Transtornos Neurológicos da Marcha/reabilitação , Extremidade Inferior , Paresia/reabilitação , Reabilitação Neurológica/métodos
8.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36850871

RESUMO

This study proposes a bioinspired exotendon routing configuration for a tendon-based mechanism to provide finger flexion and extension that utilizes a single motor to reduce the complexity of the system. The configuration was primarily inspired by the extrinsic muscle-tendon units of the human musculoskeletal system. The function of the intrinsic muscle-tendon units was partially compensated by adding a minor modification to the configuration of the extrinsic units. The finger kinematics produced by this solution during flexion and extension were experimentally evaluated on an artificial finger and compared to that obtained using the traditional mechanism, where one exotendon was inserted at the distal phalanx. The experiments were conducted on nine healthy subjects who wore a soft exoskeleton glove equipped with the novel tendon mechanism. Contrary to the traditional approach, the proposed mechanism successfully prevented the hyperextension of the distal interphalangeal (DIP) and the metacarpophalangeal (MCP) joints. During flexion, the DIP joint angles produced by the novel mechanism were smaller than the angles generated by the traditional approach for the same proximal interphalangeal (PIP) joint angles. This provided a flexion trajectory closer to the voluntary flexion motion and avoided straining the interphalangeal coupling between the DIP and PIP joints. Finally, the proposed solution generated similar trajectories when applied to a stiff artificial finger (simulating spasticity). The results, therefore, demonstrate that the proposed approach is indeed an effective solution for the envisioned soft hand exoskeleton system.


Assuntos
Biomimética , Exoesqueleto Energizado , Humanos , Extremidade Superior , Mãos , Tendões
9.
Sensors (Basel) ; 23(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36772153

RESUMO

Recording electrical muscle activity using a dense matrix of detection points (high-density electromyography, EMG) is of interest in a range of different applications, from human-machine interfacing to rehabilitation and clinical assessment. The wider application of high-density EMG is, however, limited as the clinical interfaces are not convenient for practical use (e.g., require conductive gel/cream). In the present study, we describe a novel dry electrode (TEX) in which the matrix of sensing pads is screen printed on textile and then coated with a soft polymer to ensure good skin-electrode contact. To benchmark the novel solution, an identical electrode was produced using state-of-the-art technology (polyethylene terephthalate with hydrogel, PET) and a process that ensured a high-quality sample. The two electrodes were then compared in terms of signal quality as well as functional application. The tests showed that the signals collected using PET and TEX were characterised by similar spectra, magnitude, spatial distribution and signal-to-noise ratio. The electrodes were used by seven healthy subjects and an amputee participant to recognise seven hand gestures, leading to similar performance during offline analysis and online control. The comprehensive assessment, therefore, demonstrated that the proposed textile interface is an attractive solution for practical applications.


Assuntos
Hidrogéis , Têxteis , Humanos , Eletromiografia , Eletrodos , Pele
10.
Sensors (Basel) ; 22(19)2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36236758

RESUMO

Electrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding). Additionally, a procedure for a fast amplitude calibration, that includes a semi-automated initialization and an optional manual adjustment, was employed and evaluated. Twenty subjects, including twelve first responders, participated in the study. The electrode comprising the 3 × 2 matrix of pads was placed on the lateral torso. The results showed that high SRs could be achieved for both types of message encoding after a short learning phase; however, the dynamic approach led to a statistically significant improvement in messages recognition (SR of 93.3%), compared to static stimulation (SR of 83.3%). The proposed calibration procedure was also effective since in 83.8% of the cases the subjects did not need to adjust the stimulation amplitude manually.


Assuntos
Tronco , Tato , Calibragem , Comunicação , Estimulação Elétrica/métodos , Eletrodos , Humanos , Tato/fisiologia
11.
IEEE Int Conf Rehabil Robot ; 2022: 1-5, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36176131

RESUMO

Rehabilitation of the upper extremity (UE) is an essential part of the process following an acquired brain injury, where robot technologies have the potential of making the rehabilitation more intensive and effective. However, the implementation of robot technologies in a clinical setting can be complicated and not always successful. The aim of this study was to evaluate the implementation of the robot technology Armeo®Spring (Hocoma, Volketswil, Switzerland) at a specialized neurorehabilitation center, and to propose a list of actions for further implementation of the technology.The Study, Act and Plan phases of the Plan-Do-Study-Act (PDSA) model for structuring technology implementations was applied as the methodological framework in this study. In the Study-phase, nine semi-structured interviews with therapists, using Armeo®Spring, were conducted to evaluate the current implementation. In the Act-phase, a workshop was held with 13 participants to discuss the findings of the Study-phase and to find possible solutions to the identified problems. The results were incorporated into a list of actions (Plan-phase) for further implementation of Armeo®Spring.Facilitating and inhibiting factors for the implementation of Armeo®Spring were identified. Facilitating factors were the practical "hands-on" approach during training, support from the management, support and sparring with colleagues as well as a positive work culture. The inhibiting factors were related to the retention of the therapists' acquired competencies, the identification of the type of patient that can benefit from this form of training, challenges due to the technical use of Armeo®Spring, and prioritization of the rehabilitation needs of the patients.Several solutions were proposed in the Act-phase, which subsequently resulted in eight concrete actions to facilitate the further implementation of Armeo®Spring. It is expected that these actions will contribute to the further implementation of Armeo®Spring at the neurorehabilitation center. As a first step, an Armeo®Spring group with therapists from all relevant wards was established.


Assuntos
Reabilitação Neurológica , Extremidade Superior , Mãos , Humanos
12.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36176153

RESUMO

Early rehabilitation is beneficial for stroke patients, but it is often delayed since the patients are often bedbound due to their general condition. New robotic rehabilitation devices such as ROBERT® enable patients to exercise even while bedbound. During pilot testing of an automated FES-delivery system combined with ROBERT®, we observed both increased and decreased exerted velocity and interaction force during repetitive exercising with the system. The goal of the current study was thus to investigate the extent of both potentiation and fatigue, as assessed in the velocity and interaction force produced in response to repetitive robotic-FES exercising. Eight healthy subjects completed 50 repetitions of leg-press exercises using the hybrid robotic-FES system. For individual subjects, significant changes were found for both mean and maximal velocities and interaction forces exerted during the exercise. Roughly half of the subjects had an increase in maximal velocity and interaction force during the exercise, and half exhibited an increase in mean velocity, whereas three subjects had an increase in mean interaction force during the exercise. The changes in mean velocity were in the range of -40.6 to 30.9% and for the maximal velocity they were in the range of -21.9 to 22.0%. The changes for mean interaction force were in the range of -5.8 to 11.0%, while for the maximal interaction force, they were in the range of -7.8 to 14.4%. These changes might pose significant challenges for future developments of hybrid robotic-FES rehabilitation systems, as the system must be able to comply with the observed changes, and appropriately adapt to them in order to maintain efficacy and safety.


Assuntos
Terapia por Estimulação Elétrica , Procedimentos Cirúrgicos Robóticos , Robótica , Exercício Físico/fisiologia , Terapia por Exercício , Humanos
13.
J Neuroeng Rehabil ; 19(1): 78, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864513

RESUMO

BACKGROUND: Myoelectric control based on hand gesture classification can be used for effective, contactless human-machine interfacing in general applications (e.g., consumer market) as well as in the clinical context. However, the accuracy of hand gesture classification can be impacted by several factors including changing wrist position. The present study aimed at investigating how channel configuration (number and placement of electrode pads) affects performance in hand gesture recognition across wrist positions, with the overall goal of reducing the number of channels without the loss of performance with respect to the benchmark (all channels). METHODS: Matrix electrodes (256 channels) were used to record high-density EMG from the forearm of 13 healthy subjects performing a set of 8 gestures in 3 wrist positions and 2 force levels (low and moderate). A reduced set of channels was chosen by applying sequential forward selection (SFS) and simple circumferential placement (CIRC) and used for gesture classification with linear discriminant analysis. The classification success rate and task completion rate were the main outcome measures for offline analysis across the different number of channels and online control using 8 selected channels, respectively. RESULTS: The offline analysis demonstrated that good accuracy (> 90%) can be achieved with only a few channels. However, using data from all wrist positions required more channels to reach the same performance. Despite the targeted placement (SFS) performing similarly to CIRC in the offline analysis, the task completion rate [median (lower-upper quartile)] in the online control was significantly higher for SFS [71.4% (64.8-76.2%)] compared to CIRC [57.1% (51.8-64.8%), p < 0.01], especially for low contraction levels [76.2% (66.7-84.5%) for SFS vs. 57.1% (47.6-60.7%) for CIRC, p < 0.01]. For the reduced number of electrodes, the performance with SFS was comparable to that obtained when using the full matrix, while the selected electrodes were highly subject-specific. CONCLUSIONS: The present study demonstrated that the number of channels required for gesture classification with changing wrist positions could be decreased substantially without loss of performance, if those channels are placed strategically along the forearm and individually for each subject. The results also emphasize the importance of online assessment and motivate the development of configurable matrix electrodes with integrated channel selection.


Assuntos
Gestos , Punho , Algoritmos , Eletrodos , Eletromiografia/métodos , Mãos , Humanos , Articulação do Punho
14.
Artif Organs ; 46(10): 2044-2054, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35712803

RESUMO

BACKGROUND: Tactile stimulation can be used to convey information to a user in different scenarios while avoiding overloading other senses. Tactile messages can be transmitted as spatial patterns, potentially allowing for a high information throughput. The aim of the present study was to design and test different encoding schemes to determine the best approach for conveying spatial patterns. METHODS: Encoding schemes with simultaneous (SIM) and sequential pad activation (SEQ) were evaluated, including four SEQ variants designed to potentially facilitate the recognition. In SEQ-col and SEQ-row, the column and row of the activated pad were signified using different frequencies, while SEQ-all and SEQ-all-fast included the activation of all pads where those belonging to the pattern were indicated by changes in frequency (ON pads). The success rate (SR) of the pattern identification and the response time were quantified in 15 participants who recognized 20 patterns delivered through a 3 × 2 pad matrix placed on the lateral torso. RESULTS: SIM was not a feasible method to present the patterns (median, 15%; IQR, 5%). The SR improved with SEQ (median, 60%; IQR, 20%) and further increased with additional cues, particularly with SEQ-row (median, 78.3%; IQR, 23.3%) and SEQ-all (median, 96.7%; IQR, 5%). Importantly, the stimulation time of SEQ-all could be decreased without a substantial drop in accuracy (SEQ-all-fast: median, 89.2%; IQR, 19.2%). CONCLUSIONS: The spatiotemporal stimulation with sequential activation of all pads (SEQ-all) seems to be the method of choice when conveying tactile messages as spatial patterns. This is an important outcome for increasing the information bandwidth of communication through the tactile channel.


Assuntos
Percepção do Tato , Tato , Estimulação Elétrica , Eletrodos , Humanos , Pele , Tronco , Tato/fisiologia , Percepção do Tato/fisiologia
16.
Front Psychol ; 13: 806861, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35250738

RESUMO

Interactive sonification of biomechanical quantities is gaining relevance as a motor learning aid in movement rehabilitation, as well as a monitoring tool. However, existing gaps in sonification research (issues related to meaning, aesthetics, and clinical effects) have prevented its widespread recognition and adoption in such applications. The incorporation of embodied principles and musical structures in sonification design has gradually become popular, particularly in applications related to human movement. In this study, we propose a general sonification model for the sit-to-stand (STS) transfer, an important activity of daily living. The model contains a fixed component independent of the use-case, which represents the rising motion of the body as an ascending melody using the physical model of a flute. In addition, a flexible component concurrently sonifies STS features of clinical interest in a particular rehabilitative/monitoring situation. Here, we chose to represent shank angular jerk and movement stoppages (freezes), through perceptually salient pitch modulations and bell sounds. We outline the details of our technical implementation of the model. We evaluated the model by means of a listening test experiment with 25 healthy participants, who were asked to identify six normal and simulated impaired STS patterns from sonified versions containing various combinations of the constituent mappings of the model. Overall, we found that the participants were able to classify the patterns accurately (86.67 ± 14.69% correct responses with the full model, 71.56% overall), confidently (64.95 ± 16.52% self-reported rating), and in a timely manner (response time: 4.28 ± 1.52 s). The amount of sonified kinematic information significantly impacted classification accuracy. The six STS patterns were also classified with significantly different accuracy depending on their kinematic characteristics. Learning effects were seen in the form of increased accuracy and confidence with repeated exposure to the sound sequences. We found no significant accuracy differences based on the participants' level of music training. Overall, we see our model as a concrete conceptual and technical starting point for STS sonification design catering to rehabilitative and clinical monitoring applications.

17.
Biomed Phys Eng Express ; 7(6)2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34431480

RESUMO

Introduction.Event-related desynchronization (ERD) is used in brain-computer interfaces (BCI) to detect the user's motor intention (MI) and convert it into a command for an actuator to provide sensory feedback or mobility, for example by means of functional electrical stimulation (FES). Recent studies have proposed to evoke the nociceptive withdrawal reflex (NWR) using FES, in order to evoke synergistic movements of the lower limb and to facilitate the gait rehabilitation of stroke patients. The use of NWR to provide sensorimotor feedback in ERD-based BCI is novel; thererfore, the conditioning effect that nociceptive stimuli might have on MI is still unknown.Objetive.To assess the ERD produced during the MI after FES-evoked NWR, in order to evaluate if nociceptive stimuli condition subsequent ERDs.Methods. Data from 528 electroencephalography trials of 8 healthy volunteers were recorded and analyzed. Volunteers used an ERD-based BCI, which provided two types of feedback: intrisic by the FES-evoked NWR and extrinsic by virtual reality. The electromyogram of the tibialis anterior muscle was also recorded. The main outcome variables were the normalized root mean square of the evoked electromyogram (RMSnorm), the average electroencephalogram amplitude at the ERD frequency during MI (A¯MI) and the percentage decrease ofA¯MIrelative to rest (ERD%) at the first MI subsequent to the activation of the BCI.Results.No evidence of changes of theRMSnormon both theA¯MI(p = 0.663) and theERD%(p = 0.252) of the subsequent MI was detected. A main effect of the type of feedback was found in the subsequentA¯MI(p < 0.001), with intrinsic feedback resulting in a largerA¯MI.Conclusions.No evidence of ERD conditioning was observed using BCI feedback based on FES-evoked NWR .Significance.FES-evoked NWR could constitute a potential feedback modality in an ERD-based BCI to facilitate motor recovery of stroke people.


Assuntos
Estimulação Elétrica , Retroalimentação , Interfaces Cérebro-Computador , Humanos , Nociceptividade , Reflexo , Acidente Vascular Cerebral
18.
IEEE Int Conf Rehabil Robot ; 2019: 1073-1078, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31374772

RESUMO

A new tendon driven mechanism, embedded into a soft hand exoskeleton for rehabilitation and assistance, was proposed in this study. The proposed solution was a pulley flexion mechanism inspired by the human musculoskeletal system to enable a natural and comfortable finger flexion. A biomechanical constraint for the finger flexion motion states that the relation between the proximal interphalangeal joint angle of the finger should always be flexed around 1.5 times the distal interphalangeal joint angle. The study aimed to comply with this constraint, by simultaneously distributing the forces over the distal and middle finger phalanges. For evaluation, the voluntary and exoskeleton flexions were compared based on the relation between the proximal and distal interphalangeal joint angles. The results showed that during the exoskeleton flexion the relation between the interphalangeal joints complied with the biomechanical constraint, where the proximal interphalangeal joint angle was 1.5 times larger than the distal interphalangeal joint. This ensures that the mechanism flexes the finger comfortably. The proposed solution is therefore a promising design for a novel soft exoskeleton that will be used for training and assistance of patients with hand paralysis.


Assuntos
Exoesqueleto Energizado , Articulações dos Dedos/fisiologia , Tendões/fisiologia , Adulto , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia
19.
IEEE Rev Biomed Eng ; 12: 138-153, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30561350

RESUMO

With the existence of numerous rehabilitation systems, classification and comparison becomes difficult, especially due to the many factors involved. Moreover, most current reviews are descriptive and do not provide systematic methods for the visual comparison of systems. This review proposes a method for classifying systems and representing them graphically to easily visualize various characteristics of the different systems at the same time. This method could be an introduction for standardizing the evaluation of gait rehabilitation systems. It evaluates four main modules (body weight support, reciprocal stepping mechanism, pelvis mechanism, and environment module) of 27 different gait systems based on a set of characteristics. The combination of these modular evaluations provides a description of the system "in the space of rehabilitation." The evaluation of each robotic module, based on specific characteristics, showed diverse tendencies. While there is an augmented interest in developing more sophisticated reciprocal stepping mechanisms, few researchers are dedicated to enhance the properties of pelvis mechanisms.


Assuntos
Transtornos Neurológicos da Marcha/reabilitação , Marcha/fisiologia , Robótica , Telerreabilitação/tendências , Fenômenos Biomecânicos/fisiologia , Desenho de Equipamento , Transtornos Neurológicos da Marcha/fisiopatologia , Humanos , Pelve/fisiopatologia
20.
IEEE Trans Neural Syst Rehabil Eng ; 26(5): 1100-1107, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29752246

RESUMO

In gait rehabilitation, combining gait therapy with functional electrical stimulation based on the nociceptive withdrawal reflex (NWR) improves walking velocity and gait symmetry of hemiparetic patients. However, habituation of the NWR can affect the efficacy of training. The current study aimed at identifying the stimulation parameters that would limit, in healthy participants, the habituation of the NWR. The NWR was elicited at every heel-off while the participants walked on a treadmill. Three stimulation paradigms were tested: deterministic paradigm (fixed parameters), stochastic pulse duration paradigm (varying the pulse duration of the stimuli), and stochastic frequency paradigm (varying the frequency of the stimuli). The charge delivered for the three paradigms was identical. The reflex response was quantified by the EMG activity of the tibialis anterior (TA) muscle and as ankle and hip joints angle changes. The ankle dorsiflexion and TA EMG responses were not significantly reduced with the stochastic pulse duration paradigm, in contrast to the two other paradigms. Hence, using a stochastic pulse duration stimulation paradigm seemed to be effective in limiting the habituation of the NWR in heathy individuals. This might be highly relevant for effective gait rehabilitation.


Assuntos
Habituação Psicofisiológica/fisiologia , Nociceptividade/fisiologia , Reflexo/fisiologia , Adulto , Articulação do Tornozelo , Fenômenos Biomecânicos , Estimulação Elétrica , Eletromiografia , Feminino , Transtornos Neurológicos da Marcha/reabilitação , Voluntários Saudáveis , Articulação do Quadril , Humanos , Masculino , Músculo Esquelético/fisiologia , Medição da Dor , Processos Estocásticos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS