Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Perit Dial Int ; 27 Suppl 2: S119-25, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17556289

RESUMO

The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.


Assuntos
Cateteres de Demora , Diálise Peritoneal/instrumentação , Cateteres de Demora/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Humanos , Infecções/etiologia , Falência Renal Crônica/terapia , Satisfação do Paciente , Qualidade de Vida
2.
Perit Dial Int ; 27 Suppl 2: S130-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17556291

RESUMO

Automated peritoneal dialysis (APD) has undergone substantial growth in recent years because of an increased demand for higher doses of peritoneal dialysis (PD) treatment and a need to improve quality of life for patients. The evolution of this treatment is closely linked with the development of new automatic machines and with recent advances in prescription and monitoring of PD treatment. In the present article, we describe the characteristics of the new generation of APD cyclers with particular regard to adequacy targets and safety. There is renewed interest in continuous-flow peritoneal dialysis (CFPD), because of a belief that new peritoneal access technologies will make the success of this modality a possibility. In the CFPD technique, a certain amount of fluid is constantly present in the abdomen, and constant inflow and outflow are maintained without interruption thanks to paired indwelling catheters. The PD solution is used either in a single pass or in a recirculation loop with a regeneration systems (sorbent cartridge or dialyzer).


Assuntos
Diálise Peritoneal/tendências , Automação , Transporte Biológico/fisiologia , Soluções para Diálise/farmacocinética , Desenho de Equipamento , Humanos , Diálise Peritoneal/instrumentação , Interface Usuário-Computador
3.
Contrib Nephrol ; 150: 226-234, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16721014

RESUMO

The real integration of a specific therapy into the renal replacement program is represented by the possibility of easy and free patient transfer from one treatment to another without restrictions. In the case of peritoneal dialysis we feel that its integration in the therapeutic approach of uremia represents an ethical obligation for the physician, a clinical opportunity for the patient and a good cost/benefit solution for care givers. A full conviction that peritoneal dialysis represents a real therapeutic option for ESRD patients is necessary to achieve a real integration of this therapy in the uremia treatment program. A positive cost benefit ratio, both from the clinical and the economical points of view must also be seeked. The patient indirectly, must receive the same positive conviction, based on solid data and clinical results, comparable to those achievable in hemodialysis. Furthermore the patient must know that such treatment will provide an equal opportunity for kidney transplant compared to other therapies. Such a kind of feeling and knowledge must include information on patient's survival, rate of complications, treatment adequacy, availability of different techniques within the treatment and complete summary of advantages and disadvantages.


Assuntos
Falência Renal Crônica/terapia , Diálise Peritoneal , Uremia/terapia , Humanos , Uremia/reabilitação
4.
Contrib Nephrol ; 150: 326-335, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16721026

RESUMO

Fluid overload and uncontrolled hypertension may be considered important mortality risk factors in peritoneal dialysis (PD) population. Even malnutrition is highly prevalent in PD patients. It is now well established that lower levels of serum markers of nutrition such as albumin, creatinine, and prealbumin are associated with increased mortality in PD patients [Fein, P.A. et al: Adv Perit Dial 2002;18:195-199]. Moreover cardiovascular disease is a leading cause of death in patients with end-stage renal disease, and hypertension and volume expansion are highly prevalent in long-term PD patients. Many studies in hemodialysis and in PD have demonstrated that phase sensitive bioelectrical impedance analysis is a widely used and proven method for evaluating patient's body composition. The vectorial bioimpedance analysis is a validated system to evaluate the hydration and nutritional state of hemodialysis and PD patients with acceptable sensitivity and specificity. The aim of this study is to evaluate the reliability and accuracy of the new multifrequency BodyComp bioimpedance analyzer as a home based tool versus traditional Bia Vector.


Assuntos
Composição Corporal , Água Corporal/metabolismo , Estado Nutricional , Diálise Peritoneal/instrumentação , Adulto , Idoso , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA