RESUMO
PURPOSE: To describe a novel technique to repair a juxtarenal abdominal aortic aneurysm (JAAA) after failed endovascular aortic repair (EVAR) with severely kinked anatomy. TECHNIQUE: We present a patient who underwent an EVAR with a Medtronic Talent device 15 years ago and a proximal cuff extension 3 years earlier for an abdominal aortic aneurysm. Computed tomography (CT) done for a known gastritis showed a 12 cm JAAA, with a migrated endograft and a type Ia endoleak (EL). Endovascular repair was performed, accessing and navigating the aneurysmal sac outside the previous graft. The type I EL was reached and the suprarenal aorta catheterized. A 4-vessel inner-branched EVAR device was deployed in the distal thoracic aorta and their target vessels bridged through femoral access. A distal bifurcated component was deployed and both iliac limbs were extended to the native distal iliac arteries. Completion angiogram as well as early and 12-month CT showed a fully patent straight course branched EVAR with no ELs. CONCLUSION: Complex aortic reinterventions in the presence of previous EVAR can be performed by choosing a straighter course along and parallel to the previous endograft. Several technical aspects must be considered to successfully perform this type of reinterventions. CLINICAL IMPACT: We present a technique of a complex endovascular aortic repair in a failed EVAR with kinked anatomy, navigating through the thrombosed aneurysmal sac, outside the previously placed endograft and thus obtaining a straighter path for a new branched endograft. The novelty lies in a different approach to repair a failed EVAR with a branched graft through an uncommon access on the side of the previous endograft, avoiding repeated displacement or occlusion of the new endograft. We exemplify the feasibility of such a complex procedure and highlight important steps to perform it, whether in the abdominal or even thoracic Aorta.