Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
J Med Vasc ; 49(2): 90-97, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38697715

RESUMO

AIM: The treadmill walking test with post-exercise pressure measurement can be used as a diagnostic test and could classify peripheral arterial disease of the lower limbs. It can also exclude the diagnosis allowing to raise the possibility of differential diagnoses. In this study, we assessed the feasibility of performing treadmill test by advanced practice nurse to assess suspected lower extremity peripheral artery disease patients. DESIGN AND METHOD: This is a longitudinal monocentric study to assess the feasibility of a treadmill walking test performed by an advanced practice nurse. The primary endpoint was the number of tests performed during this period. The secondary objectives were to evaluate the reasons for requesting the test, the main results obtained in terms of the test's contribution and diagnoses, and patients' clinical characteristics. RESULTS: From February to May 2023, amongst 31 patients who underwent the treadmill walking test, 4 tests were able to rule out peripheral arterial disease and to detect differential diagnoses. For the remaining 27 patients, 4 had stage IIa of the Leriche classification, 23 had stage IIb, 2 of which were associated with a narrow lumbar spine. In contrast to the usual report, the APN's report on the walking test included an identification of cardiovascular risk factors, as well as a possible medical reorientation linked to the correction of a detected cardiovascular risk factor. CONCLUSION: The treadmill walking test can be performed by an advanced practice nurse. He/She added a comprehensive/global patient management, with the detection of cardiovascular risk factors. This new profession led to an increase in the number of tests performed of more than 50% over the period and reduced the time to access the test.


Assuntos
Prática Avançada de Enfermagem , Estudos de Viabilidade , Doença Arterial Periférica , Valor Preditivo dos Testes , Teste de Caminhada , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Longitudinais , Teste de Esforço , Caminhada
2.
Ann Cardiol Angeiol (Paris) ; 73(1): 101708, 2024 Feb.
Artigo em Francês | MEDLINE | ID: mdl-38000339

RESUMO

The endovascular approach is widely used in the management of aortic isthmic rupture. Even if it remains less invasive than conventional surgery, a life-threatening complications are possible. We report the case of a young female patient presenting a stent-graft migration during the deployment with total obstruction of the supra-aortic vessels. We describe the therapeutic management with a cerebral rescue procedure followed by a delayed surgical repair.


Assuntos
Aneurisma da Aorta Torácica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Implante de Prótese Vascular/métodos , Stents/efeitos adversos , Resultado do Tratamento , Ruptura Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia
3.
Br J Surg ; 105(4): 358-365, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29488644

RESUMO

BACKGROUND: Surgical repair of aortic arch pathology is complex and associated with significant morbidity and mortality. Alternative approaches have been developed to reduce these risks, including the use of thoracic stent-grafts with fenestrations or in combination with bypass procedures to maintain supra-aortic trunk blood flow. Branched stent-grafts are a novel approach to treat aortic arch pathology. METHODS: Consecutive patients with aortic arch disease presenting to a single university hospital vascular centre were considered for branched stent-graft repair (October 2010 to January 2017). Patients were assessed in a multidisciplinary setting including a cardiologist, cardiac surgeon and vascular surgeon. All patients were considered prohibitively high risk for standard open surgical repair. The study used reporting standards for endovascular aortic repair and PROCESS (Preferred Reporting of Case Series in Surgery) guidelines. RESULTS: Some 30 patients (25 men) underwent attempted branch stent-graft repair. Mean age was 68 (range 37-84) years. Eighteen patients had chronic aortic dissection, 11 patients had an aneurysm and one had a penetrating ulcer. Fourteen patients had disease in aortic arch zone 0, six in zone 1 and ten in zone 2. Twenty-five patients had undergone previous aortic surgery and 24 required surgical revascularization of the left subclavian artery. Technical success was achieved in 27 of 30 patients. Four patients had an endoleak (type Ia, 1; type II, 3). The in-hospital mortality rate was three of 30. Mean length of follow-up was 12·0 (range 1·0-67·8) months, during which time 12 patients required an aortic-related reintervention. CONCLUSION: Repair of aortic arch pathology using branched stent-grafting appears feasible. Before widespread adoption of this technology, further studies are required to standardize the technique and identify which patients are most likely to benefit.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/mortalidade , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Rev Med Pharmacol Sci ; 21(11): 2717-2724, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28678313

RESUMO

OBJECTIVE: The aim of this study was to evaluate a new 3D Workstation workflow (EVAR Assist, Advantage Windows, GE Healthcare, Chalfont, UK) (EA-AW) designed to simplify complex EVAR planning. PATIENTS AND METHODS: All pre-operative computed tomography (CT) scans of patients who underwent repair at our institution of a complex aortic aneurysm using fenestrated endovascular repair (f-EVAR) between January and September 2014, were reviewed. For each patient, imaging analysis (12 measures: aortic diameters and length and "clock position" of visceral artery) was performed on two different workstations: Aquarius (TeraRecon, San Mateo, CA, USA) and EA-AW. According to a standardized protocol, three endovascular surgeons experienced in aortic endograft planning, performed image analyses and data collection independently. We analyzed an internal assessment between observers (on the Aquarius 3DWS) and an external assessment comparing these results with the planning center (PC) data used to custom the fenestrated endograft of the patients enrolled in this study. Finally, we compared both 3DWS data to determine the accuracy and the reproducibility. A p-value < .05 was considered as statistically significant. Complete agreement between operators was defined as 1.0. RESULTS: Intra- and inter-observer variability (interclass correlation coefficients - ICC: 0.81-.091) was very low and confirmed the reliability of our planners. The ICC comparison between EA-AW and Aquarius was excellent (> 0.8 for both), thus confirming the reproducibility and reliability of the new EA-AW application. Aortic and iliac necks diameters and lengths were similarly reported with both workstations. In our study, the mean difference in distance and orientation evaluation of target vessels evaluated by the two workstations was marginal and has no impact on clinical practice in term of device manufacturing. CONCLUSIONS: We showed that complex EVAR planning can be performed with this new dedicated 3D workstation workflow with a good reproducibility.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular , Imageamento Tridimensional/métodos , Software/normas , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
5.
Eur J Vasc Endovasc Surg ; 53(1): 95-102, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27889203

RESUMO

OBJECTIVE: To assess short- and long-term movement of renal arteries after fenestrated endovascular aortic repair (FEVAR). METHODS: Consecutive patients who underwent FEVAR at one institution with a custom-made device designed with fenestrations for the superior mesenteric (SMA) and renal arteries, a millimetric computed tomography angiography (CTA), and a minimum of 2 years' follow-up were included. Angulation between renal artery trunk and aorta, clock position of the origin of the renal arteries, distance between renal arteries and SMA, and target vessel occlusion were retrospectively collected and compared between the pre-operative, post-operative (<6 months), and last (>12 months) CTA. RESULTS: From October 2004 to January 2014, 100 patients met the inclusion criteria and 86% of imaging was available for accurate analysis. Median follow-up was 27.3 months (22.7-50.1). There were no renal occlusions. A significant change was found in the value of renal trunk angulation of both renal arteries on post-operative compared with pre-operative CTA (17° difference upward [7.5-29], p < .001), but no significant change thereafter (p = .5). Regarding renal clock positions (7.5° of change equivalent to 15 min of renal ostial movement): significant anterior change was found between post-operative and pre-operative CTA (15 min [0-30], p = .03 on the left and 15 min [15-30], p < .001 on the right), without significant change thereafter (15 min [0-30], p = .18 on the left and 15 min [0-15] on the right, p = .28). No changes were noted on the distance between renal and SMA ostia (difference of 1.65 mm [1-2.5], p = .63). CONCLUSION: The renal arteries demonstrate tolerance to permanent changes in angulation after FEVAR of approximately 17° upward trunk movement and of 15-30 min ostial movement without adverse consequences on patency after a median of more than 2 years' follow-up. The distance between the target vessels remained stable over time. These results may suggest accommodation to sizing errors and thus a compliance with off the shelf devices in favourable anatomies.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/instrumentação , Artéria Renal/anatomia & histologia , Artéria Renal/diagnóstico por imagem , Stents , Aorta/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Seguimentos , Humanos , Artéria Mesentérica Superior/diagnóstico por imagem , Desenho de Prótese
6.
Eur J Vasc Endovasc Surg ; 51(3): 380-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26818022

RESUMO

OBJECTIVES: The aim was to evaluate the current results of aortic arch aneurysm repair using inner branched endografts performed in three high volume aortic endovascular centers and to compare them to the pioneering global experience with this technology. METHODS: Included patients underwent repair of aortic arch aneurysms >55 mm in diameter using inner branched endograft technology between April 2013 and November 2014. All patients were deemed unfit for open surgery. Inner branches were designed to perfuse the brachiocephalic trunk and the left common carotid artery in all cases. A left subclavian artery (LSA) revascularization was performed prior to the arch endovascular repair. Data were collected retrospectively in an electronic database. Parameters included length of procedure, fluoroscopy time, contrast volume, technical success, presence of endoleaks, early and late complications, and mortality. RESULTS: Twenty-seven patients were included in the study. Technical success was achieved in all cases. No patients died during the 30 day post-operative period. Early neurologic events included two major strokes (7.4%) and one minor stroke (3.7%). Transient spinal cord ischemia with full recovery was observed in two patients (7.4%). Four patients (14.8%) underwent early (<30 day) re-interventions; these were for an access complication, an ischemic limb and exploration of the left ventricle through a sternotomy in two patients. During follow up (median 12 months), one patient (3.7%) died from a remote thoraco-abdominal aneurysm rupture. There were three Type 2 endoleaks (11.1%). Two re-interventions (7.4%) were performed, one to treat a Type 2 endoleak and one to treat a septic false aneurysm. A significant decrease in overall mortality was observed when comparing patients from the early experience with patients from the current report. CONCLUSIONS: The early outcomes associated with this technology are favorable. Branched endografting of aortic arch aneurysms should be considered in patients unfit for open surgery.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Enxerto Vascular/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
Eur J Vasc Endovasc Surg ; 51(4): 488-97, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26680449

RESUMO

OBJECTIVES: Outcomes are reported in management of post-dissection aneurysms involving the aortic arch and/or thoraco-abdominal segment (TAAA) treated with fenestrated and branched (complex) endografts. METHODS: This report includes all patients with chronic post-dissection aneurysms >55 mm in diameter, deemed unfit for open surgery, treated using complex endografts between October 2011 and March 2015. When appropriate, staged management strategies including left subclavian artery revascularization, thoracic endografting, dissection flap fenestration or tear enlargement, and other endovascular procedures were performed at least 3 weeks prior to definitive complex endovascular repair. The following outcome data were collected prospectively at discharge, 12 months and annually thereafter: technical success, endoleaks, target vessel patency, false lumen patency, aneurysm diameter, major and minor complications, re-interventions, and mortality. RESULTS: The cohort comprised 23 patients with a median age of 65 years. Staged procedures were performed in 14 patients (61%). Seven patients with dissections involving the arch were treated with inner branched endografts, and 16 TAAA patients were treated with fenestrated or branched endografts. The technical success rate was 71% following arch repair and 100% following TAAA repair. During early follow up, one of the arch group patients died and one in the TAAA group suffered spinal cord ischemia. The median follow up was 12 months (range 3-48), during which time one patient died of causes unrelated to aneurysm or treatment. Two early re-interventions were performed in the arch group to correct access vessel complications and there were a further two late re-interventions in the TAAA group to treat endoleaks. All target vessels (n = 72) remained patent. CONCLUSIONS: This experience indicates that complex endovascular repair of post-dissection aneurysms is a viable alternative to open repair in patients deemed unfit for open surgery. There are insufficient data to allow comparison with the outcome of open surgery in anatomically similar, but fit, patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Desenho de Prótese , Retratamento , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Eur J Vasc Endovasc Surg ; 50(4): 420-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26021528

RESUMO

OBJECTIVE: The purpose of this study was to analyze immediate and long-term renal outcomes (renal function and renal events) after fenestrated (FEVAR) and branched endovascular aortic aneurysm repair (BEVAR). METHODS: All FEVAR and BEVAR performed between October 2004 and October 2012 were included in this study. Post-operative acute renal failure (ARF) was defined according to the RIFLE criteria. Renal volume (calculated with a 3D workstation) and estimated glomerular filtration rate (GFR) (estimated with the Modification of Diet in Renal Disease [MDRD] formula) were evaluated before the procedure, before discharge, 12 months after, and yearly thereafter. Renal stent occlusion, dissection, fracture, stenosis, kink, renal stent related endoleak, and renal stent secondary intervention were all considered "renal composite events" and analyzed. A time to event analysis was performed for renal events and secondary renal interventions. RESULTS: 225 patients were treated with FEVAR and BEVAR. Renal target vessels (n = 427) were perfused by fenestrations (n = 374), or branches (n = 53). Median follow up was 3.1 years (2.9-3.3 years). Technical success was achieved in 95.5% of patients. Post-operative ARF was seen in 64 patients (29%). Mean total renal volume and eGFR at 1 year, 2 year, and 3 year follow up were significantly lower when compared with pre-operative levels (after BEVAR and FEVAR); the decrease at 3 years was 14.8% (6.7%; 22.2%) (p = .0006) for total renal volume and 14.3% (3.1%; 24.3%) (p = .02) for eGFR. The 30 day and 5 year freedom from renal composite event was 98.6% (95.8-99.6%) and 84.5% (76.5-89.9%) after FEVAR and BEVAR (NS). The 30 day and 5 year freedom from renal occlusion was 99.5% (96.7-99.9%) and 94.4% (89.3-97.1%) after FEVAR and BEVAR (NS). CONCLUSION: FEVAR and BEVAR are durable options for the treatment of complex aortic aneurysms and are associated with low renal morbidity, without differences between devices types. The clinical impact of decreasing renal volume over time in these patients is yet to be fully understood.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Nefropatias/etiologia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Taxa de Filtração Glomerular , Humanos , Rim/fisiopatologia , Nefropatias/diagnóstico , Nefropatias/mortalidade , Nefropatias/fisiopatologia , Nefropatias/terapia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Eur J Vasc Endovasc Surg ; 49(5): 541-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25752417

RESUMO

OBJECTIVES: This study evaluated a new strategy to assess technical success after standard and complex endovascular aortic repair (EVAR), combining completion contrast enhanced cone beam computed tomography (ceCBCT) and post-operative contrast enhanced ultrasound (CEUS). METHODS: Patients treated with bifurcated or fenestrated and branched endografts in the hybrid room during the study period were included. From December 2012 to July 2013, a completion angiogram (CA) was performed at the end of the procedure, and computed tomography angiography (CTA) before discharge (group 1). From October 2013 to April 2014, a completion ceCBCT was performed, followed by CEUS during the 30 day post-operative period (group 2). The rate of peri-operative events (type I or III endoleaks, kinks, occlusion of target vessels), need for additional procedures or early secondary procedures, total radiation exposure (mSv), and total volume of contrast medium injected were compared. RESULTS: Seventy-nine patients were included in group 1 and 54 in group 2. Peri-operative event rates were respectively 8.9% (n = 7) and 33.3% (n = 18) (p = .001). Additional procedures were performed in seven patients (8.9%) in group 1 versus 17 (31.5%) in group 2 (p = .001). Two early secondary procedures were performed in group 2 (3.7%), and three (3.8%) in group 1 (p = .978). Median radiation exposure due to CBCT was 7 Gy cm(2) (5.25-8) (36%, 27%, and 9% of the total procedure exposure, respectively for bifurcated, fenestrated, and branched endografts). CEUS did not diagnose endoleaks or any adverse events not diagnosed by ceCBCT. Overall radiation and volume of contrast injected during the patient hospital stay in groups 1 and 2 were 34 (25.8-47.3) and 11 (5-20.5) mSv, and 184 (150-240) and 91 (70-132.8) mL respectively (reduction of 68% and 50%, p < .001). CONCLUSIONS: Completion ceCBCT is achievable in routine practice to assess technical success after EVAR. Strategies to evaluate technical success combining ceCBCT and CEUS can reduce total in hospital radiation exposure and contrast medium volume injection.


Assuntos
Angiografia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Procedimentos Cirúrgicos Vasculares , Idoso , Angiografia/métodos , Implante de Prótese Vascular/métodos , Meios de Contraste/uso terapêutico , Endoleak/diagnóstico por imagem , Endoleak/cirurgia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia
10.
J Cardiovasc Surg (Torino) ; 56(2): 197-215, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25644831

RESUMO

The repair of aneurysms involving the aortic arch is technically and physiologically demanding. Historically, these aneurysms have been treated using open surgical techniques that require cardiopulmonary bypass and deep hypothermic circulatory arrest. Many patients have been deemed "untreatable" and among those selected for surgery there are reported risks of death in 2% to 16.5% and stroke rates ranging from 2% to 18%. "Hybrid arch repair" combines one of a number of open surgical procedures (to secure a proximal landing zone for an endograft) with subsequent or immediate placement of an endograft in the arch and descending aorta. Although this concept is described as "minimally invasive" because it avoids aortic cross-clamping and hypothermic circulatory arrest, the morbidity and mortality rates remain considerable (mortality 0% to 15%, stroke 0% to 11%). Ongoing development of endograft technology has enabled total endovascular repair of complex aortic aneurysms involving the visceral segment, using fenestrated and branched endografts. Encouraging early results in this anatomy have inspired extension of the concept to include the aortic arch and great vessels. These strategies can be considered in patients generally at high-risk for the conventional procedures. However, the endeavour is at an early stage of its development and the arch poses unique challenges including the potential for stroke, angulation of the arch and the great vessel ostia to the arch, extremely high volume flow, three-dimensional pulsation and rotation with the cardiac cycle and the proximity of the aortic valve and coronary arteries.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Humanos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fatores de Risco , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
Eur J Vasc Endovasc Surg ; 49(3): 248-54, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25575833

RESUMO

OBJECTIVE/BACKGROUND: Spinal cord ischemia (SCI) is a devastating complication following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. In an attempt to reduce its incidence two peri-procedural changes were implemented by the authors in January 2010: (i) all large sheaths are withdrawn from the iliac arteries immediately after deploying the central device and before cannulation and branch extension to the visceral vessels; (ii) the peri-operative protocol has been modified in an attempt to optimize oxygen delivery to the sensitive cells of the cord (aggressive blood and platelet transfusion, median arterial pressure monitoring >85 mmHg, and systematic cerebrospinal fluid drainage). METHODS: Between October 2004 and December 2013, 204 endovascular TAAA repairs were performed using custom made devices manufactured with branches and fenestrations to maintain visceral vessel perfusion. Data from all of these procedures were prospectively collected in an electronic database. Early post-operative results in patients treated before (group 1, n = 43) and after (group 2, n = 161 patients) implementation of the modified implantation and peri-operative protocols were compared. RESULTS: Patients in groups 1 and 2 had similar comorbidities (median age at repair 70.9 years [range 65.2-77.0 years]), aneurysm characteristics (median diameter 58.5 mm [range 53-65 mm]), and length of procedure (median 190 minutes [range 150-240 minutes]). The 30 day mortality rate was 11.6% in group 1 versus 5.6% in group 2 (p = .09). The SCI rate was 14.0% versus 1.2% (p < .01). If type IV TAAAs were excluded from this analysis, the SCI rate was 25.0% (6/24 patients) in group 1 versus 2.1% (2/95 patients) in group 2 (p < .01). CONCLUSION: The early restoration of arterial flow to the pelvis and lower limbs, and aggressive peri-operative management significantly reduces SCI following type I-III TAAA endovascular repair. With the use of these modified protocols, extensive TAAA endovascular repairs are associated with low rates of SCI.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Extremidade Inferior/irrigação sanguínea , Pelve/irrigação sanguínea , Isquemia do Cordão Espinal/prevenção & controle , Idoso , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Comorbidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , França/epidemiologia , Hospitais com Alto Volume de Atendimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Medição de Risco , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/mortalidade , Isquemia do Cordão Espinal/fisiopatologia , Stents , Fatores de Tempo , Resultado do Tratamento
12.
J Cardiovasc Surg (Torino) ; 55(4): 505-17, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24975737

RESUMO

The treatment of chronic aortic dissection is a major challenge for the vascular surgeon. Close imaging follow-up after the acute episode frequently identifies dilation of untreated aortic segments. Aortic dissection often extends to both the supra-aortic trunks and to the visceral aorta. The poor medical condition that often characterizes these patients may preclude extensive open surgical repair. Recent advances in endovascular techniques provide a valid alternative to open surgery. These complex lesions can now be managed using thoracic branched and fenestrated endografts. However, clinical data are scarce and only 3 small series from 3 high-volume aortic centers are currently available. Careful anatomical study on 3D workstations is mandatory to select patients that are candidates for complex endovascular exclusion; a specific focus on the available working space within the true lumen, extension to the arch and/or the visceral/renal arteries, and false lumen perfusion of visceral vessels is required. An excellent understanding of those anatomic details demands high-quality preoperative CTA. Intraoperative advanced imaging applications are a major adjunct in the achievement of technical success.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Dissecção Aórtica/diagnóstico , Aneurisma Aórtico/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Doença Crônica , Procedimentos Endovasculares/efeitos adversos , Humanos , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Eur J Vasc Endovasc Surg ; 48(2): 144-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24951372

RESUMO

INTRODUCTION: Endovascular repair of aortic arch aneurysms using an inner-branched device is a new treatment option for patients unfit for open surgery. There are many anatomical restrictions, such as the presence of a mechanical aortic valve that can contraindicate this complete endovascular approach. REPORT: A new delivery system to overcome this issue has been developed. This new system was used to treat an aortic arch aneurysm 77 mm in diameter in a 37-year-old patient with Marfan's syndrome. The patient was considered to be at major risk for open surgery because of severe respiratory insufficiency following a second sternotomy. DISCUSSION: Total endovascular arch aneurysm repair is no longer contraindicated in patients with a mechanical aortic valve.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Síndrome de Marfan/complicações , Adulto , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Seleção de Pacientes , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
Eur J Vasc Endovasc Surg ; 46(1): 82-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23664035

RESUMO

BACKGROUND: To assess the accuracy of the aortic outer curvature length for thoracic endograft planning. METHODS: Seventy-four patients (58 men, 66.4 ± 14 years) who underwent thoracic endovascular aortic repair between 2009 and 2011 treated with a Cook Medical endograft were enrolled in this retrospective study. Immediate postoperative CT scans were analysed using EndoSize software. Three vessel lengths were computed between two fixed landmarks placed at each end of the endograft: the straightline (axial) length, the centerline length and the outer curvature length. A tortuosity index was defined as the ratio of the centerline length/straightline length. A Student t test and a Pearson correlation coefficient were used to examine the results. RESULTS: We found a significant difference between the centerline length (135.4 ± 24 mm) and that of the endograft (160 ± 29 mm) (p < .0001). This difference correlates with the tortuosity index (r = .818, p < .0001), the endograft length (r = .587, p < .0001), and the diameter of the endograft (r = .53, p < .0001). However, the outer curvature length (161.3 ± 29 mm) and the endograft length (160 ± 29 mm) were similar (p = .792). CONCLUSION: The outer curvature length more accurately reflects that of the deployed endograft and may prove more accurate than centerlines in planning thoracic endografts.


Assuntos
Aorta Torácica/anatomia & histologia , Aorta Torácica/cirurgia , Prótese Vascular , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
Eur J Vasc Endovasc Surg ; 43(4): 398-403, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22306175

RESUMO

INTRODUCTION: The revascularisation of large (>3 mm) renal arteries emerging from the proximal sealing zone or off the aneurismal wall can be challenging during endovascular aortic aneurysm repair. In this article, we describe various endovascular techniques using custom-made endografts to treat these complex variant anatomies. CASES: Nine patients deemed unfit for open repair with unusual renal vascularisation associated with aortic aneurysms were treated by endovascular means. After three-dimensional (3D) reconstructions on a dedicated workstation, custom-made devices were designed and manufactured. The revascularisation of multiple renal arteries and aberrant origins of renal arteries, associated or not with pelvic kidney or horseshoe kidney, was managed using fenestrated and branched endografts. RESULTS: All target vessels were patent on computed tomography (CT) scan and contrast-enhanced ultrasound evaluation before discharge as well as on the 6-month follow-up. One patient presented a decrease of postoperative glomerular filtration rate over 30% but did not require dialysis. No sac enlargement was depicted, and no reintervention was performed during follow-up. Three type 2 endoleaks were diagnosed. CONCLUSION: Endovascular treatment with fenestrated and branched endografts should be considered in challenging renal artery anatomies in patients unfit for open repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Rim/irrigação sanguínea , Artéria Renal/anatomia & histologia , Idoso , Feminino , Humanos , Rim/anormalidades , Masculino , Pessoa de Meia-Idade
16.
Int J Parasitol ; 41(12): 1243-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21920366

RESUMO

Until recently, intensified efforts in China to suppress the transmission of Schistosoma japonicum relied principally on routine praziquantel treatment, extensive use of molluscicides and health education programs. These efforts, now supplemented by a broader range of control measures, have been quite successful in reducing the prevalence and intensity of human infection to very low levels. However, re-emergent transmission has occurred in formerly endemic areas of several provinces, signalling the need for more locally effective, integrated control strategies. We argue that these low but persistent levels of transmission also require important changes in both the tactics and strategy of disease surveillance to move forward towards elimination. Here we present recent data exemplifying the low transmission environment which suggests that we are reaching limits of detection of current diagnostic techniques used for human infection surveillance in these communities. However, both epidemiological data and theoretical results indicate that (i) transmission in the human population can persist at very low infection intensities even in the presence of routine control activities; (ii) the parasite can be reintroduced into parasite-free environments by very modest external inputs; and (iii) transmission at these low infection intensities exhibits very slow inter-year dynamics. These observations motivate the need for new, sensitive tools to identify low-level infections in mammalian or snail hosts, or the presence of S. japonicum in environmental media. Environmental monitoring offers an alternative, and perhaps more efficient, approach to large-scale surveillance of human infections in low transmission regions.


Assuntos
Parasitologia/métodos , Schistosoma japonicum/isolamento & purificação , Esquistossomose/diagnóstico , Esquistossomose/epidemiologia , Vigilância de Evento Sentinela , Animais , China/epidemiologia , Microbiologia Ambiental , Monitoramento Ambiental/métodos , Monitoramento Epidemiológico , Humanos , Esquistossomose/prevenção & controle , Esquistossomose/transmissão , Prevenção Secundária , Sensibilidade e Especificidade , Caramujos/parasitologia
17.
J Appl Microbiol ; 110(5): 1284-96, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21332895

RESUMO

AIMS: Bacterial communities in the apple phyllosphere were examined quantitatively and qualitatively by applying culture-dependent and culture-independent methods. METHODS AND RESULTS: Populations estimated by viewing cells stained with 4',6-diamidino-2-phenylindole generally were at least 100-1000 times greater than populations estimated by culturing on tryptic soy agar (TSA). Of the 44 operational taxonomic units (OTUs; cut-off threshold of 97%) detected in total, five bacterial orders containing 23 OTUs were identified by culturing on TSA, whereas nine orders containing 33 OTUs were identified by 16S rRNA gene cloning of DNA extracted from apple leaf surfaces. Twelve of the 44 OTUs were shared between cultured isolates and 16S rRNA gene clones and included the orders Burkholderiales, Pseudomonadales, Rhizobiales and Sphingomonadales. Three OTUs within the genus Sphingomonas accounted for 40% of isolates and 68% of clones. The Actinomycetales were found only among isolates, whereas the Bacteroidales, Enterobacteriales, Myxococales and Sphingobacteriales were represented in the 16S rRNA gene clone libraries but were absent among isolates. CONCLUSIONS: Culture-independent methods revealed greater numbers and greater richness of bacteria on apple leaves than found by culturing. SIGNIFICANCE AND IMPACT OF THE STUDY: This is the first study to directly compare culture-dependent and independent approaches for assessing bacterial communities in the phyllosphere. The biases introduced by different methods will have a significant impact on studies related to phyllosphere ecology, biological control of plant diseases, reservoirs of antibiotic resistance genes and food safety.


Assuntos
Bactérias/genética , Bactérias/isolamento & purificação , Malus/microbiologia , Folhas de Planta/microbiologia , Bactérias/classificação , Técnicas Bacteriológicas , Biodiversidade , Contagem de Colônia Microbiana , DNA Bacteriano/genética , Biblioteca Gênica , Filogenia , Doenças das Plantas/microbiologia , RNA Ribossômico 16S/genética
19.
Ann Trop Med Parasitol ; 99(1): 47-52, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15701255

RESUMO

A study of liver and colon cancers and their association with a previous diagnosis of schistosomiasis was performed in rural Sichuan, China. The data analysed came from 127 liver-cancer and 142 colon-cancer patients, each matched, by age, gender, hospital and township, with one or two controls. The cancer cases were identified from the hospital records of three Sichuan counties (all of which have some level of endemic schistosomiasis japonicum): Meishan (66 liver and 54 colon cases), Pujiang (16 liver and 22 colon cases) and Xichang (45 liver and 66 colon cases). Each control was selected using the hospital records for the same year the matched case of cancer was diagnosed, when the control had been found to have an illness other than cancer. Previous schistosomal infection was determined by examining the medical records at the county hospitals, searching the records at the local schistosomiasis-control stations or health-surveillance units, and, when no written record could be found, by interviews with the subjects or their relatives. Given the extremely strong association between hepatitis and liver cancer in China, only data from hepatitis-negative pairs were used in the analyses. Previous schistosomal infection was found to be significantly associated with both liver cancer (odds ratio = 3.7; 95% confidence interval = 1.0-13) and colon cancer (odds ratio = 3.3; 95% confidence interval = 1.8-6.1). The results indicate a fraction of disease attributable to schistosomiasis of 24% for colon cancer, and (among the hepatitis-negative population) one of 27% for liver cancer.


Assuntos
Neoplasias do Colo/epidemiologia , Neoplasias Hepáticas/epidemiologia , Esquistossomose Japônica/epidemiologia , Adulto , Idoso , Estudos de Casos e Controles , China/epidemiologia , Neoplasias do Colo/etiologia , Feminino , Hospitalização , Humanos , Neoplasias Hepáticas/etiologia , Masculino , Pessoa de Meia-Idade , Saúde da População Rural , Esquistossomose Japônica/complicações , Distribuição por Sexo
20.
Parasitology ; 125(Pt 3): 221-31, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12358419

RESUMO

During autumn 2000 an extensive cross-sectional survey of the prevalence of Schistosomiasis japonicum was conducted among about 4000 villagers within 20 villages in the Anning River Valley located in the southwestern Sichuan Province. Two procedures were used to assess infection status, the Kato-Katz thick smear procedure and a miracidia hatch test. Whereas the Kato-Katz procedure provides information on both prevalence and intensity, the hatch test provides only prevalence data, albeit on a much larger volume of stool. In addition, we performed Kato-Katz smears for 15 consecutive samples on a subset of 15 individuals. The proportion of both hatch-test and Kato-Katz positive individuals in the larger cross-sectional survey was 25%. The goal of the study was to estimate both the egg and worm distributions among risk groups using both the hatch and Kato-Katz tests from the cross-sectional data and the repeated Kato-Katz smears from the longitudinal data sets. As a prelude to parameter estimation, individuals were classified into risk groups by natural village and occupation; the proportion of Kato-Katz positive subjects among the risk groups varied from 10% to 60%. We used the statistical model of de Vlas et al. (1992) and Bayesian techniques to derive both estimates of and inference about the worm and egg distribution parameters. The parameter estimates imply (1) similar eggs per gram stool (e.p.g.) per worm pair compared with earlier estimates, (2) a range of worm burdens among the risk groups and (3) estimates of risk heterogeneity within groups is sensitive to prior information on the within-person variability in egg excretion.


Assuntos
Contagem de Ovos de Parasitas , Schistosoma japonicum/isolamento & purificação , Esquistossomose/epidemiologia , Esquistossomose/parasitologia , Fatores Etários , Animais , Teorema de Bayes , China/epidemiologia , Fezes/parasitologia , Feminino , Humanos , Masculino , Modelos Estatísticos , Prevalência , Fatores de Risco , Schistosoma japonicum/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...